multiset vrf, dc inverter r410a
Transkript
multiset vrf, dc inverter r410a
Air Conditioners 2006 improve your life improve your life Argoclima S.p.A is an essential component of AER.FI. Group that, in only one decade has become one of the most important European structures for the production and the commercialization of air-conditioners for the residential and commercial markets. Both the structures, productive and commercial, are placed in Italy, in Gallarate, around 40 km from Milano and can be easily reached by the Milano-Laghi A8 highway and by train. Argoclima owns ARGO brand, with which promotes and trades in Italy a wide range of air conditioning, heating and air treatment products, granting high quality levels and service, with its around 500 certified Technical Assistant Centers and a spare parts centralized management on all the European territory. Argoclima has been able to value ARGO brand and its history of success born at the end of 1920, transforming itself and dynamically managing the fast speed changing of the life and working environments and styles. Today ARGO is a technological and reliable brand, but also a young, dynamic and friendly brand. "Improve your life" is ARGO pay-off: our desire is to improve the quality of life by w w w. a r g o c l i m a . c o m improving the comfort of people using our products. improve your life INDEX R410A SECTION XFETTO - AIR CONDITIONER / WATER RADIATOR pag 6-10 PORTABLE pag 12-20 SPLIT ON/OFF pag 22-45 SPLIT DC INVERTER pag 47-50 MULTISPLIT DC INVERTER pag 52-56 PACKAGE / MULTIPACKAGE DC INVERTER pag 58-73 MULTISET V.R.F. DC INVERTER pag 75-109 HEAT RECOVERY UNITS pag 111-112 OPERATING LIMITS pag 113 PORTABLE pag 115-119 SPLIT/MULTISPLIT ON/OFF pag 121-133 PACKAGE/MULTIPACKAGE pag 135-144 MULTISET V.R.F. pag 146-161 Rules for the application of the energy label pag 162 w w w. a r g o c l i m a . c o m R407C SECTION AIR CONDITIONER/WATER RADIATOR R410A w w w. a r g o c l i m a . c o m improve your life XFETTO - R410A improve your life XFETTO 245C Technical data PRODUCT NAME Features Cooling capacity (Air-Conditioner mode) Heating capacity (Water Radiator mode) Energy label class E.E.R. / C.O.P. Air flowrate (h.m.l.) Dehumidification Fan speeds Sound pressure in Air-Conditioner mode (h.m.l.) Sound pressure in Water radiator mode (h.m.l.) Power supply Running consumption in Air-Conditioner mode Annual energy cons.- A-C mode (500h) - Directive 2002/31/CE Running consumption in Water radiator mode Refrigerant type Ducts diameter Hydraulic connection diameter on the heating plant (W.R.mode) Condensate discharge Net weight Net dimensions (H./W./D.) Units kW BTU/h kcal/h kW ABCDEFG (kW/kW) m³/h l/h n° dB(A) dB(A) V/Ph/Hz kW kWh kW mm inch Kg mm XFETTO 245C Cooling Heating 2,45 8.360 2.110 2,10 A 2,62 330-300-280 1,2 3 + Auto 45-43-41 42-39-32 230/1/50 0,935 468 0,027 R410A 162 1/2" not requested 50 735x839x260-280 WITHOUT OUTDOOR UNIT DUCTS AND GRILLS INCLUDED The technical data here indicated are in compliance with the European standard EN14511 - Directive 2002/31/EC Features Packaged double-duct straight cooling air conditioner without outdoor unit Water radiator Air condensation by means of two ducts connected outside To be installed on a perimetral wall Infrared remote control with 4 digital timers to be set on the 24h and week-end w w w. a r g o c l i m a . c o m Double temperature sensor (on the unit and inside the remote control); double temperature indication (set and room) "I Feel" feature Dry only feature Ventilation only feature "Sleep" function with night set-back capability Horizontal flap swinging or to be set to a fixed position by remote control Vertical flap by manual control Anti-mould and anti-bacteria washable filters Variable speed of the condensing fan to reduce at minimum the external noise Three-speed tangential fan with auto or speed manual selection "Cold Draft Prevention" device with water temperature less than 40°C in water radiator mode High precision thermostat with adjustment from 6°C to 40°C in water radiator mode Auto restart after a black out, saving all feature parameters set before the power failure Electronic protection against over-pressures HFC refrigerant R410A High efficiency rotary compressor Optional joint kit for hydraulic connection to the heating plant (necessary only in water radiator mode) Three-way bypass valve included in the water conncetion module Special optional support kit of two small feet for floor installations (glass walls, etc.) 6 XFETTO - R410A improve your life XFETTO 235H Technical data PRODUCT NAME Features Cooling/Heating capacity (Air-Conditioner mode) Heating capacity (Water Radiator mode) Energy label class E.E.R. / C.O.P. Air flowrate (h.m.l.) Dehumidification Fan speeds Sound pressure in Air-Conditioner mode (h.m.l.) Sound pressure in Water radiator mode (h.m.l.) Power supply Running consumption in Air-Conditioner mode Annual energy cons.- A-C mode (500h) - Directive 2002/31/CE Running consumption in Water radiator mode Refrigerant type Ducts diameter Hydraulic connection diameter on the heating plant (W.R.mode) Condensate discharge Net weight Net dimensions (H./W./D.) Units kW BTU/h kcal/h kW ABCDEFG (kW/kW) m³/h l/h n° dB(A) dB(A) V/Ph/Hz kW kWh kW mm inch Kg mm XFETTO 235H Cooling Heating 2,35 2,25 8.020 7.700 2.020 1.935 2,10 A C 2,61 2,64 330-300-280 1,0 3 + Auto 45-43-41 42-39-32 230/1/50 0,900 450 0,027 R410A 162 1/2" by duct, outside or inside the room 52 735x839x260-280 WITHOUT OUTDOOR UNIT DUCTS AND GRILLS INCLUDED The technical data here indicated are in compliance with the European standard EN14511 - Directive 2002/31/EC Features Packaged double-duct straight cooling and heat pump air conditioner without outdoor unit Water radiator Air condensation by means of two ducts connected outside To be installed on a perimetral wall Automatic change-over between cooling and heating modes Infrared remote control with 4 digital timers to be set on the 24h and week-end "I Feel" feature Dry only feature Ventilation only feature "Sleep" function with night set-back capability Horizontal flap swinging or to be set to a fixed position by remote control Vertical flap by manual control Anti-mould and anti-bacteria washable filters Variable speed of the condensing fan to reduce at minimum the external noise Three-speed tangential fan with auto or speed manual selection "Cold Draft Prevention" device with water temperature < 40°C in water radiator mode and with evaporator temperature < 40°C in heat pump mode High precision thermostat with adjustment from 6°C to 40°C in water radiator mode Heating function disabled during defrosting cycle Auto restart after a black out, saving all feature parameters set before the power failure Electronic protection against over-pressures HFC refrigerant R410A High efficiency rotary compressor Optional joint kit for hydraulic connection to the heating plant (necessary only in water radiator mode) w w w. a r g o c l i m a . c o m Double temperature sensor (on the unit and inside the remote control); double temperature indication (set and room) Three-way bypass valve included in the water conncetion module Special optional support kit of two small feet for floor installations (glass walls, etc.) 7 X F E T T O H 2O - R 4 1 0 A improve your life XFETTO 245SC H 2 O - 235HP H 2 O Features Packaged double-duct straight cooling (Xfetto 245scH2O) and heat pump (Xfetto 235hpH2O) air conditioner without outdoor unit Water radiator Water-cooled air-conditioner (Xfetto 245scH2O); Water/air heat pump (Xfetto 235hpH2O) (according to standard EN14511) Water condensation with a water avarage consumption of about 1 cubic meter for a 8 hour operation To be freely installed, not necessarily on a perimetral wall, because no holes in the wall are requested Designed to operate with both town water and wellwater or groundwater; it can be used also as terminal unit of a closed circuit system (water loop) with water at 30°C, according to EN14511 standard specifications High efficiency spiral heat exchanger Solenoid valve to stop the town water flowrate when the compressor is off Anti-freeze protection on the condensation water circuit It's suggested the installation of a filter to be inspected on the entry of the town water (by the installer) Automatic change-over between cooling and heating modes (Xfetto 235hpH2O) Infrared remote control with 4 digital timers to be set on the 24h and week-end Double temperature sensor (on the unit and inside the remote control) Double temperature indication (set and room) "I Feel" feature Dry only feature Ventilation only feature w w w. a r g o c l i m a . c o m "Sleep" function with night set-back capability Horizontal flap swinging or to be set to a fixed position by remote control Vertical flap by manual control Anti-mould and anti-bacteria washable filters Three-speed tangential fan with auto or speed manual selection Cold Draft Prevention" device with water temperature< 40°C in water radiator mode and with evaporator temperature< 40°C in heat pump mode (Xfetto 235hpH 2 O) High precision thermostat with adjustment from 6°C to 40°C in water radiator mode Heating function disabled during defrosting cycle (Xfetto 235hpH2O) Auto restart after a black out, saving all feature parameters set before the power failure Electronic protection against over-pressures HFC refrigerant R410A High efficiency rotary compressor Optional joint kit for hydraulic connection to the heating plant (necessary only in water radiator mode) Three-way bypass valve included in the water conncetion module Special optional support kit of two small feet for floor installations (glass walls, etc.) 8 X F E T T O H 2O - R 4 1 0 A WITHOUT OUTDOOR UNIT WITHOUT HOLES IN THE WALL improve your life PRODUCT NAME Operation Features Cooling capacity (Air-Conditioner mode) Energy label class E.E.R. / C.O.P. Air flowrate (h.m.l.) Dehumidification Fan speeds Sound pressure in Air-Conditioner mode (h.m.l.) Power supply Running consumption in Air-Conditioner mode Annual energy cons.- A-C mode (500h) - Directive 2002/31/EC Water flowrate for the heat exchanger Pressure drops Refrigerant type Water connection diameter (in/out) Condensate drain connection diameter (inside or outside) Heat transferred to water Heat moved from water Heating capacity in Water Radiator mode Running consumption in Water radiator mode Water flowrate in Water Radiator mode Pressure drops in Water Radiator mode Hydraulic connection diameter to the heating plant (W.R.mode) Sound pressure in Water radiator mode (h.m.l.) Net weight Net dimensions (H./W./D.) Units kW BTU/h kcal/h ABCDEFG (kW/kW) m³/h litri/h n° dB(A) V/Ph/Hz kW kWh m³/h KPa inch mm kW kW kW kW m³/h kPa inch dB(A) Kg mm XFETTO 245SCH2O Town water Water loop (*) Cooling Cooling 2,83 2,7 9.650 9.200 2.430 2.320 B 4,42 4,15 330-300-280 1,2 1,2 3 + Auto 3 + Auto 44-42-41 44-42-41 230/1/50 0,640 0,650 325 0,150 0,525 2,9 38,0 R410A R410A 1/2" (gas) 3/4" (gas) 18 18 3,47 3,35 2,1 0,027 0,19 2,9 1/2" 42-40-38 46 735x839x260-280 water loop: standard conditions EN14511 Technical data Town water - Cooling - Room Temp. 27°C d.b./ 19°C w.b. - Water Temp.: inlet 18°C - outlet 36°C / Water radiator - Room Temp. 20°C - Water Temp.: inlet 70°C - outlet 60° Cooling - Room Temp. 27°C d.b. / 19°C w.b. - Water Temp.: inlet 30°C - outlet 35°C / Water radiator - Room Temp. 20°C - Water Temp.: inlet 70°C - outlet 60°C PRODUCT NAME Operation Features Cooling/Heating capacity (Air-Conditioner mode) Energy label class E.E.R. / C.O.P. Air flowrate (h.m.l.) Dehumidification Fan speeds Sound pressure in Air-Conditioner mode (h.m.l.) Power supply Running consumption in Air-Conditioner mode Annual energy cons.- A-C mode (500h) - Directive 2002/31/EC Water flowrate for the heat exchanger Pressure drops Refrigerant type Water connection diameter (in/out) Condensate drain connection diameter (inside or outside) Heat transferred to water Heat moved from water Heating capacity in Water Radiator mode Running consumption in Water radiator mode Water flowrate in Water Radiator mode Pressure drops in Water Radiator mode Hydraulic connection diameter to the heating plant (W.R.mode) Sound pressure in Water radiator mode (h.m.l.) Net weight Net dimensions (H./W./D.) Units kW BTU/h kcal/h ABCDEFG (kW/kW) m³/h litri/h n° dB(A) V/Ph/Hz kW kWh m³/h KPa inch mm kW kW kW kW m³/h kPa inch dB(A) Kg mm XFETTO 235HPH2O Town water Water loop (*) Cooling Heating Cooling Heating 2,95 3,15 3,00 3,56 10.060 10.740 10.230 12.140 2.540 2.710 2.580 3.060 A C 4,68 3,80 4,41 4,14 330-300-280 330-300-280 1,3 1,3 3 + Auto 3 + Auto 44-42-41 44-42-41 230/1/50 0,630 0,830 0,680 0,860 340 0,150 0,525 2,9 40,3 R410A R410A 1/2" (gas) 3/4" (gas) 18 18 3,58 3,68 2,04 2,7 2,1 0,027 0,19 2,9 1/2" 42-40-38 48 735x839x260-280 Town water - Cooling: Room Temp. 27°C d.b. / 19°C w.b. - Water Temp. : inlet 18°C - outlet 36°C / Heat Pump : Room Temp. 20°C d.b. - Water Temp.: inlet 18°C - outlet 6°C Water loop - Cooling: Room Temp . 27°C d.b. / 19°C w.b. - Water Temp.: inlet 30°C - outlet 35°C / Heat Pump : Room Temp. 20°C d.b. - Water Temp. 15°C w w w. a r g o c l i m a . c o m Water loop - Water radiator - Room Temp. 20°C - Water Temp.: inlet 70°C - outlet 60°C (*) Water loop (EN14511 Definition) Closed circuit of water maintained within a temperature range on which the units in cooling mode reject heat and the units in heating mode take heat 9 XFETTO R410A - ACCESSORIES improve your life ACCESSORIES cm 16 The optional joint kit for hydraulic connection to the heating plant is necessary only to use Xfetto in water radiator mode. It'symmetric and can be installed on the right side as well as on the left side of the unit, without any change; it is composed of a plastic cover and of all the components (electronic and hydraulic) necessary to make the unit working as radiator (control panel with requested electrical wirings, three-way bypass valve). We suggest to make the necessary checks on the heating plant before installing the hydraulic connection. cm 62,9 w w w. a r g o c l i m a . c o m cm 13 10 Optional support kit (two small feet) for floor installations (glass walls,etc.) cm 11,9 cm 22,9 cm 11,7 w w w. a r g o c l i m a . c o m P O R TA B L E R 4 1 0 A improve your life S I N G L E - D U C T P O R TA B L E R 4 1 0 A improve your life Magico 9.2 Air conditioner or dehumidifier only, it is useful in all year seasons Infrared remote control with 4 digital timers to be set on the 24h and week-end, night set back, startup of air-conditioning or dehumidifying or three-speed ventilation only modes, temperature digital adjusment and room temperature control by a special sensor inside the remote control Automatic condensate vaporization through the pipe for the elimination of the hot air; this function, operating at medium and maximum fan speeds, avoids stops due to tank filling, particularly annoying during the night Adjustable air louver, granting the best fresh air diffusion Anti-mould and anti-bacteria washable filters Auto restart after a power supply black out Electronic protection against over-pressures REMOTE CONTROL High efficiency rotary compressor Easy to move thanks to its comfortable handles and special multidirectional wheels Useful cable winding space on the rear Infrared remote control with w w w. a r g o c l i m a . c o m temperature sensor inside 12 Technical data PRODUCT NAME Features Cooling capacity (35°C d.b.; 24°C w.b.) / (27°C d.b.; 19°C w.b.) Energy label class E.E.R. (35°C d.b.; 24°C w.b.) / (27°C d.b.; 19°C w.b.) Air flowrate (h.m.l.) Dehumidification in Cooling (C) mode Dehumidification in Dry (D) mode (30°C - 80% r.h.) Fan speeds (C) / (D) Sound pressure (h.l.) Power supply Running consumption (C) (35°C d.b.; 24°C w.b.) / (27°C d.b.; 19°C w.b.) Annual energy consumption (C) (500h)-Dir. 2002/31/CE Refrigerant type Hole in the window (diameter) Flexible exhaust tube (diameter) Flexible exhaust tube (extended lenght) Net weight Net dimension (H./W./D.) Units kW BTU/h kcal/h ABCDEFG (kW/kW) m³/h l/h l/24h n° dB(A) V/F/Hz kW kWh mm mm m Kg mm MAGIC0 9.2 Cooling 2,73 / 2,57 9.300 / 8.800 2.350 / 2.210 A/A 2,62 / 2,78 310-280-260 1,25 51 3 + Auto / 1 44-41 230/1/50 1,040 / 0,925 520 / 462 R410A 138 115 1 34 965x530x410 The technical data here indicated are in compliance with the European standard EN14511 - Directive 2002/31/EC S I N G L E - D U C T P O R TA B L E R 4 1 0 A improve your life Mythiko Air conditioner or dehumidifier only, it is useful in all year seasons Weekly programmable digital timer and electronic thermostat Two-speed fan Frontal air-intake, making possible its placement even between two walls Automatic condensate vaporization through the pipe for the elimination of the hot air; this function, operating at maximum fan speed, avoids stops due to tank filling, particularly annoying during the night Adjustable air louver, granting the best fresh air diffusion Anti-mould and anti-bacteria washable filters Auto restart after a power supply black out DIGITAL TIMER Electronic protection against over-pressures High efficiency rotary compressor Easy to move thanks to its comfortable handles and special multidirectional wheels Useful cable winding space on the rear Weekly programmable digital timer Technical data MODELLO Features Cooling capacity (35°C d.b.; 24°C w.b.) / (27°C d.b.; 19°C w.b.) Energy label class E.E.R. (35°C d.b.; 24°C w.b.) / (27°C d.b.; 19°C w.b.) Air flowrate (h.l.) Dehumidification in Cooling (C) mode Dehumidification in Dry (D) mode (30°C - 80% r.h.) Fan speeds (C) / (D) Sound pressure (h.l.) Power supply Running consumption (C) (35°C d.b.; 24°C w.b.) / (27°C d.b.; 19°C w.b.) Annual energy consumption (C) (500h)-Dir. 2002/31/CE Refrigerant type Hole in the window (diameter) Flexible exhaust tube (diameter) Flexible exhaust tube (extended lenght) Net weight Net dimension (H./W./D.) Units kW BTU/h kcal/h ABCDEFG (kW/kW) m³/h l/h l/24h n° dB(A) V/F/Hz kW kWh mm mm m Kg mm MYTHIKO Cooling 2,25 / 2,06 7.680/ 7.030 1.935 / 1.770 A/A 2,81/ 2,94 310-260 1,0 42 2/1 44-41 230/1/50 0,800 / 0,700 400 / 350 R410A 138 115 1 30 860x482x376 The technical data here indicated are in compliance with the European standard EN14511 - Directive 2002/31/EC w w w. a r g o c l i m a . c o m Optional porthole kit for windows 13 S I N G L E - D U C T P O R TA B L E R 4 1 0 A improve your life Oscar Chrome A Air conditioner or dehumidifier only, it is useful in all year seasons Weekly programmable digital timer and electronic thermostat Two-speed fan Frontal air-intake, making possible its placement even between two walls Automatic condensate vaporization through the pipe for the elimination of the hot air; this function, operating at maximum fan speed, avoids stops due to tank filling, particularly annoying during the night Adjustable air louver, granting the best fresh air diffusion Anti-mould and anti-bacteria washable filters Auto restart after a power supply black out Electronic protection against over-pressures DIGITAL TIMER High efficiency rotary compressor Easy to move thanks to its comfortable handles and special multidirectional wheels Useful cable winding space on the rear w w w. a r g o c l i m a . c o m Weekly programmable digital timer 14 Technical data PRODUCT NAME Features Cooling capacity (35°C d.b.; 24°C w.b.) / (27°C d.b.; 19°C w.b.) Energy label class E.E.R. (35°C d.b.; 24°C w.b.) / (27°C d.b.; 19°C w.b.) Air flowrate (h.l.) Dehumidification in Cooling (C) mode Dehumidification in Dry (D) mode (30°C - 80% r.h.) Fan speeds (C) / (D) Sound pressure (h.l.) Power supply Running consumption (C) (35°C d.b.; 24°C w.b.) / (27°C d.b.; 19°C w.b.) Annual energy consumption (C) (500h)-Dir. 2002/31/CE Refrigerant type Hole in the window (diameter) Flexible exhaust tube (diameter) Flexible exhaust tube (extended lenght) Net weight Net dimension (H./W./D.) Units kW BTU/h kcal/h ABCDEFG (kW/kW) m³/h l/h l/24h n° dB(A) V/F/Hz kW kWh mm mm m Kg mm OSCAR CHROME A plus Cooling 2,20 / 2,10 7.500 / 7.200 1.890 / 1.810 A/A 2,75 / 3,00 310-260 1,0 42 2/1 44-41 230/1/50 0,800 / 0,700 400 / 350 R410A 138 115 1 30 870x450x363 The technical data here indicated are in compliance with the European standard EN14511 - Directive 2002/31/EC S I N G L E - D U C T P O R TA B L E R 4 1 0 A improve your life Oscar Super A Air conditioner or dehumidifier only, it is useful in all year seasons Weekly programmable digital timer and electronic thermostat Two-speed fan Frontal air-intake, making possible its placement even between two walls Automatic condensate vaporization through the pipe for the elimination of the hot air; this function, operating at maximum fan speed, avoids stops due to tank filling, particularly annoying during the night Adjustable air louver, granting the best fresh air diffusion Anti-mould and anti-bacteria washable filters Auto restart after a power supply black out Electronic protection against over-pressures DIGITAL TIMER High efficiency rotary compressor Easy to move thanks to its comfortable handles and special multidirectional wheels Useful cable winding space on the rear Technical data PRODUCT NAME Features Cooling capacity (35°C d.b.; 24°C w.b.) / (27°C d.b.; 19°C w.b.) Energy label class E.E.R. (35°C d.b.; 24°C w.b.) / (27°C d.b.; 19°C w.b.) Air flowrate (h.l.) Dehumidification in Cooling (C) mode Dehumidification in Dry (D) mode (30°C - 80% r.h.) Fan speeds (C) / (D) Sound pressure (h.l.) Power supply Running consumption (C) (35°C d.b.; 24°C w.b.) / (27°C d.b.; 19°C w.b.) Annual energy consumption (C) (500h)-Dir. 2002/31/CE Refrigerant type Hole in the window (diameter) Flexible exhaust tube (diameter) Flexible exhaust tube (extended lenght) Net weight Net dimension (H./W./D.) Units kW BTU/h kcal/h ABCDEFG (kW/kW) m³/h l/h l/24h n° dB(A) V/F/Hz kW kWh mm mm m Kg mm OSCAR SUPER A plus Cooling 2,20 / 2,10 7.500 / 7.200 1.890 / 1.810 A/A 2,75 / 3,00 310-260 1,0 42 2/1 44-41 230/1/50 0,800 / 0,700 400 / 350 R410A 138 115 1 30 870x450x363 The technical data here indicated are in compliance with the European standard EN14511 - Directive 2002/31/EC w w w. a r g o c l i m a . c o m Weekly programmable digital timer 15 S I N G L E - D U C T P O R TA B L E R 4 1 0 A improve your life Oscar Junior Portable air conditioner with frontal air-intake, making possible its placement even between two walls Two-speed fan High-capacity tank for condensate, easy to extract Adjustable air louver, granting the best fresh air diffusion Anti-mould and anti-bacteria washable filters Auto restart after a power supply black out Electronic protection against over-pressures High efficiency rotary compressor Easy to move thanks to its comfortable handles and special multidirectional wheels w w w. a r g o c l i m a . c o m Useful cable winding space on the rear 16 Technical data PRODUCT NAME Features Cooling capacity (35°C d.b.; 24°C w.b.) / (27°C d.b.; 19°C w.b.) Energy label class E.E.R. (35°C d.b.; 24°C w.b.) / (27°C d.b.; 19°C w.b.) Air flowrate (h.l.) Dehumidification Fan speeds Sound pressure (h.l.) Power supply Running consumption (35°C d.b.; 24°C w.b.) / (27°C d.b.; 19°C w.b.) Annual energy consumption (500h)-Dir. 2002/31/CE Refrigerant type Hole in the window (diameter) Flexible exhaust tube (diameter) Flexible exhaust tube (extended lenght) Net weight Net dimension (H./W./D.) Units kW BTU/h kcal/h ABCDEFG (kW/kW) m³/h l/h n° dB(A) V/F/Hz kW kWh mm mm m Kg mm OSCAR JUNIOR Cooling 1,88 / 1,80 6.400 / 6.200 1.620 / 1.550 C/B 2,22 / 2,50 290-220 0,45 2 43-40 230/1/50 0,845 / 0,720 422 / 360 R410A 138 115 1 30 961x455x356 The technical data here indicated are in compliance with the European standard EN14511 - Directive 2002/31/EC S P L I T P O R TA B L E R 4 1 0 A improve your life Oscar Twin 9 A / 11 A / 14 A Split portable air conditioner, with a small condensing case, specifically projected to be placed on balcony or window Weekly programmable digital timer and electronic thermostat (Oscar Twin 9A) Infrared remote control with 4 digital timers to be set on the 24h and week-end, night set back, start-up of air-conditioning or dehumidifying or ventilation only modes, temperature digital adjustment and room temperature control by a special sensor inside the remote control. Double temperature sensor (on remote control / on indoor unit) (Oscar Twin 11A/14A) Two-speed fan (Oscar Twin 9A), three-speed fan (Oscar Twin 11A/14A) TIMER DIGITALE Frontal air-intake, making possible its placement even between two walls Automatic condensate vaporization through the case AeroQuip quick connectors to easily disconnect and re-connect the outdoor unit for a fixed installation Adjustable air louver, granting the best fresh air diffusion Weekly programmable digital timer (Oscar Twin 9A) Anti-mould and anti-bacteria washable filters AEROQUIP Auto restart after a power supply black out TELECOMANDO Electronic protection against over-pressures High efficiency rotary compressor Easy to move thanks to its comfortable handles and special multidirectional wheels “Aeroquip” quick connectors Optional pipe-extension kits connecting Indoor and Outdoor units (2 and 4m) Infrared remote control with temperature sensor (Oscar Twin11A/14A) Technical data PRODUCT NAME Features Cooling capacity Energy label class E.E.R. Air flowrate (h.l.) Dehumidification Fan speeds (Indoor / Outdoor) Sound pressure Indoor (h.l.) Sound pressure Outdoor (h.) Power supply Running consumption Annual energy consumption-cooling mode(500h)-Dir. 2002/31/CE Refrigerant type Standard pipe lenght Additional pipe lenght Max. height between units (Outdoor on the top) Max. height between units (Indoor on the top) Net weight Indoor / Outdoor Net dimension Indoor (H./W./D.) Net dimension Outdoor (H./W./D.) Units kW BTU/h kcal/h ABCDEFG (kW/kW) m3/h l/h n° dB(A) dB(A) V/Ph/Hz kW OSCAR TWIN 9A Cooling 2,65 9.040 2.280 A 3,23 420-300 0,8 2/1 38-31 47 230/1/50 0,820 OSCAR TWIN 11A Cooling 2,91 9.920 2.500 A 3,26 420-300 1,0 3 + Auto / 1 39-32 47 230/1/50 0,890 OSCAR TWIN 14A Cooling 4,01 13.670 3.450 A 3,21 460-350 1,6 3 + Auto / 1 40-33 45 230/1/50 1,250 kWh 410 445 625 m m m m Kg mm mm R410A 2 2-4 1,2 5,2 39/8,5 800x470x310 435x440x230 R410A 2 2-4 1,2 5,2 40/9,5 800x470x310 435x440x230 R410A 2 2-4 1,2 5,2 41/13 800x470x310 490x525x250 w w w. a r g o c l i m a . c o m Accessories for the outside fixed installation of the case supplied wth the unit The technical data here indicated are in compliance with the European standard EN14511 - Directive 2002/31/EC 17 FLOOR SPLIT R410A improve your life Ulisse 10CL A Floor split air conditioner realized in only 24 cm of depht, suitable for fixed or moveable installations Small condensing case, specifically projected to be placed on balcony or window Infrared remote control with 4 digital timers to be set on the 24h and week-end, night set back, start-up of air-conditioning or dehumidifying or ventilation only modes, temperature digital adjustment and room temperature control by a special sensor inside the remote control Double temperature sensor (on remote control / on indoor unit) "I Feel" feature Dry function Three-speed fan by remote control Frontal air-intake, making possible its placement even between two walls Automatic condensate vaporization through the case AeroQuip quick connectors to easily disconnect and re-connect the outdoor unit for a fixed installation REMOTE CONTROL Adjustable air louver, granting the best fresh air diffusion Anti-mould and anti-bacteria washable filters Auto restart after a power supply black out Electronic protection against over-pressures Infrared remote control with temperature sensor High efficiency rotary compressor Accessories for the outside fixed installation of the case supplied wth the unit w w w. a r g o c l i m a . c o m Optional pipe-extension kits connecting Indoor and Outdoor units (2 and 4m) 18 Technical data PRODUCT NAME Features Cooling capacity Energy label class E.E.R. Air flowrate (h.l.) Dehumidification Fan speeds (Indoor / Outdoor) Sound pressure Indoor (h.m.l.) Sound pressure Outdoor (h.) Power supply Running consumption Annual energy consumption-cooling mode(500h)-Dir. 2002/31/CE Refrigerant type Standard pipe lenght Additional pipe lenght Max. height between units (Outdoor on the top) Max. height between units (Indoor on the top) Net weight Indoor / Outdoor Net dimension Indoor (H./W./D.) Net dimension Outdoor (H./W./D.) Units kW BTU/h kcal/h ABCDEFG (kW/kW) m3/h l/h n° dB(A) dB(A) V/Ph/Hz kW kWh m m m m Kg mm mm ULISSE 10CLA Cooling 2,98 10.160 2.560 A 3,22 370 1,2 3 + Auto / 1 36-33-32 47 230/1/50 0,925 463 R410A 2 2-4 1,2 5,2 44/9,5 790x580x245 435x440x230 The technical data here indicated are in compliance with the European standard EN14511 - Directive 2002/31/EC FLOOR SPLIT R410A improve your life Ulisse 13 CL A Floor split air conditioner realized in only 24 cm of depht, suitable for fixed or moveable installations Small condensing case, specifically projected to be placed on balcony or window Infrared remote control with 4 digital timers to be set on the 24h and week-end, night set back, start-up of air-conditioning or dehumidifying or ventilation only modes, temperature digital adjustment and room temperature control by a special sensor inside the remote control Double temperature sensor (on remote control / on indoor unit) "I Feel" feature Dry function Three-speed fan by remote control Frontal air-intake, making possible its placement even between two walls Automatic condensate vaporization through the case AeroQuip quick connectors to easily disconnect and re-connect the outdoor unit for a fixed installation REMOTE CONTROL Adjustable air louver, granting the best fresh air diffusion Anti-mould and anti-bacteria washable filters Auto restart after a power supply black out Electronic protection against over-pressures Infrared remote control with temperature sensor High efficiency rotary compressor Accessories for the outside fixed installation of the case supplied wth the unit Technical data PRODUCT NAME Features Cooling capacity Energy label class E.E.R. Air flowrate (h.l.) Dehumidification Fan speeds (Indoor / Outdoor) Sound pressure Indoor (h.m.l.) Sound pressure Outdoor (h.) Power supply Running consumption Annual energy consumption-cooling mode(500h)-Dir. 2002/31/CE Refrigerant type Standard pipe lenght Additional pipe lenght Max. height between units (Outdoor on the top) Max. height between units (Indoor on the top) Net weight Indoor / Outdoor Net dimension Indoor (H./W./D.) Net dimension Outdoor (H./W./D.) Units kW BTU/h kcal/h ABCDEFG (kW/kW) m3/h l/h n° dB(A) dB(A) V/Ph/Hz kW kWh m m m m Kg mm mm ULISSE 13CLA Cooling 3,98 13.570 3.420 A 3,21 450 1,5 3 + Auto / 1 37-34-33 45 230/1/50 1,240 620 R410A 2 2-4 1,2 5,2 44/15 790x580x245 490x525x250 The technical data here indicated are in compliance with the European standard EN14511 - Directive 2002/31/EC w w w. a r g o c l i m a . c o m Optional pipe-extension kits connecting Indoor and Outdoor units (2 and 4m) 19 FLOOR SPLIT R410A improve your life Ulisse 10 HL A Floor split straight cooling and heat pump air conditioner Realized in only 24 cm of depht, suitable for fixed or moveable floor installations Small condensing case, specifically projected to be placed on balcony or window Infrared remote control with 4 digital timers to be set on the 24h and week-end, night set back, start-up of air-conditioning or dehumidifying or ventilation only modes, temperature digital adjustment and room temperature control by a special sensor inside the remote control Double temperature sensor (on remote control / on indoor unit) “I Feel" feature Dry function Three-speed fan by remote control Frontal air-intake, making possible its placement even between two walls REMOTE CONTROL Automatic condensate vaporization through the case AeroQuip quick connectors to easily disconnect and re-connect the outdoor unit for a fixed installation Adjustable air louver, granting the best fresh air diffusion Anti-mould and anti-bacteria washable filters Auto restart after a power supply black out Infrared remote control with temperature sensor Electronic protection against over-pressures High efficiency rotary compressor Accessories for the outside fixed installation of the case supplied wth the unit w w w. a r g o c l i m a . c o m Optional pipe-extension kits connecting Indoor and Outdoor units (2 and 4m) 20 Dati tecnici PRODUCT NAME Features Cooling capacity Energy label class E.E.R. Air flowrate (h.l.) Dehumidification Fan speeds (Indoor / Outdoor) Sound pressure Indoor (h.m.l.) Sound pressure Outdoor (h.) Power supply Running consumption Annual energy consumption-cooling mode(500h)-Dir. 2002/31/CE Refrigerant type Standard pipe lenght Additional pipe lenght Max. height between units (Outdoor on the top) Max. height between units (Indoor on the top) Net weight Indoor / Outdoor Net dimension Indoor (H./W./D.) Net dimension Outdoor (H./W./D.) Units kW BTU/h kcal/h ABCDEFG (kW/kW) m3/h l/h n° dB(A) dB(A) V/Ph/Hz kW kWh m m m m Kg mm mm ULISSE 10HLA Raffrescamento Riscaldamento 2,98 3,34 10.160 11.390 2.560 2.870 A A 3,22 3,67 370 1,2 3 + Auto / 1 36-33-32 45 230/1/50 0,925 0,910 463 R410A 2 2-4 1,2 5,2 44/15 790x580x245 490x525x250 The technical data here indicated are in compliance with the European standard EN14511 - Directive 2002/31/EC SPLIT ON-OFF R410A w w w. a r g o c l i m a . c o m improve your life HIGH WALL - ON/OFF R410A improve your life AW22 AC/ACL/AH PRODUCT NAME Indoor unit Outdoor unit Features Cooling/Heating capacity Energy label class E.E.R. / C.O.P. Air flowrate Indoor (h.m.l.) Dehumidification Fan speeds (Indoor / Outdoor) Sound pressure Indoor (h.m.l.) Sound pressure Outdoor (h.) Power supply Running consumption Annual energy cons.