anglicky - BD SENSORS
Transkript
anglicky - BD SENSORS
CS English EN WARNING! In order to avoid hazards to operators and damages to the device, the following instructions have to be performed by qualified technical personnel. Návod k montáži / Mounting instructions WARNING! Adhere to the safety and operating instructions stated in the operation manual. Effective regulations on occupational safety, accident prevention as well as national installation standards and approved engineering techniques must in addition be complied with. Tlakový spínač / Electronic Pressure Switch Mounting WARNING! Install the device only in depressurized and currentless state! WARNING! Use a suitable seal, corresponding to the medium and the pressure input. Pressure port G1/8" internal thread (DS 4) Pressure port M5x1 internal thread (DS 4) Limitation of liability DS 4, DS 6 If the instructions in the operating manual are not adhered to or if the device is inappropriately used, modified or damaged, liability is not assumed and warranty claims will be excluded. Intended use Ensure that the medium is compatible with the mediawetted parts and that the device is suitable for the application without restrictions. The technical data listed in the current data sheet is binding and must definitely be observed. approx. 3 Nm approx. 1 Nm Flange mounting (DS 4 with internal thread M5x1) El. connection M8x1 (4-pin) (DS 4) Product identification DS 4 DS 6 type designation ordering code nominal pressure range serial number www.bdsensors.com Fig. 1 manufacturing label DS 4 Centrála východní Evropa / Headquarters Ostern Europe BD SENSORS s.r.o. Hradišťská 817 CZ - 687 08 Buchlovice Česká republika / Czech Republic Tel.: +420 572 / 411 011 Fax: +420 572 / 411 497 Centrála západní Evropa / Headquarters Western Europe BD SENSORS GmbH BD-Sensors-Str. 1 D - 95199 Thierstein Německo / Germany Tel.: +49 (0) 92 35 / 98 11-0 Fax: +49 (0) 92 35 / 98 11-11 type designation ordering code serial number input - Install the device with 2 or 4 screws (M3) on the intended flange. When using low pressure ranges and usual conditions for the application are given, 2 screws will suffice. - Tighten the screws; the surfaces of pressure switch and counterpart must bear on each other. Pressure port according to DIN 3852 (DS 6) Rusko / Russia BD SENSORS RUS 39a, Varshavskoe shosse RU - Moscow 117105 Russland / Russia Tel.: +7 (0) 9 59 81 / 09 63 Fax: +7 (0) 9 57 95 / 07 21 Tento návod k montáži je výtah z podrobného návodu k obsluze. Ten si prosím stáhněte z našich internetových stránek, pokud nejste s výrobkem dobře seznámeni. supply pin configuration set point with setting Fig. 2 manufacturing label DS 6 Pin configuration approx. 5 Nm DS 4 Electrical connection Supply + Supply – Signal + (for analogue output) Contact 1 Contact 2 DS 6 Electrical connection These mounting instructions are an excerpt from the complete operating manual. It may be downloaded from our homepage, if you are not familiar with the device. www.bdsensors.cz www.bdsensors.com – Technické změny vyhrazeny – – Technical modifications reserved – El. connection M12x1 (5-pin) (DS 6) Supply + Supply – Contact 1 Contact 2 Shield M8x1 (4-pin) 1/bn (brown) 3/bu (blue) 2/wh (white) 4/bk (black) 2/wh (white) M12x1 (5-pin) 1 3 4 5 plug housing Wiring diagrams with analogue output (only DS 4) without analogue output supply + supply + VS VS supply – U signal + supply – RL U contact contact 1 RL RL contact 2 For the electrical connection a shielded and twisted multicore cable is recommended. MA_DS4-DS6_C-E_12.02.2015
Podobné dokumenty
anglicky - BD SENSORS
For more information, please read the detailed operating manual!
DMD 331:
G 1/2" acc. to EN 837
English CS EN Návod k montáži / Mounting
BD SENSORS China Co, Ltd.
6th Floor, Building B, No. 8
Lane 658 Jinzhong Rd.
200335 Shanghai, CN
China
Tel.: +86 (0) 21-51600 190
Fax: +86 (0) 21-33600 610