Čeština - Loxone
Transkript
• Low Profile for Building Automation • 5V to 24V Outputs • Wide Range AC Input • -25°C to +71°C Operation • Convection Cooled • UL1310 Class 2 • Class II Double Insulation Key Market Segments & Applications Building Services Automation: DSP Series Alarms and Security, Access and Fire Safety Systems, Lighting and Environment Control Systems. 7.5W to 100W Low Profile Din Rail Mount Power Supplies DSP Features and Benefits Features Benefits • Low 56mm Profile • Wide Range AC • Convection cooled • Fits into wall mounted cabinets • Global use with no input selector switches • No system fan required Specifications MODEL ITEMS AC Input Voltage range Input Frequency DC Input Voltage range Inrush Current (115 / 230VAC) Power Factor Output Voltage Accuracy Line Regulation Load Regulation Ripple and Noise (20MHz BW) Overcurrent Protection (Typ) Overvoltage Protection Hold Up Time (115VAC input) LED Indicators Operating Temperature Temperature Coefficient Storage Temperature Operating Humidity Cooling Withstand Voltage Isolation Resistance Vibration (Operating) Shock (Operating) Safety Agency Approvals Immunity Conducted & Radiated EMI Weight (Typ) Size (WxHxD) Case material Warranty DSP10 VAC Hz VDC A % % % mV V ms %/°C Ω g mm yrs DSP30 DSP60 DSP100 90 - 264VAC, Class II double insulated (No ground connection required) 47 - 63Hz 120 - 370VDC 15 / 30A 25 / 50A 30 / 60A 30 / 60A Meets EN61000-3-2, EN61000-3-3 ±1% of Nominal 1% 1% 50mV(1) 110 - 160%, fold forward under short circuit (DSP100-24/C2 102-108%) 120 - 145% See Model Selector Green LED = On, Red LED = DC Output Low -25 to +71°C (Derate linearly 2.5%/°C from 55 to 71°C) ±0.02%/°C -25°C to +85°C 20 - 95% RH (non condensing) Convection Input to Output 3kVAC for 1 min. >100MΩ at 25°C & 70%RH, Input to Ground 500VDC IEC60068-2-6 (Mounting by rail: Random wave, 100-500Hz, 2G, ea. along X, Y, Z axes 10min/cycle, 60 min) IEC60068-2-27 (Half sine wave, 4G, 22ms, 3 axes, 6 faces, 3 times for each face) UL1310 Class 2(2), UL508 Listed, UL60950-1, EN60950-1, CE EN61000-4-2, -3, -4, -5, -6, -8 & -11 EN55022 class B EN55022 class A 60 200 250 320 18 x 91 x 55.6 53 x 91x 55.6 71 x 91 x 55.6 90 x 91 x 56.8 Plastic 2 Note 1: For DSP100-24/C2 Ripple & Noise measured with Vin 115- 230 Vac Note 2: Excludes Models: DSP60-5, DSP60-12, DSP100-12, DSP100-15, DSP100-24 DSP Series 1 Model Selector Model Voltage (V) Voltage Adjust (V) Current (A) Power (W) Efficiency (Typ %) DSP10-5 5 None 1.5 7.5 74 10 DSP30-5 5 5 - 5.5 3.0 15.0 74 25 DSP60-5 5 5 - 5.5 7.0 35.0 80 16 DSP10-12 12 None 0.83 10.0 78 10 DSP30-12 12 12 - 14 2.1 25.2 82 25 DSP60-12 12 12 - 14 4.5 54.0 84 16 DSP100-12 12 12 - 14 6.0 72.0 82 16 DSP10-15 15 None 0.67 10.1 78 60 DSP30-15 15 13.5 - 16.5 2.0 30.0 83 25 DSP60-15 15 13.5 - 16.5 4.0 60.0 85 12 DSP100-15 15 13.5 - 16.5 5.0 75.0 85 16 DSP10-24 24 None 0.42 10.1 80 60 DSP30-24 24 24 - 28 1.3 31.2 83 25 DSP60-24 24 24 - 28 2.5 60.0 86 12 DSP100-24/C2 24 20 -24.2 3.8 91.2 89 10 DSP100-24 24 24 - 28 4.2 