- cooling mode (500h) - Directive 2002/31/CE Compressor type Refrigerant type Liquid pipe diameter Gas pipe diameter Max. pipe lenght with gas standard charge Max. pipe lenght with gas additional charge Gas additional charge Max. height between units (Outdoor on top) Max. height between units (Indoor on top) Net weight Indoor / Outdoor Net dimension Indoor (H./W./D.) Net dimension Outdoor (H./W./D.) h h ld h d d l AW22AL AE22AC Cooling Heating 2,32 7.920 2.000 A 3,41 380-320-280 0,8 3 + Auto/1 36-32-30 36 230/1/50 0,680 - Units kW BTU/h kcal/h ABCDEFG (kW/kW) m3/h l/h n° dB(A) dB(A) V/Ph/Hz kW kWh 340 mm(inch") mm(inch") m m gr/m m m Kg mm mm h h d - Rotary R410A 6,35(1/4") 9,52(3/8") 7,5 15 15 7 7 11/31 285x810x190 610x795x290 d AW22AL AE22ACL Cooling Heating 2,32 7.920 2.000 A 3,41 380-320-280 0,8 3 + Auto/1 36-32-30 36 230/1/50 0,680 340 - Rotary R410A 6,35(1/4") 9,52(3/8") 7,5 15 15 7 7 11/31 285x810x190 610x795x290 2002/3 / The technical data here indicated are in compliance with the European standard EN14511 - Directive 2002/31/EC Features Straight cooling and heat pump air conditioner, available in standard and low ambient mode (up to -10°C) Automatic change-over between cooling and heating modes (AW22AH) w w w. a r g o c l i m a . c o m Infrared remote control with 4 digital timers to be set on the 24h and week-end management 22 Double temperature sensor (on remote control / on indoor unit) "I Feel" feature, granting the best comfort conditions Dry function Three-speed tangential fan by remote control Night set back capability Heating function disabled during defrosting cycle (AW22AH) Horizontal flap swinging or to be set to a fixed position by remote control Vertical flap by manual control Anti-mould and anti-bacteria washable filters Auto restart after a power supply black out Electronic protection against over-pressures High efficiency rotary compressor AW22AL AE22AH Cooling Heating 2,32 2,44 7.920 8.320 2.000 2.095 A A 3,41 3,67 380-320-280 0,8 3 + Auto/1 36-32-30 37 230/1/50 0,680 0,665 340 - Rotary R410A 6,35(1/4") 9,52(3/8") 7,5 15 15 7 7 11/32 285x810x190 610x795x290 HIGH WALL - ON/OFF R410A improve your life AW28 AC/ACL/AH PRODUCT NAME Indoor unit Outdoor unit Features Cooling/Heating capacity Energy label class E.E.R. / C.O.P. Air flowrate Indoor (h.m.l.) Dehumidification Fan speeds (Indoor / Outdoor) Sound pressure Indoor (h.m.l.) Sound pressure Outdoor (h.) Power supply Running consumption Annual energy cons.- cooling mode (500h) - Directive 2002/31/CE Compressor type Refrigerant type Liquid pipe diameter Gas pipe diameter Max. pipe lenght with gas standard charge Max. pipe lenght with gas additional charge Gas additional charge Max. height between units (Outdoor on top) Max. height between units (Indoor on top) Net weight Indoor / Outdoor Net dimension Indoor (H./W./D.) Net dimension Outdoor (H./W./D.) Units kW BTU/h kcal/h ABCDEFG (kW/kW) m3/h l/h n° dB(A) dB(A) V/Ph/Hz kW kWh mm(inch") mm(inch") m m gr/m m m Kg mm mm AW28AL AE28AC Cooling Heating 2,75 9.380 2.370 A 3,44 450-380-330 1,1 3 + Auto/1 40-37-35 38 230/1/50 0,800 400 Rotary R410A 6,35(1/4") 9,52(3/8") 7,5 15 10 7 7 11/34 285x810x190 610x795x290 AW28AL AE28ACL Cooling Heating 2,75 9.380 2.370 A 3,44 450-380-330 1,1 3 + Auto/1 40-37-35 38 230/1/50 0,800 400 Rotary R410A 6,35(1/4") 9,52(3/8") 7,5 15 10 7 7 11/34 285x810x190 610x795x290 AW28AL AE28AH Cooling Heating 2,75 2,85 9.380 9.720 2.370 2.460 A D 3,44 3,20 450-380-330 1,1 3 + Auto/1 40-37-35 40 230/1/50 0,880 0,890 400 Rotary R410A 6,35(1/4") 9,52(3/8") 7,5 15 10 7 7 11/35 285x810x190 610x795x290 The technical data here indicated are in compliance with the European standard EN14511 - Directive 2002/31/EC Features Straight cooling and heat pump air conditioner, available in standard and low ambient mode (up to -10°C) Automatic change-over between cooling and heating modes (AW28AH) Double temperature sensor (on remote control / on indoor unit) "I Feel" feature, granting the best comfort conditions Dry function Three-speed tangential fan by remote control Night set back capability Heating function disabled during defrosting cycle (AW28AH) Horizontal flap swinging or to be set to a fixed position by remote control Vertical flap by manual control Anti-mould and anti-bacteria washable filters Auto restart after a power supply black out Electronic protection against over-pressures High efficiency rotary compressor w w w. a r g o c l i m a . c o m Infrared remote control with 4 digital timers to be set on the 24h and week-end management 23 HIGH WALL - ON/OFF R410A improve your life AW38 AC/ACL/AH PRODUCT NAME Indoor unit Outdoor unit Features Cooling/Heating capacity Energy label class E.E.R. / C.O.P. Air flowrate Indoor (h.m.l.) Dehumidification Fan speeds (Indoor / Outdoor) Sound pressure Indoor (h.m.l.) Sound pressure Outdoor (h.) Power supply Running consumption Annual energy cons.- cooling mode (500h) - Directive 2002/31/CE Compressor type Refrigerant type Liquid pipe diameter Gas pipe diameter Max. pipe lenght with gas standard charge Max. pipe lenght with gas additional charge Gas additional charge Max. height between units (Outdoor on top) Max. height between units (Indoor on top) Net weight Indoor / Outdoor Net dimension Indoor (H./W./D.) Net dimension Outdoor (H./W./D.) Units kW BTU/h kcal/h ABCDEFG (kW/kW) m3/h l/h n° dB(A) dB(A) V/Ph/Hz kW kWh mm(inch") mm(inch") m m gr/m m m Kg mm mm AW38AL AE38AC Cooling Heating 3,63 12.380 3.120 A 3,26 635-550-450 1,5 3 + Auto/1 47-44-40 42 230/1/50 1,115 558 Rotary R410A 6,35(1/4") 9,52(3/8") 7,5 15 12 7 7 11/35 285x810x190 610x795x290 AW38AL AE38ACL Cooling Heating 3,63 12.380 3.120 A 3,26 635-550-450 1,5 3 + Auto/1 47-44-40 42 230/1/50 1,115 558 Rotary R410A 6,35(1/4") 9,52(3/8") 7,5 15 12 7 7 11/35 285x810x190 610x795x290 The technical data here indicated are in compliance with the European standard EN14511 - Directive 2002/31/EC Features Straight cooling and heat pump air conditioner, available in standard and low ambient mode (up to -10°C) Automatic change-over between cooling and heating modes (AW38AH) w w w. a r g o c l i m a . c o m Infrared remote control with 4 digital timers to be set on the 24h and week-end management 24 Double temperature sensor (on remote control / on indoor unit) "I Feel" feature, granting the best comfort conditions Dry function Three-speed tangential fan by remote control Night set back capability Heating function disabled during defrosting cycle (AW38AH) Horizontal flap swinging or to be set to a fixed position by remote control Vertical flap by manual control Anti-mould and anti-bacteria washable filters Auto restart after a power supply black out Electronic protection against over-pressures High efficiency rotary compressor AW38AL AE38AH Cooling Heating 3,63 4,00 12.380 13.640 3.120 3.440 A B 3,26 3,51 635-550-450 1,5 3 + Auto/1 47-44-40 44 230/1/50 1,115 1,140 558 Rotary R410A 6,35(1/4") 9,52(3/8") 7,5 15 12 7 7 11/36 285x810x190 610x795x290 HIGH WALL - ON/OFF R410A improve your life AW42 AC/ACL/AH PRODUCT NAME Indoor unit Outdoor unit Features Cooling/Heating capacity Energy label class E.E.R. / C.O.P. Air flowrate Indoor (h.m.l.) Dehumidification Fan speeds (Indoor / Outdoor) Sound pressure Indoor (h.m.l.) Sound pressure Outdoor (h.) Power supply Running consumption Annual energy cons.- cooling mode (500h) - Directive 2002/31/CE Compressor type Refrigerant type Liquid pipe diameter Gas pipe diameter Max. pipe lenght with gas standard charge Max. pipe lenght with gas additional charge Gas additional charge Max. height between units (Outdoor on top) Max. height between units (Indoor on top) Net weight Indoor / Outdoor Net dimension Indoor (H./W./D.) Net dimension Outdoor (H./W./D.) Units kW BTU/h kcal/h ABCDEFG (kW/kW) m3/h l/h n° dB(A) dB(A) V/Ph/Hz kW kWh mm(inch") mm(inch") m m gr/m m m Kg mm mm AW42AL AE42AC Cooling Heating 4,00 13.640 3.440 B 3,01 660-550-475 1,5 3 + Auto/1 47-42-37 43 230/1/50 1,330 665 Rotary R410A 6,35(1/4") 12,7(1/2") 7,5 15 20 7 7 11,5/41,5 285x810x190 610x795x290 AW42AL AE42ACL Cooling Heating 4,00 13.640 3.440 B 3,01 660-550-475 1,5 3 + Auto/1 47-42-37 43 230/1/50 1,330 665 Rotary R410A 6,35(1/4") 12,7(1/2") 7,5 15 20 7 7 11,5/41,5 285x810x190 610x795x290 AW42AL AE42AH Cooling Heating 4,00 4,48 13.640 15.280 3.440 3.850 B C 3,01 3,21 660-550-475 1,5 3 + Auto/1 47-42-37 44 230/1/50 1,330 1,395 665 Rotary R410A 6,35(1/4") 12,7(1/2") 7,5 15 20 7 7 11,5/42 285x810x190 610x795x290 The technical data here indicated are in compliance with the European standard EN14511 - Directive 2002/31/EC Features Straight cooling and heat pump air conditioner, available in standard and low ambient mode (up to -10°C) Automatic change-over between cooling and heating modes (AW42AH) Double temperature sensor (on remote control / on indoor unit) "I Feel" feature, granting the best comfort conditions Dry function Three-speed tangential fan by remote control Night set back capability Heating function disabled during defrosting cycle (AW42AH) Horizontal flap swinging or to be set to a fixed position by remote control Vertical flap by manual control Anti-mould and anti-bacteria washable filters Auto restart after a power supply black out Electronic protection against over-pressures High efficiency rotary compressor w w w. a r g o c l i m a . c o m Infrared remote control with 4 digital timers to be set on the 24h and week-end management 25 HIGH WALL - ON/OFF R410A improve your life AW52 AC/ACL/AH PRODUCT NAME Indoor unit Outdoor unit Features Cooling/Heating capacity Energy label class E.E.R. / C.O.P. Air flowrate Indoor (h.m.l.) Dehumidification Fan speeds (Indoor / Outdoor) Sound pressure Indoor (h.m.l.) Sound pressure Outdoor (h.) Power supply Running consumption Annual energy cons.- cooling mode (500h) Directive 2002/31/CE Compressor type Refrigerant type Liquid pipe diameter Gas pipe diameter Max. pipe lenght with gas standard charge Max. pipe lenght with gas additional charge Gas additional charge Max. height between units (Outdoor on top) Max. height between units (Indoor on top) Net weight Indoor / Outdoor Net dimension Indoor (H./W./D.) Units kW BTU/h kcal/h ABCDEFG (kW/kW) m3/h l/h n° dB(A) dB(A) V/Ph/Hz kW AW52AL AE52AC Cooling Heating 5,50 18760 4.730 A 3,22 930-840-750 1,8 3 + Auto/1 47-44-41 48 230/1/50 1,690 - kWh 845 mm(inch") mm(inch") m m gr/m m m Kg mm - AW52AL AE52ACL Cooling Heating 5,50 18760 4.730 A 3,22 930-840-750 1,8 3 + Auto/1 47-44-41 48 230/1/50 1,690 845 Rotary R410A 6,35(1/4") 12,7(1/2") 10 25 20 15 15 14/56 295x1060x210 - Rotary R410A 6,35(1/4") 12,7(1/2") 10 25 20 15 15 14/56 295x1060x210 The technical data here indicated are in compliance with the European standard EN14511 - Directive 2002/31/EC Features Straight cooling and heat pump air conditioner, available in standard and low ambient mode (up to -10°C) Automatic change-over between cooling and heating modes (AW52AH) w w w. a r g o c l i m a . c o m Infrared remote control with 4 digital timers to be set on the 24h and week-end management 26 Double temperature sensor (on remote control / on indoor unit) "I Feel" feature, granting the best comfort conditions Dry function Three-speed tangential fan by remote control Night set back capability Heating function disabled during defrosting cycle (AW52AH) Horizontal flap swinging or to be set to a fixed position by remote control Vertical flap by manual control Anti-mould and anti-bacteria washable filters Auto restart after a power supply black out Electronic protection against over-pressures High efficiency rotary compressor AW52AL AE52AH Cooling Heating 5,50 5,56 18.760 18.960 4.730 4.780 A B 3,22 3,46 930-840-750 1,8 3 + Auto/1 42-39-34 48 230/1/50 1,690 1,600 845 - Rotary R410A 6,35(1/4") 12,7(1/2) 10 25 20 15 15 14/56 295x1060x210 HIGH WALL - ON/OFF R410A improve your life AW52 AC3/ACL3/AH3 PRODUCT NAME Indoor unit Outdoor unit Features Cooling/Heating capacity Energy label class E.E.R. / C.O.P. Air flowrate Indoor (h.m.l.) Dehumidification Fan speeds (Indoor / Outdoor) Sound pressure Indoor (h.m.l.) Sound pressure Outdoor (h.) Power supply Running consumption Annual energy cons.- cooling mode (500h) Directive 2002/31/CE Compressor type Refrigerant type Liquid pipe diameter Gas pipe diameter Max. pipe lenght with gas standard charge Max. pipe lenght with gas additional charge Gas additional charge Max. height between units (Outdoor on top) Max. height between units (Indoor on top) Net weight Indoor / Outdoor Net dimension Indoor (H./W./D.) Units kW BTU/h kcal/h ABCDEFG (kW/kW) m3/h l/h n° dB(A) dB(A) V/Ph/Hz kW kWh AW52AL AE52AC3 Cooling Heating 5,50 18760 4.730 A 3,22 930-840-750 1,8 3 + Auto/1 47-44-41 48 400/3/50 1,690 845 mm(inch") mm(inch") m m gr/m m m Kg mm - Rotary R410A 6,35(1/4") 12,7(1/2") 10 25 20 15 15 14/56 295x1060x210 AW52AL AE52ACL3 Cooling Heating 5,50 18760 4.730 A 3,22 930-840-750 1,8 3 + Auto/1 47-44-41 48 400/3/50 1,690 845 - Rotary R410A 6,35(1/4") 12,7(1/2") 10 25 20 15 15 14/56 295x1060x210 AW52AL AE52AH3 Cooling Heating 5,50 5,56 18.760 18.960 4.730 4.780 A B 3,22 3,46 930-840-750 1,8 3 + Auto/1 47-44-41 48 400/3/50 1,690 1,600 845 - Rotary R410A 6,35(1/4") 12,7(1/2) 10 25 20 15 15 14/56 295x1060x210 The technical data here indicated are in compliance with the European standard EN14511 - Directive 2002/31/EC Features Straight cooling and heat pump air conditioner, available in standard and low ambient mode (up to -10°C) Three phase power supply (400/3N/50) Infrared remote control with 4 digital timers to be set on the 24h and week-end management Double temperature sensor (on remote control / on indoor unit) "I Feel" feature, granting the best comfort conditions Dry function Three-speed tangential fan by remote control Night set back capability Heating function disabled during defrosting cycle (AW52AH3) Horizontal flap swinging or to be set to a fixed position by remote control Vertical flap by manual control Anti-mould and anti-bacteria washable filters Auto restart after a power supply black out Electronic protection against over-pressures w w w. a r g o c l i m a . c o m Automatic change-over between cooling and heating modes (AW52AH3) High efficiency rotary compressor 27 HIGH WALL - ON/OFF R410A improve your life AW64 AC/ACL/AH PRODUCT NAME Indoor unit Outdoor unit Features Cooling/Heating capacity Energy label class E.E.R. / C.O.P. Air flowrate Indoor (h.m.l.) Dehumidification Fan speeds (Indoor / Outdoor) Sound pressure Indoor (h.m.l.) Sound pressure Outdoor (h.) Power supply Running consumption Annual energy cons.- cooling mode (500h) Directive 2002/31/CE Compressor type Refrigerant type Liquid pipe diameter Gas pipe diameter Max. pipe lenght with gas standard charge Max. pipe lenght with gas additional charge Gas additional charge Max. height between units (Outdoor on top) Max. height between units (Indoor on top) Net weight Indoor / Outdoor Net dimension Indoor (H./W./D.) Units kW BTU/h kcal/h ABCDEFG (kW/kW) m3/h l/h n° dB(A) dB(A) V/Ph/Hz kW AW64AL AE64AC Cooling Heating 6,81 23.220 5.860 B 3,01 990-930-840 2,66 3 + Auto/1 49-46-44 47 230/1/50 2,260 - kWh 1130 mm(inch") mm(inch") m m gr/m m m Kg mm - AW64AL AE64ACL Cooling Heating 6,81 23.220 5.860 B 3,01 990-930-840 2,66 3 + Auto/1 49-46-44 47 230/1/50 2,260 1130 Rotary R410A 9,52(3/8") 15,88(5/8") 12,5 20 20 15 15 15/74 295x1060x210 - Rotary R410A 9,52(3/8") 15,88(5/8") 12,5 20 20 15 15 15/74 295x1060x210 The technical data here indicated are in compliance with the European standard EN14511 - Directive 2002/31/EC Features Straight cooling and heat pump air conditioner, available in standard and low ambient mode (up to -10°C) Automatic change-over between cooling and heating modes (AW64AH) w w w. a r g o c l i m a . c o m Infrared remote control with 4 digital timers to be set on the 24h and week-end management 28 Double temperature sensor (on remote control / on indoor unit) "I Feel" feature, granting the best comfort conditions Dry function Three-speed tangential fan by remote control Night set back capability Heating function disabled during defrosting cycle (AW64AH) Horizontal flap swinging or to be set to a fixed position by remote control Vertical flap by manual control Anti-mould and anti-bacteria washable filters Auto restart after a power supply black out Electronic protection against over-pressures High efficiency rotary compressor AW64AL AE64AH Cooling Heating 6,81 7,37 23.220 25.130 5.860 6.340 B D 3,01 3,07 990-930-840 2,66 3 + Auto/1 49-46-44 47 230/1/50 2,260 2,400 1130 - Rotary R410A 9,52(3/8") 15,88(5/8") 12,5 20 20 15 15 15/74 295x1060x210 HIGH WALL - ON/OFF R410A improve your life AW64 AC3/ACL3/AH3 PRODUCT NAME Indoor unit Outdoor unit Features Cooling/Heating capacity Energy label class E.E.R. / C.O.P. Air flowrate Indoor (h.m.l.) Dehumidification Fan speeds (Indoor / Outdoor) Sound pressure Indoor (h.m.l.) Sound pressure Outdoor (h.) Power supply Running consumption Annual energy cons.- cooling mode (500h) Directive 2002/31/CE Compressor type Refrigerant type Liquid pipe diameter Gas pipe diameter Max. pipe lenght with gas standard charge Max. pipe lenght with gas additional charge Gas additional charge Max. height between units (Outdoor on top) Max. height between units (Indoor on top) Net weight Indoor / Outdoor Net dimension Indoor (H./W./D.) Units kW BTU/h kcal/h ABCDEFG (kW/kW) m3/h l/h n° dB(A) dB(A) V/Ph/Hz kW kWh mm(inch") mm(inch") m m gr/m m m Kg mm AW64AL AE64AC3 Cooling Heating 6,81 23.220 5.860 B 3,01 990-930-840 2,66 3 + Auto/1 49-46-44 47 400/3/50 2,260 1130 - Rotary R410A 9,52(3/8") 15,88(5/8") 12,5 20 20 15 15 15/74 295x1060x210 AW64AL AE64ACL3 Cooling Heating 6,81 23.220 5.860 B 3,01 990-930-840 2,66 3 + Auto/1 49-46-44 47 400/3/50 2,260 1130 - Rotary R410A 9,52(3/8") 15,88(5/8") 12,5 20 20 15 15 15/74 295x1060x210 AW64AL AE64AH3 Cooling Heating 6,81 7,37 23.220 25.130 5.860 6.340 B D 3,01 3,07 990-930-840 2,66 3 + Auto/1 49-46-44 47 400/3/50 2,260 2,400 1130 - Rotary R410A 9,52(3/8") 15,88(5/8") 12,5 20 20 15 15 15/74 295x1060x210 The technical data here indicated are in compliance with the European standard EN14511 - Directive 2002/31/EC Features Straight cooling and heat pump air conditioner, available in standard and low ambient mode (up to -10°C) Three phase power supply (400/3N/50) Infrared remote control with 4 digital timers to be set on the 24h and week-end management Double temperature sensor (on remote control / on indoor unit) "I Feel" feature, granting the best comfort conditions Dry function Three-speed tangential fan by remote control Night set back capability Heating function disabled during defrosting cycle (AW64AH3) Horizontal flap swinging or to be set to a fixed position by remote control Vertical flap by manual control Anti-mould and anti-bacteria washable filters Auto restart after a power supply black out Electronic protection against over-pressures w w w. a r g o c l i m a . c o m Automatic change-over between cooling and heating modes (AW64AH3) High efficiency rotary compressor 29 CASSETTE - ON/OFF R410A improve your life AS28 AC/ACL/AH PRODUCT NAME Indoor unit Outdoor unit Features Cooling/Heating capacity Energy label class E.E.R. / C.O.P. Air flowrate Indoor (h.m.l.) Dehumidification Fan speeds (Indoor / Outdoor) Sound pressure Indoor (h.m.l.) Sound pressure Outdoor (h.) Power supply Running consumption Annual energy cons.- cooling mode (500h) - Directive 2002/31/CE Compressor type Refrigerant type Liquid pipe diameter Gas pipe diameter Max. pipe lenght with gas standard charge Max. pipe lenght with gas additional charge Gas additional charge Max. height between units (Outdoor on top) Max. height between units (Indoor on top) Net weight Indoor / grille / Outdoor Net dimension Indoor (H./W./D.) Net dimension grille (H./W./D.) Net dimension Outdoor (H./W./D.) Units kW BTU/h kcal/h ABCDEFG (kW/kW) m3/h l/h n° dB(A) dB(A) V/Ph/Hz kW kWh mm(inch") mm(inch") m m gr/m m m Kg mm mm mm AS28AL AE28AC Cooling Heating 2,68 9.140 2.300 A 3,21 700-600-500 0,5 3 + Auto / 1 43-39-36 38 230/1/50 0,835 418 Rotary R410A 6,35(1/4") 9,52(3/8") 7,5 15 10 7 7 16,5/2,5/35 273x575x575 64x730x730 610x795x290 AS28AL AE28ACL Cooling Heating 2,68 9.140 2.300 A 3,21 700-600-500 0,5 3 + Auto / 1 43-39-36 38 230/1/50 0,835 418 Rotary R410A 6,35(1/4") 9,52(3/8") 7,5 15 10 7 7 16,5/2,5/35 273x575x575 64x730x730 610x795x290 The technical data here indicated are in compliance with the European standard EN14511 - Directive 2002/31/EC Features Cassette straight cooling and heat pump air conditioner, available in standard and low ambient mode (-10°C) Automatic change-over between cooling and heating modes (AS28AH) w w w. a r g o c l i m a . c o m Infrared remote control with 4 digital timers to be set on the 24h and week-end management Double temperature sensor (on remote control / on indoor unit) "I Feel" feature, granting the best comfort conditions Dry function Three-speed centrifugal fan by remote control Night set back capability Heating function disabled during defrosting cycle (AS28AH) Four horizontal flaps swinging by remote control Anti-mould and anti-bacteria washable filters Integrated pump for condensate discharge Auto restart after a power supply black out Electronic protection against over-pressures Single duct capability to move air conditioned in a near room High efficiency rotary compressor 30 AS28AL AE28AH Cooling Heating 2,68 3,22 9.140 10.980 2.300 2.770 A B 3,21 3,54 700-600-500 0,5 3 + Auto / 1 43-39-36 40 230/1/50 0,835 0,910 418 Rotary R410A 6,35(1/4") 9,52(3/8") 7,5 15 10 7 7 16,5/2,5/35 273x575x575 64x730x730 610x795x290 CASSETTE- ON/OFF R410A improve your life AS38 AC/ACL/AH PRODUCT NAME Indoor unit Outdoor unit Features Cooling/Heating capacity Energy label class E.E.R. / C.O.P. Air flowrate Indoor (h.m.l.) Dehumidification Fan speeds (Indoor / Outdoor) Sound pressure Indoor (h.m.l.) Sound pressure Outdoor (h.) Power supply Running consumption Annual energy cons.- cooling mode (500h) - Directive 2002/31/CE Compressor type Refrigerant type Liquid pipe diameter Gas pipe diameter Max. pipe lenght with gas standard charge Max. pipe lenght with gas additional charge Gas additional charge Max. height between units (Outdoor on top) Max. height between units (Indoor on top) Net weight Indoor / grille / Outdoor Net dimension Indoor (H./W./D.) Net dimension grille (H./W./D.) Net dimension Outdoor (H./W./D.) Units kW BTU/h kcal/h ABCDEFG (kW/kW) m3/h l/h n° dB(A) dB(A) V/Ph/Hz kW kWh mm(inch") mm(inch") m m gr/m m m Kg mm mm mm AS38AL AE38AC Cooling Heating 3,50 11.940 3.010 B 3,07 700-600-500 1,0 3 + Auto / 1 43-39-36 42 230/1/50 1,140 570 Rotary R410A 6,35(1/4") 9,52(3/8") 7,5 15 12 7 7 16,5/2,5/35 273x575x575 64x730x730 610x795x290 AS38AL AE38ACL Cooling Heating 3,50 11.940 3.010 B 3,07 700-600-500 1,0 3 + Auto / 1 43-39-36 42 230/1/50 1,140 570 Rotary R410A 6,35(1/4") 9,52(3/8") 7,5 15 12 7 7 16,5/2,5/35 273x575x575 64x730x730 610x795x290 AS38AL AE38AH Cooling Heating 3,50 3,89 11.940 13.270 3.010 3.345 B D 3,07 3,11 700-600-500 1,0 3 + Auto / 1 43-39-36 44 230/1/50 1,140 1,250 570 Rotary R410A 6,35(1/4") 9,52(3/8") 7,5 15 12 7 7 16,5/2,5/36 273x575x575 64x730x730 610x795x290 The technical data here indicated are in compliance with the European standard EN14511 - Directive 2002/31/EC Features Cassette straight cooling and heat pump air conditioner, available in standard and low ambient mode (-10°C) Automatic change-over between cooling and heating modes (AS38AH) Double temperature sensor (on remote control / on indoor unit) "I Feel" feature, granting the best comfort conditions Dry function Three-speed centrifugal fan by remote control Night set back capability Heating function disabled during defrosting cycle (AS38AH) Four horizontal flaps swinging by remote control Anti-mould and anti-bacteria washable filters Integrated pump for condensate discharge Auto restart after a power supply black out Electronic protection against over-pressures Single duct capability to move air conditioned in a near room w w w. a r g o c l i m a . c o m Infrared remote control with 4 digital timers to be set on the 24h and week-end management High efficiency rotary compressor 31 CASSETTE - ON/OFF R410A improve your life AS52 AC/ACL/AH PRODUCT NAME Indoor unit Outdoor unit Features Cooling/Heating capacity Energy label class E.E.R. / C.O.P. Air flowrate Indoor (h.m.l.) Dehumidification Fan speeds (Indoor / Outdoor) Sound pressure Indoor (h.m.l.) Sound pressure Outdoor (h.) Power supply Running consumption Annual energy cons.- cooling mode (500h) - Directive 2002/31/CE Compressor type Refrigerant type Liquid pipe diameter Gas pipe diameter Max. pipe lenght with gas standard charge Max. pipe lenght with gas additional charge Gas additional charge Max. height between units (Outdoor on top) Max. height between units (Indoor on top) Net weight Indoor / grille / Outdoor Net dimension Indoor (H./W./D.) Net dimension grille (H./W./D.) Net dimension Outdoor (H./W./D.) Units kW BTU/h kcal/h ABCDEFG (kW/kW) m3/h l/h n° dB(A) dB(A) V/Ph/Hz kW kWh AS52AL AE52AC Cooling Heating 5,50 18.760 4.730 A 3,24 750-630-550 2,3 3 + Auto / 1 44-39-36 48 230/1/50 1,700 850 mm(inch") mm(inch") m m gr/m m m Kg mm mm mm - Rotary R410A 6,35(1/4") 12,7(1/2") 10 25 20 15 15 18/2,5/56 273x575x575 64x730x730 690x846x302 AS52AL AE52ACL Cooling Heating 5,50 18.760 4.730 A 3,24 750-630-550 2,3 3 + Auto / 1 44-39-36 48 230/1/50 1,700 850 - Rotary R410A 6,35(1/4") 12,7(1/2") 10 25 20 15 15 18/2,5/56 273x575x575 64x730x730 690x846x302 The technical data here indicated are in compliance with the European standard EN14511 - Directive 2002/31/EC Features Cassette straight cooling and heat pump air conditioner, available in standard and low ambient mode (-10°C) Automatic change-over between cooling and heating modes (AS52AH) w w w. a r g o c l i m a . c o m Infrared remote control with 4 digital timers to be set on the 24h and week-end management Double temperature sensor (on remote control / on indoor unit) "I Feel" feature, granting the best comfort conditions Dry function Three-speed centrifugal fan by remote control Night set back capability Heating function disabled during defrosting cycle (AS52AH) Four horizontal flaps swinging by remote control Anti-mould and anti-bacteria washable filters Integrated pump for condensate discharge Auto restart after a power supply black out Electronic protection against over-pressures Single duct capability to move air conditioned in a near room High efficiency rotary compressor 32 AS52AL AE52AH Cooling Heating 5,50 5,90 18.760 20.120 4.730 5.075 A C 3,24 3,28 750-630-530 2,3 3 + Auto / 1 44-39-36 48 230/1/50 1,700 1,800 850 - Rotary R410A 6,35(1/4") 12,7(1/2") 10 25 20 15 15 18/2,5/56 273x575x575 64x730x730 690x846x302 CASSETTE- ON/OFF R410A improve your life AS52 AC3/ACL3/AH3 PRODUCT NAME Indoor unit Outdoor unit Features Cooling/Heating capacity Energy label class E.E.R. / C.O.P. Air flowrate Indoor (h.m.l.) Dehumidification Fan speeds (Indoor / Outdoor) Sound pressure Indoor (h.m.l.) Sound pressure Outdoor (h.) Power supply Running consumption Annual energy cons.- cooling mode (500h) - Directive 2002/31/CE Compressor type Refrigerant type Liquid pipe diameter Gas pipe diameter Max. pipe lenght with gas standard charge Max. pipe lenght with gas additional charge Gas additional charge Max. height between units (Outdoor on top) Max. height between units (Indoor on top) Net weight Indoor / grille / Outdoor Net dimension Indoor (H./W./D.) Net dimension grille (H./W./D.) Net dimension Outdoor (H./W./D.) Units kW BTU/h kcal/h ABCDEFG (kW/kW) m3/h l/h n° dB(A) dB(A) V/Ph/Hz kW kWh mm(inch") mm(inch") m m gr/m m m Kg mm mm mm AS52AL AE52AC3 Cooling Heating 5,50 18.760 4.730 A 3,24 750-630-550 2,3 3 + Auto / 1 44-39-36 48 400/3/50 1,700 850 - Rotary R410A 6,35(1/4") 12,7(1/2") 10 25 20 15 15 18/2,5/56 273x575x575 64x730x730 690x846x302 AS52AL AE52ACL3 Cooling Heating 5,50 18.760 4.730 A 3,24 750-630-550 2,3 3 + Auto / 1 44-39-36 48 400/3/50 1,700 850 - Rotary R410A 6,35(1/4") 12,7(1/2") 10 25 20 15 15 18/2,5/56 273x575x575 64x730x730 690x846x302 AS52AL AE52AH3 Cooling Heating 5,50 5,90 18.760 20.120 4.730 5.075 A C 3,24 3,28 750-630-530 2,3 3 + Auto / 1 44-39-36 48 400/3/50 1,700 1,800 850 - Rotary R410A 6,35(1/4") 12,7(1/2") 10 25 20 15 15 18/2,5/56 273x575x575 64x730x730 690x846x302 The technical data here indicated are in compliance with the European standard EN14511 - Directive 2002/31/EC Features Cassette straight cooling and heat pump air conditioner, available in standard and low ambient mode (-10°C) Three phase power supply (400/3N/50) Infrared remote control with 4 digital timers to be set on the 24h and week-end management Double temperature sensor (on remote control / on indoor unit) "I Feel" feature, granting the best comfort conditions Dry function Three-speed centrifugal fan by remote control Night set back capability Heating function disabled during defrosting cycle (AS52AH3) Four horizontal flaps swinging by remote control Anti-mould and anti-bacteria washable filters Integrated pump for condensate discharge Auto restart after a power supply black out Electronic protection against over-pressures w w w. a r g o c l i m a . c o m Automatic change-over between cooling and heating modes (AS52AH3) Single duct capability to move air conditioned in a near room High efficiency rotary compressor 33 SPLIT FLOOR - ON/OFF R410A improve your life AF28 AC/ACL/AH PRODUCT NAME Indoor unit Outdoor unit Features Cooling/Heating capacity Energy label class E.E.R. / C.O.P. Air flowrate Indoor (h.m.l.) Dehumidification Fan speeds (Indoor / Outdoor) Sound pressure Indoor (h.m.l.) Sound pressure Outdoor (h.) Power supply Running consumption Annual energy cons.- cooling mode (500h) - Directive 2002/31/CE Compressor type Refrigerant type Liquid pipe diameter Gas pipe diameter Max. pipe lenght with gas standard charge Max. pipe lenght with gas additional charge Gas additional charge Max. height between units (Outdoor on top) Max. height between units (Indoor on top) Net weight Indoor / Outdoor Net dimension Indoor (H./W./D.) Net dimension Outdoor (H./W./D.) Units kW BTU/h kcal/h ABCDEFG (kW/kW) m3/h l/h n° dB(A) dB(A) V/Ph/Hz kW kWh mm(inch") mm(inch") m m gr/m m m Kg mm mm AF28AL AE28AC Cooling Heating 2,66 9.070 2.290 A 3,37 400-360-300 1,0 3 + Auto/1 43-40-34 38 230/1/50 0,790 395 Rotary R410A 6,35(1/4") 9,52(3/8") 7,5 15 10 7 7 18,6/35 700x560x200 610x795x290 AF28AL AE28ACL Cooling Heating 2,66 9.070 2.290 A 3,37 400-360-300 1,0 3 + Auto/1 43-40-34 38 230/1/50 0,790 395 Rotary R410A 6,35(1/4") 9,52(3/8") 7,5 15 10 7 7 18,6/35 700x560x200 610x795x290 The technical data here indicated are in compliance with the European standard EN14511 - Directive 2002/31/EC Features w w w. a r g o c l i m a . c o m Floor straight cooling and heat pump air conditioner, available in standard and low ambient mode (-10°C) Automatic change-over between cooling and heating modes (AF28AH) Infrared remote control with 4 digital timers to be set on the 24h and week-end management Double temperature sensor (on remote control / on indoor unit) "I Feel" feature, granting the best comfort conditions Dry function Three-speed tangential fan by remote control Horizontal and vertical flap by manual control Night set back capability Heating function disabled during defrosting cycle (AF28AH) Anti-mould and anti-bacteria washable filters Auto restart after a power supply black out Electronic protection against over-pressures High efficiency rotary compressor 34 AF28AL AE28AH Cooling Heating 2,66 3,04 9.070 10.370 2.290 2.615 A C 3,37 3,34 400-360-300 1,0 3 + Auto/1 43-40-34 40 230/1/50 0,790 0,910 395 Rotary R410A 6,35(1/4") 9,52(3/8") 7,5 15 10 7 7 18,6/35 700x560x200 610x795x290 FLOOR/CEILING - ON/OFF R410A improve your life FC38 AC/ACL/AH PRODUCT NAME Indoor unit Outdoor unit Features C ooling/Heating capacity Energy label class E.E.R. / C .O.P. Air flowrate Indoor (h.m.l.) Dehumidification Fan speeds (Indoor / Outdoor) Sound pressure Indoor (h.m.l.) Sound pressure Outdoor (h.) Power supply Running consumption Annual energy cons.- cooling mode (500h) - Directive 2002/3 C ompressor type Refrigerant type Liquid pipe diameter Gas pipe diameter Max. pipe lenght with gas standard charge Max. pipe lenght with gas additional charge Gas additional charge Max. height between units (Outdoor on top) Max. height between units (Indoor on top) Net weight Indoor / Outdoor Net dimension Indoor (H./W./D.) Net dimension Outdoor (H./W./D.) Units kW BTU/h kcal/h ABC DEFG (kW/kW) m3/h l/h n° dB(A) dB(A) V/Ph/Hz kW kWh mm(inch") mm(inch") m m gr/m m m Kg mm mm FC 38AL AE38AC C ooling Heating 3,60 12.280 3.096 A 3,21 700-590-500 1,3 3 + Auto / 1 47-43-38 42 230/1/50 1,120 560 Rotary R410A 6,35(1/4") 9,52(3/8") 7,5 15 12 7 7 23,5/36 680x900x190 610x795x290 FC 38AL AE38AC L C ooling Heating 3,60 12.280 3.096 A 3,21 700-590-500 1,3 3 + Auto / 1 47-43-38 42 230/1/50 1,120 560 Rotary R410A 6,35(1/4") 9,52(3/8") 7,5 15 12 7 7 23,5/36 680x900x190 610x795x290 FC 38AL AE38AH C ooling Heating 3,60 4,00 12.280 13.640 3.096 3.440 A C 3,21 3,23 700-590-500 1,3 3 + Auto / 1 47-43-38 44 230/1/50 1,120 1,240 560 Rotary R410A 6,35(1/4") 9,52(3/8") 7,5 15 12 7 7 23,5/36 680x900x190 610x795x290 The technical data here indicated are in compliance with the European standard EN14511 - Directive 2002/31/EC Features Automatic change-over between cooling and heating modes (FC38AH) Infrared remote control with 4 digital timers to be set on the 24h and week-end management Double temperature sensor (on remote control / on indoor unit) "I Feel" feature, granting the best comfort conditions Dry function Three-speed centrifugal fan by remote control Horizontal flap swinging by remote control Vertical flap by manual control Night set back capability Heating function disabled during defrosting cycle (FC38AH) Anti-mould and anti-bacteria washable filters Auto restart after a power supply black out Electronic protection against over-pressures w w w. a r g o c l i m a . c o m Floor/Ceiling straight cooling and heat pump air conditioner, available in standard and low ambient mode (-10°C) High efficiency rotary compressor 35 FLOOR/CEILING - ON/OFF R410A improve your life FC52 AC/ACL/AH PRODUCT NAME Indoor unit Outdoor unit Features Cooling/Heating capacity Energy label class E.E.R. / C.O.P. Air flowrate Indoor (h.m.l.) Dehumidification Fan speeds (Indoor / Outdoor) Sound pressure Indoor (h.m.l.) Sound pressure Outdoor (h.) Power supply Running consumption Annual energy cons.- cooling mode (500h) - Directive 2002/31/CE Compressor type Refrigerant type Liquid pipe diameter Gas pipe diameter Max. pipe lenght with gas standard charge Max. pipe lenght with gas additional charge Gas additional charge Max. height between units (Outdoor on top) Max. height between units (Indoor on top) Net weight Indoor / Outdoor Net dimension Indoor (H./W./D.) Net dimension Outdoor (H./W./D.) Units kW BTU/h kcal/h ABCDEFG (kW/kW) m3/h l/h n° dB(A) dB(A) V/Ph/Hz kW kWh mm(inch") mm(inch") m m gr/m m m Kg mm mm FC52AL AE52AC Cooling Heating 5,65 19.270 4.860 A 3,32 800-700-590 2,3 3 + Auto / 1 51-47-43 48 230/1/50 1,700 850 FC52AL AE52ACL Cooling Heating 5,65 19.270 4.860 A 3,32 800-700-590 2,3 3 + Auto / 1 51-47-43 48 230/1/50 1,700 - - Rotary R410A 6,35(1/4") 12,7(1/2") 10 25 20 15 15 23,5/56 680x900x190 690x846x302 850 - Rotary R410A 6,35(1/4") 12,7(1/2") 10 25 20 15 15 23,5/56 680x900x190 690x846x302 The technical data here indicated are in compliance with the European standard EN14511 - Directive 2002/31/EC Features w w w. a r g o c l i m a . c o m Floor/Ceiling straight cooling and heat pump air conditioner, available in standard and low ambient mode (-10°C) Automatic change-over between cooling and heating modes (FC52AH) Infrared remote control with 4 digital timers to be set on the 24h and week-end management Double temperature sensor (on remote control / on indoor unit) "I Feel" feature, granting the best comfort conditions Dry function Three-speed centrifugal fan by remote control Horizontal flap swinging by remote control Vertical flap by manual control Night set back capability Heating function disabled during defrosting cycle (FC52AH) Anti-mould and anti-bacteria washable filters Auto restart after a power supply black out Electronic protection against over-pressures High efficiency rotary compressor 36 FC52AL AE52AH Cooling Heating 5,65 6,00 19.270 20.460 4.860 5.160 A C 3,32 3,35 800-700-590 2,3 3 + Auto / 1 51-47-43 48 230/1/50 1,700 1,790 850 - Rotary R410A 6,35(1/4") 12,7(1/2") 10 25 20 15 15 23,5/56 680x900x190 690x846x302 FLOOR/CEILING - ON/OFF R410A improve your life FC52 AC3/ACL3/AH3 PRODUCT NAME Indoor unit Outdoor unit Features Cooling/Heating capacity Energy label class E.E.R. / C.O.P. Air flowrate Indoor (h.m.l.) Dehumidification Fan speeds (Indoor / Outdoor) Sound pressure Indoor (h.m.l.) Sound pressure Outdoor (h.) Power supply Running consumption Annual energy cons.- cooling mode (500h) - Directive 2002/31/CE Compressor type Refrigerant type Liquid pipe diameter Gas pipe diameter Max. pipe lenght with gas standard charge Max. pipe lenght with gas additional charge Gas additional charge Max. height between units (Outdoor on top) Max. height between units (Indoor on top) Net weight Indoor / Outdoor Net dimension Indoor (H./W./D.) Net dimension Outdoor (H./W./D.) Units kW BTU/h kcal/h ABCDEFG (kW/kW) m3/h l/h n° dB(A) dB(A) V/Ph/Hz kW kWh FC52AL AE52AC3 Cooling Heating 5,65 19.270 4.860 A 3,32 800-700-590 2,3 3 + Auto / 1 51-47-43 48 400/3/50 1,700 850 mm(inch") mm(inch") m m gr/m m m Kg mm mm - Rotary R410A 6,35(1/4") 12,7(1/2") 10 25 20 15 15 23,5/56 680x900x190 690x846x302 FC52AL AE52ACL3 Cooling Heating 5,65 19.270 4.860 A 3,32 800-700-590 2,3 3 + Auto / 1 51-47-43 48 400/3/50 1,700 850 - Rotary R410A 6,35(1/4") 12,7(1/2") 10 25 20 15 15 23,5/56 680x900x190 690x846x302 FC52AL AE52AH3 Cooling Heating 5,65 6,00 19.270 20.460 4.860 5.160 A C 3,32 3,35 800-700-590 2,3 3 + Auto / 1 51-47-43 48 400/3/50 1,700 1,790 850 - Rotary R410A 6,35(1/4") 12,7(1/2") 10 25 20 15 15 23,5/56 680x900x190 690x846x302 The technical data here indicated are in compliance with the European standard EN14511 - Directive 2002/31/EC Features Three phase power supply (400/3N/50) Automatic change-over between cooling and heating modes (FC52AH3) Infrared remote control with 4 digital timers to be set on the 24h and week-end management Double temperature sensor (on remote control / on indoor unit) "I Feel" feature, granting the best comfort conditions Dry function Three-speed centrifugal fan by remote control Horizontal flap swinging by remote control Vertical flap by manual control Night set back capability Heating function disabled during defrosting cycle (FC52AH3) Anti-mould and anti-bacteria washable filters Auto restart after a power supply black out Electronic protection against over-pressures w w w. a r g o c l i m a . c o m Floor/Ceiling straight cooling and heat pump air conditioner, available in standard and low ambient mode (-10°C) High efficiency rotary compressor 37 FLOOR/CEILING - ON/OFF R410A improve your life FC64 AC/ACL/AH PRODUCT NAME Indoor unit Outdoor unit Features Cooling/Heating capacity Energy label class E.E.R. / C.O.P. Air flowrate Indoor (h.m.l.) Dehumidification Fan speeds (Indoor / Outdoor) Sound pressure Indoor (h.m.l.) Sound pressure Outdoor (h.) Power supply Running consumption Annual energy cons.- cooling mode (500h) - Directive 2002/31/CE Compressor type Refrigerant type Liquid pipe diameter Gas pipe diameter Max. pipe lenght with gas standard charge Max. pipe lenght with gas additional charge Gas additional charge Max. height between units (Outdoor on top) Max. height between units (Indoor on top) Net weight Indoor / Outdoor Net dimension Indoor (H./W./D.) Net dimension Outdoor (H./W./D.) Units kW BTU/h kcal/h ABCDEFG (kW/kW) m3/h l/h n° dB(A) dB(A) V/Ph/Hz kW kWh FC64AL AE64AC Cooling Heating 6,80 23.190 5.850 B 3,02 840-770-670 3,3 3 + Auto / 1 52-49-46 47 230/1/50 2,250 1125 mm(inch") mm(inch") m m gr/m m m Kg mm mm - Rotary R410A 9,52(3/8") 15,88(5/8") 12,5 20 20 15 15 23,5/74 680x900x190 680x900x340 FC64AL AE64ACL Cooling Heating 6,80 23.190 5.850 B 3,02 840-770-670 3,3 3 + Auto / 1 52-49-46 47 230/1/50 2,250 1125 - Rotary R410A 9,52(3/8") 15,88(5/8") 12,5 20 20 15 15 23,5/74 680x900x190 680x900x340 The technical data here indicated are in compliance with the European standard EN14511 - Directive 2002/31/EC Features w w w. a r g o c l i m a . c o m Floor/Ceiling straight cooling and heat pump air conditioner, available in standard and low ambient mode (-10°C) Automatic change-over between cooling and heating modes (FC64AH) Infrared remote control with 4 digital timers to be set on the 24h and week-end management Double temperature sensor (on remote control / on indoor unit) "I Feel" feature, granting the best comfort conditions Dry function Three-speed centrifugal fan by remote control Horizontal flap swinging by remote control Vertical flap by manual control Night set back capability Heating function disabled during defrosting cycle (FC64AH) Anti-mould and anti-bacteria washable filters Auto restart after a power supply black out Electronic protection against over-pressures High efficiency rotary compressor 38 FC64AL AE64AH Cooling Heating 6,80 7,30 23.190 24.900 5.850 6.280 B D 3,02 3,04 840-770-670 3,3 3 + Auto / 1 52-49-46 47 230/1/50 2,250 2,400 1125 - Rotary R410A 9,52(3/8") 15,88(5/8") 12,5 20 20 15 15 23,5/74 680x900x190 680x900x340 FLOOR/CEILING - ON/OFF R410A improve your life FC64 AC3/ACL3/AH3 PRODUCT NAME Indoor unit Outdoor unit Features Cooling/Heating capacity Energy label class E.E.R. / C.O.P. Air flowrate Indoor (h.m.l.) Dehumidification Fan speeds (Indoor / Outdoor) Sound pressure Indoor (h.m.l.) Sound pressure Outdoor (h.) Power supply Running consumption Annual energy cons.- cooling mode (500h) - Directive 2002/31/CE Compressor type Refrigerant type Liquid pipe diameter Gas pipe diameter Max. pipe lenght with gas standard charge Max. pipe lenght with gas additional charge Gas additional charge Max. height between units (Outdoor on top) Max. height between units (Indoor on top) Net weight Indoor / Outdoor Net dimension Indoor (H./W./D.) Net dimension Outdoor (H./W./D.) Units kW BTU/h kcal/h ABCDEFG (kW/kW) m3/h l/h n° dB(A) dB(A) V/Ph/Hz kW kWh mm(inch") mm(inch") m m gr/m m m Kg mm mm FC64AL AE64AC3 Cooling Heating 6,80 23.190 5.850 B 3,02 840-770-670 3,3 3 + Auto / 1 52-49-46 47 400/3/50 2,250 1125 - Rotary R410A 9,52(3/8") 15,88(5/8") 12,5 20 20 15 15 23,5/74 680x900x190 680x900x340 FC64AL AE64ACL3 Cooling Heating 6,80 23.190 5.850 B 3,02 840-770-670 3,3 3 + Auto / 1 52-49-46 47 400/3/50 2,250 1125 Rotary R410A 9,52(3/8") 15,88(5/8") 12,5 20 20 15 15 23,5/74 680x900x190 680x900x340 - FC64AL AE64AH3 Cooling Heating 6,80 7,30 23.190 24.900 5.850 6.280 B D 3,02 3,04 840-770-670 3,3 3 + Auto / 1 52-49-46 47 400/3/50 2,250 2,400 1125 - Rotary R410A 9,52(3/8") 15,88(5/8") 12,5 20 20 15 15 23,5/74 680x900x190 680x900x340 The technical data here indicated are in compliance with the European standard EN14511 - Directive 2002/31/EC Features Three phase power supply (400/3N/50) Automatic change-over between cooling and heating modes (FC64AH3) Infrared remote control with 4 digital timers to be set on the 24h and week-end management Double temperature sensor (on remote control / on indoor unit) "I Feel" feature, granting the best comfort conditions Dry function Three-speed centrifugal fan by remote control Horizontal flap swinging by remote control Vertical flap by manual control Night set back capability Heating function disabled during defrosting cycle (FC64AH3) Anti-mould and anti-bacteria washable filters Auto restart after a power supply black out Electronic protection against over-pressures w w w. a r g o c l i m a . c o m Floor/Ceiling straight cooling and heat pump air conditioner, available in standard and low ambient mode (-10°C) High efficiency rotary compressor 39 DUCTED - ON/OFF R410A improve your life AD28 AC/ACL/AH PRODUCT NAME Indoor unit Outdoor unit Features Cooling/Heating capacity Energy label class E.E.R. / C.O.P. Air flowrate (h.m.l.) Dehumidification External static pressure (min-max) Fan speeds (Indoor / Outdoor) Sound power Indoor (h.m.l.) Sound pressure Indoor (h.m.l.) at discharge plenum connection Sound pressure Indoor at ducts exit Sound pressure Outdoor (h.) Power supply Running consumption Annual energy cons.- cooling mode (500h) - Directive 2002/31/CE Compressor type Refrigerant type Liquid pipe diameter Gas pipe diameter Max. pipe lenght with gas standard charge Max. pipe lenght with gas additional charge Gas additional charge Max. height between units (Outdoor on top) Max. height between units (Indoor on top) Duct diameter of the 2-way discharge plenum (optional) Net weight Indoor / Indoor with plenum / Outdoor Net dimension Indoor (H./W./D.) Net dimension Indoor with plenum (H./W./D.) Net dimension Outdoor (H./W./D.) Units kW BTU/h kcal/h ABCDEFG (kW/kW) m3/h l/h mm W.G. n° dB(A) dB(A) dB(A) dB(A) V/Ph/Hz kW kWh mm(inch") mm(inch") m m gr/m m m mm Kg mm mm mm AD28AL AE28AC Cooling Heating 2,68 9.140 2.300 B 3,05 600-510-440 0,8 5-7 3 + Auto / 1 54-52-49 45-43-40 < 20 38 230/1/50 0,880 440 Rotary R410A 6,35(1/4") 9,52(3/8") 7,5 15 10 7 7 200 30/36/35 266x926x571 266x926x771 610x795x290 AD28AL AE28ACL Cooling Heating 2,68 9.140 2.300 B 3,05 600-510-440 0,8 5-7 3 + Auto / 1 54-52-49 45-43-40 < 20 38 230/1/50 0,880 440 Rotary R410A 6,35(1/4") 9,52(3/8") 7,5 15 10 7 7 200 30/36/35 266x926x571 266x926x771 610x795x290 AD28AL AE28AH Cooling Heating 2,68 3,35 9.140 11.420 2.300 2.880 B A 3,05 3,76 600-510-440 0,8 5-7 3 + Auto / 1 54-52-49 45-43-40 < 20 40 230/1/50 0,880 0,890 440 Rotary R410A 6,35(1/4") 9,52(3/8") 7,5 15 10 7 7 200 30/36/35 266x926x571 266x926x771 610x795x290 The technical data here indicated are in compliance with the European standard EN14511 - Directive 2002/31/EC Features w w w. a r g o c l i m a . c o m Ducted straight cooling and heat pump air conditioner with optional discharge Plenum Available in standard and low ambient mode (-10°C) Automatic change-over between cooling and heating modes (AD28AH) Special wireless infrared receiver and infrared remote control with 4 digital timers to be set on the 24h and week-end management Double temperature sensor (on remote control / on indoor unit) "I Feel" feature, granting the best comfort conditions Dry function Three-speed centrifugal fan by remote control and feature to increase speed/pressure (from 5 to 7 mm c.a.) Night set back capability Heating function disabled during defrosting cycle (AD28AH) Anti-mould and anti-bacteria washable filters Integrated pump for condensate discharge Auto restart after a power supply black out Electronic protection against over-pressures Two-way duct discharge plenum (optional) High efficiency rotary compressor 40 DUCTED - ON/OFF R410A improve your life AD28 AC/ACL/AH PRODUCT NAME Indoor unit Outdoor unit Features Cooling/Heating capacity Energy label class E.E.R. / C.O.P. Air flowrate (h.m.l.) Dehumidification External static pressure (min-max) Fan speeds (Indoor / Outdoor) Sound power Indoor (h.m.l.) Sound pressure Indoor (h.m.l.) at discharge plenum connection Sound pressure Indoor at ducts exit Sound pressure Outdoor (h.) Power supply Running consumption Annual energy cons.- cooling mode (500h) - Directive 2002/31/CE Compressor type Refrigerant type Liquid pipe diameter Gas pipe diameter Max. pipe lenght with gas standard charge Max. pipe lenght with gas additional charge Gas additional charge Max. height between units (Outdoor on top) Max. height between units (Indoor on top) Duct diameter of the 2-way discharge plenum (optional) Net weight Indoor / Indoor with plenum / Outdoor Net dimension Indoor (H./W./D.) Net dimension Indoor with plenum (H./W./D.) Net dimension Outdoor (H./W./D.) Units kW BTU/h kcal/h ABCDEFG (kW/kW) m3/h l/h mm W.G. n° dB(A) dB(A) dB(A) dB(A) V/Ph/Hz kW kWh mm(inch") mm(inch") m m gr/m m m mm Kg mm mm mm AD28AL AE28AC Cooling Heating 2,68 9.140 2.300 B 3,05 600-510-440 0,8 5-7 3 + Auto / 1 54-52-49 45-43-40 < 20 38 230/1/50 0,880 440 Rotary R410A 6,35(1/4") 9,52(3/8") 7,5 15 10 7 7 200 30/36/35 266x926x571 266x926x771 610x795x290 AD28AL AE28ACL Cooling Heating 2,68 9.140 2.300 B 3,05 600-510-440 0,8 5-7 3 + Auto / 1 54-52-49 45-43-40 < 20 38 230/1/50 0,880 440 Rotary R410A 6,35(1/4") 9,52(3/8") 7,5 15 10 7 7 200 30/36/35 266x926x571 266x926x771 610x795x290 AD28AL AE28AH Cooling Heating 2,68 3,35 9.140 11.420 2.300 2.880 B A 3,05 3,76 600-510-440 0,8 5-7 3 + Auto / 1 54-52-49 45-43-40 < 20 40 230/1/50 0,880 0,890 440 Rotary R410A 6,35(1/4") 9,52(3/8") 7,5 15 10 7 7 200 30/36/35 266x926x571 266x926x771 610x795x290 The technical data here indicated are in compliance with the European standard EN14511 - Directive 2002/31/EC Features w w w. a r g o c l i m a . c o m Ducted straight cooling and heat pump air conditioner with optional discharge Plenum Available in standard and low ambient mode (-10°C) Automatic change-over between cooling and heating modes (AD28AH) Special wireless infrared receiver and infrared remote control with 4 digital timers to be set on the 24h and week-end management Double temperature sensor (on remote control / on indoor unit) "I Feel" feature, granting the best comfort conditions Dry function Three-speed centrifugal fan by remote control and feature to increase speed/pressure (from 5 to 7 mm c.a.) Night set back capability Heating function disabled during defrosting cycle (AD28AH) Anti-mould and anti-bacteria washable filters Integrated pump for condensate discharge Auto restart after a power supply black out Electronic protection against over-pressures Two-way duct discharge plenum (optional) High efficiency rotary compressor 40 DUCTED - ON/OFF R410A improve your life AD52 AC/ACL/AH PRODUCT NAME Indoor unit Outdoor unit Features Cooling/Heating capacity Energy label class E.E.R. / C.O.P. Air flowrate (h.m.l.) Dehumidification External static pressure (min-max) Fan speeds (Indoor / Outdoor) Sound power Indoor (h.m.l.) Sound pressure Indoor (h.m.l.) at discharge plenum co Sound pressure Indoor at ducts exit Sound pressure Outdoor (h.) Power supply Running consumption Annual energy cons.- cooling mode (500h) - Directive 2002/31/CE Compressor type Refrigerant type Liquid pipe diameter Gas pipe diameter Max. pipe lenght with gas standard charge Max. pipe lenght with gas additional charge Gas additional charge Max. height between units (Outdoor on top) Max. height between units (Indoor on top) Duct diameter of the 3-way discharge plenum (optiona Net weight Indoor / Indoor with plenum / Outdoor Net dimension Indoor (H./W./D.) Net dimension Indoor with plenum (H./W./D.) Net dimension Outdoor (H./W./D.) Units kW BTU/h kcal/h ABCDEFG (kW/kW) m3/h l/h mm W.G. n° dB(A) dB(A) dB(A) dB(A) V/Ph/Hz kW kWh mm(inch") mm(inch") m m gr/m m m mm Kg mm mm mm AD52AL AE52AC Cooling Heating 5,80 19.780 4.990 A 3,22 875-600-400 2,3 5-7 3 + Auto / 1 54-47-42 45-38-33 < 20 48 230/1/50 1,800 900 - Rotary R410A 6,35(1/4") 12,7(1/2") 10 25 20 15 15 200 35/42,5/56 266x1132x571 266x1132x771 690x846x302 AD52AL AE52ACL Cooling Heating 5,80 19.780 4.990 A 3,22 875-600-400 2,3 5-7 3 + Auto / 1 54-47-42 45-38-33 < 20 48 230/1/50 1,800 900 - Rotary R410A 6,35(1/4") 12,7(1/2") 10 25 20 15 15 200 35/42,5/56 266x1132x571 266x1132x771 690x846x302 AD52AL AE52AH Cooling Heating 5,80 6,25 19.780 21.310 4.990 5.375 A B 3,22 3,42 875-600-400 2,3 5-7 3 + Auto / 1 54-47-42 45-38-33 < 20 48 230/1/50 1,800 1,830 900 The technical data here indicated are in compliance with the European standard EN14511 - Directive 2002/31/EC Features w w w. a r g o c l i m a . c o m Ducted straight cooling and heat pump air conditioner with optional discharge Plenum Available in standard and low ambient mode (-10°C) Automatic change-over between cooling and heating modes (AD52AH) Special wireless infrared receiver and infrared remote control with 4 digital timers to be set on the 24h and week-end management Double temperature sensor (on remote control / on indoor unit) "I Feel" feature, granting the best comfort conditions Dry function Three-speed centrifugal fan by remote control and feature to increase speed/pressure (from 5 to 7 mm c.a.) Night set back capability Heating function disabled during defrosting cycle (AD52AH) Anti-mould and anti-bacteria washable filters Integrated pump for condensate discharge Auto restart after a power supply black out Electronic protection against over-pressures Three-way duct discharge plenum (optional) High efficiency rotary compressor 42 - Rotary R410A 6,35(1/4") 12,7(1/2") 10 25 20 15 15 200 35/42,5/56 266x1132x571 266x1132x771 690x846x302 DUCTED - ON/OFF R410A improve your life AD52 AC3/ACL3/AH3 PRODUCT NAME Indoor unit Outdoor unit Features Cooling/Heating capacity Energy label class E.E.R. / C.O.P. Air flowrate (h.m.l.) Dehumidification External static pressure (min-max) Fan speeds (Indoor / Outdoor) Sound power Indoor (h.m.l.) Sound pressure Indoor (h.m.l.) at discharge plenum co Sound pressure Indoor at ducts exit Sound pressure Outdoor (h.) Power supply Running consumption Annual energy cons.- cooling mode (500h) - Directive 2002/31/CE Compressor type Refrigerant type Liquid pipe diameter Gas pipe diameter Max. pipe lenght with gas standard charge Max. pipe lenght with gas additional charge Gas additional charge Max. height between units (Outdoor on top) Max. height between units (Indoor on top) Duct diameter of the 3-way discharge plenum (optiona Net weight Indoor / Indoor with plenum / Outdoor Net dimension Indoor (H./W./D.) Net dimension Indoor with plenum (H./W./D.) Net dimension Outdoor (H./W./D.) Units kW BTU/h kcal/h ABCDEFG (kW/kW) m3/h l/h mm W.G. n° dB(A) dB(A) dB(A) dB(A) V/Ph/Hz kW kWh mm(inch") mm(inch") m m gr/m m m mm Kg mm mm mm AD52AL AE52AC3 Cooling Heating 5,80 19.780 4.990 A 3,22 875-600-400 2,3 5-7 3 + Auto / 1 54-47-42 45-38-33 < 20 48 400/3/50 1,800 900 Rotary R410A 6,35(1/4") 12,7(1/2") 10 25 20 15 15 200 35/42,5/56 266x1132x571 266x1132x771 690x846x302 - AD52AL AE52ACL3 Cooling Heating 5,80 19.780 4.990 A 3,22 875-600-400 2,3 5-7 3 + Auto / 1 54-47-42 45-38-33 < 20 48 400/3/50 1,800 900 - AD52AL AE52AH3 Cooling Heating 5,80 6,25 19.780 21.310 4.990 5.375 A B 3,22 3,42 875-600-400 2,3 5-7 3 + Auto / 1 54-47-42 45-38-33 < 20 47 400/3/50 1,800 1,830 900 Rotary R410A 6,35(1/4") 12,7(1/2") 10 25 20 15 15 200 35/42,5/56 266x1132x571 266x1132x771 690x846x302 - Rotary R410A 6,35(1/4") 12,7(1/2") 10 25 20 15 15 200 35/42,5/56 266x1132x571 266x1132x771 690x846x302 The technical data here indicated are in compliance with the European standard EN14511 - Directive 2002/31/EC Features Available in standard and low ambient mode (-10°C) Three phase power supply (400/3N/50) Automatic change-over between cooling and heating modes (AD52AH3) Special wireless infrared receiver and infrared remote control with 4 digital timers to be set on the 24h and week-end management Double temperature sensor (on remote control / on indoor unit) "I Feel" feature, granting the best comfort conditions Dry function Three-speed centrifugal fan by remote control and feature to increase speed/pressure (from 5 to 7 mm c.a.) Night set back capability Heating function disabled during defrosting cycle (AD52AH3) Anti-mould and anti-bacteria washable filters Integrated pump for condensate discharge Auto restart after a power supply black out Electronic protection against over-pressures Three-way duct discharge plenum (optional) w w w. a r g o c l i m a . c o m Ducted straight cooling and heat pump air conditioner with optional discharge Plenum High efficiency rotary compressor 43 DUCTED - ON/OFF R410A improve your life AD64 AC/ACL/AH PRODUCT NAME Indoor unit Outdoor unit Features Cooling/Heating capacity Energy label class E.E.R. / C.O.P. Air flowrate (h.m.l.) Dehumidification External static pressure (min-max) Fan speeds (Indoor / Outdoor) Sound power Indoor (h.m.l.) Sound pressure Indoor (h.m.l.) at discharge plenum connection Sound pressure Indoor at ducts exit Sound pressure Outdoor (h.) Power supply Running consumption Annual energy cons.- cooling mode (500h) - Directive 2002/31/CE Compressor type Refrigerant type Liquid pipe diameter Gas pipe diameter Max. pipe lenght with gas standard charge Max. pipe lenght with gas additional charge Gas additional charge Max. height between units (Outdoor on top) Max. height between units (Indoor on top) Duct diameter of the 3-way discharge plenum(optional) Net weight Indoor / Indoor with plenum / Outdoor Net dimension Indoor (H./W./D.) Net dimension Indoor with plenum (H./W./D.) Net dimension Outdoor (H./W./D.) Units kW BTU/h kcal/h ABCDEFG (kW/kW) m3/h l/h mm W.G. n° dB(A) AD64AL AE64AC Cooling Heating 7,00 23.870 6.020 C 2,98 1000-700-600 2,6 5-7 3 + Auto / 1 57-49-46 AD64AL AE64ACL Cooling Heating 7,00 23.870 6.020 C 2,98 1000-700-600 2,6 5-7 3 + Auto / 1 57-49-46 AD64AL AE64AH Cooling Heating 7,00 7,55 23.870 25.750 6.020 6.495 C D 2,98 3,02 1000-700-600 2,6 5-7 3 + Auto / 1 57-49-46 dB(A) 48-40-37 48-40-37 48-40-37 dB(A) dB(A) V/Ph/Hz kW kWh < 20 47 230/1/50 2,350 - < 20 47 230/1/50 2,350 - < 20 47 230/1/50 2,350 2,500 1175 1175 1175 mm(inch") mm(inch") m m gr/m m m mm Kg mm mm mm - Rotary R410A 9,52(3/8") 15,88(5/8") 12,5 20 20 15 15 200 35/42,5/74 266x1132x571 266x1132x771 680x900x340 - Rotary R410A 9,52(3/8") 15,88(5/8") 12,5 20 20 15 15 200 35/42,5/74 266x1132x571 266x1132x771 680x900x340 The technical data here indicated are in compliance with the European standard EN14511 - Directive 2002/31/EC Features w w w. a r g o c l i m a . c o m Ducted straight cooling and heat pump air conditioner with optional discharge Plenum Available in standard and low ambient mode (-10°C) Automatic change-over between cooling and heating modes (AD64AH) Special wireless infrared receiver and infrared remote control with 4 digital timers to be set on the 24h and week-end management Double temperature sensor (on remote control / on indoor unit) "I Feel" feature, granting the best comfort conditions Dry function Three-speed centrifugal fan by remote control and feature to increase speed/pressure (from 5 to 7 mm c.a.) Night set back capability Heating function disabled during defrosting cycle (AD64AH) Anti-mould and anti-bacteria washable filters Integrated pump for condensate discharge Auto restart after a power supply black out Electronic protection against over-pressures Three-way duct discharge plenum (optional) High efficiency rotary compressor 44 - Rotary R410A 9,52(3/8") 15,88(5/8") 12,5 20 20 15 15 200 35/42,5/74 266x1132x571 266x1132x771 680x900x340 DUCTED - ON/OFF R410A improve your life AD64 AC3/ACL3/AH3 PRODUCT NAME Indoor unit Outdoor unit Features Cooling/Heating capacity Energy label class E.E.R. / C.O.P. Air flowrate (h.m.l.) Dehumidification External static pressure (min-max) Fan speeds (Indoor / Outdoor) Sound power Indoor (h.m.l.) Sound pressure Indoor(h.m.l.)at discharge plenum connection Sound pressure Indoor at ducts exit Sound pressure Outdoor (h.) Power supply Running consumption Annual energy cons.- cooling mode (500h) - Directive 2002/31/CE Compressor type Refrigerant type Liquid pipe diameter Gas pipe diameter Max. pipe lenght with gas standard charge Max. pipe lenght with gas additional charge Gas additional charge Max. height between units (Outdoor on top) Max. height between units (Indoor on top) Duct diameter of the 3-way discharge plenum(optional) Net weight Indoor / Indoor with plenum / Outdoor Net dimension Indoor (H./W./D.) Net dimension Indoor with plenum (H./W./D.) Net dimension Outdoor (H./W./D.) Units kW BTU/h kcal/h ABCDEFG (kW/kW) m3/h l/h mm W.G. n° dB(A) AD64AL AE64AC3 Cooling Heating 7,00 23.870 6.020 C 2,98 1000-700-600 2,6 5-7 3 + Auto / 1 57-49-46 AD64AL AE64ACL3 Cooling Heating 7,00 23.870 6.020 C 2,98 1000-700-600 2,6 5-7 3 + Auto / 1 57-49-46 AD64AL AE64AH3 Cooling Heating 7,00 7,55 23.870 25.750 6.020 6.495 C D 2,98 3,02 1000-700-600 2,6 5-7 3 + Auto / 1 57-49-46 dB(A) 48-40-37 48-40-37 48-40-37 dB(A) dB(A) V/Ph/Hz kW kWh mm(inch") mm(inch") m m gr/m m m mm Kg mm mm mm < 20 47 400/3/50 2,350 - < 20 47 400/3/50 2,350 - < 20 47 400/3/50 2,350 2,500 1175 1175 1175 - Rotary R410A 9,52(3/8") 15,88(5/8") 12,5 20 20 15 15 200 35/42,5/74 266x1132x571 266x1132x771 680x900x340 - Rotary R410A 9,52(3/8") 15,88(5/8") 12,5 20 20 15 15 200 35/42,5/74 266x1132x571 266x1132x771 680x900x340 - Rotary R410A 9,52(3/8") 15,88(5/8") 12,5 20 20 15 15 200 35/42,5/74 266x1132x571 266x1132x771 680x900x340 The technical data here indicated are in compliance with the European standard EN14511 - Directive 2002/31/EC Features Available in standard and low ambient mode (-10°C) Three phase power supply (400/3N/50) Automatic change-over between cooling and heating modes (AD64AH3) Special wireless infrared receiver and infrared remote control with 4 digital timers to be set on the 24h and week-end management Double temperature sensor (on remote control / on indoor unit) "I Feel" feature, granting the best comfort conditions Dry function Three-speed centrifugal fan by remote control and feature to increase speed/pressure (from 5 to 7 mm c.a.) Night set back capability Heating function disabled during defrosting cycle (AD64AH3) Anti-mould and anti-bacteria washable filters Integrated pump for condensate discharge Auto restart after a power supply black out Electronic protection against over-pressures Three-way duct discharge plenum (optional) w w w. a r g o c l i m a . c o m Ducted straight cooling and heat pump air conditioner with optional discharge Plenum High efficiency rotary compressor 45 w w w. a r g o c l i m a . c o m SPLIT DC INVERTER R410A improve your life SPLIT DC INVERTER R410A improve your life AWI25 PRODUCT NAME Indoor unit Outdoor unit Features Cooling/Heating capacity - nominal (min-max) Energy label class E.E.R. / C.O.P. Air flowrate Indoor (h.m.l.) Dehumidification Fan speeds (Indoor / Outdoor) Sound pressure Indoor (h.m.l.) Sound pressure Outdoor (h.) Power supply Running consumption - nominal (min-max) Annual energy cons.