100.8 85 10 Outline Drawing DSP10 Series mm [inch] 18.00 14.20 9.75 43.1 L N 91.00 3 4 DSP Series 55.6 49.00 32.10 91.00 1 2 2 HoldUp Time 115VAC in (ms) Outline Drawing DSP30 Series mm [inch] 14.20 53.00 1 9.75 43.1 L N 5 6 55.6 49.00 32.10 91.00 4 91.00 Outline Drawing DSP60 Series mm [inch] 14.20 71.00 1 9.75 43.1 4 DC LO 55.6 49.00 32.10 91.00 DC ON 91.00 5 6 Outline Drawing DSP100 Series mm [inch] 14.20 89.9 43.1 4 32.10 49.00 56.8 91.00 1 9.75 91.00 5 6 DSP Series 3 TDK-LAMBDA EMEA www.emea-tdk-lambda.com TDK-Lambda France SAS TDK-Lambda UK Ltd. ZAC des Delaches BP 1077-Gometz-le-Chatel 91940 Les Ulis France Tel: +33 1 60 12 71 65 Fax: +33 1 60 12 71 66 [email protected] www.fr.tdk-lambda.com Kingsley Avenue Ilfracombe Devon EX34 8ES United Kingdom Tel: +44 (0) 12 71 85 66 66 Fax: +44 (0) 12 71 86 48 94 [email protected] www.uk.tdk-lambda.com Italy Sales Office Nemic Lambda Ltd. Via dei Lavoratori 128/130 20092 Cinisello Balsamo (MI) Italy Tel: +39 02 61 29 38 63 Fax: +39 02 61 29 09 00 [email protected] www.it.tdk-lambda.com Kibbutz Givat Hashlosha 48800 Israel Tel: +9 723 902 4333 Fax: +9 723 902 4777 [email protected] www.nemic.co.il TDK-Lambda Germany GmbH Karl-Bold-Strasse 40 77855 Achern Germany Tel: +49 7841 666 0 Fax: +49 7841 5000 [email protected] www.de.tdk-lambda.com Russia Technical Support: St Petersburg Tel: +7 (812) 6580463 Sales: Moscow Tel: +7 (499) 7557732 [email protected] www.tdk-lambda.ru Austria Sales Office Aredstrasse 22 2544 Leobersdorf Austria Tel: +43 2256 655 84 Fax: +43 2256 645 12 [email protected] www.de.tdk-lambda.com LOCAL DISTRIBUTION DSP Jan11 v5 4 DSP Series
Podobné dokumenty
Official Electronic - Elektronické součástky, konektory, LED, ventilátory
Cold start 40A/115VAC
Verze pro tisk - Plzeňské městské dopravní podniky as
32S 52S
22MS 32S 52S
23S 38S 53S
23S 38S 53S
23S 38S 53S
23S 38S 53S
23S 38S 53S
23S 38S 53S
23S 38S 53S
23S 38S 53S
23S 38S 53S
23S 38S 53S
23S 38S 53S
23S 38S 53S
24S 39S 57S
38S 58S
38S 58S
47S
HQD Digitální elektrochemie
Heslem chráněné programy a nastavení
➔ Náhodné změny nastavení jsou vyloučeny, výborná provozní
spolehlivost
JetNet 3705f / 3705f-w
AC/DC Power Adapter 48VDC/1.6A (option)
One DC jack for AC/DC power adapter
Reverse Polarity Protection: Present
Power Consumption: 6.5Watts without PD loading
70Watts with PD full loading
elektronická trafa myrra řady 47000
S jedním stabilizovaným výstupním napětím (v rozsahu 3.3 až 24VDC) – zapojení vývodů viz obr. 2
S jedním nestabilizovaným výstupním napětím (v rozsahu 9 až 24VDC) – zapojení vývodů viz obr. 2
Se dv...
CENÍK - TRON
Pozn.: LED pásky CREE II. generace jsou určeny pro aplikace s požadovanou vysokou svítivostí a dlouhodobou životností a koeficientem barevného podání Ra>80.
Jsou v nich použity nové LED CREE řady X...
listopad - Farnost Jirkov
Existuje po smrti ještě jiná forma života? (Podle BTM)
Jsme schopni dobrat se k nějaké pravdě? To jsou otázky, nad kterými je dobré se vážně zamýšlet. Ano, pro mnoho lidí není snadné se vyrovnat s...