- cooling mode (500h) - Directive 2002/31/CE Compressor type Refrigerant type Liquid pipe diameter Gas pipe diameter Max. pipe lenght with gas standard charge Max. pipe lenght with gas additional charge Gas additional charge Max. height between units (Outdoor on top) Max. height between units (Indoor on top) Net weight Indoor / Outdoor Net dimension Indoor (H./W./D.) Net dimension Outdoor (H./W./D.) AWI25AHL AWI25AHL AEI25AH Units kW BTU/h kcal/h ABCDEFG (kW/kW) m3/h l/h n° dB(A) dB(A) V/Ph/Hz kW kWh mm(inch") mm(inch") m m gr/m m m Kg mm mm Cooling Heating 2,65(0,90-3,20) 3,60(0,90-5,00) 9.100 12.300 2.280 3.100 A A 3,51 3,62 530-480-450 1,6 3 + Auto/ 2 (Auto) 34-31-28 47 230/1/50 0,755 (0,250-1,150) 0,995(0,250-1,340) 378 Rotary R410A 6,35(1/4") 9,52(3/8") 7,5 10 15 7 7 10/29 285x825x189 548x720x265 The technical data here indicated are in compliance with the European standard EN14511 - Directive 2002/31/EC Features NEWS 20 Matching with cassette, ducted & floor i.u. available by 2° S. 2006 06! Straight cooling and heat pump air conditioner Automatic change-over between cooling and heating modes Infrared remote control with 24h digital timer Double temperature sensor (on remote control / on indoor unit) "I Feel" feature, granting the best comfort conditions Dry function Three-speed tangential fan by remote control Night set back capability Heating function disabled during defrosting cycle Horizontal flap swinging or to be set on a fixed position by remote control Vertical flap by manual control Anti-mould and anti-bacteria washable filters; active carbon filters Natural Ionizer Tape with negative ions emission Auto restart after a power supply black out Electronic protection against over-pressures w w w. a r g o c l i m a . c o m DC Inverter technology - R410A Double way (right and left) to discharge the condensate High efficiency rotary compressor 47 SPLIT DC INVERTER R410A improve your life AWI35 PRODUCT NAME Indoor unit Outdoor unit Features Cooling/Heating capacity - nominal (min-max) Energy label class E.E.R. / C.O.P. Air flowrate Indoor (h.m.l.) Dehumidification Fan speeds (Indoor / Outdoor) Sound pressure Indoor (h.m.l.) Sound pressure Outdoor (h.) Power supply Running consumption - nominal (min-max) Annual energy cons.- cooling mode (500h) - Directive 2002/31/CE Compressor type Refrigerant type Liquid pipe diameter Gas pipe diameter Max. pipe lenght with gas standard charge Max. pipe lenght with gas additional charge Gas additional charge Max. height between units (Outdoor on top) Max. height between units (Indoor on top) Net weight Indoor / Outdoor Net dimension Indoor (H./W./D.) Net dimension Outdoor (H./W./D.) AWI35AHL AWI35AHL AEI35AH Units kW BTU/h kcal/h ABCDEFG (kW/kW) m3/h l/h n° dB(A) dB(A) V/Ph/Hz kW kWh mm(inch") mm(inch") m m gr/m m m Kg mm mm Cooling Heating 3,50(0,90-3,80) 4,20(0,90-5,80) 11.900 14.300 3.010 3.610 A A 3,21 3,61 540-490-460 2,0 3 + Auto/ 2 (Auto) 36-33-29 49 230/1/50 1,090(0,250-1,300) 1,165(0,250-1,500) 545 Rotary R410A 6,35(1/4") 9,52(3/8") 7,5 15 15 7 7 10/30 285x825x189 548x720x265 The technical data here indicated are in compliance with the European standard EN14511 - Directive 2002/31/EC Features Straight cooling and heat pump air conditioner DC Inverter technology - R410A w w w. a r g o c l i m a . c o m Automatic change-over between cooling and heating modes Infrared remote control with 24h digital timer Double temperature sensor (on remote control / on indoor unit) "I Feel" feature, granting the best comfort conditions Dry function Three-speed tangential fan by remote control Night set back capability Heating function disabled during defrosting cycle Horizontal flap swinging or to be set on a fixed position by remote control Vertical flap by manual control Anti-mould and anti-bacteria washable filters; active carbon filters Natural Ionizer Tape with negative ions emission Auto restart after a power supply black out Electronic protection against over-pressures Double way (right and left) to discharge the condensate High efficiency rotary compressor 48 NEWS 20 Matching with cassette, ducted & floor/ceiling i.u. available by 2° S. 2006 06! SPLIT DC INVERTER R410A improve your life AWI55 PRODUCT NAME Indoor unit Outdoor unit Features Cooling/Heating capacity - nominal (min-max) Energy label class E.E.R. / C.O.P. Air flowrate Indoor (h.m.l.) Dehumidification Fan speeds (Indoor / Outdoor) Sound pressure Indoor (h.m.l.) Sound pressure Outdoor (h.) Power supply Running consumption - nominal (min-max) Annual energy cons.- cooling mode (500h) - Dir. 2002/31/CE Compressor type Refrigerant type Liquid pipe diameter Gas pipe diameter Max. pipe lenght with gas standard charge Max. pipe lenght with gas additional charge Gas additional charge Max. height between units (Outdoor on top) Max. height between units (Indoor on top) Net weight Indoor / Outdoor Net dimension Indoor (H./W./D.) Net dimension Outdoor (H./W./D.) AWI55AHL AWI55AHL AEI55AH Units kW BTU/h kcal/h ABCDEFG (kW/kW) m3/h l/h n° dB(A) dB(A) V/Ph/Hz kW kWh mm(inch") mm(inch") m m gr/m m m Kg mm mm Cooling 5,15 (1,2-5,5) 17.560 4.430 A 3,43 890 Heating 6,00 (1,3-6,4) 20.460 5.160 A 3,81 920 2,30 3 + Auto/ 1 (Alta) 42-35-28 52 230/1/50 1,5 (0,25-1,8) 1,575 (0,27-1,93) 2.575 Rotary (DC Inverter) R410A 6,35(1/4") 12,7(1/2") 10 30 25 15 15 12/44 298x1065x233 670x880x285 The technical data here indicated are in compliance with the European standard EN14511 - Directive 2002/31/EC Features NEWS 2006 Matching with hi-w wall i.u. ! available by the 2° Q. 2006 Matching (single-pphase) with cassette, ducted & Straight cooling and heat pump air conditioner floor/ceiling i.u. available by 2° S. 2006 DC Inverter technology - R410A Infrared remote control with 24h digital timer Double temperature sensor (on the unit and inside the remote control) "I Feel" feature, granting the best comfort conditions Dry function Three-speed tangential fan by remote control Night set back capability Heating function disabled during defrosting cycle Horizontal flap swinging or to be set to a fixed position by remote control Vertical flap by manual control Anti-mould and anti-bacteria washable filters; active carbon filters Natural Ionizer Tape with negative ions emission Auto restart after a power supply black out Electronic protection against over-pressures w w w. a r g o c l i m a . c o m Automatic change-over between cooling and heating modes Double way (right and left) to discharge the condensate High efficiency rotary compressor 49 DC INVERTER-MONO R410A improve your life AWI70 PRODUCT NAME Indoor unit Outdoor unit Features Cooling/Heating capacity - nominal (min-max) Energy label class E.E.R. / C.O.P. Air flowrate Indoor (h.m.l.) Dehumidification Fan speeds (Indoor / Outdoor) Sound pressure Indoor (h.m.l.) Sound pressure Outdoor (h.) Power supply Running consumption - nominal (min-max) Annual energy cons.- cooling mode (500h) - Dir. 2002/31/CE Compressor type Refrigerant type Liquid pipe diameter Gas pipe diameter Max. pipe lenght with gas standard charge Max. pipe lenght with gas additional charge Gas additional charge Max. height between units (Outdoor on top) Max. height between units (Indoor on top) Net weight Indoor / Outdoor Net dimension Indoor (H./W./D.) Net dimension Outdoor (H./W./D.) AWI70AHL AWI70AHL AEI70AH Units kW BTU/h kcal/h ABCDEFG (kW/kW) m3/h l/h n° dB(A) dB(A) V/Ph/Hz kW kWh mm(inch") mm(inch") m m gr/m m m Kg mm mm Cooling 7,10 (1,2-8,0) 24.210 6.110 B 3,01 1020 3,3 3 + Auto/ 1 (High) 45-38-30 55 230/1/50 2,355 (0,28-2,845) 2,49 (0,29-3,15) 1.178 Rotary (DC Inverter) R410A 6,35(1/4") 15,88(5/8") 10 30 25 15 15 12/59 298x1065x233 670x880x285 The technical data here indicated are in compliance with the European standard EN14511 - Directive 2002/31/EC Features Heating 8,50 (1,3-9,5) 28.990 7.310 B 3,41 920 NEWS 2006 Matching with hi-w wall i.u. ! available by the 2° Q. 2006 Matching (single-pphase) with ducted & floor/ceiling i.u. Straight cooling and heat pump air conditioner DC Inverter technology - R410A w w w. a r g o c l i m a . c o m Automatic change-over between cooling and heating modes Infrared remote control with 24h digital timer Double temperature sensor (on the unit and inside the remote control) "I Feel" feature, granting the best comfort conditions Dry function Three-speed tangential fan by remote control Night set back capability Heating function disabled during defrosting cycle Horizontal flap swinging or to be set to a fixed position by remote control Vertical flap by manual control Anti-mould and anti-bacteria washable filters; active carbon filters Natural Ionizer Tape with negative ions emission Auto restart after a power supply black out Electronic protection against over-pressures Double way (right and left) to discharge the condensate High efficiency rotary compressor 50 available by 2° S. 2006 M U LT I S P L I T D C I N V E R T E R R 4 1 0 A w w w. a r g o c l i m a . c o m improve your life improve your life DUAL TRIAL AE2MI56 AE3MI70 QUADRI AE4MI91 Cooling: 5,6 kW Heating: 7,3 kW Cooling: 6,8 kW Heating: 8,6 kW Cooling: 9 kW Heating: 10 kW TECHNICAL DATA w w w. a r g o c l i m a . c o m PRODUCT NAME Outdoor unit Features Connectable indoor units Minimum number of connected indoor units Cooling/Heating capacity - nominal (min-max) Energy label class E.E.R. / C.O.P. Air flowrate Outdoor (h.) Fan speeds Outdoor Sound pressure Outdoor (h.) Power supply Running consumption Annual energy cons.- cooling mode (500h) - Directive 2002/31/CE Compressor type Refrigerant type Liquid pipe diameter Gas pipe diameter Max. pipe lenght (per indoor unit) Max. total pipe lenght Gas additional charge Max. height between units (Outdoor on top) Max. height between units (Indoor on top) Net weight Outdoor Net dimension Outdoor (H./W./D.) AE2MI56AH Units n° n° kW BTU/h kcal/h ABCDEFG (kW/kW) m³/h n° dB(A) V/Ph/Hz kW kWh mm(inch") mm(inch") m m gr/m m m Kg mm Cooling 2 2 AE3MI70AH Heating 5,60 7,30 (1,40-6,50) (1,70-8,40) 19.100 24.900 4.820 6.280 B B 3,13 3,46 2.400 2 (Auto) 48 49 230/1/50 1,790 2,110 895 - Twin Rotary (DC inverter) R410A 6,35(1/4") x 2 9,52(3/8") x 2 25 35 not required 10 10 69 730x940x340 Cooling 3 2 6,80 8,60 (1,40-8,10) (1,70-9,00) 23.200 29.300 5.850 7.400 A A 3,33 3,81 2.400 2 (Auto) 48 49 230/1/50 2,040 2,260 1.020 6 - Twin Rotary (DC inverter) R410A 6,35(1/4") x 3 9,52(3/8") x 3 25 50 not required 10 10 70 730x940x340 The technical data here indicated are in compliance with the European standard EN14511 - Directive 2002/31/EC 52 AE4MI91AH Heating Cooling 4 2 Heating 9,00 10,00 (1,20-10,50) (1,70-10,80) 30.700 34.100 7.740 8.600 A A 4,64 4,61 2.800 2 (Auto) 53 54 230/1/50 1,940 2,170 970 - Twin Rotary (DC inverter) R410A 6,35(1/4") x 4 9,52(3/8")x3 - 12,7(1/2")x1 30 70 not required 10 10 90 880x940x340 M U LT I S P L I T D C I N V E R T E R R 4 1 0 A Indoor unit capacity 2,8 kW improve your life Indoor unit capacity 3,6 kW / 5 kW Features Multisplit cooling and heat pump air conditioner for cooling, dehumidification and heating modes Indoor unit capacity 7 kW DC Inverter technology - R410A Two refrigerant valves (ae2mi56ah), three refrigerant valves (ae3mi70ah), four refrigerant valves (ae4mi91ah) controlled by an electronic microprocessor system Fully mixed matching possibility of the indoor units (high-wall, cassette, Cassette indoor units ducted, floor and floor/ceiling): for more information on the indoor units and their possible matchings see the following pages With a proper connection of the cassette or ducted indoor units it is possible to manage up to two groups of two rooms each or one single room with four air sendout points (ae2mi56ah);two groups of three rooms each or one single room with six air sendout points (ae3mi70ah); two groups of four rooms each or one single room with eight air sendout points (ae4mi91ah) Ducted indoor units In case more indoor units are installed in the same room, it is possible to address each remote control to its own indoor unit only, so that to avoid any interference It works with at least two indoor units connected Single-phase power supply 230/1/50 Floor/Ceiling indoor units Auto restart after a power supply black out Electronic protection against over-pressures Double rotary DC inverter compressor Plug kit for condensate drain holes (on outdoor unit base) optional w w w. a r g o c l i m a . c o m Each indoor unit is managed by its own remote control Floor indoor units 53 M U LT I S P L I T D C I N V E R T E R R 4 1 0 A improve your life INDOOR UNITS MATCHING TABLE AE2MI56AH OUTDOOR UNIT MODEL Performance 1 unit Connectable Indoor units 2 units 28 36 50 28+28 28+36 28+50 36+36 36+50 OUTDOOR UNIT MODEL Performance 1 unit Connectable Indoor units 2 units 3 units 28 36 50 28+28 28+36 28+50 36+36 36+50 28+28+28 28+28+36 28+28+50 28+36+36 28+36+50 36+36+36 OUTDOOR UNIT MODEL Performance w w w. a r g o c l i m a . c o m 1 unit 54 2 units Connectable Indoor units 3 units 4 units 28 36 50 70 28+28 28+36 36+36 28+50 36+50 28+70 28+28+28 28+28+36 28+28+50 28+28+70 28+36+36 28+36+50 36+36+36 36+36+50 28+28+28+28 28+28+28+36 28+28+28+50 28+28+28+70 28+28+36+36 28+28+36+50 28+36+36+36 28+36+36+50 36+36+36+36 Cooling Indoor capacity (kW) A B C D 2,80 3,60 5,00 2,80 2,80 2,45 3,15 2,00 3,60 2,80 2,80 2,35 3,25 - Total capacity kW 2,80 3,60 5,00 5,60 5,60 5,60 5,60 5,60 Heating Indoor capacity (kW) A B C D 4,00 4,80 7,10 3,65 3,65 3,30 4,00 2,65 4,65 3,65 3,65 2,95 4,35 - Total capacity kW 4,00 4,80 7,10 7,30 7,30 7,30 7,30 7,30 AE3MI70AH Cooling Indoor capacity (kW) A B C D 2,80 3,60 5,00 2,80 2,80 2,80 3,60 2,45 4,35 3,40 3,40 2,85 3,95 2,26 2,26 2,26 2,07 2,07 2,65 1,80 1,80 3,20 1,90 2,45 2,45 1,65 2,15 3,00 2,26 2,26 2,26 - Total capacity kW 2,80 3,60 5,00 5,60 6,40 6,80 6,80 6,80 6,80 6,80 6,80 6,80 6,80 6,80 Heating Indoor capacity (kW) A B C D 4,00 4,80 7,10 4,00 4,00 3,90 4,70 3,10 5,50 4,30 4,30 3,45 5,15 2,86 2,86 2,86 2,70 2,70 3,20 2,30 2,30 4,00 2,50 3,05 3,05 2,15 2,60 3,85 2,86 2,86 2,86 - Total capacity kW 4,00 4,80 7,10 8,00 8,60 8,60 8,60 8,60 8,60 8,60 8,60 8,60 8,60 8,60 AE4MI91AH Cooling Indoor capacity (kW) A B C D 2,80 3,60 5,00 7,00 2,80 2,80 2,80 3,60 3,60 3,60 2,80 5,00 3,60 5,00 2,55 6,45 2,80 2,80 2,80 2,75 2,75 3,50 2,40 2,40 4,20 2,00 2,00 5,00 2,50 3,25 3,25 2,20 2,85 3,95 3,00 3,00 3,00 2,65 2,65 3,70 2,25 2,25 2,25 2,25 2,10 2,10 2,10 2,70 1,90 1,90 1,90 3,30 1,65 1,65 1,65 4,05 2,00 2,00 2,50 2,50 1,75 1,75 2,30 3,20 1,80 2,40 2,40 2,40 1,70 2,15 2,15 3,00 2,25 2,25 2,25 2,25 Total capacity kW 2,80 3,60 5,00 7,00 5,60 6,40 7,20 7,80 8,60 9,00 8,40 9,00 9,00 9,00 9,00 9,00 9,00 9,00 9,00 9,00 9,00 9,00 9,00 9,00 9,00 9,00 9,00 Heating Indoor capacity (kW) A B C D 4,00 4,80 7,10 8,00 4,00 4,00 4,00 4,80 4,80 4,80 3,60 6,40 4,00 6,00 3,35 6,65 3,33 3,33 3,33 3,10 3,10 3,80 2,65 2,65 4,70 2,50 2,50 5,00 2,90 3,55 3,55 2,50 3,00 4,50 3,33 3,33 3,33 2,85 2,85 4,30 2,50 2,50 2,50 2,50 2,40 2,40 2,40 2,80 2,10 2,10 2,10 3,70 2,00 2,00 2,00 4,00 2,25 2,25 2,75 2,75 2,00 2,00 2,40 3,60 2,20 2,60 2,60 2,60 1,95 2,30 2,30 3,45 2,50 2,50 2,50 2,50 Total capacity kW 4,00 4,80 7,10 8,00 8,00 8,80 9,60 10,00 10,00 10,00 10,00 10,00 10,00 10,00 10,00 10,00 10,00 10,00 10,00 10,00 10,00 10,00 10,00 10,00 10,00 10,00 10,00 M U LT I S P L I T D C I N V E R T E R R 4 1 0 A improve your life INDOOR UNITS TABLE Air flowrate (h.m.l.) m3/h 620-510-370 m3/h 580-450-400 m3/h 680-620-530 m3/h 1100-1000-920 AWMI28AHL AWMI36AHL AWMI50AHL AWMI70AHL Hi-wall units Fan speeds Dry l/h 1,6 3 + Auto l/h 2,0 3 + Auto l/h 2,8 3 + Auto l/h 3,4 3 + Auto Sound pressure(h.m.l.) dB(A) 41-38-33 dB(A) 46-39-33 dB(A) 49-44-38 dB(A) 47-43-38 Dimension (HxWxD) mm 275x805x178 mm 285x805x219 mm 285x805x219 mm 330x1.140x228 Net weight kg 8,5 kg 9,5 kg 9,5 kg 18 ASMI28HG ASMI36HG ASMI50HG ASGMI28HG (grille) m3/h 700-600-500 m3/h 700-600-501 m3/h 750-630-530 Cassette l/h 0,5 3 l/h 1,0 3 l/h 2,3 3 units + Auto + Auto + Auto dB(A) 43-39-36 dB(A) 43-39-36 dB(A) 44-39-36 mm 296x575x575 mm 296x575x575 mm 296x575x575 mm 64x730x730 kg 16,5 kg 16,5 kg 18 kg 2,5 ADMI28HG ADMI36HG 2-way duct (200 mm each) Plenum ADMI50HG ADMI70HG 3-way duct (200 mm each) Plenum m3/h 600-510-440 m3/h 600-510-440 Ducted units l/h 0,8 3 + Auto l/h 1,5 3 + Auto dB(A) 45-43-40 dB(A) 45-43-40 l/h 2,3 l/h 2,6 dB(A) 45-38-33 dB(A) 48-40-37 mm 266x926x571 mm 266x926x571 mm 266x926x200 mm 266x1132x571 mm 266x1132x571 mm 266x1132x200 kg 30 kg 30 kg 6 kg 35 kg 35 kg 7,5 AFMI28HG FCMI36HG FCMI50HG FCMI70HG m3/h 760-630-550 m3/h 1000-700-600 m3/h m3/h m3/h m3/h 400-360-300 700-590-500 800-700-590 840-770-670 3 + Auto 3 + Auto Floor & Floor/ceiling units l/h 1,0 3 + Auto l/h 1,3 3 + Auto l/h 2,3 3 + Auto l/h 3,3 3 + Auto dB(A) dB(A) dB(A) dB(A) 43-40-34 47-43-38 51-47-43 52-49-46 mm mm mm mm 700x560x200 680x900x190 680x900x190 680x900x190 kg kg kg kg 18,6 23,5 23,5 23,5 NB: For the indoor units capacity see the matching table. Cassette units Hi-wall units Floor/Ceiling units Floor units w w w. a r g o c l i m a . c o m Ducted units 55 M U LT I S P L I T D C I N V E R T E R R 4 1 0 A improve your life w w w. a r g o c l i m a . c o m DUAL/TRIAL SPLIT PIPE LINE TABLES 56 QUADRI SPLIT PIPE LINE TABLE PA C K A G E / M U LT I PA C K A G E D C I N V E R T E R R 4 1 0 A w w w. a r g o c l i m a . c o m improve your life PACKAGE WALL DC INVERTER R410A improve your life AWS71 PRODUCT NAME Indoor unit Outdoor unit Features Cooling/Heating capacity - nominal (min-max) Energy label class E.E.R. / C.O.P. Air flowrate Indoor (h.m.l.) Dehumidification Fan speeds (Indoor / Outdoor) Sound pressure Indoor (h.m.l.) Sound pressure Outdoor (h.) Power supply Running consumption Annual energy cons.- cooling mode (500h) - Directive 2002/31/CE Compressor type Refrigerant type Liquid pipe diameter Gas pipe diameter Max. pipe lenght with gas standard charge Max. pipe lenght with gas additional charge Gas additional charge Max. height between units (Outdoor on top) Max. height between units (Indoor on top) Net weight Indoor / Outdoor Net dimension Indoor (H./W./D.) Net dimension Outdoor (H./W./D.) AWS71PH AES71PIH Units kW BTU/h kcal/h ABCDEFG (kW/kW) m³/h l/h n° dB(A) dB(A) V/Ph/Hz kW kWh mm(inch") mm(inch") m m gr/m m m Kg mm mm Cooling Heating 7,10 (2,2-8,0) 8,00 (2,2-9,0) 24.000 27.000 6.100 6.880 B B 3,01 3,54 1.140-1.020-840 4,0 3 + Auto / 3 (Auto) 41-37-34 49 230/1/50 2,36 2,26 1.180 DCInverter Twin Rotary R410A 9,52(3/8") 15,88(5/8") 30 50 40 50 30 21/58 330x1.140x228 780x940x340 The technical data here indicated are in compliance with the European standard EN14511 - Directive 2002/31/EC Features High wall straight cooling and heat pump air conditioner PAM DC Inverter technology w w w. a r g o c l i m a . c o m Automatic change-over between cooling and heating modes Special function during heat pump start-up and defrosting cycle to avoid cool air emission in the room Among controls available for this kind of indoor unit (all optional): - the infrared remote control, equipped with a 24h digital timer and a temperature sensor granting automatically the the best comfort conditions ("I Feel" feature); - a special wired controller with configuration, diagnostic and weekly timer capabilities Night set back capability Dry function New three-speed tangential fan by remote control, granting a better and low noise air diffusion Horizontal flap swinging or to be set to a fixed position by remote control Vertical flap by manual control Anti-mould and anti-bacteria washable filters Dynamic refrigerant control by DC Inverter compressor and circuit, electronic valve and fuzzy logic managed by a powerful microprocessor Auto restart after a power supply black out Electronic protection against over-pressures Wide operating range with outdoor air temperatures up to -15°C in both cooling and heating modes Single-phase (230/1/50) power supply thanks to DC Inverter technology low consumption 58 Double rotary compressor PACKAGE CASSETTE DC INVERTER R410A improve your life ASS71 PRODUCT NAME Indoor unit Outdoor unit Features ASS71PH AES71PIH Units kW BTU/h kcal/h ABCDEFG (kW/kW) m3/h l/h n° dB(A) dB(A) V/Ph/Hz kW kWh Cooling/Heating capacity Energy label class E.E.R. / C.O.P. Air flowrate Indoor (h.m.l.) Dehumidification Fan speeds (Indoor / Outdoor) Sound pressure Indoor (h.m.l.) Sound pressure Outdoor (h.) Power supply Running consumption Annual energy cons.- cooling mode (500h) - Directive 2002/31/CE Compressor type Refrigerant type Liquid pipe diameter Gas pipe diameter Max. pipe lenght with gas standard charge Max. pipe lenght with gas additional charge Gas additional charge Max. height between units (Outdoor on top) Max. height between units (Indoor on top) Net weight Indoor (with grille) / Outdoor Net dimension Indoor (with grille) (H./W./D.) Net dimension Outdoor (H./W./D.) mm(inch") mm(inch") m m gr/m m m Kg mm mm Cooling Heating 7,10 (2,2-8,0) 8,00 (2,2-9,0) 24.000 27.000 6.100 6.880 A A 3,33 3,86 1.140-1.020-840 3,6 3 + Auto / 3 (Auto) 47-45-41 49 230/1/50 2,13 2,07 1.065 DCInverter Twin Rotary R410A 9,52(3/8") 15,88(5/8") 30 50 40 50 30 28/58 338x860x860 780x940x340 The technical data here indicated are in compliance with the European standard EN14511 - Directive 2002/31/EC Features Cassette straight cooling and heat pump air conditioner PAM DC Inverter technology Special function during heat pump start-up and defrosting cycle to avoid cool air emission in the room Among controls available for this kind of indoor unit (all optional): - the infrared remote control, equipped with a 24h digital timer and a temperature sensor granting automatically the the best comfort conditions ("I Feel" feature); - a special wired controller with configuration, diagnostic and weekly timer capabilities Night set back capability Dry function New three-speed centrifugal fan by remote control, granting a better and low noise air diffusion Special system to avoid condensate dripping from air outlet ribs Four horizontal flaps swinging or to be set on a fixed position by remote control Anti-mould and anti-bacteria washable filters Integrated pump for condensate discharge Possibility to have a connection for fresh air intake Double-way of air duct in adjacent rooms through pre-drilled holes Dynamic refrigerant control by DC Inverter compressor and circuit, electronic valve and fuzzy logic managed by a powerful microprocessor Auto restart after a power supply black out Electronic protection against over-pressures w w w. a r g o c l i m a . c o m Automatic change-over between cooling and heating modes Wide operating range with outdoor air temperatures up to -15°C in both cooling and heating modes Single-phase (230/1/50) power supply thanks to DC Inverter technology low consumption Double rotary compressor 59 PACKAGE CASSETTE DC INVERTER R410A improve your life ASS100 PRODUCT NAME Indoor unit Outdoor unit Features Cooling/Heating capacity Energy label class E.E.R. / C.O.P. Air flowrate Indoor (h.m.l.) Dehumidification Fan speeds (Indoor / Outdoor) Sound pressure Indoor (h.m.l.) Sound pressure Outdoor (h.) Power supply Running consumption Annual energy cons.- cooling mode (500h) - Directive 2002/31/CE Compressor type Refrigerant type Liquid pipe diameter Gas pipe diameter Max. pipe lenght with gas standard charge Max. pipe lenght with gas additional charge Gas additional charge Max. height between units (Outdoor on top) Max. height between units (Indoor on top) Net weight Indoor (with grille) / Outdoor Net dimension Indoor (with grille) (H./W./D.) Net dimension Outdoor (H./W./D.) ASS100PH AES100PIH Units kW BTU/h kcal/h ABCDEFG (kW/kW) m3/h l/h n° dB(A) dB(A) V/Ph/Hz kW kWh mm(inch") mm(inch") m m gr/m m m Kg mm mm Cooling Heating 10,00 (2,2-11,2) 11,20 (2,2-12,50) 34.000 38.000 8.600 9.630 A A 3,21 3,78 1.920-1.680-1.320 4,6 3 + Auto / 3 (Auto) 53-50-46 52 230/1/50 3,12 2,96 1.560 DCInverter Twin Rotary R410A 9,52(3/8") 15,88(5/8") 30 50 40 50 30 35/65 338x1.150x860 780x940x340 The technical data here indicated are in compliance with the European standard EN14511 - Directive 2002/31/EC Features Cassette straight cooling and heat pump air conditioner PAM DC Inverter technology w w w. a r g o c l i m a . c o m Automatic change-over between cooling and heating modes Special function during heat pump start-up and defrosting cycle to avoid cool air emission in the room Among controls available for this kind of indoor unit (all optional): - the infrared remote control, equipped with a 24h digital timer and a temperature sensor granting automatically the the best comfort conditions ("I Feel" feature); - a special wired controller with configuration, diagnostic and weekly timer capabilities Night set back capability Dry function New three-speed centrifugal fan by remote control, granting a better and low noise air diffusion Special system to avoid condensate dripping from air outlet ribs Four horizontal flaps swinging or to be set on a fixed position by remote control Anti-mould and anti-bacteria washable filters Integrated pump for condensate discharge Possibility to have a connection for fresh air intake Double-way of air duct in adjacent rooms through pre-drilled holes Dynamic refrigerant control by DC Inverter compressor and circuit, electronic valve and fuzzy logic managed by a powerful microprocessor Auto restart after a power supply black out Electronic protection against over-pressures Wide operating range with outdoor air temperatures up to -15°C in both cooling and heating modes Single-phase (230/1/50) power supply thanks to DC Inverter technology low consumption 60 Double rotary compressor PACKAGE CASSETTE DC INVERTER R410A improve your life ASS125 PRODUCT NAME Indoor unit Outdoor unit Features ASS125PH AES125PIH Units kW BTU/h kcal/h ABCDEFG (kW/kW) m3/h l/h n° dB(A) dB(A) V/Ph/Hz kW kWh Cooling/Heating capacity Energy label class E.E.R. / C.O.P. Air flowrate Indoor (h.m.l.) Dehumidification Fan speeds (Indoor / Outdoor) Sound pressure Indoor (h.m.l.) Sound pressure Outdoor (h.) Power supply Running consumption Annual energy cons.- cooling mode (500h) - Directive 2002/31/CE Compressor type Refrigerant type Liquid pipe diameter Gas pipe diameter Max. pipe lenght with gas standard charge Max. pipe lenght with gas additional charge Gas additional charge Max. height between units (Outdoor on top) Max. height between units (Indoor on top) Net weight Indoor (with grille) / Outdoor Net dimension Indoor (with grille) (H./W./D.) Net dimension Outdoor (H./W./D.) mm(inch") mm(inch") m m gr/m m m Kg mm mm Cooling Heating 12,50 (2,7-14,0) 14,00 (2,7-16,00) 42.500 48.000 10.750 12.040 A A 3,24 3,66 1.920-1.680-1.320 6,3 3 + Auto / 3 (Auto) 53-50-46 53 230/1/50 3,86 3,83 1.930 DCInverter Twin Rotary R410A 9,52(3/8") 15,88(5/8") 30 50 40 50 30 35/100 338x1.150x860 1.230x940x340 The technical data here indicated are in compliance with the European standard EN14511 - Directive 2002/31/EC Features Cassette straight cooling and heat pump air conditioner PAM DC Inverter technology Special function during heat pump start-up and defrosting cycle to avoid cool air emission in the room Among controls available for this kind of indoor unit (all optional): - the infrared remote control, equipped with a 24h digital timer and a temperature sensor granting automatically the the best comfort conditions ("I Feel" feature); - a special wired controller with configuration, diagnostic and weekly timer capabilities Night set back capability Dry function New three-speed centrifugal fan by remote control, granting a better and low noise air diffusion Special system to avoid condensate dripping from air outlet ribs Four horizontal flaps swinging or to be set on a fixed position by remote control Anti-mould and anti-bacteria washable filters Integrated pump for condensate discharge Possibility to have a connection for fresh air intake Double-way of air duct in adjacent rooms through pre-drilled holes Dynamic refrigerant control by DC Inverter compressor and circuit, electronic valve and fuzzy logic managed by a powerful microprocessor Auto restart after a power supply black out Electronic protection against over-pressures w w w. a r g o c l i m a . c o m Automatic change-over between cooling and heating modes Wide operating range with outdoor air temperatures up to -15°C in both cooling and heating modes Single-phase (230/1/50) power supply thanks to DC Inverter technology low consumption Double rotary compressor 61 PACKAGE DUCTED DC INVERTER R410A improve your life ADS71 PRODUCT NAME Indoor unit Outdoor unit Features ADS71PH AES71PIH Units kW BTU/h kcal/h ABCDEFG (kW/kW) m3/h l/h mm W.G. n° dB(A) dB(A) dB(A) dB(A) V/Ph/Hz kW kWh Cooling/Heating capacity - nominal (min-max) Energy label class E.E.R. / C.O.P. Air flowrate (h.m.l.) Dehumidification External static pressure (min-max) Fan speeds (Indoor / Outdoor) Sound power Indoor (h.m.l.) Sound pressure Indoor (h.m.l.) at discharge plenum connection Sound pressure Indoor at ducts exit Sound pressure Outdoor (h.) Power supply Running consumption - nominal (min-max) Annual energy cons.- cooling mode (500h) - Directive 2002/31/CE Compressor type Refrigerant type Liquid pipe diameter Gas pipe diameter Max. pipe lenght with gas standard charge Max. pipe lenght with gas additional charge Gas additional charge Max. height between units (Outdoor on top) Max. height between units (Indoor on top) Ducts diameter Net weight Indoor / Outdoor Net dimension Indoor (H./W./D.) Net dimension Outdoor (H./W./D.) mm(inch") mm(inch") m m gr/m m m mm Kg mm mm Cooling Heating 7,10 (2,2-8,0) 8,00 (2,2-9,0) 24.000 27.000 6.100 6.880 C C 2,83 3,35 1.080-900-780 3,5 5-10 3 + Auto / 3 (Auto) 43-39-36 34-30-37 < 20 49 230/1/50 2,51 2,39 1.255 DCInverter Twin Rotary R410A 9,52(3/8") 15,88(5/8") 30 50 40 50 30 200 32/58 310x1.000x630 780x940x340 The technical data here indicated are in compliance with the European standard EN14511 - Directive 2002/31/EC Features Ducted straight cooling and heat pump air conditioner PAM DC Inverter technology w w w. a r g o c l i m a . c o m Three-way duct connection Automatic change-over between cooling and heating modes Special function during heat pump start-up and defrosting cycle to avoid cool air emission in the room Among controls available for this kind of indoor unit (all optional): - the infrared remote control, equipped with a 24h digital timer and a temperature sensor granting automatically the the best comfort conditions ("I Feel" feature); - a special wired controller with configuration, diagnostic and weekly timer capabilities Night set back capability Dry function New centrifugal fan, with double static pressure, three speeds by remote control, granting a better and low noise air diffusion Possibility to increase the Static Pressure Connection for fresh air intake by optional kit with anti-mould and anti-bacteria filter; this kit makes possible the direct access to the internal components for maintenance activities Integrated pump for condensate discharge Dynamic refrigerant control by DC Inverter compressor and circuit, electronic valve and fuzzy logic managed by a powerful microprocessor Auto restart after a power supply black out Electronic protection against over-pressures Wide operating range with outdoor air temperatures up to -15°C in both cooling and heating modes Single-phase (230/1/50) power supply thanks to DC Inverter technology low consumption 62 Double rotary compressor PACKAGE DUCTED DC INVERTER R410A improve your life ADS100 PRODUCT NAME Indoor unit Outdoor unit Features Cooling/Heating capacity - nominal (min-max) Energy label class E.E.R. / C.O.P. Air flowrate (h.m.l.) Dehumidification External static pressure (min-max) Fan speeds (Indoor / Outdoor) Sound power Indoor (h.m.l.) Sound pressure Indoor (h.m.l.) at discharge plenum connection Sound pressure Indoor at ducts exit Sound pressure Outdoor (h.) Power supply Running consumption - nominal (min-max) Annual energy cons.- cooling mode (500h) - Directive 2002/31/CE Compressor type Refrigerant type Liquid pipe diameter Gas pipe diameter Max. pipe lenght with gas standard charge Max. pipe lenght with gas additional charge Gas additional charge Max. height between units (Outdoor on top) Max. height between units (Indoor on top) Ducts diameter Net weight Indoor / Outdoor Net dimension Indoor (H./W./D.) Net dimension Outdoor (H./W./D.) ADS100PH AES100PIH Units kW BTU/h kcal/h ABCDEFG (kW/kW) m3/h l/h mm W.G. n° dB(A) dB(A) dB(A) dB(A) V/Ph/Hz kW kWh mm(inch") mm(inch") m m gr/m m m mm Kg mm mm Cooling Heating 10,00 (2,2-11,2) 11,20 (2,2-12,50) 34.000 38.000 8.600 9.630 C C 2,82 3,39 1.800-1.560-1.260 4,2 5-10 3 + Auto / 3 (Auto) 47-42-40 38-33-31 < 20 52 230/1/50 3,55 3,30 1.775 DCInverter Twin Rotary R410A 9,52(3/8") 15,88(5/8") 30 50 40 50 30 200 47/65 310x1.480x630 780x940x340 The technical data here indicated are in compliance with the European standard EN14511 - Directive 2002/31/EC Features Ducted straight cooling and heat pump air conditioner PAM DC Inverter technology Automatic change-over between cooling and heating modes Special function during heat pump start-up and defrosting cycle to avoid cool air emission in the room Among controls available for this kind of indoor unit (all optional): - the infrared remote control, equipped with a 24h digital timer and a temperature sensor granting automatically the the best comfort conditions ("I Feel" feature); - a special wired controller with configuration, diagnostic and weekly timer capabilities Night set back capability Dry function New centrifugal fan, with double static pressure, three speeds by remote control, granting a better and low noise air diffusion Possibility to increase the Static Pressure Connection for fresh air intake by optional kit with anti-mould and anti-bacteria filter; this kit makes possible the direct access to the internal components for maintenance activities Integrated pump for condensate discharge Dynamic refrigerant control by DC Inverter compressor and circuit, electronic valve and fuzzy logic managed by a powerful microprocessor Auto restart after a power supply black out Electronic protection against over-pressures w w w. a r g o c l i m a . c o m Four-way duct connection Wide operating range with outdoor air temperatures up to -15°C in both cooling and heating modes Single-phase (230/1/50) power supply thanks to DC Inverter technology low consumption Double rotary compressor 63 PACKAGE DUCTED DC INVERTER R410A improve your life ADS125 PRODUCT NAME Indoor unit Outdoor unit Features ADS125PH AES125PIH Units kW BTU/h kcal/h ABCDEFG (kW/kW) m3/h l/h mm W.G. n° dB(A) dB(A) dB(A) dB(A) V/Ph/Hz kW kWh Cooling/Heating capacity - nominal (min-max) Energy label class E.E.R. / C.O.P. Air flowrate (h.m.l.) Dehumidification External static pressure (min-max) Fan speeds (Indoor / Outdoor) Sound power Indoor (h.m.l.) Sound pressure Indoor (h.m.l.) at discharge plenum connection Sound pressure Indoor at ducts exit Sound pressure Outdoor (h.) Power supply Running consumption - nominal (min-max) Annual energy cons.- cooling mode (500h) - Directive 2002/31/CE Compressor type Refrigerant type Liquid pipe diameter Gas pipe diameter Max. pipe lenght with gas standard charge Max. pipe lenght with gas additional charge Gas additional charge Max. height between units (Outdoor on top) Max. height between units (Indoor on top) Ducts diameter Net weight Indoor / Outdoor Net dimension Indoor (H./W./D.) Net dimension Outdoor (H./W./D.) mm(inch") mm(inch") m m gr/m m m mm Kg mm mm Cooling Heating 12,50 (2,7-14,0) 14,00 (2,7-16,00) 42.500 48.000 10.750 12.040 C C 2,87 3,26 1.980-1.560-1.320 6,6 5-10 3 + Auto / 3 (Auto) 49-46-42 40-37-33 < 20 53 230/1/50 4,36 4,29 2.180 DCInverter Twin Rotary R410A 9,52(3/8") 15,88(5/8") 30 50 40 50 30 200 47/100 310x1.480x630 1.230x940x340 The technical data here indicated are in compliance with the European standard EN14511 - Directive 2002/31/EC Features Ducted straight cooling and heat pump air conditioner PAM DC Inverter technology w w w. a r g o c l i m a . c o m Four-way duct connection Automatic change-over between cooling and heating modes Special function during heat pump start-up and defrosting cycle to avoid cool air emission in the room Among controls available for this kind of indoor unit (all optional): - the infrared remote control, equipped with a 24h digital timer and a temperature sensor granting automatically the the best comfort conditions ("I Feel" feature); - a special wired controller with configuration, diagnostic and weekly timer capabilities Night set back capability Dry function New centrifugal fan, with double static pressure, three speeds by remote control, granting a better and low noise air diffusion Possibility to increase the Static Pressure Connection for fresh air intake by optional kit with anti-mould and anti-bacteria filter; this kit makes possible the direct access to the internal components for maintenance activities Integrated pump for condensate discharge Dynamic refrigerant control by DC Inverter compressor and circuit, electronic valve and fuzzy logic managed by a powerful microprocessor Auto restart after a power supply black out Electronic protection against over-pressures Wide operating range with outdoor air temperatures up to -15°C in both cooling and heating modes Single-phase (230/1/50) power supply thanks to DC Inverter technology low consumption 64 Double rotary compressor PACKAGE CEILING DC INVERTER R410A improve your life ACS71 PRODUCT NAME Indoor unit Outdoor unit Features Cooling/Heating capacity - nominal (min-max) Energy label class E.E.R. / C.O.P. Air flowrate Indoor (h.m.l.) Dehumidification Fan speeds (Indoor / Outdoor) Sound pressure Indoor (h.m.l.) Sound pressure Outdoor (h.) Power supply Running consumption Annual energy cons.- cooling mode (500h) - Directive 2002/31/CE Compressor type Refrigerant type Liquid pipe diameter Gas pipe diameter Max. pipe lenght with gas standard charge Max. pipe lenght with gas additional charge Gas additional charge Max. height between units (Outdoor on top) Max. height between units (Indoor on top) Net weight Indoor / Outdoor Net dimension Indoor (H./W./D.) Net dimension Outdoor (H./W./D.) ACS71PH AES71PIH Units kW BTU/h kcal/h ABCDEFG (kW/kW) m³/h l/h n° dB(A) dB(A) V/Ph/Hz kW kWh mm(inch") mm(inch") m m gr/m m m Kg mm mm Cooling Heating 7,10 (2,2-8,0) 8,00 (2,2-9,0) 24.000 27.000 6.100 6.880 B B 3,02 3,56 1.098-900-840 3,0 3 + Auto / 3 (Auto) 38-36-33 49 230/1/50 2,35 2,25 1.175 DCInverter Twin Rotary R410A 9,52(3/8") 15,88(5/8") 30 50 40 50 30 25/58 210x1.180x680 780x940x340 The technical data here indicated are in compliance with the European standard EN14511 - Directive 2002/31/EC Features Ceiling straight cooling and heat pump air conditioner PAM DC Inverter technology Special function during heat pump start-up and defrosting cycle to avoid cool air emission in the room Among controls available for this kind of indoor unit (all optional): - the infrared remote control, equipped with a 24h digital timer and a temperature sensor granting automatically the the best comfort conditions ("I Feel" feature); - a special wired controller with configuration, diagnostic and weekly timer capabilities Night set back capability Dry function Three-speed centrifugal fan by remote control, granting a better and low noise air diffusion Horizontal flap swinging or to be set on a fixed position by remote control, with automatic positioning according to selected mode (cooling or heating) Anti-mould and anti-bacteria washable filters Possibility to have a connection for fresh air intake Dynamic refrigerant control by DC Inverter compressor and circuit, electronic valve and fuzzy logic managed by a powerful microprocessor Auto restart after a power supply black out Electronic protection against over-pressures Wide operating range with outdoor air temperatures up to -15°C in both cooling and heating modes w w w. a r g o c l i m a . c o m Automatic change-over between cooling and heating modes Single-phase (230/1/50) power supply thanks to DC Inverter technology low consumption Double rotary compressor 65 PACKAGE CEILING DC INVERTER R410A improve your life ACS100 PRODUCT NAME Indoor unit Outdoor unit Features ACS100PH AES100PIH Units kW BTU/h kcal/h ABCDEFG (kW/kW) m³/h l/h n° dB(A) dB(A) V/Ph/Hz kW kWh Cooling/Heating capacity - nominal (min-max) Energy label class E.E.R. / C.O.P. Air flowrate Indoor (h.m.l.) Dehumidification Fan speeds (Indoor / Outdoor) Sound pressure Indoor (h.m.l.) Sound pressure Outdoor (h.) Power supply Running consumption Annual energy cons.- cooling mode (500h) - Directive 2002/31/CE Compressor type Refrigerant type Liquid pipe diameter Gas pipe diameter Max. pipe lenght with gas standard charge Max. pipe lenght with gas additional charge Gas additional charge Max. height between units (Outdoor on top) Max. height between units (Indoor on top) Net weight Indoor / Outdoor Net dimension Indoor (H./W./D.) Net dimension Outdoor (H./W./D.) h h ld h d d mm(inch") mm(inch") m m gr/m m m Kg mm mm l h h Cooling Heating 10,00 (2,2-11,2) 11,20 (2,2-12,50) 34.000 38.000 8.600 9.630 B A 3,04 3,67 1.650-1.380-1.200 3,9 3 + Auto / 3 (Auto) 41-38-35 52 230/1/50 3,29 3,67 1.645 DCInverter Twin Rotary R410A 9,52(3/8") 15,88(5/8") 30 50 40 50 30 33/65 210x1.595x680 780x940x340 d d The technical data here indicated are in compliance with the European standard EN14511 - Directive 2002/31/EC Features Ceiling straight cooling and heat pump air conditioner PAM DC Inverter technology w w w. a r g o c l i m a . c o m Automatic change-over between cooling and heating modes Special function during heat pump start-up and defrosting cycle to avoid cool air emission in the room Among controls available for this kind of indoor unit (all optional): - the infrared remote control, equipped with a 24h digital timer and a temperature sensor granting automatically the the best comfort conditions ("I Feel" feature); - a special wired controller with configuration, diagnostic and weekly timer capabilities Night set back capability Dry function Three-speed centrifugal fan by remote control, granting a better and low noise air diffusion Horizontal flap swinging or to be set on a fixed position by remote control, with automatic positioning according to selected mode (cooling or heating) Anti-mould and anti-bacteria washable filters Possibility to have a connection for fresh air intake Dynamic refrigerant control by DC Inverter compressor and circuit, electronic valve and fuzzy logic managed by a powerful microprocessor Auto restart after a power supply black out Electronic protection against over-pressures Wide operating range with outdoor air temperatures up to -15°C in both cooling and heating modes Single-phase (230/1/50) power supply thanks to DC Inverter technology low consumption 66 Double rotary compressor PACKAGE CEILING DC INVERTER R410A improve your life ACS125 PRODUCT NAME Indoor unit Outdoor unit Features Cooling/Heating capacity - nominal (min-max) Energy label class E.E.R. / C.O.P. Air flowrate Indoor (h.m.l.) Dehumidification Fan speeds (Indoor / Outdoor) Sound pressure Indoor (h.m.l.) Sound pressure Outdoor (h.) Power supply Running consumption Annual energy cons.- cooling mode (500h) - Directive 2002/31/CE Compressor type Refrigerant type Liquid pipe diameter Gas pipe diameter Max. pipe lenght with gas standard charge Max. pipe lenght with gas additional charge Gas additional charge Max. height between units (Outdoor on top) Max. height between units (Indoor on top) Net weight Indoor / Outdoor Net dimension Indoor (H./W./D.) Net dimension Outdoor (H./W./D.) ACS125PH AES125PIH Units kW BTU/h kcal/h ABCDEFG (kW/kW) m³/h l/h n° dB(A) dB(A) V/Ph/Hz kW kWh mm(inch") mm(inch") m m gr/m m m Kg mm mm Cooling Heating 12,50 (2,7-14,0) 14,00 (2,7-16,00) 42.500 48.000 10.750 12.040 B B 3,03 3,44 1.800-1.560-1.320 5,6 3 + Auto / 3 (Auto) 43-40-37 53 230/1/50 4,12 4,07 2.060 DCInverter Twin Rotary R410A 9,52(3/8") 15,88(5/8") 30 50 40 50 30 35/100 210x1.595x680 1.230x940x340 The technical data here indicated are in compliance with the European standard EN14511 - Directive 2002/31/EC Features Ceiling straight cooling and heat pump air conditioner PAM DC Inverter technology Special function during heat pump start-up and defrosting cycle to avoid cool air emission in the room Among controls available for this kind of indoor unit (all optional): - the infrared remote control, equipped with a 24h digital timer and a temperature sensor granting automatically the the best comfort conditions ("I Feel" feature); - a special wired controller with configuration, diagnostic and weekly timer capabilities Night set back capability Dry function Three-speed centrifugal fan by remote control, granting a better and low noise air diffusion Horizontal flap swinging or to be set on a fixed position by remote control, with automatic positioning according to selected mode (cooling or heating) Anti-mould and anti-bacteria washable filters Possibility to have a connection for fresh air intake Dynamic refrigerant control by DC Inverter compressor and circuit, electronic valve and fuzzy logic managed by a powerful microprocessor Auto restart after a power supply black out Electronic protection against over-pressures Wide operating range with outdoor air temperatures up to -15°C in both cooling and heating modes w w w. a r g o c l i m a . c o m Automatic change-over between cooling and heating modes Single-phase (230/1/50) power supply thanks to DC Inverter technology low consumption Double rotary compressor 67 MULTIPACKAGE DC INVERTER R410A improve your life AES71PH AES100PH Cooling: 7,1 kW Heating: 8 kW Cooling: 10 kW AES125PH Cooling: 12,5 kW Heating: 11,2 kW Heating: 14 kW INDOOR UNITS MATCHING TABLE AES71PIH OUTDOOR UNIT MODEL --> Indoor unit models 1 unit Connectable Indoor units 2 units also mixed Type AWS71PH ASS71PH ACS71PH ADS71PH AWS36PH ASS36PH ADS36PH FC36PHG High-wall Cassette Underceiling Ducted High-wall Cassette Ducted Floor/Ceiling Cooling Indoor capacity (kW) A B C D 7,10 7,10 7,10 7,10 3,55 3,55 3,55 3,55 3,55 3,55 3,55 3,55 - Total capacity kW 7,1 (2,2-8,0) 7,1 (2,2-8,0) 7,1 (2,2-8,0) 7,1 (2,2-8,0) 7,1 (2,2-8,0) 7,1 (2,2-8,0) 7,1 (2,2-8,0) 7,1 (2,2-8,0) Cooling Indoor capacity (kW) A B C D 10,00 10,00 10,00 5,00 5,00 5,00 5,00 5,00 5,00 5,00 5,00 - Total capacity kW 10,0 (2,2-11,2) 10,0 (2,2-11,2) 10,0 (2,2-11,2) 10,0 (2,2-11,2) 10,0 (2,2-11,2) 10,0 (2,2-11,2) 10,0 (2,2-11,2) 1 unit w w w. a r g o c l i m a . c o m Connectable Indoor units 68 2 units also mixed Type ASS100PH ACS100PH ADS100PH AWS56PH ASS56PH ADS56PH FC56PHG Cassette Underceiling Ducted High-wall Cassette Ducted Floor/Ceiling Cooling Indoor capacity (kW) A B C D 12,50 12,50 12,50 6,25 6,25 6,25 6,25 6,25 6,25 6,25 6,25 4,16 4,16 4,16 4,16 4,16 4,16 4,16 4,16 4,16 4,16 4,16 4,16 3,12 3,12 3,12 3,12 3,12 3,12 3,12 3,12 3,12 3,12 3,12 3,12 3,12 3,12 3,12 3,12 Total capacity kW 12,5 (2,7-14,0) 12,5 (2,7-14,0) 12,5 (2,7-14,0) 12,5 (2,7-14,0) 12,5 (2,7-14,0) 12,5 (2,7-14,0) 12,5 (2,7-14,0) 12,5 (2,7-14,0) 12,5 (2,7-14,0) 12,5 (2,7-14,0) 12,5 (2,7-14,0) 12,5 (2,7-14,0) 12,5 (2,7-14,0) 12,5 (2,7-14,0) 12,5 (2,7-14,0) 1 unit Connectable Indoor units 2 units also mixed 3 units 4 units also mixed Note n.1 Note n.2 Note n.3 Type ASS125PH ACS125PH ADS125PH AWS71PH ASS71PH ACS71PH ADS71PH AWS45PH ASS45PH ADS45PH FC45PHG AWS36PH ASS36PH ADS36PH FC36PHG Heating Indoor capacity (kW) A B C D 11,20 11,20 11,20 5,60 5,60 5,60 5,60 5,60 5,60 5,60 5,60 - Total capacity kW 11,2 (2,2-12,5) 11,2 (2,2-12,5) 11,2 (2,2-12,5) 11,2 (2,2-12,5) 11,2 (2,2-12,5) 11,2 (2,2-12,5) 11,2 (2,2-12,5) AES125PIH OUTDOOR UNIT MODEL --> Indoor unit models Total capacity kW 8,0 (2,2-9,0) 8,0 (2,2-9,0) 8,0 (2,2-9,0) 8,0 (2,2-9,0) 8,0 (2,2-9,0) 8,0 (2,2-9,0) 8,0 (2,2-9,0) 8,0 (2,2-9,0) AES100PIH OUTDOOR UNIT MODEL --> Indoor unit models Heating Indoor capacity (kW) A B C D 8,00 8,00 8,00 8,00 4,00 4,00 4,00 4,00 4,00 4,00 4,00 4,00 - Cassette Underceiling Ducted High-wall Cassette Underceiling Ducted High-wall Cassette Ducted Floor/Ceiling High-wall Cassette Ducted Floor/Ceiling Heating Indoor capacity (kW) A B C D 14,00 14,00 14,00 7,00 7,00 7,00 7,00 7,00 7,00 7,00 7,00 4,66 4,66 4,66 4,66 4,66 4,66 4,66 4,66 4,66 4,66 4,66 4,66 3,50 3,50 3,50 3,50 3,50 3,50 3,50 3,50 3,50 3,50 3,50 3,50 3,50 3,50 3,50 3,50 Total capacity kW 14,0 (2,7-16,0) 14,0 (2,7-16,0) 14,0 (2,7-16,0) 14,0 (2,7-16,0) 14,0 (2,7-16,0) 14,0 (2,7-16,0) 14,0 (2,7-16,0) 14,0 (2,7-16,0) 14,0 (2,7-16,0) 14,0 (2,7-16,0) 14,0 (2,7-16,0) 14,0 (2,7-16,0) 14,0 (2,7-16,0) 14,0 (2,7-16,0) 14,0 (2,7-16,0) Indoor units names contain one number identifying their nominal capacity in kW (i.e.: 71=7,1kW=25000 BTU/h) The Indoor units here indicated have the same caracteristics as the Indoor units used with the MultiSet DCInverter systems described in the following pages; the only difference is the type of pcb installed. The control systems (wireless, wired, weekly timer, system controller, etc...) are equal to those used for the MultiSet DCInverter systems described in the following pages. MULTIPACKAGE DC INVERTER R410A Features improve your life Straight cooling and heat pump air conditioners series Package DC Inverter R410A can be set with two, three or four indoor units operating simultaneously; this type of installation is the best for big shops, open space offices, restaurants,... The installation of more indoor units in one only big room allows a better diffusion of the conditioned air The MultiPackage DC Inverter R410A control systems allow a sophisticated control of single and multi-package configurations by zones, with a maximum of 256 indoor units being managed by one only intelligent controller Hi-w wall units In addition to single-Package DC Inverter R410A features, change-over functionality and Cluster control, both in cooling and heating modes Two-unit matchings (duo) are realized with a 2-way distribution joint kit Three-unit matchings (trio) are realized with a 3-way distribution joint kit Four-unit matchings (quartet) are realized with 3 distribution joint kits (2-way), in tree configuration (1 > 2 > 4) Cassette units Special function during heat pump start-up and defrosting cycle to avoid cool air emission in the room "I Feel" feature, granting the best comfort conditions Night set back capability Ducted units Dynamic refrigerant control by DC Inverter compressor and circuit, electronic valve and fuzzy logic managed by a powerful microprocessor Auto restart after a power supply black out Electronic protection against over-pressures Ceiling units Wide operating range with outdoor air temperatures up to -15°C in both cooling and heating modes Single-phase (230/1/50) power supply thanks to DC Inverter technology low consumption Double rotary compressor w w w. a r g o c l i m a . c o m All MultiPackage DC Inverter R410A systems may be controlled by infrared remote control with digital 24h timer and temperature sensor inside or by a special wired controller with configuration, diagnostic and weekly timer capabilities; in the following pages are shown all the MultiPackage DC Inverter R410A control systems Floor/Ceiling units 69 MULTIPACKAGE DC INVERTER R410A improve your life PIPES MAX PIPES LENGHT AND MAX HEIGHT DIFFERENCE BETWEEN UNITS Description Pipes lenght from the Outdoor unit to the farthest Indoor unit L+l1 L+l2 Trio L+l1, L+l2 L+l3 Pipes lenght after the first distribution l1,l2 l1,l2,l3 w w w. a r g o c l i m a . c o m Difference between maximum and minimum pipes lenght , after the first distribution 70 Max. pipes lenght difference at distribution joint no. 1 Max. pipes lenght difference at distribution joint no. 2 Max. height difference between units (Outdoor on top) Max. height difference between units (Indoor on top) Max. height difference between Indoor units Duo l1>l2>l3 l1-l2 l1-l3 l2-l3 l1>l2 l1-l2 - H2 (in duo, trio and quartet configuration) Quartet L+L1+l1, L+L1+l2 L+L2+l3, L+L2+l4 L1+l1, L1+l2 L2+l3, L2+l4 Lenght (m) 50 15 Max: L2+l4 Min: L1+l1 10 (L2+l4)-(L1+l1) - L2>L1 L2-L1 10 - l2>l1 l2-l1 10 l4>l3 l4-l3 H1 30 H1 15 H2, H3, H4 H2, H3, H4, H5, H6, H7 0,5 PIPES DIAMETER Type capacity of indoor units --> Liquid pipe diameter mm(inch") Gas pipe diameter mm(inch") 36 6,35(1/4") 12,7(1/2") 45 6,35(1/4") 12,7(1/2") 56 6,35(1/4") 12,7(1/2") 71 9,52(3/8") 15,88(5/8") 100 9,52(3/8") 15,88(5/8") 125 9,52(3/8") 15,88(5/8") MULTIPACKAGE DC INVERTER R410A improve your life INDOOR UNITS TABLE Hi-wall units Fan speeds Dry l/h 1,9 3 + Auto l/h 1,9 3 + Auto l/h 2,1 3 + Auto l/h 4,0 3 + Auto Sound pressure(h.m.l.) dB(A) 35-31-27 dB(A) 35-31-27 dB(A) 38-34-30 dB(A) 41-37-34 Dimension (HxWxD) mm 285x995x203 mm 285x995x203 mm 285x995x203 mm 330x1.140x228 Net weight kg 12 kg 12 kg 12 kg 21 Cassette units l/h 1,2 3 + Auto l/h 2,3 3 + Auto l/h 2,3 3 + Auto l/h 3,6 3 + Auto l/h 4,6 3 + Auto l/h 6,3 3 + Auto - dB(A) 43-39-36 dB(A) 44-39-36 dB(A) 44-39-36 dB(A) 47-45-41 dB(A) 53-50-46 dB(A) 53-50-46 - mm 273x575x575 mm 273x575x575 mm 273x575x575 mm 64x730x730 mm 338x860x860 mm30x860x860 mm 338x1150x860 mm 338x1150x860 mm 30x1150x860 kg 16 kg 18 kg 18 kg 2,5 kg 22 kg 6 kg 27 kg 27 kg 8 m3/h 1080-900-780 m3/h 1800-1560-1260 m3/h 1980-1560-1320 Ducted units l/h 1,5 3 + Auto l/h 2,3 3 + Auto l/h 2,3 3 + Auto l/h 3,5 3 + Auto l/h 4,2 3 + Auto l/h 6,6 3 + Auto dB(A) 45-43-40 dB(A) 45-43-40 dB(A) 45-43-40 dB(A) 34-30-27 dB(A) 38-33-31 dB(A) 40-37-33 mm 266x926x571 mm 266x926x200 mm 266x1132x571 mm 266x1132x571 mm 266x1132x200 mm 310x1000x630 mm 310x1480x630 mm 310x1480x630 kg 30 kg 6 kg 35 kg 35 kg 7,5 kg 32 kg 47 kg 47 m3/h 630-540-450 m3/h 720-650-580 m3/h 720-650-580 Floor/ceiling units l/h 1,3 3 + Auto l/h 2,3 3 + Auto l/h 3,3 3 + Auto dB(A) 49- dB(A) 51- dB(A) 51- - mm 680x900x190 mm 680x900x190 mm 680x900x190 kg 23,5 kg 23,5 kg 23,5 m3/h 1098-900-840 m3/h 1650-1380-1200 m3/h 1800-1560-1320 Ceiling units l/h 3,0 3 + Auto l/h 3,9 3 + Auto l/h 5,6 3 + Auto dB(A)38-36-33 dB(A) 41-38-35 dB(A) 43-40-37 mm 210x1180x680 mm 210x1595x680 mm 210x1595x680 kg 25 kg 33 kg 35 Air flowrate (h.m.l.) m3/h 720-600-420 m3/h 720-600-420 m3/h 780-660-480 m3/h 1140-1020-840 AWS36PH AWS45PH AWS56PH AWS71PH ASS36PH ASS45PH ASS56PH ASGM0918 (grille) ASS71PH (with grille) ASG0025E (grille) ASS100PH (with grille) ASS125PH (with grille) ASG3648E (grille) ADS36PH 2-way duct (200 mm each) Plenum ADS45PH ADS56PH 3-way duct (200 mm each) Plenum ADS71PH ADS100PH ADS125PH FC36PHG FC45PHG FC56PHG ACS71PH ACS100PH ACS125PH m3/h 700-600-500 m3/h 750-630-530 m3/h 750-630-530 m3/h 1140-1020-840 m3/h 1920-1680-1320 m3/h 1920-1680-1320 - m3/h 600-510-440 3 m /h 875-600-400 m3/h 875-600-400 - NB: For the indoor units capacity see the matching table. Ceiling units Floor/Ceiling units Hi-wall units w w w. a r g o c l i m a . c o m Ducted units Cassette units 71 7 PACKAGE-MULTIPACKAGE DC INVERTER improve your life w w w. a r g o c l i m a . c o m CONTROLS & ACCESSORIES 72 Infrared remote controller to be used with high-wall indoor units Standard wired remote controller with full features control, self-diagnostic and centralized programming capabilities Infrared remote controller to be used with cassette and floor/ceiling indoor units Simplified wired remote controller to be used with the full range of indoor units; it controls all the main features Infrared remote controller to be used with underceiling indoor units Remote sensor to be used with the full range of indoor units to detect the room temperature when no remote controller sensor or body sensor is used: suggested for air-conditioner systems without remote controller Infrared remote controller to be used, in matching with a special infrared receiver, with the full range of indoor units; it shows the operation status of the air-conditioner Schedule timer able to manage up to 64 indoor units with customized programming of all features, on/off cycles, etc. ER R410A - CONTROLS & ACCESSORIES improve your life DDVI16 capacity after distribution joint is 16.0 kW or less DTVP capacity after distribution joint is 28.0 kW or less w w w. a r g o c l i m a . c o m OPTIONAL DISTRIBUTION JOINT KITS (for indoor units) 73 w w w. a r g o c l i m a . c o m M U LT I S E T V. R . F. D C I N V E R T E R R 4 1 0 A improve your life MINI MULTISET V.R.F. DCI R410A AES04MMIH AES05MMIH AES06MMIH Cooling: 11,2 kW Heating: 12,5 kW Cooling: 14 kW Heating: 16 kW Cooling: 15,5 kW Heating: 17,6 kW improve your life Available during the second part of 2006 Features The Mini Multiset V.R.F. DC Inverter System is the new frontier of technologie, specifically thought for residential and light commercial applications High efficiency DC Inverter Compressor, ciruit DCI PAM (Dc Inverter Pulse Amplitude modulation), maximum of 9 indoor units connectable to 1 outdoor unit (model AES06MMIH). DC Inverter Fan DCI Variable Refrigerant Flow: continuous regulation of the refrigerant flowrate in the circuit of an air conditioning system able to give the best in term of comfort, with very high efficiency levels (E.E.R. up to 4,06 - model AES04MMIH) V.R.F. Reduced dimensions of the outdoor unit Three sizes available: 4-5-6 HP Single-phase (230/1/50) power supply R410A COMPACT WIDE RANGE 230 VOLT Refrigerant circuit of a maximum lenght of 150 m, to be realized with a big save of time thanks to the reduced pipe dimension and to the simple tree structure that makes widenings easy, not requiring any installation of expensive concentrator apparatus 150 m LAN (Local Area Network) for the interconnession of all the indoor/outdoor units and the system controls, realized with two wiring cables without polarization; the intelligent controllers are able to autoset all the units, symplifying and reducing to minimum the time-to-start LAN Low sound levels thanks to the special fans and to the careful study of the air movements in suction The wide range of outdoor air temperature supported allows the operation even in extreme conditions: - from -10°C to +43°C in cooling mode; from -20°C to +15,5°C in heating mode Indoor units, controllers (all optional) and accessories are the same as those of 2-way Multiset V.R.F.DCI SILENCE WIDE LIMITS MATCHING & CONTROLS w w w. a r g o c l i m a . c o m The most ecological and efficient refrigerant available for air conditiong systems of this level of thermal capacity 75 MINI MULTISET V.R.F. DCI R410A improve your life "Inverter" outdoor units Features Cooling/Heating capacity w w w. a r g o c l i m a . c o m E.E.R. / C.O.P. Air flowrate (h.) Sound pressure (normal/silent mode) Power supply Running consumption Compressor type Refrigerant type Liquid pipe diameter Gas pipe diameter Max. number of connectable indoor units Max. pipe lenght Gas standard charge Max. distance between indoor units Max. height between units (Outdoor on top) Max. height between units (Indoor on top) Net weight Outdoor Net dimension Outdoor (H./W./D.) 76 units HP kW BTU/h kcal/h (kW/kW) m³/h dB(A) V/Ph/Hz kW mm(inch") mm(inch") no. m Kg m m m Kg mm AES04MMIH Cooling Heating 4 11,2 12,5 38.200 42.700 9.630 10.750 4,06 4,34 6.000 51/48 230/1/50 2,76 2,88 DC Inverter R410A 9,52(3/8") 15,88(5/8") 6 150 3,5 15 50 40 104 1.200x940x340 AES05MMIH Cooling Heating 5 14,0 16,0 47.800 54.600 12.040 13.760 3,66 4,1 6.000 51/48 230/1/50 3,83 3,90 DC Inverter R410A 9,52(3/8") 15,88(5/8") 8 150 3,5 15 50 40 104 1.200x940x340 AES06MMIH Cooling Heating 6 15,5 17,6 52.900 60.000 13.330 15.140 3,39 3,84 6.000 52/49 230/1/50 4,57 4,58 DC Inverter R410A 9,52(3/8") 19,05 (3/4") 9 150 3,5 15 50 40 104 1.200x940x341 MULTISET V.R.F, DC INVERTER R410A improve your life DC Inverter Compressor + Scroll AC Compressor, the perfect matching for a high efficiency system with capacity up to 48HP, automatically modulated by the DCI PAM (Dc Inverter Pulse Amplitude modulation) circuit on a maximum of 40 indoor units connected DCI + SAC Variable Refrigerant Flow: continuous regulation of the refrigerant flowrate in the circuit of an air conditioning system able to give the best in term of comfort, with very high efficiency levels (COP up to 4,09) V.R.F. The most ecological and efficient refrigerant available for air conditiong systems of this level of thermal capacity R410A Two-way system with possibility of condensing and indoor units increase thanks to the simple tree refrigerant circuit TWO WAY New three-way solution with heat recovery, giving the possibility of a simultaneous independent operation in cooling and/or heating modes of each indoor unit THREE WAY Reduction of the total refrigerant volume of about 21% in comparison with the previous systems HFC=- 21% LAN (Local Area Network) for the interconnession of all the indoor/outdoor units and the system controls, realized with two wiring cables without polarization; the intelligent controllers are able to autoset all the units, symplifying and reducing to minimum the time-to-start 300 m LAN A special electronic system controls the operating cycles of the compressors, distributing the load and extending the efficiency in the time LONG LIFE The system is able to activate the automatic back-up of the condensing units in error or stopped; the sophisticated control system compensates the bad operation of the blocked outdoor unit, distributing the thermal power to the other outdoor units of the multiple configuration system BACK UP For the first time the sound levels are lower than 52 dB; thanks to the special fans and to the careful study of the air movements in suction, the sound levels have been reduced of more than 4 dB in comparison with the previous models SILENCE The wide range of outdoor air temperature supported allows the operation even in extreme conditions: Two-way Systems: from -5°C to +43°C in cooling mode ; from -20°C to +15,5°C in heating mode Three-way Systems: from -10°C to +43°C in cooling mode ; from -20°C to +15,5°C in heating mode The condensing units in multiple configuration can be installed at a distance of only 10 cm or very far one from the other, even on different stages of the building; this feature makes the system more adaptable to the various circumstances SOLENOID VALVE KIT WIDE RANGE FREE PLACE w w w. a r g o c l i m a . c o m Refrigerant circuit of a maximum lenght of 300 m, to be realized with a big save of time thanks to the reduced pipe dimension and to the simple tree structure that makes widenings easy, not requiring any installation of expensive concentrator apparatus 77 Three way system sample with heat recover. Simultaneous independent operation in cooling and/or heating modes of each indoor unit. 7 MULTISET V.R.F, DC INVERTER R410A 2 WAY DC INVERTER O.U. 2 WAY C.S. O.U. 3 WAY DC INVERTER O.U. improve your life SYSTEM CONFIGURATION w w w. a r g o c l i m a . c o m MULTISET V.R.F. DC INVERTER R410A - TWO-WAY SYSTEM CAPACITY TABLE Cooling (kW) Total capacity Power input Capacity class in heating Max. connectable I.U. O.U. n° 1 DC Inverter O.U. n° 2 Constant Speed O.U. n° 3 Constant Speed O.U. n° 4 Constant Speed 2-way Circuit 2-way Circuit 2-way Circuit 2-way Circuit 1+2+3+4 kW 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 9 13 16 19 23 26 29 33 36 40 40 40 40 40 40 40 40 40 40 40 40 40 AES06MI2H AES08MI2H AES10MI2H AES12MI2H AES06MI2H AES08MI2H AES10MI2H AES10MI2H AES12MI2H AES12MI2H AES10MI2H AES10MI2H AES10MI2H AES12MI2H AES12MI2H AES12MI2H AES10MI2H AES10MI2H AES12MI2H AES12MI2H AES12MI2H AES12MI2H AES08M2H AES08M2H AES08M2H AES10M2H AES10M2H AES12M2H AES08M2H AES10M2H AES10M2H AES10M2H AES12M2H AES12M2H AES10M2H AES10M2H AES10M2H AES12M2H AES12M2H AES12M2H AES08M2H AES08M2H AES10M2H AES10M2H AES10M2H AES12M2H AES10M2H AES10M2H AES10M2H AES10M2H AES12M2H AES12M2H AES08M2H AES10M2H AES10M2H AES10M2H AES10M2H AES12M2H 16,0 22,4 28,0 33,5 40,0 45,0 50,4 56,0 61,5 68,0 73,0 78,5 85,0 90,0 96,0 101,0 106,5 113,0 118,0 123,5 130,0 135,0 4,6 6,7 8,7 10,9 12,5 13,9 15,9 17,9 20,2 22,7 23,2 25,1 27,6 29,6 31,9 33,8 34,4 36,8 38,8 40,9 43,5 45,3 Capacity class in heating 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 Max. connectable I.U. 13 16 19 23 26 29 33 36 40 40 40 40 40 40 40 40 40 40 40 40 40 E.E.R. 3,51 3,34 3,21 3,07 3,20 3,24 3,17 3,13 3,04 3,00 3,15 3,13 3,08 3,04 3,01 2,99 3,10 3,07 3,04 3,02 2,99 2,98 Heating (kW) Total capacity Power input 1+2+3+4 kW 18,0 25,0 31,5 37,5 45,0 50,0 56,5 63,0 69,0 76,5 81,5 88,0 95,0 100,5 108,0 113,0 119,5 126,5 132,0 138,0 145,0 150,0 4,8 6,9 8,9 11,4 12,9 14,1 16,1 18,3 20,7 23,6 23,3 25,5 27,9 30,1 33,0 34,7 34,9 37,4 39,5 41,7 44,3 46,2 3,75 3,65 3,53 3,29 3,49 3,55 3,51 3,44 3,33 3,24 3,50 3,45 3,41 3,34 3,27 3,26 3,42 3,38 3,34 3,31 3,27 3,25 MULTISET V.R.F. DC INVERTER R410A - THREE-WAY SYSTEM CAPACITY TABLE WITH HEAT RECOVERY O.U. n° 1 DC Inverter 3-way Circuit AES08MI3H AES10MI3H AES12MI3H AES14MI3H AES16MI3H AES08MI3H AES10MI3H AES10MI3H AES12MI3H AES10MI3H AES12MI3H AES14MI3H AES16MI3H AES10MI3H AES10MI3H AES10MI3H AES10MI3H AES10MI3H AES12MI3H AES14MI3H AES16MI3H O.U. n° 2 DC Inverter 3-way Circuit AES10MI3H AES10MI3H AES12MI3H AES12MI3H AES16MI3H AES16MI3H AES16MI3H AES16MI3H AES10MI3H AES10MI3H AES12MI3H AES14MI3H AES16MI3H AES16MI3H AES16MI3H AES16MI3H O.U. n° 3 DC Inverter 3-way Circuit AES14MI3H AES16MI3H AES16MI3H AES16MI3H AES16MI3H AES16MI3H AES16MI3H AES16MI3H O.U. n° 4 DC Inverter 3-way Circuit - Cooling (kW) Total capacity Power input E.E.R. 1+2+3+4 kW 22,4 5,93 3,78 28,0 8,12 3,45 33,5 9,82 3,41 40,0 11,6 3,45 45,0 13,3 3,38 50,4 14,1 3,57 56,0 16,2 3,46 61,5 17,9 3,44 68,0 19,7 3,45 73,0 21,4 3,41 78,5 23,1 3,40 85,0 24,9 3,41 90,0 26,6 3,38 96,0 27,8 3,45 101,0 29,6 3,41 107,0 31,3 3,42 113,0 33,0 3,42 118,0 34,7 3,40 124,0 36,4 3,41 130,0 38,2 3,40 135,0 39,9 3,38 Heating (kW) Total capacity Power input C.O.P. 1+2+3+4 kW 25,0 6,11 4,09 31,5 7,97 3,95 37,5 9,84 3,81 45,0 11,5 3,91 50,0 13,2 3,79 56,5 14,1 4,01 63,0 15,9 3,96 69,0 17,8 3,88 76,5 19,5 3,92 81,5 21,2 3,84 87,5 23,0 3,80 95,0 24,7 3,85 100,0 26,4 3,79 108,0 27,5 3,93 113,0 29,1 3,88 119,0 31,0 3,84 127,0 32,7 3,88 132,0 34,4 3,84 138,0 36,2 3,81 145,0 37,9 3,83 150,0 39,6 3,79 refrigerant circuit up to 300 meters with three structure easy to upgrade up to 48 HP simply adding outdoor units easy to upgrade up to 48 HP simply adding outdoor units refrigerant circuit up to 300 meters with three structure indoor units upgrade is very easy 78 C.O.P. indoor units upgrade is very easy MULTISET V.R.F, DC INVERTER R410A HI-WALL DUCTED FLOOR/CEILING 22/28/36/56/73 22/28/36/45/56/64 73/106/140 22/28/36/45/56/64 CASSETTE CEILING SLIM DUCTED 22/28/36/45/56/73 106/140 73/106/140 22/28/36/45/56/64 improve your life AWS22MH AWS28MH AWS36MH AWS56MH AWS73MH ASS22MH ASS28MH ASS36MH ASS45MH ASS56MH ASGM0918 (grille) ASS73MH (with grille) ASG0025E (grille) ASS106MH (with grille) ASS140MH (with grille) ASG3648E (grille) ADS22MH ADS28MH ADS36MH 2-way duct (200 mm each) Plenum AD45MHG ADS56MH AD64MHG 3-way duct (200 mm each) Plenum ADS73MH ADS106MH ADS140MH FC22MHG FC28MHG FC36MHG FC45MHG FC56MHG FC64MHG ACS73MH ACS106MH ACS140MH SD22MHG SD28MHG SD36MHG SD45MHG SD56MHG SD64MHG Air flowrate (h.m.l.) m3/h 600-480-360 m3/h 600-480-360 m3/h 600-480-360 m3/h 720-600-480 m3/h 960-840-600 Hi-wall units Fan speeds Dry l/h 1,3 3 + Auto l/h 1,6 3 + Auto l/h 2,0 3 + Auto l/h 2,3 3 + Auto l/h 4,0 3 + Auto Sound pressure(h.m.l.) dB(A) 36-32-28 dB(A) 36-32-28 dB(A) 36-32-28 dB(A) 36-32-28 dB(A) 42-38-35 Dimension (HxWxD) mm 285x995x203 mm 285x995x203 mm 285x995x203 mm 285x995x203 mm 330x1.140x228 Net weight kg 14 kg 14 kg 14 kg 14 kg 21 Cassette units 0,9 3 + Auto 1,0 3 + Auto 1,2 3 + Auto 2,3 3 + Auto 2,3 3 + Auto l/h 3,6 3 + Auto l/h 4,6 3 + Auto l/h 6,3 3 + Auto - dB(A) dB(A) dB(A) dB(A) dB(A) 43-39-36 43-39-36 43-39-36 44-39-36 44-39-36 dB(A) 47-45-41 dB(A) 53-50-46 dB(A) 53-50-46 - mm 273x575x575 mm 273x575x575 mm 273x575x575 mm 273x575x575 mm 273x575x575 mm 64x730x730 mm 338x860x860 mm30x860x860 mm 338x1150x860 mm 338x1150x860 mm 30x1150x860 kg 16 kg 16 kg 16 kg 18 kg 18 kg 2,5 kg 22 kg 6 kg 27 kg 27 kg 8 m3/h 1080-900-780 m3/h 1800-1560-1260 m3/h 1980-1560-1320 Ducted units l/h 0,8 3 + Auto l/h 0,8 3 + Auto l/h 1,5 3 + Auto l/h 2,3 3 + Auto l/h 2,3 3 + Auto l/h 2,6 3 + Auto l/h 3,5 3 + Auto l/h 4,2 3 + Auto l/h 6,6 3 + Auto dB(A) 45-43-40 dB(A) 45-43-40 dB(A) 45-43-40 dB(A) 45-43-40 dB(A) 45-43-40 dB(A) 48-46-43 dB(A) 34-30-27 dB(A) 38-33-31 dB(A) 40-37-33 mm 266x926x571 mm 266x926x571 mm 266x926x571 mm 266x926x200 mm 266x1132x571 mm 266x1132x571 mm 266x1132x571 mm 266x1132x200 mm 310x1000x630 mm 310x1480x630 mm 310x1480x630 kg 30 kg 30 kg 30 kg 6 kg 35 kg 35 kg 35 kg 7,5 kg 32 kg 47 kg 47 m3/h 630-540-450 m3/h 630-540-450 m3/h 630-540-450 m3/h 720-650-580 m3/h 720-650-580 m3/h900-- Floor/ceiling units l/h 1,0 3 + Auto l/h 1,2 3 + Auto l/h 1,3 3 + Auto l/h 2,3 3 + Auto l/h 2,3 3 + Auto l/h 3,3 3 + Auto dB(A) 49-43-38 dB(A) 49-43-38 dB(A) 49-43-38 dB(A) 51- 47-43 dB(A) 51- 47-43 dB(A) 52- 49-46 m3/h 1098-900-840 m3/h 1650-1380-1200 m3/h 1800-1560-1320 Ceiling units l/h 3,0 3 + Auto l/h 3,9 3 + Auto l/h 5,6 3 + Auto dB(A)38-36-33 dB(A) 41-38-35 dB(A) 43-40-37 Slim ducted units l/h 1,0 3 + Auto l/h 1,2 3 + Auto l/h 1,3 3 + Auto l/h 2,3 3 + Auto l/h 2,3 3 + Auto l/h 3,3 3 + Auto dB(A) dB(A) dB(A) dB(A) dB(A) dB(A) m3/h m3/h m3/h m3/h m3/h 700-600-500 700-600-500 700-600-500 750-630-530 750-630-530 - m3/h 1140-1020-840 m3/h 1920-1680-1320 m3/h 1920-1680-1320 - m3/h 600-510-440 m3/h 600-510-440 m3/h 600-510-440 m3/h 875-600-400 m3/h 875-600-400 m3/h 1000-700-600 - m3/h m3/h m3/h m3/h m3/h m3/h 470-380-340 470-380-340 470-380-340 620-540-450 620-540-451 680-600-520 l/h l/h l/h l/h l/h 37-30-26 37-30-26 37-30-26 45-41-33 45-41-33 49-45-40 mm mm mm mm mm mm 680x900x190 680x900x190 680x900x190 680x900x190 680x900x190 680x900x190 mm 210x1180x680 mm 210x1595x680 mm 210x1595x680 mm mm mm mm mm mm 585x890x190 585x890x190 585x890x190 585x890x190 585x890x190 585x890x190 kg kg kg kg kg kg 23,5 23,5 23,5 23,5 23,5 23,5 kg 25 kg 33 kg 33 kg kg kg kg kg kg 25 25 25 25 25 25 w w w. a r g o c l i m a . c o m INDOOR UNITS FOR MINI & MULTISET SYSTEMS 79 MULTISET V.R.F, DC INVERTER R410A improve your life Primary outdoor units - Inverter 2-way systems Features DC Inverter outdoor units for two-way Multiset V.R.F. systems To be installed as primary units and to be matched with secondary Constant-Speed units R410A HFC refrigerant Twin Rotary DC Inverter compressor, highly efficient at low rotation frequencies Fan with direct current motor that allows a consumption reduction of about 50% and a speed modulation up to 16 steps in spite of the usual 4 steps of the alternate current motors; this performance increases the efficiency of the thermodynamic system which is able to best adapt to the variations of temperature and thermal load of the rooms The use of a special oil sensor allows, for the first time in the world, to keep under control the lubrification of the mechanical parts of the compressor w w w. a r g o c l i m a . c o m Special air intakes and Double Chamber construction technology allowed to unify the dimensions of the units, making easier the closing up for multiple installatios in which two units can be placed at a distance of only 10 cm one from the other, the smaller distance available A special fan made of resin allows to reduce the sound level of the outdoor units (all models except only for AES06MI2H9) 80 Three-phase autosense power supply 380-415/3N/50Hz A special resin grille has been designed and used for these units in order to minimize air pressure drops and consequently reduce the outdoor sound level of 4 dB New high efficiency Cross-Arranged heat exchanger with three-way suction, divided in two sections with double control of defronsting cycle Pressure control automatic and by software on PC Pipe connession inside the unit frame through a special space to be closed back when the installation is finished Equipped with Fault-Tolerant system granting in multiple installations the operation of the air conditioning system also in case of total stop of one condensing unit Support to Long-Life system that, in multiple installations, allows a cyclic use of the condensing units, granting a balance of the compressors activity Wide range of outdoor air temperature: from -5°C to +43°C in cooling mode and from -20°C to +15,5°C in heating mode Maximum lenght of the refrigerant circuit extended to 300 m The refrigerant circuit doesn't require distribution apparatus downstream of the unit as it can be realized with a tree structure using only the special distributor accessories; this feature facilitates any type of system widening, by adding both outdoor and indoor units MULTISET V.R.F, DC INVERTER R410A improve your life Primary outdoor units "Inverter" Features Cooling/Heating capacity E.E.R. / C.O.P. Air flowrate (h.) Sound pressure (normal/silent mode) Power supply Running consumption Compressor type Refrigerant type Liquid pipe diameter Gas pipe diameter Max. pipe lenght Gas standard charge Gas additional charge Max. height between units (Outdoor on top) Max. height between units (Indoor on top) Net weight Outdoor Net dimension Outdoor (H./W./D.) Primary outdoor units "Inverter" Features Cooling/Heating capacity E.E.R. / C.O.P. Air flowrate (h.) Sound pressure (normal/silent mode) Power supply Running consumption Compressor type Refrigerant type Liquid pipe diameter Gas pipe diameter Max. pipe lenght Gas standard charge Gas additional charge Max. height between units (Outdoor on top) Max. height between units (Indoor on top) Net weight Outdoor Net dimension Outdoor (H./W./D.) units kW BTU/h kcal/h (kW/kW) m³/h dB(A) V/Ph/Hz kW mm(inch") mm(inch") m Kg gr/m m m Kg mm units kW BTU/h kcal/h (kW/kW) m³/h dB(A) V/Ph/Hz kW mm(inch") mm(inch") m Kg gr/m m m Kg mm AES06MI2H Cooling Heating 16,00 18,00 54.600 61.400 13.760 15.480 3,51 3,75 4.800 53/48 400/3N/50 4,6 4,8 Twin Rotary DC Inverter R410A 9,52(3/8") 19,05(3/4") 300 7,5 56 50 40 198 1.580x750(+73)x890 AES08MI2H Cooling Heating 22,40 25,00 76.400 85.300 19.270 21.500 3,34 3,65 9.000 55/50 400/3N/50 6,7 6,9 Twin Rotary DC Inv.+Scroll CS R410A 9,52(3/8") 19,05(3/4") 300 10 56 50 40 278 1.580x890(+75)x890 AES10MI2H Cooling Heating 28,00 31,50 95.500 107.500 24.080 27.090 3,21 3,53 9.000 55/50 400/3N/50 8,7 8,9 Twin Rotary DC I + Scroll CS R410A 9,52(3/8") 22,22(7/8") 300 10 56 50 40 280 1.580x890(+75)x890 AES12MI2H Cooling Heating 33,50 37,50 114.300 128.000 28.810 32.250 3,07 3,29 9.000 56/51 400/3N/50 10,9 11,4 Twin Rotary DC I + Scroll CS R410A 12,70(1/2") 25,40(1") 300 10 128 50 40 280 1.580x890(+75)x890 w w w. a r g o c l i m a . c o m Technical data 81 MULTISET V.R.F, DC INVERTER R410A improve your life Secondary outdoor units “Constant speed” 2-way systems Features Constant-Speed outdoor units for two-way Multiset V.R.F. systems To be installed as secondary units and to be matched with primary DC Inverter units R410A HFC refrigerant High efficiency Scroll compressor Fan with direct current motor that allows a consumption reduction of about 50% and a speed modulation up to 16 steps in spite of the usual 4 steps of the alternate current motors; this performance increases the efficiency of the thermodynamic system which is able to best adapt to the variations of temperature and thermal load of the rooms The use of a special oil sensor allows, for the first time in the world, to keep under control the lubrification of the mechanical parts of the compressor Special air intakes and Double Chamber construction technology allowed to unify the dimensions of the units, making easier the closing up for multiple installatios in which two units can be placed at a distance of only 10 cm one from the other, the smaller distance available w w w. a r g o c l i m a . c o m A special fan made of resin allows to reduce the sound level of the outdoor units A special resin grille has been designed and used for these units in order to minimize air pressure drops and consequently reduce the outdoor sound level of 4 dB New high efficiency Cross-Arranged heat exchanger with three-way suction, divided in two sections with double control of defronsting cycle Pressure control automatic and by software on PC Pipe connession inside the unit frame through a special space to be closed back when the installation is finished Equipped with Fault-Tolerant system granting in multiple installations the operation of the air conditioning system also in case of total stop of one condensing unit Support to Long-Life system that, in multiple installations, allows a cyclic use of the condensing units, granting a balance of the compressors activity Wide range of outdoor air temperature: from +5°C to +43°C in cooling mode and from -20°C to +15,5°C in heating mode Maximum lenght of the refrigerant circuit extended to 300 m The refrigerant circuit doesn't require distribution apparatus downstream of the unit as it can be realized with a tree structure using only the special distributor accessories; this feature facilitates any type of system widening, by adding both outdoor and indoor units Three-phase autosense power supply 380-415/3N/50Hz 82 MULTISET V.R.F, DC INVERTER R410A improve your life Technical data Cooling/Heating capacity E.E.R. / C.O.P. Air flowrate (h.) Sound pressure (normal/silent mode) Power supply Running consumption Compressor type Refrigerant type Liquid pipe diameter Gas pipe diameter Max. pipe lenght Gas standard charge Gas additional charge Max. height between units (Outdoor on top) Max. height between units (Indoor on top) Net weight Outdoor Net dimension Outdoor (H./W./D.) Secondary outdoor units "Constant Speed" Features Cooling/Heating capacity E.E.R. / C.O.P. Air flowrate (h.) Sound pressure (normal/silent mode) Power supply Running consumption Compressor type Refrigerant type Liquid pipe diameter Gas pipe diameter Max. pipe lenght Gas standard charge Gas additional charge Max. height between units (Outdoor on top) Max. height between units (Indoor on top) Net weight Outdoor Net dimension Outdoor (H./W./D.) Secondary outdoor units "Constant Speed" Features Cooling/Heating capacity E.E.R. / C.O.P. Air flowrate (h.) Sound pressure (normal/silent mode) Power supply Running consumption Compressor type Refrigerant type Liquid pipe diameter Gas pipe diameter Max. pipe lenght Gas standard charge Gas additional charge Max. height between units (Outdoor on top) Max. height between units (Indoor on top) Net weight Outdoor Net dimension Outdoor (H./W./D.) AES08M2H Units kW BTU/h kcal/h (kW/kW) m³/h dB(A) V/Ph/Hz kW Cooling 22,40 76.400 19.270 3,11 7,2 mm(inch") mm(inch") m Kg gr/m m m Kg mm 9.000 54,5/49,5 400/3N/50 Heating 25,00 85.300 21.500 3,47 Scroll CS R410A 9,52(3/8") 19,05(3/4") 300 10 56 50 40 276 1.580x890(+75)x890 7,2 AES10M2H Units kW BTU/h kcal/h (kW/kW) m³/h dB(A) V/Ph/Hz kW Cooling 28,00 95.500 24.080 3,03 9,2 mm(inch") mm(inch") m Kg gr/m m m Kg mm 9.000 55/50 400/3N/50 Heating 31,50 107.500 27.090 3,35 Scroll CS R410A 9,52(3/8") 22,22(7/8") 300 10 56 50 40 280 1.580x890(+75)x890 9,4 AES12M2H Units kW BTU/h kcal/h (kW/kW) m³/h dB(A) V/Ph/Hz kW mm(inch") mm(inch") m Kg gr/m m m Kg mm Cooling 33,50 114.300 28.810 2,96 11,3 9.000 55,5/50,5 400/3N/50 Heating 37,50 128.000 32.250 3,23 Scroll CS R410A 12,70(1/2") 25,40(1") 300 10 128 50 40 276 1.580x890(+75)x890 11,6 w w w. a r g o c l i m a . c o m Secondary outdoor units "Constant Speed" Features 83 MULTISET V.R.F, DC INVERTER R410A improve your life Outdoor units - Inverter with heat recovery units 3-way systems Features DC Inverter outdoor units for three-way Multiset V.R.F. systems Automatic change-ober between cooling and heating modes for each indoor unit; this feature, based on the three-way technology with heat recovery, allows a fully independent operation of each indoor unit R410A HFC refrigerant Twin Rotary DC Inverter compressor, highly efficient at low rotation frequencies, matching with a Scroll Constant-Speed compressor Fan with direct current motor that allows a consumption reduction of about 50% and a speed modulation up to 16 steps in spite of the usual 4 steps of the alternate current motors; this performance increases the efficiency of the thermodynamic system which is able to best adapt to the variations of temperature and thermal load of the rooms The use of a special oil sensor allows, for the first time in the world, to keep under control the lubrification of the mechanical parts of the compressor Special air intakes and Double Chamber construction technology allowed to unify the dimensions of the units, making easy the closing up for multiple installatios in which two units can be placed at a distance of only 10 cm one from the other, the smaller distance available w w w. a r g o c l i m a . c o m Low sound level thanks to a special fan made of resin and a particular resin grille, designed and used for these units in order to minimize air pressure drops 84 A special resin grille has been designed and used for these units in order to minimize air pressure drops and consequently reduce the outdoor sound level of 4 dB New high efficiency Cross-Arranged heat exchanger with three-way suction, divided in two sections with double control of defronsting cycle Pressure control automatic and by software on PC Pipe connession inside the unit frame through a special space to be closed back when the installation is finished Equipped with Fault-Tolerant system granting in multiple installations the operation of the air conditioning system also in case of total stop of one condensing unit Support to Long-Life system that, in multiple installations, allows a cyclic use of the condensing units, granting a balance of the compressors activity "On Demand" feature allows to best use the caracteristics of DC Inverter technology, setting three different levels of electric power on which are automatically based the control microprocessors so that to achieve the maximum performances with reduction of electric consumption Extra range of outdoor air temperature: from -10°C to +43°C in cooling mode and from -20°C to +15,5°C in heating mode Maximum lenght of the refrigerant circuit extended to 300 m The refrigerant circuit doesn't require distribution apparatus downstream of the unit as it can be realized with a tree structure using only the special distributor accessories; this feature facilitates any type of system widening, by adding both outdoor and indoor units Three-phase autosense power supply 380-415/3N/50Hz MULTISET V.R.F, DC INVERTER R410A improve your life Technical data Cooling/Heating capacity E.E.R. / C.O.P. Air flowrate (h.) Sound pressure (normal/silent mode) Power supply Running consumption Compressor type Refrigerant type Liquid pipe diameter Gas pipe diameter (suction) Gas pipe diameter (discharge) Max. pipe lenght Gas standard charge Gas additional charge Max. height between units (Outdoor on top) Max. height between units (Indoor on top) Net weight Outdoor Net dimension Outdoor (H./W./D.) 3-way outdoor units "Inverter" Features Cooling/Heating capacity E.E.R. / C.O.P. Air flowrate (h.) Sound pressure (normal/silent mode) Power supply Running consumption Compressor type Refrigerant type Liquid pipe diameter Gas pipe diameter (suction) Gas pipe diameter (discharge) Max. pipe lenght Gas standard charge Gas additional charge Max. height between units (Outdoor on top) Max. height between units (Indoor on top) Net weight Outdoor Net dimension Outdoor (H./W./D.) Units kW BTU/h kcal/h (kW/kW) m³/h dB(A) V/Ph/Hz kW mm(inch") mm(inch") mm(inch") m Kg gr/m m m Kg mm Units kW BTU/h kcal/h (kW/kW) m³/h dB(A) V/Ph/Hz kW mm(inch") mm(inch") mm(inch") m Kg gr/m m m Kg mm AES08MI3H Cooling Heating 22,40 25,00 76.400 85.300 19.270 21.500 3,78 4,09 9.000 54,5/51,5 400/3N/50 5,93 6,11 Twin Rotary DCI+Scroll CS R410A 9,52(3/8") 19,05(3/4") 15,88(5/8") 300 12 56 50 40 290 1.887x890x890(+60) AES10MI3H Cooling Heating 28,00 31,50 95.500 107.500 24.080 27.090 3,45 3,95 9.600 55/52 400/3N/50 8,12 7,97 Twin Rotary DCI+Scroll CS R410A 9,52(3/8") 22,22(7/8") 19,05(3/4") 300 12 56 50 40 290 1.887x890x890(+60) AES14MI3H Cooling Heating 40,00 45,00 136.500 153.600 34.400 38.700 3,45 3,91 12.000 60/57 400/3N/50 11,6 11,5 Twin Rotary DC I+Scroll CS R410A 12,70(1/2") 25,40(1") 22,22(7/8") 300 15 128 50 40 350 1.887x890x890(+60) AES16MI3H Cooling Heating 45,00 50,00 153.600 170.600 38.700 43.000 3,38 3,79 13.200 61/58 400/3N/50 13,3 13,2 Twin Rotary DC I+Scroll CS R410A 12,70(1/2") 28,58(1-1/8") 22,22(7/8") 300 15 128 50 40 350 1.887x890x890(+60) AES12MI3H Cooling Heating 33,50 37,50 114.300 128.000 28.810 32.250 3,41 3,81 10.800 56/53 400/3N/50 9,82 9,84 Twin Rotary DCI + Scroll CS R410A 12,70(1/2") 25,40(1") 19,05(3/4") 300 12 128 50 40 290 1.887x890x890(+60) w w w. a r g o c l i m a . c o m 3-way outdoor units "Inverter" Features 85 MULTISET V.R.F, DC INVERTER R410A improve your life CONTROL SYSTEM DIMENSIONS w w w. a r g o c l i m a . c o m 16 86 PLC INTERFACE MULTISET V.R.F, DC INVERTER R410A OPTIONAL DISTRIBUTION JOINT KITS FOR 2-WAY SYSTEMS improve your life (for indoor units) (less than 16.0 kW) (for indoor units) (from 16.0 kW to 68.0 kW after joint kit ) (for outdoor units) (less than 68.0 kW after joint kit) (for outdoor units) (from 68.0 kW to 135.0 kW after joint kit) LEGENDA: F letter in circle = female side - F letter not in circle = male side (for indoor units) (from 68.0 kW to 135.0 kW after joint kit) w w w. a r g o c l i m a . c o m DDVI68 87 MULTISET V.R.F, DC INVERTER R410A improve your life SOLENOID VALVE KIT FOR 3-WAY SYSTEMS Solenoid valve kit M3 EVV 22-556 (for 22-56 types of indoor units) It is possible to connect 1 only solenoid valve kit controlling a group of indoor units, with a total capacity up to 5,6 kW. All the indoor units of the group will operate in the same mode (cooling or heating) M3 EVV 73-1140 (for 73-140 types of indoor units) It is possible to connect 1 only solenoid valve kit controlling a group of indoor units, with a total capacity up to 14 kW. All the indoor units of the group will operate in the same mode (cooling or heating) In case 1 only solenoid valve kit is used to control a group of indoor units, only 1 control must be used for the whole group. M3 EVV C w w w. a r g o c l i m a . c o m Solenoid valve controller 88 MULTISET V.R.F, DC INVERTER R410A OPTIONAL DISTRIBUTION JOINT KITS FOR 3-WAY SYSTEMS p p g, improve your life , ( Position Part A Part B Part C Part D Part E Part F Part G Part H Part I Part J Dimension ø38.1 ø31.75 ø28.58 ø25.4 ø22.22 ø19.05 ø15.88 ø12.7 ø9.52 ø6.35 ) M3DDV22 (for indoor units) (Capacity after distribution joint is 22.4 kW or less.) Discharge pipe 210 G H GH 55 235 H H 40 H 92 145 I H I H G 55 G H G H H F F 7 F HI 77 F 12 F G F Liquid pipe 186 69 Suction pipe 136 Insulator Insulator Insulator M3DDV68 (for indoor units) (Capacity after distribution joint is greater than 22.4 kW and no more than 68.0 kW)) Discharge pipe 300 C 112 74 G H 230 EFG G GF E HI 340 E F F 55 230 G G F E I H D F G 16 D C D E F I H G 126 126 112 D D EF FED C C 50 55 DE F 16 C C FED C C Liquid pipe 300 130 Suction pipe Insulator Insulator Insulator M3DDV135 (for indoor units) (Capacity after distribution joint is greater than 68.0 kW and no more than 135.0 kW)) 55 I H G Liquid pipe F E D F G F E C G C A F E D C C A B BA B 90 45 B B EFG GF E I H B G HI 50 340 C CDE F 105 130 H G Suction pipe Discharge pipe 112 Insulator Insulator Discharge pipe 490 C DE F 112 ED C C D D C D D EFG 101 83 D C D D E F E F G 230 Insulator G G F E GF E E FG G HI I H 126 C 126 C C 230 I H G 300 300 C Liquid pipe 490 130 Suction pipe 50 340 Insulator Insulator M3DDVE135 (for outdoor units) (Capacity after distribution joint is greater than 68.0 kW and no more than 135.0 kW)) Discharge pipe Liquid pipe 615 490 375 B B A C C DE F 105 112 C C D C C C DE F G I H G G F E EFG G GFE I H HI 340 C B 315 C 112 B C D C 53 126 B 180 B B A 112 300 B A 230 D E F 50 130 Suction pipe w w w. a r g o c l i m a . c o m M3DDVE68 (for outdoor units) (Capacity after distribution joint is 68.0 kW or less.) 66 Insulator Insulator LEGENDA: F letter in circle = female side - F letter not in circle = male side Insulator 89 MULTISET V.R.F, DC INVERTER R410A improve your life V.R.F. Indoor Units AWS 22-28-36-56-73 Features High wall indoor unit for Multiset V.R.F. DC Inverter systems Automatic change-over between cooling and heating modes Special function during heat pump start-up and defrosting cycle to avoid cool air emission in the room Night set back capability To be managed by the wired and wireless controllers of the Multiset V.R.F. DC Inverter systems (optional) "I Feel" feature and temperature sensor inside the remote control w w w. a r g o c l i m a . c o m Dry function 90 New three-speed tangential fan by remote control, granting a better and low noise air diffusion Horizontal flap swinging or to be set to a fixed position by remote control Vertical flap by manual control Anti-mould and anti-bacteria washable filter Three-way condensate discharge (right, central and left) Dynamic refrigerant control by DC Inverter compressor and circuit, electronic valve and fuzzy logic managed by a powerful microprocessor MULTISET V.R.F, DC INVERTER R410A improve your life PRODUCT NAME Features Cooling/Heating capacity Air flowrate Indoor (h.m.l.) Dehumidification Fan speeds Sound pressure Indoor (h.m.l.) Power supply Running consumption Refrigerant type Liquid pipe diameter Gas pipe diameter Net weight Indoor Net dimension Indoor (H./W./D.) PRODUCT NAME Features Cooling/Heating capacity Air flowrate Indoor (h.m.l.) Dehumidification Fan speeds Sound pressure Indoor (h.m.l.) Power supply Running consumption Refrigerant type Liquid pipe diameter Gas pipe diameter Net weight Indoor Net dimension Indoor (H./W./D.) PRODUCT NAME Features Cooling/Heating capacity Air flowrate Indoor (h.m.l.) Dehumidification Fan speeds Sound pressure Indoor (h.m.l.) Power supply Running consumption Refrigerant type Liquid pipe diameter Gas pipe diameter Net weight Indoor Net dimension Indoor (H./W./D.) PRODUCT NAME Features Cooling/Heating capacity Air flowrate Indoor (h.m.l.) Dehumidification Fan speeds Sound pressure Indoor (h.m.l.) Power supply Running consumption Refrigerant type Liquid pipe diameter Gas pipe diameter Net weight Indoor Net dimension Indoor (H./W./D.) PRODUCT NAME Features Cooling/Heating capacity Air flowrate Indoor (h.m.l.) Dehumidification Fan speeds Sound pressure Indoor (h.m.l.) Power supply Running consumption Refrigerant type Liquid pipe diameter Gas pipe diameter Net weight Indoor Net dimension Indoor (H./W./D.) Units kW BTU/h kcal/h m3/h l/h n° dB(A) V/Ph/Hz kW mm(inch") mm(inch") Kg mm Units kW BTU/h kcal/h m3/h l/h n° dB(A) V/Ph/Hz kW mm(inch") mm(inch") Kg mm Units kW BTU/h kcal/h m3/h l/h n° dB(A) V/Ph/Hz kW mm(inch") mm(inch") Kg mm Units kW BTU/h kcal/h m3/h l/h n° dB(A) V/Ph/Hz kW mm(inch") mm(inch") Kg mm Units kW BTU/h kcal/h m3/h l/h n° dB(A) V/Ph/Hz kW mm(inch") mm(inch") Kg mm AWS22MH Cooling Heating 2,20 2,50 7.500 8.520 1.890 2.150 600-480-360 1,3 3 + Auto 36-32-28 230/1/50 0,033 0,033 R410A 6,35(1/4") 12,70(1/2") 14 285x995x203 AWS28MH Cooling Heating 2,80 3,20 9.550 10.920 2.410 2.750 600-480-360 1,6 3 + Auto 36-32-28 230/1/50 0,033 0,033 R410A 6,35(1/4") 12,70(1/2") 14 285x995x203 AWS36MH Cooling Heating 3,60 4,20 12.280 14.320 3.100 3.610 600-480-360 2,0 3 + Auto 36-32-28 230/1/50 0,033 0,033 R410A 6,35(1/4") 12,70(1/2") 14 285x995x203 AWS56MH Cooling Heating 5,60 6,30 19.100 21.480 4.820 5.420 720-600-480 2,3 3 + Auto 36-32-28 230/1/50 0,033 0,033 R410A 6,35(1/4") 12,70(1/2") 14 285x995x203 AWS73MH Cooling Heating 7,30 8,00 24.890 27.280 6.280 6.880 960-840-600 4,0 3 + Auto 42-38-35 230/1/50 0,052 0,052 R410A 9,52(3/8") 15,88(5/8") 21 330x1.140x228 w w w. a r g o c l i m a . c o m Technical data 91 MULTISET V.R.F, DC INVERTER R410A improve your life V.R.F. Indoor Units ASS 22-28-36-45-56 Features Four-way cassette indoor unit to be matched with Multiset V.R.F. DC Inverter systems Automatic change-over between cooling and heating modes Special function during heat pump start-up and defrosting cycle to avoid cool air emission in the room Night set back capability To be managed by the wired and wireless controllers of the Multiset V.R.F. DC Inverter systems (optional) "I Feel" feature and temperature sensor inside the remote control w w w. a r g o c l i m a . c o m Dry function 92 New three-speed centrifugal fan by remote control, granting a better and low noise air diffusion Horizontal flaps swinging or to be set on a fixed position by remote control Anti-mould and anti-bacteria washable filter Integrated pump for condensate discharge Possibility to have a connection for fresh air intake Double-way of air duct in adjacent rooms through pre-drilled holes Dynamic refrigerant control by DC Inverter compressor and circuit, electronic valve and fuzzy logic managed by a powerful microprocessor MULTISET V.R.F, DC INVERTER R410A improve your life PRODUCT NAME Features Cooling/Heating capacity Air flowrate Indoor (h.m.l.) Dehumidification Fan speeds Sound pressure Indoor (h.m.l.) Power supply Running consumption Refrigerant type Liquid pipe diameter Gas pipe diameter Net weight Indoor / grille Net dimension Indoor (H./W./D.) Net dimension grille (H./W./D.) PRODUCT NAME Features Cooling/Heating capacity Air flowrate Indoor (h.m.l.) Dehumidification Fan speeds Sound pressure Indoor (h.m.l.) Power supply Running consumption Refrigerant type Liquid pipe diameter Gas pipe diameter Net weight Indoor / grille Net dimension Indoor (H./W./D.) Net dimension grille (H./W./D.) PRODUCT NAME Features Cooling/Heating capacity Air flowrate Indoor (h.m.l.) Dehumidification Fan speeds Sound pressure Indoor (h.m.l.) Power supply Running consumption Refrigerant type Liquid pipe diameter Gas pipe diameter Net weight Indoor / grille Net dimension Indoor (H./W./D.) Net dimension grille (H./W./D.) Units kW BTU/h kcal/h m3/h l/h n° dB(A) V/Ph/Hz kW mm(inch") mm(inch") Kg mm mm Units kW BTU/h kcal/h m3/h l/h n° dB(A) V/Ph/Hz kW mm(inch") mm(inch") Kg mm mm ASS22MH Cooling Heating 2,20 2,50 7.500 8.520 1.890 2.150 700-600-500 0,9 3 + Auto 43-39-36 230/1/50 0,087 0,087 R410A 6,35(1/4") 12,70(1/2") 16/2,5 273x575x575 64x730x730 ASS28MH Cooling Heating 2,80 3,20 9.550 10.920 2.410 2.750 700-600-500 1,0 3 + Auto 43-39-36 230/1/50 0,087 0,087 R410A 6,35(1/4") 12,70(1/2") 16/2,5 273x575x575 64x730x730 ASS36MH Cooling Heating 3,60 4,20 12.280 14.320 3.100 3.610 700-600-500 1,2 3 + Auto 43-39-36 230/1/50 0,087 0,087 R410A 6,35(1/4") 12,70(1/2") 16/2,5 273x575x575 64x730x730 ASS45MH Cooling Heating 4,70 5,20 16.020 17.740 4.040 4.470 750-630-530 2,3 3 + Auto 44-39-36 230/1/50 0,087 0,087 R410A 6,35(1/4") 12,70(1/2") 18/2,5 273x575x575 64x730x730 Units kW BTU/h kcal/h m3/h l/h n° dB(A) V/Ph/Hz kW mm(inch") mm(inch") Kg mm mm ASS56MH Cooling Heating 5,60 6,30 19.100 21.480 4.820 5.420 750-630-530 2,3 3 + Auto 44-39-36 230/1/50 0,087 0,087 R410A 6,35(1/4") 12,70(1/2") 18/2,5 273x575x575 64x730x730 w w w. a r g o c l i m a . c o m Technical data 93 MULTISET V.R.F, DC INVERTER R410A improve your life model ASS73MH models ASS106/140MH V.R.F. Indoor Units ASS 73-106-140 Features Four-way cassette indoor unit to be matched with Multiset V.R.F. DC Inverter systems Automatic change-over between cooling and heating modes Special function during heat pump start-up and defrosting cycle to avoid cool air emission in the room Night set back capability To be managed by the wired and wireless controllers of the Multiset V.R.F. DC Inverter systems (optional) "I Feel" feature and temperature sensor inside the remote control w w w. a r g o c l i m a . c o m Dry function 94 New three-speed centrifugal fan by remote control, granting a better and low noise air diffusion Horizontal flaps swinging or to be set on a fixed position by remote control Special system to avoid condensate dripping from air outlet ribs Anti-mould and anti-bacteria washable filter Integrated pump for condensate discharge Possibility to have a connection for fresh air intake Double-way of air duct in adjacent rooms through pre-drilled holes Dynamic refrigerant control by DC Inverter compressor and circuit, electronic valve and fuzzy logic managed by a powerful microprocessor MULTISET V.R.F, DC INVERTER R410A improve your life Technical data Cooling/Heating capacity Air flowrate Indoor (h.m.l.) Dehumidification Fan speeds Sound pressure Indoor (h.m.l.) Power supply Running consumption Refrigerant type Liquid pipe diameter Gas pipe diameter Net weight Indoor / grille Net dimension Indoor (H./W./D.) Net dimension grille (H./W./D.) PRODUCT NAME Features Cooling/Heating capacity Air flowrate Indoor (h.m.l.) Dehumidification Fan speeds Sound pressure Indoor (h.m.l.) Power supply Running consumption Refrigerant type Liquid pipe diameter Gas pipe diameter Net weight Indoor / grille Net dimension Indoor (H./W./D.) Net dimension grille (H./W./D.) PRODUCT NAME Features Cooling/Heating capacity Air flowrate Indoor (h.m.l.) Dehumidification Fan speeds Sound pressure Indoor (h.m.l.) Power supply Running consumption Refrigerant type Liquid pipe diameter Gas pipe diameter Net weight Indoor / grille Net dimension Indoor (H./W./D.) Net dimension grille (H./W./D.) Units kW BTU/h kcal/h m3/h l/h n° dB(A) V/Ph/Hz kW mm(inch") mm(inch") Kg mm mm Units kW BTU/h kcal/h m3/h l/h n° dB(A) V/Ph/Hz kW mm(inch") mm(inch") Kg mm mm Units kW BTU/h kcal/h m3/h l/h n° dB(A) V/Ph/Hz kW mm(inch") mm(inch") Kg mm mm ASS73MH Cooling Heating 7,30 8,00 24.890 27.280 6.280 6.880 1.140-1.020-840 3,6 3 + Auto 47-45-41 230/1/50 0,175 0,120 R410A 9,52(3/8") 15,88(5/8") 22/6 338x860x860 30x860x860 ASS106MH Cooling Heating 10,60 11,40 36.150 38.880 9.120 9.800 1.920-1.680-1.320 4,6 3 + Auto 53-50-46 230/1/50 0,210 0,150 R410A 9,52(3/8") 15,88(5/8") 27/8 338x1.150x860 30x1.150x860 ASS140MH Cooling Heating 14,00 16,00 47.740 54.560 12.040 13.760 1.920-1.680-1.320 6,3 3 + Auto 53-50-46 230/1/50 0,210 0,150 R410A 9,52(3/8") 15,88(5/8") 27/8 338x1.150x860 30x1.150x860 w w w. a r g o c l i m a . c o m PRODUCT NAME Features 95 MULTISET V.R.F, DC INVERTER R410A improve your life V.R.F. Indoor Units ADS 22-28-36 Features Ducted indoor unit with optional two-way discharge plenum, to be matched with Multiset V.R.F. DC Inverter systems Automatic change-over between cooling and heating modes Special function during heat pump start-up and defrosting cycle to avoid cool air emission in the room Night set back capability To be managed by the wired and wireless controllers of the Multiset V.R.F. DC Inverter systems (optional) w w w. a r g o c l i m a . c o m "I Feel" feature and temperature sensor inside the remote control 96 Dry function Three-speed centrifugal fan by remote control and feature to increase speed/pressure (from 5 to 7 mm W.G.) Anti-mould and anti-bacteria washable filter Integrated pump for condensate discharge Dynamic refrigerant control by DC Inverter compressor and circuit, electronic valve and fuzzy logic managed by a powerful microprocessor MULTISET V.R.F, DC INVERTER R410A improve your life Technical data Cooling/Heating capacity Air flowrate Indoor (h.m.l.) Dehumidification External static pressure (min-max) Fan speeds Sound power Indoor (h.m.l.) Sound pressure Indoor (h.m.l.) at discharge plenum connection Sound pressure Indoor at ducts exit Power supply Running consumption Refrigerant type Liquid pipe diameter Gas pipe diameter Duct diameter of the 2-way discharge plenum (optional) Net weight Indoor Net dimension Indoor (H./W./D.) Net dimension Indoor with plenum (H./W./D.) PRODUCT NAME Features Cooling/Heating capacity Air flowrate Indoor (h.m.l.) Dehumidification External static pressure (min-max) Fan speeds Sound power Indoor (h.m.l.) Sound pressure Indoor (h.m.l.) at discharge plenum connection Sound pressure Indoor at ducts exit Power supply Running consumption Refrigerant type Liquid pipe diameter Gas pipe diameter Duct diameter of the 2-way discharge plenum (optional) Net weight Indoor Net dimension Indoor (H./W./D.) Net dimension Indoor with plenum (H./W./D.) PRODUCT NAME Features Cooling/Heating capacity Air flowrate Indoor (h.m.l.) Dehumidification External static pressure (min-max) Fan speeds Sound power Indoor (h.m.l.) Sound pressure Indoor (h.m.l.) at discharge plenum connection Sound pressure Indoor at ducts exit Power supply Running consumption Refrigerant type Liquid pipe diameter Gas pipe diameter Duct diameter of the 2-way discharge plenum (optional) Net weight Indoor Net dimension Indoor (H./W./D.) Net dimension Indoor with plenum (H./W./D.) Units kW BTU/h kcal/h m3/h l/h mm W.G. n° dB(A) dB(A) dB(A) V/Ph/Hz kW mm(inch") mm(inch") mm kg mm mm Units kW BTU/h kcal/h m3/h l/h mm W.G. n° dB(A) dB(A) dB(A) V/Ph/Hz kW mm(inch") mm(inch") mm kg mm mm Units kW BTU/h kcal/h m3/h l/h mm W.G. n° dB(A) dB(A) dB(A) V/Ph/Hz kW mm(inch") mm(inch") mm kg mm mm ADS22MH Cooling Heating 2,20 2,50 7.500 8.520 1.890 2.150 600-510-440 0,8 5-7 3 + Auto 54-52-49 45-43-40 < 20 230/1/50 0,110 0,110 R410A 6,35(1/4") 12,7(1/2") 200 30 266x926x571 266x926x771 ADS28MH Cooling Heating 2,80 3,20 9.550 10.920 2.410 2.750 600-510-440 0,8 5-7 3 + Auto 54-52-49 45-43-40 < 20 230/1/50 0,110 0,110 R410A 6,35(1/4") 12,7(1/2") 200 30 266x926x571 266x926x771 ADS36MH Cooling Heating 3,60 4,20 12.280 14.320 3.100 3.610 600-510-440 1,5 5-7 3 + Auto 54-52-49 45-43-40 < 20 230/1/50 0,110 0,110 R410A 6,35(1/4") 12,7(1/2") 200 30 266x926x571 266x926x771 w w w. a r g o c l i m a . c o m PRODUCT NAME Features 97 MULTISET V.R.F, DC INVERTER R410A improve your life V.R.F. Indoor Units ADS 45-56-64 Features Ducted indoor unit with optional three-way discharge plenum, to be matched with Multiset V.R.F. DC Inverter systems Automatic change-over between cooling and heating modes Special function during heat pump start-up and defrosting cycle to avoid cool air emission in the room Night set back capability To be managed by the wired and wireless controllers of the Multiset V.R.F. DC Inverter systems (optional) w w w. a r g o c l i m a . c o m "I Feel" feature and temperature sensor inside the remote control 98 Dry function Three-speed centrifugal fan by remote control and feature to increase speed/pressure (from 5 to 7 mm W.G.) Anti-mould and anti-bacteria washable filter Integrated pump for condensate discharge Dynamic refrigerant control by DC Inverter compressor and circuit, electronic valve and fuzzy logic managed by a powerful microprocessor MULTISET V.R.F, DC INVERTER R410A improve your life Technical data Cooling/Heating capacity Air flowrate Indoor (h.m.l.) Dehumidification External static pressure (min-max) Fan speeds Sound power Indoor (h.m.l.) Sound pressure Indoor (h.m.l.) at discharge plenum connection Sound pressure Indoor at ducts exit Power supply Running consumption Refrigerant type Liquid pipe diameter Gas pipe diameter Duct diameter of the 3-way discharge plenum (optional) Net weight Indoor Net dimension Indoor (H./W./D.) Net dimension Indoor with plenum (H./W./D.) PRODUCT NAME Features Cooling/Heating capacity Air flowrate Indoor (h.m.l.) Dehumidification External static pressure (min-max) Fan speeds Sound power Indoor (h.m.l.) Sound pressure Indoor (h.m.l.) at discharge plenum connection Sound pressure Indoor at ducts exit Power supply Running consumption Refrigerant type Liquid pipe diameter Gas pipe diameter Duct diameter of the 3-way discharge plenum (optional) Net weight Indoor Net dimension Indoor (H./W./D.) Net dimension Indoor with plenum (H./W./D.) PRODUCT NAME Features Cooling/Heating capacity Air flowrate Indoor (h.m.l.) Dehumidification External static pressure (min-max) Fan speeds Sound power Indoor (h.m.l.) Sound pressure Indoor (h.m.l.) at discharge plenum connection Sound pressure Indoor at ducts exit Power supply Running consumption Refrigerant type Liquid pipe diameter Gas pipe diameter Duct diameter of the 3-way discharge plenum (optional) Net weight Indoor Net dimension Indoor (H./W./D.) Net dimension Indoor with plenum (H./W./D.) Units kW BTU/h kcal/h m3/h l/h mm W.G. n° dB(A) dB(A) dB(A) V/Ph/Hz kW mm(inch") mm(inch") mm kg mm mm Units kW BTU/h kcal/h m3/h l/h mm W.G. n° dB(A) dB(A) dB(A) V/Ph/Hz kW mm(inch") mm(inch") mm kg mm mm Units kW BTU/h kcal/h m3/h l/h mm W.G. n° dB(A) dB(A) dB(A) V/Ph/Hz kW mm(inch") mm(inch") mm kg mm mm AD45MHG Cooling Heating 4,70 5,20 16.020 17.740 4.040 4.470 875-600-400 2,3 5-7 3 + Auto 54-52-49 45-43-40 < 20 230/1/50 0,138 0,138 R410A 6,35(1/4") 12,7(1/2") 200 35 266x1.132x571 266x1.132x871 ADS56MH Cooling Heating 5,60 6,30 19.100 21.480 4.820 5.420 875-600-400 2,3 5-7 3 + Auto 54-52-49 45-43-40 < 20 230/1/50 0,138 0,138 R410A 6,35(1/4") 12,7(1/2") 200 35 266x1.132x571 266x1.132x871 AD64MHG Cooling Heating 6,40 7,00 21.850 23.870 5.500 6.020 1000-700-600 2,6 5-7 3 + Auto 57-55-52 48-46-43 < 20 230/1/50 0,136 0,136 R410A 9,52(3/8") 15,88(5/8") 200 35 266x1.132x571 266x1.132x871 w w w. a r g o c l i m a . c o m PRODUCT NAME Features 99 MULTISET V.R.F, DC INVERTER R410A improve your life ADS 106/140 ADS 73 V.R.F. Indoor Units ADS 73-106-140 Features Three/four-way ducted indoor unit to be matched with Multiset V.R.F. DC Inverter systems Automatic change-over between cooling and heating modes Special function during heat pump start-up and defrosting cycle to avoid cool air emission in the room Night set back capability To be managed by the wired and wireless controllers of the Multiset V.R.F. DC Inverter systems (optional) "I Feel" feature and temperature sensor inside the remote control w w w. a r g o c l i m a . c o m Dry function 100 Three-speed centrifugal fan by remote control and feature to increase speed/pressure (from 5 to 10 mm W.G.) Integrated pump for condensate discharge Connection for fresh air intake by optional kit with anti-mould and anti-bacteria filter; this kit makes possible the direct access to the internal components for maintenance activities Dynamic refrigerant control by DC Inverter compressor and circuit, electronic valve and fuzzy logic managed by a powerful microprocessor MULTISET V.R.F, DC INVERTER R410A improve your life Technical data Three-way ducted indoor unit PRODUCT NAME Features Cooling/Heating capacity Air flowrate Indoor (h.m.l.) Dehumidification External static pressure (min-max) Fan speeds Sound power Indoor (h.m.l.) Sound pressure Indoor (h.m.l.) at discharge plenum connection Sound pressure Indoor at ducts exit Power supply Running consumption Refrigerant type Liquid pipe diameter Gas pipe diameter Ducts diameter Net weight Indoor Net dimension Indoor (H./W./D.) Units kW BTU/h kcal/h m3/h l/h mm W.G. n° dB(A) dB(A) dB(A) V/Ph/Hz kW mm(inch") mm(inch") mm kg mm ADS73MH Cooling Heating 7,3 8,0 24.890 27.280 6.280 6.880 1.080-900-780 3,5 5-10 3 + Auto 43-39-36 34-30-27 < 20 230/1/50 0,195 0,183 R410A 9,52(3/8") 15,88(5/8") 200 32 310x1.000x630 Four-way ducted indoor unit Cooling/Heating capacity Air flowrate Indoor (h.m.l.) Dehumidification External static pressure (min-max) Fan speeds Sound power Indoor (h.m.l.) Sound pressure Indoor (h.m.l.) at discharge plenum connection Sound pressure Indoor at ducts exit Power supply Running consumption Refrigerant type Liquid pipe diameter Gas pipe diameter Ducts diameter Net weight Indoor Net dimension Indoor (H./W./D.) Units kW BTU/h kcal/h m3/h l/h mm W.G. n° dB(A) dB(A) dB(A) V/Ph/Hz kW mm(inch") mm(inch") mm Kg mm ADS106MH Cooling Heating 10,6 11,4 36.140 38.880 9.120 9.800 1.800-1.560-1.260 4,2 5-10 3 + Auto 47-42-40 38-33-31 < 20 230/1/50 0,327 0,315 R410A 9,52(3/8") 15,88(5/8") 200 47 310x1.480x630 Four-way ducted indoor unit PRODUCT NAME Features Cooling/Heating capacity Air flowrate Indoor (h.m.l.) Dehumidification External static pressure (min-max) Fan speeds Sound power Indoor (h.m.l.) Sound pressure Indoor (h.m.l.) at discharge plenum connection Sound pressure Indoor at ducts exit Power supply Running consumption Refrigerant type Liquid pipe diameter Gas pipe diameter Ducts diameter Net weight Indoor Net dimension Indoor (H./W./D.) Units kW BTU/h kcal/h m3/h l/h mm W.G. n° dB(A) dB(A) dB(A) V/Ph/Hz kW mm(inch") mm(inch") mm Kg mm ADS140MH Cooling Heating 14,00 16,00 47.740 54.560 12.040 13.760 1.980-1.560-1.320 6,6 5-10 3 + Auto 49-46-42 40-37-33 < 20 230/1/50 0,325 0,313 R410A 9,52(3/8") 15,88(5/8") 200 47 310x1.480x630 w w w. a r g o c l i m a . c o m PRODUCT NAME Features 101 MULTISET V.R.F, DC INVERTER R410A improve your life V.R.F. Indoor Units ACS 73-106-140 Features Underceiling indoor unit for Multiset V.R.F. DC Inverter systems Automatic change-over between cooling and heating modes Special function during heat pump start-up and defrosting cycle to avoid cool air emission in the room Night set back capability To be managed by the wired and wireless controllers of the Multiset V.R.F. DC Inverter systems (optional) w w w. a r g o c l i m a . c o m "I Feel" feature and temperature sensor inside the remote control 102 Dry function New three-speed centrifugal fan by remote control, granting a better and low noise air diffusion Horizontal flap swinging or to be set on a fixed position by remote control Vertical flap by manual control Possibility to have a connection for fresh air intake Dynamic refrigerant control by DC Inverter compressor and circuit, electronic valve and fuzzy logic managed by a powerful microprocessor MULTISET V.R.F, DC INVERTER R410A improve your life Technical data Cooling/Heating capacity Air flowrate Indoor (h.m.l.) Dehumidification Fan speeds Sound pressure Indoor (h.m.l.) Power supply Running consumption Refrigerant type Liquid pipe diameter Gas pipe diameter Net weight Indoor Net dimension Indoor (H./W./D.) PRODUCT NAME Features Cooling/Heating capacity Air flowrate Indoor (h.m.l.) Dehumidification Fan speeds Sound pressure Indoor (h.m.l.) Power supply Running consumption Refrigerant type Liquid pipe diameter Gas pipe diameter Net weight Indoor Net dimension Indoor (H./W./D.) PRODUCT NAME Features Cooling/Heating capacity Air flowrate Indoor (h.m.l.) Dehumidification Fan speeds Sound pressure Indoor (h.m.l.) Power supply Running consumption Refrigerant type Liquid pipe diameter Gas pipe diameter Net weight Indoor Net dimension Indoor (H./W./D.) Units kW BTU/h kcal/h m3/h l/h n° dB(A) V/Ph/Hz kW mm(inch") mm(inch") Kg mm Units kW BTU/h kcal/h m3/h l/h n° dB(A) V/Ph/Hz kW mm(inch") mm(inch") Kg mm Units kW BTU/h kcal/h m3/h l/h n° dB(A) V/Ph/Hz kW mm(inch") mm(inch") Kg mm ACS73MH Cooling Heating 7,3 8,0 24.890 27.280 6.280 6.880 1.098-900-840 3,0 3 + Auto 38-36-33 230/1/50 0,043 0,042 R410A 9,52(3/8") 15,88(5/8") 25,0 210x1.180x680 ACS106MH Cooling Heating 10,6 11,4 36.140 38.880 9.120 9.800 1.650-1.380-1.200 3,9 3 + Auto 41-38-35 230/1/50 0,074 0,073 R410A 9,52(3/8") 15,88(5/8") 33,0 210x1.595x680 ACS140MH Cooling Heating 14,00 16,00 47.740 54.560 12.040 13.760 1.800-1.560-1.320 5,6 3 + Auto 43-40-37 230/1/50 0,086 0,085 R410A 9,52(3/8") 15,88(5/8") 33,0 210x1.595x680 w w w. a r g o c l i m a . c o m PRODUCT NAME Features 103 MULTISET V.R.F, DC INVERTER R410A improve your life V.R.F. Indoor Units FC 22-28-36-45-56-64 Features Floor/ceiling indoor unit for Multiset V.R.F. DC Inverter systems Automatic change-over between cooling and heating modes Special function during heat pump start-up and defrosting cycle to avoid cool air emission in the room Night set back capability To be managed by the wired and wireless controllers of the Multiset V.R.F. DC Inverter systems (optional) w w w. a r g o c l i m a . c o m "I Feel" feature and temperature sensor inside the remote control 104 Dry function New three-speed centrifugal fan by remote control, granting a better and low noise air diffusion Horizontal flap swinging or to be set on a fixed position by remote control Vertical flap by manual control Anti-mould and anti-bacteria washable filters; optional active carbon filters Dynamic refrigerant control by DC Inverter compressor and circuit, electronic valve and fuzzy logic managed by a powerful microprocessor MULTISET V.R.F, DC INVERTER R410A improve your life Technical data Cooling/Heating capacity Air flowrate Indoor (h.m.l.) Dehumidification Fan speeds Sound pressure Indoor (h.) Power supply Running consumption Refrigerant type Liquid pipe diameter Gas pipe diameter Net weight Indoor Net dimension Indoor (H./W./D.) PRODUCT NAME Features Cooling/Heating capacity Air flowrate Indoor (h.m.l.) Dehumidification Fan speeds Sound pressure Indoor (h.) Power supply Running consumption Refrigerant type Liquid pipe diameter Gas pipe diameter Net weight Indoor Net dimension Indoor (H./W./D.) PRODUCT NAME Features Cooling/Heating capacity Air flowrate Indoor (h.m.l.) Dehumidification Fan speeds Sound pressure Indoor (h.) Power supply Running consumption Refrigerant type Liquid pipe diameter Gas pipe diameter Net weight Indoor Net dimension Indoor (H./W./D.) Units kW BTU/h kcal/h m3/h l/h n° dB(A) V/Ph/Hz kW mm(inch") mm(inch") Kg mm Units kW BTU/h kcal/h m3/h l/h n° dB(A) V/Ph/Hz kW mm(inch") mm(inch") Kg mm Units kW BTU/h kcal/h m3/h l/h n° dB(A) V/Ph/Hz kW mm(inch") mm(inch") Kg mm FC22MHG Cooling Heating 2,20 2,50 7.500 8.520 1.890 2.150 630-540-450 1,0 3 + Auto 49-43-38 230/1/50 0,065 0,065 R410A 6,35(1/4") 12,70(1/2") 23,5 680x900x190 FC36MHG Cooling Heating 3,60 4,20 12.280 14.320 3.100 3.610 630-540-450 1,3 3 + Auto 49-43-38 230/1/50 0,065 0,065 R410A 6,35(1/4") 12,70(1/2") 23,5 680x900x190 FC56MHG Cooling Heating 5,60 6,30 19.100 21.480 4.820 5.420 720-650-580 2,3 3 + Auto 51-47-43 230/1/50 0,075 0,075 R410A 6,35(1/4") 12,70(1/2") 23,5 680x900x190 FC28MHG Cooling Heating 2,80 3,20 9.550 10.920 2.410 2.750 630-540-450 1,2 3 + Auto 49-43-38 230/1/50 0,065 0,065 R410A 6,35(1/4") 12,70(1/2") 23,5 680x900x190 FC45MHG Cooling Heating 4,70 5,20 16.020 17.740 4.040 4.470 720-650-580 2,3 3 + Auto 51-47-43 230/1/50 0,075 0,075 R410A 6,35(1/4") 12,70(1/2") 23,5 680x900x190 FC64MHG Cooling 6,40 21.850 5.500 0,088 900 3,3 3 + Auto 52-49-46 230/1/50 Heating 7,00 23.870 6.020 0,088 R410A 9,52(3/8") 15,88(5/8") 23,5 680x900x190 w w w. a r g o c l i m a . c o m PRODUCT NAME Features 105 MULTISET V.R.F, DC INVERTER R410A improve your life V.R.F. Indoor Units SD 22-28-36-45-56-64 Features Slim ducted indoor unit, available for floor or wall or ceiling installation, to be matched with Multiset V.R.F. DC Inverter systems Especially projected for hotel applications Automatic change-over between cooling and heating modes Special function during heat pump start-up and defrosting cycle to avoid cool air emission in the room Night set back capability To be managed by the wired and wireless controllers of the Multiset V.R.F. DC Inverter systems (all optional) w w w. a r g o c l i m a . c o m "I Feel" feature and temperature sensor inside the remote control 106 Dry function New three-speed centrifugal fan by remote control, granting a better and low noise air diffusion Anti-mould and anti-bacteria washable filter Optional active carbon filters Dynamic refrigerant control by DC Inverter compressor and circuit, electronic valve and fuzzy logic managed by a powerful microprocessor MULTISET V.R.F, DC INVERTER R410A improve your life Technical data Cooling/Heating capacity Air flowrate Indoor (h.m.l.) Dehumidification Fan speeds Sound pressure Indoor (h.) Power supply Running consumption Refrigerant type Liquid pipe diameter Gas pipe diameter Net weight Indoor Net dimension Indoor (H./W./D.) PRODUCT NAME Features Cooling/Heating capacity Air flowrate Indoor (h.m.l.) Dehumidification Fan speeds Sound pressure Indoor (h.) Power supply Running consumption Refrigerant type Liquid pipe diameter Gas pipe diameter Net weight Indoor Net dimension Indoor (H./W./D.) PRODUCT NAME Features Cooling/Heating capacity Air flowrate Indoor (h.m.l.) Dehumidification Fan speeds Sound pressure Indoor (h.) Power supply Running consumption Refrigerant type Liquid pipe diameter Gas pipe diameter Net weight Indoor Net dimension Indoor (H./W./D.) Units kW BTU/h kcal/h m3/h l/h n° dB(A) V/Ph/Hz kW mm(inch") mm(inch") Kg mm Units kW BTU/h kcal/h m3/h l/h n° dB(A) V/Ph/Hz kW mm(inch") mm(inch") Kg mm Units kW BTU/h kcal/h m3/h l/h n° dB(A) V/Ph/Hz kW mm(inch") mm(inch") Kg mm SD22MHG Cooling Heating 2,20 2,50 7.500 8.520 1.890 2.150 470/380/340 1,0 3 + Auto 37-30-26 230/1/50 0,037 0,037 R410A 6,35(1/4") 12,70(1/2") 25 585x890x190 SD36MHG Cooling Heating 3,60 4,20 12.280 14.320 3.100 3.610 470/380/340 1,3 3 + Auto 37-30-26 230/1/50 0,037 0,037 R410A 6,35(1/4") 12,70(1/2") 25 585x890x190 SD56MHG Cooling Heating 5,60 6,30 19.100 21.480 4.820 5.420 620/540/450 2,3 3 + Auto 45-41-33 230/1/50 0,065 0,065 R410A 6,35(1/4") 12,70(1/2") 25 585x890x190 SD28MHG Cooling Heating 2,80 3,20 9.550 10.920 2.410 2.750 470/380/340 1,2 3 + Auto 37-30-26 230/1/50 0,037 0,037 R410A 6,35(1/4") 12,70(1/2") 25 585x890x190 SD45MHG Cooling Heating 4,70 5,20 16.020 17.740 4.040 4.470 620/540/450 2,3 3 + Auto 45-41-33 230/1/50 0,065 0,065 R410A 6,35(1/4") 12,70(1/2") 25 585x890x190 SD64MHG Cooling Heating 6,40 7,00 21.850 23.870 5.500 6.020 680/600/520 3,3 3 + Auto 49-45-40 230/1/50 0,088 0,088 R410A 9,52(3/8") 15,88(5/8") 25 585x890x190 w w w. a r g o c l i m a . c o m PRODUCT NAME Features 107 MULTISET V.R.F, DC INVERTER R410 improve your life CONTROLS AND ACCESSORIES Infrared remote controller to be used with high-wall indoor units Schedule timer able to manage up to 64 indoor units with customized programming of all features, on/off cycles, etc. Infrared remote controller to be used with cassette and floor/ceiling indoor units System controller to be used to manage only on/off cycles for a system up to 16 groups / 64 indoor units, to be used in matching with other controllers (remote controllers, system controllers, etc.) w w w. a r g o c l i m a . c o m Infrared remote controller to be used with underceiling indoor units 108 System controller to be used to manage and program a system up to 64 indoor units, also without wired controllers; it can be matched with schedule timer and intelligent controller Infrared remote controller to be used, in matching with a special infrared receiver, with the full range of indoor units; it shows the operation status of the air-conditioner System Intelligent Controller to be used to manage and program a system up to 256 indoor units, organized in 4 groups of 64 units each, also without wired controllers; it can be matched with the schedule timer and in case of three/four-group installations it must be connected with the communication adapter Standard wired remote controller with full features control, self-diagnostic and centralized programming capabilities Interface for LonWorks system: this interface is a communication converter for connecting LonWorks to the airconditioner unit control network This unit can control and monitor the status up to 16 groups of indoor units (max 64 indoor units) Simplified wired remote controller to be used with the full range of indoor units; it controls all the main features Interface PLC for outdoor units: can control up to 4 outdoor units. Required for "Demand" control, typical of 3way systems Remote sensor to be used with the full range of indoor units to detect the room temperature when no remote controller sensor or body sensor is used: suggested for air-conditioner systems without remote controller 10A - CONTROLS & ACCESSORIES improve your life ENGINEERING OF REFRIGERANT CIRCUIT, CALCULATION METHODS AND ACCESSORIES Multiset DC Inverter systems demand the respect of precise rules in the engineering of a refrigerant circuit Argoclima gives to system engineers all support and accessories necessary for a correct implementation of an air conditioned system. • Engineering and design software • Distribution kits • Expansion valves with electronic control • Accessories to change the air with outside • Filters as spare parts for indoor units The description of calculation methods for the refrigerant circuit and the accessories is out of the scope of this catalogue; for a correct implementation of a system it's necessary and easy to ask for the complete Multiset V.R.F. DC Inverter technical documentation, directly to our agent or through our Web site at the address www.argoclima.com Our organization of Argo technicians and engineers is at Your disposal for the development of projects, the realization of CAD designs, the test/start of w w w. a r g o c l i m a . c o m the system and the after-sale technical service. 109 w w w. a r g o c l i m a . c o m H E AT R E C O V E R Y U N I T S improve your life HEAT RECOVERY UNITS improve your life REC 400/850 - REC 600/1150 Features To grant the best comfort conditions, the rules in health matters impose to change continuously the air inside the room; this air reciprocation can be assured by a heat recovery unit thanks to its forced ventilation process The air blown out must be replaced with an equal quantity of new air. The air which enters the room has however a different temperature than the air inside it: the heat recovery unit is placed where the air in escape meets with the air in entrance with the precise scope of blowing out the spoiled air and cooling or heating the air in entrance so that reduce energy consumption to keep the desired room conditions The main features of a heat recovery unit are: • the air flowrate (that is the volume of air treated) adequate to the room • the compact dimension of the unit • the thermal efficiency • the filtration efficiency The heat recovery units Argo are available for residential and commercial applications, giving the maximum room comfort together with a sure energy saving If matched with a heating and/or air conditioning system for which a change of the air is necessary, it allows to dimension the equipments for lower Suitable to operate in both summer and winter seasons, these units give always excellent degrees of air quality and comfort These units may be integrated with traditional straight cooling/heat pump air conditioning systems, realized with direct expansion or hydronic technologies, or with traditional heating equipments Using aluminium static heat recovery units, Argo saves more than 50% of the energy that normally would be lost due to spoiled air discharge The thermal exchange chamber is realized with a special aluminium able to efficiently exchange heat between air in entrance and air in escape One fan only is in fixed position while the other fan and the outlet/aspiration air intakes can be moved to the sides of the unit; in this way the system can be easily adapted to every installation context A special connection allows to discharge the condensate which might be produced during the thermal exchange process inside the chamber The heat recovery units Argo are equipped with anti-mould and anti-bacteria filters (optional kit are available as spare parts); a special system allows an easy access to the internal components for maintenance and control activities w w w. a r g o c l i m a . c o m levels of thermal power, granting management savings 111 HEAT RECOVERY UNITS improve your life REC 400/850 - REC 600/1150 Technical Data PRODUCT NAME Features Nominal air capacity Max. air flow Static Pressure Max. total absorption Max. total consumption Sound power Poles Fan speeds Protection grade Isolation grade Power supply Thermal efficiency Max. recuperated thermal power Renewal air outlet temperature Filtration efficiency Filters dimension Active carbon filters Width Depth Height Net weight Ducts diameter Outlet air intakes dimension Aspiration air intakes dimension w w w. a r g o c l i m a . c o m REC 400/850 112 Units m3/h m3/h Pa A W dB(A) n° n° IP V/Ph/Hz % kW °C EN779 mm mm mm mm Kg mm mm mm REC 400/850 REC 600/1150 900 856 50 2,6 598 53 2 4 20 F 230/1/50 54 2,73 8,5 G4 500x230x48 optional 950 950 310 50 200 - 1200 1160 50 2,46 562 53 4 3 20 B 230/1/50 54,6 4,71 8,6 G4 500x370x48 optional 950 950 450 70 230x205 390x370 REC 600/1150 OPERATING LIMITS - R410A OPERATION SOUND The sound pressure levels indicated in the catalogue are measured in anechoic chamber, considering a distance of 2 meters from the portable or the indoor unit (split/package/multiset) in closed room, 4 meters from the outdoor unit. w w w. a r g o c l i m a . c o m improve your life 113 w w w. a r g o c l i m a . c o m P O R TA B L E R 4 0 7 C improve your life SPLIT PORTABLE R407C improve your life OSCAR TWIN 9 Split portable air conditioner, with a small condensing case, specifically projected to be placed on balcony or window Weekly programmable digital timer and electronic thermostat Two-speed fan Frontal air-intake, making possible its placement even between two walls Automatic condensate vaporization through the case AeroQuip quick connectors to easily disconnect and re-connect the outdoor unit for a fixed installation Adjustable air louver, granting the best fresh air diffusion Anti-mould and anti-bacteria washable filters Auto restart after a power supply black out Electronic protection against over-pressures High efficiency rotary compressor AeroQuip quick connectors Easy to move thanks to its comfortable handles and special multidirectional wheels Digital Timer Accessories for the outside fixed installation of the case supplied wth the unit PRODUCT NAME Features Cooling capacity Energy label class E.E.R. Air flowrate (h.l.) Dehumidification Fan speeds (Indoor / Outdoor) Sound pressure Indoor (h.l.) Sound pressure Outdoor (h.) Power supply Running consumption Annual energy consumption-cooling mode(500h)-Dir. 2002/31/CE Refrigerant type Standard pipe lenght Additional pipe lenght Max. height between units (Outdoor on the top) Max. height between units (Indoor on the top) Net weight Indoor / Outdoor Net dimension Indoor (H./W./D.) Net dimension Outdoor (H./W./D.) Units kW BTU/h kcal/h ABCDEFG (kW/kW) m3/h l/h n° dB(A) dB(A) V/Ph/Hz kW kWh m m m m Kg mm mm OSCAR TWIN 9 Cooling 2,48 8.500 2.130 D 2,67 420-300 0,8 2/1 38-31 47 230/1/50 0,930 465 R407C 2 2-4 1,2 5,2 39/8,5 800x470x310 435x440x230 The technical data here indicated are in compliance with the European standard EN14511 - Directive 2002/31/EC w w w. a r g o c l i m a . c o m Optional pipe-extension kits connecting Indoor and Outdoor units (2 and 4m) 115 SPLIT PORTABLE R407C improve your life OSCAR TWIN 11 Split portable air conditioner, with a small condensing case, specifically projected to be placed on balcony or window Equipped with weekly programmable digital timer and electronic thermostat Two-speed fan Frontal air-intake, making possible its placement even between two walls Automatic condensate vaporization through the case AeroQuip quick connectors to easily disconnect and re-connect the outdoor unit for a fixed installation Adjustable air louver, granting the best fresh air diffusion Anti-mould and anti-bacteria washable filters Auto restart after a power supply black out AeroQuip quick connectors Electronic protection against over-pressures High efficiency rotary compressor Easy to move thanks to its comfortable handles and special multidirectional wheels Acccessories for the outside fixed installation of the case supplied wth the unit Digital timer w w w. a r g o c l i m a . c o m Optional pipe-extension kits connecting Indoor and Outdoor units (2 and 4m) 116 PRODUCT NAME Features Cooling capacity Energy label class E.E.R. Air flowrate (h.l.) Dehumidification Fan speeds (Indoor / Outdoor) Sound pressure Indoor (h.l.) Sound pressure Outdoor (h.) Power supply Running consumption Annual energy consumption-cooling mode(500h)-Dir. 2002/31/CE Refrigerant type Standard pipe lenght Additional pipe lenght Max. height between units (Outdoor on the top) Max. height between units (Indoor on the top) Net weight Indoor / Outdoor Net dimension Indoor (H./W./D.) Net dimension Outdoor (H./W./D.) Units kW BTU/h kcal/h ABCDEFG (kW/kW) m3/h l/h n° dB(A) dB(A) V/Ph/Hz kW kWh m m m m Kg mm mm OSCAR TWIN 11 Cooling 2,90 9.900 2.490 C 2,82 420-300 1,0 2/1 39-32 47 230/1/50 1,030 515 R407C 2 2-4 1,2 5,2 40/9,5 800x470x310 435x440x230 The technical data here indicated are in compliance with the European standard EN14511 - Directive 2002/31/EC SPLIT PORTABLE R407C improve your life OSCAR TWIN 14 Split portable air conditioner, with a small condensing case, specifically projected to be placed on balcony or window Equipped with weekly programmable digital timer and electronic thermostat Two-speed fan Frontal air-intake, making possible its placement even between two walls Automatic condensate vaporization through the case AeroQuip quick connectors to easily disconnect and re-connect the outdoor unit for a fixed installation Adjustable air louver, granting the best fresh air diffusion Anti-mould and anti-bacteria washable filters Auto restart after a power supply black out AeroQuip quick connectors Electronic protection against over-pressures High efficiency rotary compressor Easy to move thanks to its comfortable handles and special multidirectional wheels Acccessories for the outside fixed installation of the case supplied with the unit Digital timer PRODUCT NAME Features Cooling capacity Energy label class E.E.R. Air flowrate (h.l.) Dehumidification Fan speeds (Indoor / Outdoor) Sound pressure Indoor (h.l.) Sound pressure Outdoor (h.) Power supply Running consumption Annual energy consumption-cooling mode(500h)-Dir. 2002/31/CE Refrigerant type Standard pipe lenght Additional pipe lenght Max. height between units (Outdoor on the top) Max. height between units (Indoor on the top) Net weight Indoor / Outdoor Net dimension Indoor (H./W./D.) Net dimension Outdoor (H./W./D.) Units kW BTU/h kcal/h ABCDEFG (kW/kW) m3/h l/h n° dB(A) dB(A) V/Ph/Hz kW kWh m m m m Kg mm mm OSCAR TWIN 14 Cooling 3,70 12.700 3.180 C 2,85 460-350 1,6 2/1 40-33 45 230/1/50 1,300 650 R407C 2 2-4 1,2 5,2 41/13 800x470x310 490x525x250 The technical data here indicated are in compliance with the European standard EN14511 - Directive 2002/31/EC w w w. a r g o c l i m a . c o m Optional pipe-extension kits connecting Indoor and Outdoor units (2 and 4m) 117 FLOOR SPLIT R407C improve your life ULISSE 10/13 CL Floor split air conditioner realized in only 24 cm of depht, suitable for fixed or moveable installations Small condensing case, specifically projected to be placed on balcony or window Infrared remote control with digital 24h timer, night set back, start-up of air-conditioning or dehumidifying or ventilation only modes, temperature digital adjustment and room temperature control by a special sensor inside the remote control "I Feel" feature Dry function Three-speed fan by remote control Frontal air-intake, making possible its placement even between two walls Automatic condensate vaporization through the case AeroQuip quick connectors to easily disconnect and re-connect the outdoor unit for a fixed installation Adjustable air louver, granting the best fresh air diffusion Anti-mould and anti-bacteria washable filters Infrared remote control with temperature sensor Auto restart after a power supply black out Electronic protection against over-pressures High efficiency rotary compressor w w w. a r g o c l i m a . c o m Acccessories for the outside fixed installation of the case supplied wth the unit 118 Optional pipe-extension kits connecting Indoor and Outdoor units (2 and 4 m) PRODUCT NAME Features Cooling capacity Energy label class E.E.R. Air flowrate (h.l.) Dehumidification Fan speeds (Indoor / Outdoor) Sound pressure Indoor (h.m.l.) Sound pressure Outdoor (h.) Power supply Running consumption Annual energy consumption-cooling mode(500h)-Dir. 2002/31/CE Refrigerant type Standard pipe lenght Additional pipe lenght Max. height between units (Outdoor on the top) Max. height between units (Indoor on the top) Net weight Indoor / Outdoor Net dimension Indoor (H./W./D.) Net dimension Outdoor (H./W./D.) Units kW BTU/h kcal/h ABCDEFG (kW/kW) m3/h l/h n° dB(A) dB(A) V/Ph/Hz kW kWh m m m m Kg mm mm ULISSE 10 CL Cooling 2,65 9.100 2.280 D 2,62 370 1,2 3 + Auto / 1 36-33-32 47 230/1/50 1,010 505 R407C 2 2-4 1,2 5,2 44/9,5 790x580x245 435x440x230 The technical data here indicated are in compliance with the European standard EN14511 - Directive 2002/31/EC ULISSE 13 CL Cooling 3,67 12.500 3.160 C 2,82 450 1,5 3 + Auto / 1 37-34-33 45 230/1/50 1,300 650 R407C 2 2-4 1,2 5,2 44/15 790x580x245 490x525x250 FLOOR SPLIT R407C improve your life ULISSE 10 HL Floor split straight cooling and heat pump air conditioner Realized in only 24 cm of depht, suitable for fixed or moveable floor installations Small condensing case, specifically projected to be placed on balcony or window Infrared remote control with digital 24h timer, night set back, start-up of air-conditioning or dehumidifying or ventilation only modes, temperature digital adjustment and room temperature control by a special sensor inside the remote control "I Feel" feature Dry function Three-speed fan by remote control Frontal air-intake, making possible its placement even between two walls Automatic condensate vaporization through the case AeroQuip quick connectors to easily disconnect and re-connect the outdoor unit for a fixed installation Adjustable air louver, granting the best fresh air diffusion Anti-mould and anti-bacteria washable filters Infrared remote control with temperature sensor Auto restart after a power supply black out Electronic protection against over-pressures Acccessories for the outside fixed installation of the case supplied wth the unit Optional pipe-extension kits connecting Indoor and Outdoor units (2 and 4 m) PRODUCT NAME Features Cooling capacity Energy label class E.E.R. Air flowrate (h.l.) Dehumidification Fan speeds (Indoor / Outdoor) Sound pressure Indoor (h.m.l.) Sound pressure Outdoor (h.) Power supply Running consumption Annual energy consumption-cooling mode(500h)-Dir. 2002/31/CE Refrigerant type Standard pipe lenght Additional pipe lenght Max. height between units (Outdoor on the top) Max. height between units (Indoor on the top) Net weight Indoor / Outdoor Net dimension Indoor (H./W./D.) Net dimension Outdoor (H./W./D.) Units kW BTU/h kcal/h ABCDEFG (kW/kW) m3/h l/h n° dB(A) dB(A) V/Ph/Hz kW kWh m m m m Kg mm mm ULISSE 10 HL Cooling Heating 2,80 3,14 9.600 10.700 2.410 2.700 D C 2,64 3,31 370 1,2 3 + Auto / 1 36-33-32 45 230/1/50 1,060 0,950 530 R407C 2 2-4 1,2 5,2 44/15 790x580x245 490x525x250 The technical data here indicated are in compliance with the European standard EN14511 - Directive 2002/31/EC w w w. a r g o c l i m a . c o m High efficiency rotary compressor 119 w w w. a r g o c l i m a . c o m S P L I T / M U LT I S P L I T O N / O F F R 4 0 7 C improve your life WALL - ON/OFF R407C improve your life AWR 515 HL High wall straight cooling and heat pump air conditioner Automatic change-over between cooling and heating mode Infrared remote control with 24h digital timer and full features control Temperature sensor inside the remote control “Auto I Feel” feature, give you the best comfort conditions Dry function Tree speeds tangential fan by remote control Night set back capability Heating function disable during defrosting cycle Horizontal flap swinging or to be set on a fixed position by remote control Vertical flap by manual control Anti-mould and anti-bacteria washable filters Active carbon filters REMOTE CONTROL Auto restart after a power supply black out Over-pressure electronic protection of the compressor Double way (right and left) to discharge the condensate PRODUCT NAME Indoor unit Outdoor unit Features Cooling/Heating capacity Energy label class E.E.R. / C.O.P. Air flowrate Indoor (h.m.l.) Dehumidification Fan speeds (Indoor / Outdoor) Sound pressure Indoor (h.m.l.) Sound pressure Outdoor (h.) Power supply Running consumption Annual energy cons.- cooling mode (500h) - Directive 2002/31/CE Compressor type Refrigerant type Liquid pipe diameter Gas pipe diameter Max. pipe lenght with gas standard charge Max. pipe lenght with gas additional charge Gas additional charge Max. height between units (Outdoor on top) Max. height between units (Indoor on top) Net weight Indoor / Outdoor Net dimension Indoor (H./W./D.) Net dimension Outdoor (H./W./D.) Units kW BTU/h kcal/h ABCDEFG (kW/kW) m3/h l/h n° dB(A) dB(A) V/Ph/Hz kW kWh mm(inch") mm(inch") m m gr/m m m Kg mm mm AWR515HL AWR518HL AER515SH Cooling Heating 4,10 5,60 14.000 19.100 3.600 4.900 F E 2,21 2,75 760-630-550 2,3 3 + Auto / 1 46-41-39 45 230/1/50 1,85 2,04 925 Rotary R407C 6,35(1/4") 12,7(1/2") 7,5 20 25 7 7 12/50 285x995x206 630x830x305 The technical data here indicated are in compliance with the European standard EN14511 - Directive 2002/31/EC w w w. a r g o c l i m a . c o m High efficiency rotary compressor 121 WALL - ON/OFF R407C improve your life AWR 518 HL/HL3 High wall straight cooling and heat pump air conditioner Single phase (230/1/50) and three phase (400/3N/50) available versions Automatic change-over between cooling and heating mode Infrared remote control with 24h digital timer and full features control Temperature sensor inside the remote control “Auto I Feel” feature, give you the best comfort conditions Dry function Tree speeds tangential fan by remote control Night set back capability Heating function disable during defrosting cycle Horizontal flap swinging or to be set on a fixed position by remote control Vertical flap by manual control Anti-mould and anti-bacteria washable filters Active carbon filters REMOTE CONTROL Auto restart after a power supply black out Over-pressure electronic protection of the compressor Double way (right and left) to discharge the condensate w w w. a r g o c l i m a . c o m High efficiency rotary compressor 122 PRODUCT NAME Indoor unit Outdoor unit Features Cooling/Heating capacity Energy label class E.E.R. / C.O.P. Air flowrate Indoor (h.m.l.) Dehumidification Fan speeds (Indoor / Outdoor) Sound pressure Indoor (h.m.l.) Sound pressure Outdoor (h.) Power supply Running consumption Annual energy cons.- cooling mode (500h) - Directive 2002/31/CE Compressor type Refrigerant type Liquid pipe diameter Gas pipe diameter Max. pipe lenght with gas standard charge Max. pipe lenght with gas additional charge Gas additional charge Max. height between units (Outdoor on top) Max. height between units (Indoor on top) Net weight Indoor / Outdoor Net dimension Indoor (H./W./D.) Net dimension Outdoor (H./W./D.) Units kW BTU/h kcal/h ABCDEFG (kW/kW) m3/h l/h n° dB(A) dB(A) V/Ph/Hz kW kWh mm(inch") mm(inch") m m gr/m m m Kg mm mm AWR518HL AER518SHB Cooling Heating 4,80 6,60 16.400 22.500 4.200 5.700 G E 2,09 2,72 760-630-550 2,3 3 + Auto / 1 46-41-39 45 230/1/50 2,30 2,43 1.150 Rotary R407C 6,35(1/4") 12,7(1/2") 7,5 20 25 7 7 12/59 285x995x206 630x830x305 AWR518HL AER518SH3B Cooling Heating 4,70 6,40 16.100 21.900 4.100 5.500 F D 2,22 2,91 760-630-550 2,3 3 + Auto / 1 46-41-39 46 400/3/50 2,12 2,20 1.060 Rotary R407C 6,35(1/4") 12,7(1/2") 7,5 20 25 7 7 12/59 285x995x206 630x830x305 The technical data here indicated are in compliance with the European standard EN14511 - Directive 2002/31/EC WALL - ON/OFF R407C improve your life AWR 522 HL/HL3 High wall straight cooling and heat pump air conditioner Single phase (230/1/50) and three phase (400/3N/50) available versions Automatic change-over between cooling and heating mode Infrared remote control with 24h digital timer and full features control Temperature sensor inside the remote control “Auto I Feel” feature, give you the best comfort conditions Dry function Tree speeds tangential fan by remote control Night set back capability Heating function disable during defrosting cycle Horizontal flap swinging or to be set on a fixed position by remote control Vertical flap by manual control Anti-mould and anti-bacteria washable filters Active carbon filters REMOTE CONTROL Auto restart after a power supply black out Over-pressure electronic protection of the compressor Double way (right and left) to discharge the condensate PRODUCT NAME Indoor unit Outdoor unit Features Cooling/Heating capacity Energy label class E.E.R. / C.O.P. Air flowrate Indoor (h.m.l.) Dehumidification Fan speeds (Indoor / Outdoor) Sound pressure Indoor (h.m.l.) Sound pressure Outdoor (h.) Power supply Running consumption Annual energy cons.- cooling mode (500h) - Directive 2002/31/CE Compressor type Refrigerant type Liquid pipe diameter Gas pipe diameter Max. pipe lenght with gas standard charge Max. pipe lenght with gas additional charge Gas additional charge Max. height between units (Outdoor on top) Max. height between units (Indoor on top) Net weight Indoor / Outdoor Net dimension Indoor (H./W./D.) Net dimension Outdoor (H./W./D.) Units kW BTU/h kcal/h ABCDEFG (kW/kW) m3/h l/h n° dB(A) dB(A) V/Ph/Hz kW kWh mm(inch") mm(inch") m m gr/m m m Kg mm mm AWR522HL AER522SH Cooling Heating 5,85 7,00 20.000 23.900 5.100 6.100 E E 2,44 2,75 830-720-630 3,3 3 + Auto / 1 49-45-42 48 230/1/50 2,40 2,55 1.200 Rotary R407C 6,35(1/4") 15,88(5/8") 7,5 30 25 7 7 12/70 285x995x206 835x850x305 AWR522HL AER522SH3 Cooling Heating 5,60 7,40 19.100 25.300 4.900 6.400 G F 2,07 2,47 830-720-630 3,3 3 + Auto / 1 49-45-42 48 400/3/50 2,70 3,00 1.350 Rotary R407C 6,35(1/4") 15,88(5/8") 7,5 30 25 7 7 12/70 285x995x206 835x850x305 The technical data here indicated are in compliance with the European standard EN14511 - Directive 2002/31/EC w w w. a r g o c l i m a . c o m High efficiency rotary compressor 123 CASSETTE ON/OFF R407C improve your life ASR 518 HL/HL3 Cassette straight cooling and heat pump air conditioner Single phase (230/1/50) and three phase (400/3N/50) available versions Automatic change-over between cooling and heating mode Infrared remote control with 24h digital timer and full features control Temperature sensor inside the remote control “Auto I Feel” feature, give you the best comfort conditions Dry function Tree speeds centrifugal fan by remote control Night set back capability Four horizontal flap swinging or to be set on a fixed position by remote control Anti-mould and anti-bacteria washable filters Integrated pump for condensate discharge REMOTE CONTROL Auto restart after a power supply black out Over-pressure electronic protection of the compressor Single duct capability to move air conditioned in a near room w w w. a r g o c l i m a . c o m High efficiency rotary compressor 124 PRODUCT NAME Indoor unit Outdoor unit Features Cooling/Heating capacity Energy label class E.E.R. / C.O.P. Air flowrate Indoor (h.m.l.) Dehumidification Fan speeds (Indoor / Outdoor) Sound pressure Indoor (h.m.l.) Sound pressure Outdoor (h.) Power supply Running consumption Annual energy cons.- cooling mode (500h) - Directive 2002/31/CE Compressor type Refrigerant type Liquid pipe diameter Gas pipe diameter Max. pipe lenght with gas standard charge Max. pipe lenght with gas additional charge Gas additional charge Max. height between units (Outdoor on top) Max. height between units (Indoor on top) Net weight Indoor / grille / Outdoor Net dimension Indoor (H./W./D.) Net dimension grille (H./W./D.) Net dimension Outdoor (H./W./D.) Units kW BTU/h kcal/h ABCDEFG (kW/kW) m3/h l/h n° dB(A) dB(A) V/Ph/Hz kW kWh mm(inch") mm(inch") m m gr/m m m Kg mm mm mm ASR518HL AER518SHB Cooling Heating 4,80 6,60 16.400 22.500 4.150 5.700 G E 2,09 2,72 750-630-530 2,3 3 + Auto / 1 44-39-36 45 230/1/50 2,30 2,43 1.150 Rotary R407C 6,35(1/4") 12,7(1/2") 7,5 20 25 7 7 18/2,5/52 273x575x575 64x730x730 630x830x305 ASR518HL AER518SH3B Cooling Heating 4,70 6,40 16.100 21.900 4.050 5.500 F D 2,22 2,91 750-630-530 2,3 3 + Auto / 1 44-39-36 45 400/3/50 2,12 2,20 1.060 Rotary R407C 6,35(1/4") 12,7(1/2") 7,5 20 25 7 7 18/2,5/52 273x575x575 64x730x730 630x830x305 The technical data here indicated are in compliance with the European standard EN14511 - Directive 2002/31/EC DUCTED ON/OFF R407C improve your life ADR518 HL/HL3 Ducted straight cooling and heat pump air conditioner with optional three ways air channel Single phase (230/1/50) and three phase (400/3N/50) available versions Automatic change-over between cooling and heating mode Special infrared receiver and remote control with 24h digital timer and full features control Temperature sensor inside the remote control “Auto I Feel” feature, give you the best comfort conditions Dry function Tree speeds centrifugal fan by remote control and feature to increase speed/pressure (from 5 to 7 mm c.a.) Night set back capability Anti-mould and anti-bacteria washable filters Integrated pump for condensate discharge Auto restart after a power supply black out REMOTE CONTROL Over-pressure electronic protection of the compressor PRODUCT NAME Indoor unit Outdoor unit Features Cooling/Heating capacity Energy label class E.E.R. / C.O.P. Air flowrate (h.m.l.) Dehumidification External static pressure (min-max) Fan speeds (Indoor / Outdoor) Sound power Indoor (h.m.l.) Sound pressure Indoor (h.m.l.) at discharge plenum connection Sound pressure Indoor at ducts exit Sound pressure Outdoor (h.) Power supply Running consumption Annual energy cons.- cooling mode (500h) - Directive 2002/31/CE Compressor type Refrigerant type Liquid pipe diameter Gas pipe diameter Max. pipe lenght with gas standard charge Max. pipe lenght with gas additional charge Gas additional charge Max. height between units (Outdoor on top) Max. height between units (Indoor on top) Duct diameter of the 3-way discharge plenum (optional) Net weight Indoor / Indoor with plenum / Outdoor Net dimension Indoor (H./W./D.) Net dimension Indoor with plenum (H./W./D.) Net dimension Outdoor (H./W./D.) Units kW BTU/h kcal/h ABCDEFG (kW/kW) m3/h l/h mm W.G. n° dB(A) dB(A) dB(A) dB(A) V/Ph/Hz kW kWh mm(inch") mm(inch") m m gr/m m m mm Kg mm mm mm ADR518HL AER518SHB Cooling Heating 4,80 6,60 16.400 22.500 4.150 5.700 G E 2,09 2,72 760-630-550 2,3 5-7 3 + Auto / 1 54-47-42 45-38-33 < 20 45 230/1/50 2,300 2,430 1.150 Rotary R407C 6,35(1/4") 12,7(1/2") 7,5 20 25 7 7 200 35/42,5/59 266x1.132x571 266x1.132x771 630x830x305 ADR518HL AER518SH3B Cooling Heating 4,7 6,4 16.100 21.900 4.050 5.500 F D 2,22 2,91 760-630-550 2,3 5-7 3 + Auto / 1 54-47-42 45-38-33 < 20 46 400/3/50 2,120 2,200 1.060 Rotary R407C 6,35(1/4") 12,7(1/2") 7,5 20 25 7 7 200 35/42,5/59 266x1.132x571 266x1.132x771 630x830x305 The technical data here indicated are in compliance with the European standard EN14511 - Directive 2002/31/EC w w w. a r g o c l i m a . c o m High efficiency rotary compressor 125 DUCTED ON/OFF R407C improve your life ADR 522 HL/HL3 Ducted straight cooling and heat pump air conditioner with optional three ways air channel Single phase (230/1/50) and three phase (400/3N/50) available versions Automatic change-over between cooling and heating mode Special infrared receiver and remote control with 24h digital timer and full features control Temperature sensor inside the remote control “Auto I Feel” feature, give you the best comfort conditions Dry function Tree speeds centrifugal fan by remote control and feature to increase speed/pressure (from 5 to 7 mm c.a.) Night set back capability Anti-mould and anti-bacteria washable filters Integrated pump for condensate discharge REMOTE CONTROL Auto restart after a power supply black out Over-pressure electronic protection of the compressor w w w. a r g o c l i m a . c o m High efficiency rotary compressor 126 PRODUCT NAME Indoor unit Outdoor unit Features Cooling/Heating capacity Energy label class E.E.R. / C.O.P. Air flowrate (h.m.l.) Dehumidification External static pressure (min-max) Fan speeds (Indoor / Outdoor) Sound power Indoor (h.m.l.) Sound pressure Indoor (h.m.l.) at discharge plenum connection Sound pressure Indoor at ducts exit Sound pressure Outdoor (h.) Power supply Running consumption Annual energy cons.- cooling mode (500h) - Directive 2002/31/CE Compressor type Refrigerant type Liquid pipe diameter Gas pipe diameter Max. pipe lenght with gas standard charge Max. pipe lenght with gas additional charge Gas additional charge Max. height between units (Outdoor on top) Max. height between units (Indoor on top) Duct diameter of the 3-way discharge plenum (optional) Net weight Indoor / Indoor with plenum / Outdoor Net dimension Indoor (H./W./D.) Net dimension Indoor with plenum (H./W./D.) Net dimension Outdoor (H./W./D.) Units kW BTU/h kcal/h ABCDEFG (kW/kW) m3/h l/h mm W.G. n° dB(A) dB(A) dB(A) dB(A) V/Ph/Hz kW kWh mm(inch") mm(inch") m m gr/m m m mm Kg mm mm mm ADR522HL AER522SH Cooling Heating 6,00 7,10 20.500 24.200 5.160 6.110 E D 2,50 2,96 1000-700-600 2,6 5-7 3 + Auto / 1 57-49-46 48-40-37 < 20 48 230/1/50 2,400 2,400 1.200 Rotary R407C 6,35(1/4") 15,88(5/8") 7,5 30 25 7 7 200 35/42,5/70 266x1.132x571 266x1.132x771 835x850x305 ADR522HL AER522SH3 Cooling Heating 6,50 8,00 22.200 2.800 5.590 6.880 F D 2,36 2,81 1000-700-600 3,0 5-7 3 + Auto / 1 57-49-46 48-40-37 < 20 48 400/3/50 2,750 2,850 1.375 Rotary R407C 6,35(1/4") 15,88(5/8") 7,5 30 25 7 7 200 35/42,5/70 266x1.132x571 266x1.132x771 835x850x305 The technical data here indicated are in compliance with the European standard EN14511 - Directive 2002/31/EC FLOOR-CEILING ON/OFF R407C improve your life FCR 518 HL/HL3 Floor/Ceiling straight cooling and heat pump air conditioner Single phase (230/1/50) and three phase (400/3N/50) available versions Automatic change-over between cooling and heating mode Infrared remote control with 24h digital timer and full features control Temperature sensor inside the remote control “Auto I Feel” feature, give you the best comfort conditions Dry function Tree speeds centrifugal fan by remote control Night set back capability Anti-mould and anti-bacteria washable filters Auto restart after a power supply black out REMOTE CONTROL Over-pressure electronic protection of the compressor PRODUCT NAME Indoor unit Outdoor unit Features Cooling/Heating capacity Energy label class E.E.R. / C.O.P. Air flowrate Indoor (h.m.l.) Dehumidification Fan speeds (Indoor / Outdoor) Sound pressure Indoor (h.m.l.) Sound pressure Outdoor (h.) Power supply Running consumption Annual energy cons.- cooling mode (500h) - Directive 2002/31/CE Compressor type Refrigerant type Liquid pipe diameter Gas pipe diameter Max. pipe lenght with gas standard charge Max. pipe lenght with gas additional charge Gas additional charge Max. height between units (Outdoor on top) Max. height between units (Indoor on top) Net weight Indoor / Outdoor Net dimension Indoor (H./W./D.) Net dimension Outdoor (H./W./D.) Units kW BTU/h kcal/h ABCDEFG (kW/kW) m3/h l/h n° dB(A) dB(A) V/Ph/Hz kW kWh mm(inch") mm(inch") m m gr/m m m Kg mm mm FCR518HL AER518SHB Cooling Heating 4,80 6,60 16.400 22.500 4.130 5.680 G E 2,09 2,72 800-700-590 2,3 3 + Auto / 1 51-47-43 45 230/1/50 2,30 2,43 1.150 Rotary R407C 6,35(1/4") 12,7(1/2") 7,5 20 25 7 7 23,5/59 680x900x190 630x830x305 FCR518HL AER518SH3B Cooling Heating 4,70 6,40 16.100 21.900 4.040 5.500 F D 2,22 2,91 800-700-590 2,3 3 + Auto / 1 51-47-43 45 400/3/50 2,12 2,20 1.060 Rotary R407C 6,35(1/4") 12,7(1/2") 7,5 20 25 7 7 23,5/59 680x900x190 630x830x305 The technical data here indicated are in compliance with the European standard EN14511 - Directive 2002/31/EC w w w. a r g o c l i m a . c o m High efficiency rotary compressor 127 FLOOR-CEILING ON/OFF R407C improve your life FCR 522 HL/HL3 Floor/Ceiling straight cooling and heat pump air conditioner Single phase (230/1/50) and three phase (400/3N/50) available versions Automatic change-over between cooling and heating mode Infrared remote control with 24h digital timer and full features control Temperature sensor inside the remote control “Auto I Feel” feature, give you the best comfort conditions Dry function Tree speeds centrifugal fan by remote control Night set back capability Anti-mould and anti-bacteria washable filters Auto restart after a power supply black out REMOTE CONTROL Over-pressure electronic protection of the compressor w w w. a r g o c l i m a . c o m High efficiency rotary compressor 128 PRODUCT NAME Indoor unit Outdoor unit Features Cooling/Heating capacity Energy label class E.E.R. / C.O.P. Air flowrate Indoor (h.m.l.) Dehumidification Fan speeds (Indoor / Outdoor) Sound pressure Indoor (h.m.l.) Sound pressure Outdoor (h.) Power supply Running consumption Annual energy cons.- cooling mode (500h) - Directive 2002/31/CE Compressor type Refrigerant type Liquid pipe diameter Gas pipe diameter Max. pipe lenght with gas standard charge Max. pipe lenght with gas additional charge Gas additional charge Max. height between units (Outdoor on top) Max. height between units (Indoor on top) Net weight Indoor / Outdoor Net dimension Indoor (H./W./D.) Net dimension Outdoor (H./W./D.) Units kW BTU/h kcal/h ABCDEFG (kW/kW) m3/h l/h n° dB(A) dB(A) V/Ph/Hz kW kWh mm(inch") mm(inch") m m gr/m m m Kg mm mm FCR522HL AER522SH Cooling Heating 5,85 7,00 20.000 23.900 5.030 6.020 E E 2,44 2,75 840-770-670 3,3 3 + Auto / 1 52-49-46 48 230/1/50 2,40 2,55 1.200 Rotary R407C 6,35(1/4") 15,88(5/8") 7,5 30 25 7 7 23,5/70 680x900x190 835x850x305 FCR522HL AER522SH3 Cooling Heating 5,60 7,40 19.100 25.300 4.820 6.370 G F 2,07 2,47 840-770-670 3,3 3 + Auto / 1 52-49-46 48 400/3/50 2,70 3,00 1.350 Rotary R407C 6,35(1/4") 15,88(5/8") 7,5 30 25 7 7 23,5/70 680x900x190 835x850x305 The technical data here indicated are in compliance with the European standard EN14511 - Directive 2002/31/EC MULTISPLIT ON/OFF R407C Hi-wall AWR609C L improve your life INDOOR UNITS MATC HING TABLE Cassette Ducted Floor-ceiling ASR609C L ADR609C L AFR609C L AER 518 DC Dual Split air conditioner for cooling and dehumidification (DRY) mode System with two independent refrigerant circuits Maximum cooling capacity : 5,3 kW, divided into two parts 2,65 kW each Fully mixed matching possibility With a proper connection of the cassette or ducted indoor units it is possible to manage up to two groups of two rooms each or one single room with four air sendout points. Each Indoor unit is managed by its own remote control In case more indoor units are installed in the same room, it is possible to address every remote control to its own indoor unit only, so that to avoid any interference Single-phase power supply Auto restart after a power supply black out REMOTE CONTROL Over-pressure electronic protection of the compressor Double rotary compressor Indoor units are the same used for single-split systems Cooling/Heating capacity Energy label class E.E.R. / C.O.P. Air flowrate Outdoor (h.) Fan speeds Outdoor Sound pressure Outdoor (h.) Power supply Running consumption Annual energy cons.- cooling mode (500h) - Directive 2002/31/CE Compressor type Refrigerant type Liquid pipe diameter Gas pipe diameter Max. pipe lenght (per indoor unit) Max. pipe lenght with gas additional charge Gas additional charge Max. height between units (Outdoor on top) Max. height between units (Indoor on top) Net weight Outdoor Net dimension Outdoor (H./W./D.) AER518DC Units n° kW kW BTU/h kcal/h ABCDEFG (kW/kW) m³/h n° dB(A) V/Ph/Hz kW kWh mm(inch") mm(inch") m m gr/m m m Kg mm Cooling 5,30 18.100 4.600 E 2,47 2,15 1.025 2 5,30 Heating 940 1 45 230/1/50 Rotary R407C 6,35(1/4") x 2 9,52(3/8") x 2 7,5 15 15 7 7 59 630x830x305 - - The technical data here indicated are in compliance with the European standard EN14511 - Directive 2002/31/EC w w w. a r g o c l i m a . c o m PRODUCT NAME Outdoor unit Features Connectable indoor units Max capacity of connected/operating indoor units 129 MULTISPLIT ON/OFF R407C improve your life Hi-wall AWR609C L AWR612C L INDOOR UNITS MATC HING TABLE Cassette Ducted Floor-ceiling ASR609C L ADR609C L AFR609C L ASR612C L ADR612C L FC R612C L AER 524 DC Dual Split air conditioner for cooling and dehumidification (DRY) mode Maximum cooling capacity 6,7 kW, divided into:- 2,6 kW for each xx9xx unit- 3,35 kW for each x12xx unit System with two independent refrigerant circuits Fully mixed matching possibility With a proper connection of the cassette or ducted indoor units it is possible to manage up to two groups of two rooms each or one single room with four air sendout points. Each Indoor unit is managed by its own remote control In case more indoor units are installed in the same room, it is possible to address every remote control to its own indoor unit only, so that to avoid any interference Single-phase power supply Auto restart after a power supply black out REMOTE CONTROL Over-pressure electronic protection of the compressor Double rotary compressor w w w. a r g o c l i m a . c o m Indoor units are the same used for single-split systems 130 PRODUCT NAME Outdoor unit Features Connectable indoor units Max. capacity of connected/operating indoor units Cooling/Heating capacity Energy label class E.E.R. / C.O.P. Air flowrate Outdoor (h.) Fan speeds Outdoor Sound pressure Outdoor (h.) Power supply Running consumption Annual energy cons.- cooling mode (500h) - Directive 2002/31/CE Compressor type Refrigerant type Liquid pipe diameter Gas pipe diameter Max. pipe lenght (per indoor unit) Max. pipe lenght with gas additional charge Gas additional charge Max. height between units (Outdoor on top) Max. height between units (Indoor on top) Net weight Outdoor Net dimension Outdoor (H./W./D.) AER524DC Units n° kW kW BTU/h kcal/h ABCDEFG (kW/kW) m³/h n° dB(A) V/Ph/Hz kW kWh mm(inch") mm(inch") m m gr/m m m Kg mm Cooling 6,70 22.900 5.760 E 2,53 2,65 1.325 2 6,70 Heating 980 2 (Auto) 47 230/1/50 Rotary R407C 6,35(1/4") x 2 12,7(1/2") x 2 7,5 20 25 7 7 67,5 835x850x305 - - The technical data here indicated are in compliance with the European standard EN14511 - Directive 2002/31/EC MULTISPLIT ON/OFF R407C Hi-wall AWR509DHL improve your life INDOOR UNITS MATC HING TABLE Cassette Ducted Floor-ceiling ASR509DHL ADR509DHL AFR509DHL AER 518 DH Dual-split cooling and heat pump air conditioner for cooling, dehumidification and heating mode. System with two independent refrigerant circuits 6,3 kW maximum heating capacity Fully mixed matching possibility With a proper connection of the cassette or ducted indoor units it is possible to manage up to two groups of two rooms each or one single room with four air sendout points. Each Indoor unit is managed by its own remote control In case more indoor units are installed in the same room, it is possible to address every remote control to its own indoor unit only, so that to avoid any interference Single-phase power supply Auto restart after a power supply black out REMOTE CONTROL Over-pressure electronic protection of the compressor Double rotary compressor Cooling/Heating capacity Energy label class E.E.R. / C.O.P. Air flowrate Outdoor (h.) Fan speeds Outdoor Sound pressure Outdoor (h.) Power supply Running consumption Annual energy cons.- cooling mode (500h) - Directive 2002/31/CE Compressor type Refrigerant type Liquid pipe diameter Gas pipe diameter Max. pipe lenght (per indoor unit) Max. pipe lenght with gas additional charge Gas additional charge Max. height between units (Outdoor on top) Max. height between units (Indoor on top) Net weight Outdoor Net dimension Outdoor (H./W./D.) AER518DH Units n° kW kW BTU/h kcal/h ABCDEFG (kW/kW) m³/h n° dB(A) V/Ph/Hz kW kWh mm(inch") mm(inch") m m gr/m m m Kg mm Cooling 4,70 4,70 16.100 4.040 G 2,16 2,18 1.090 2 940 1 45 230/1/50 Heating 6,30 6,30 21.500 5.420 C 3,23 1,95 - Rotary R407C 6,35(1/4") x 2 9,52(3/8") x 2 7,5 15 15 7 7 61 630x830x305 The technical data here indicated are in compliance with the European standard EN14511 - Directive 2002/31/EC w w w. a r g o c l i m a . c o m PRODUCT NAME Outdoor unit Features Connectable indoor units Max capacity of connected/operating indoor units 131 MULTISPLIT ON/OFF R407C improve your life Hi-wall AWR609C L INDOOR UNITS MATC HING TABLE Cassette Ducted Floor-ceiling ASR609C L ADR609C L AFR609C L AER 522 QC Three and Four split air conditioner for cooling and dehumidification (DRY) mode System with two independent refrigerant circuits, of which one is splitted on two indoor units Maximum cooling capacity 5,5 kW, divided into:- 2,5 kW on the first circuit- 1,5 kW on the first branch of the second circuit- 1,5 kW on the second branch of the second circuit To be matched to DKR5555C kit to get four-split systems Fully mixed matching possibility With a proper connection of the cassette or ducted indoor units it is possible to manage up to two groups of three rooms each or one single room with six air sendout points. Each Indoor unit is managed by its own remote control In case more indoor units are installed in the same room, it is possible to address every remote control to its own indoor unit only, so that to avoid any interference Single-phase power supply Auto restart after a power supply black out REMOTE CONTROL Over-pressure electronic protection of the compressor Double rotary compressor w w w. a r g o c l i m a . c o m Indoor units are the same used for single-split systems 132 PRODUCT NAME Outdoor unit Features Connectable indoor units Max. capacity of connected/operating indoor units Cooling/Heating capacity Energy label class E.E.R. / C.O.P. Air flowrate Outdoor (h.) Fan speeds Outdoor Sound pressure Outdoor (h.) Power supply Running consumption Annual energy cons.- cooling mode (500h) - Directive 2002/31/CE Compressor type Refrigerant type Liquid pipe diameter Gas pipe diameter Max. pipe lenght (per indoor unit) Max. pipe lenght with gas additional charge Gas additional charge Max. height between units (Outdoor on top) Max. height between units (Indoor on top) Net weight Outdoor Net dimension Outdoor (H./W./D.) AER522QC Units n° kW kW BTU/h kcal/h ABCDEFG (kW/kW) m³/h n° dB(A) V/Ph/Hz kW kWh mm(inch") mm(inch") m m gr/m m m Kg mm Cooling 5,50 18.800 4.730 D 2,75 3 5,50 1.410 1 47 230/1/50 Heating - 2,00 1.000 Rotary R407C 6,35(1/4") x 3 9,52(3/8") x 3 7,5 20 su A+B e 15 su C 15 7 7 61 630x830x305 The technical data here indicated are in compliance with the European standard EN14511 - Directive 2002/31/EC MULTISPLIT ON/OFF R407C Hi-wall AWR609C L AWR612C L AWR518C L improve your life INDOOR UNITS MATC HING TABLE Cassette Ducted Floor-ceiling ASR609C L ADR609C L AFR609C L ASR612C L ADR612C L FC R612C L ASR518C L ADR518C L FC R518C L AER 534 QC Three and Four split air conditioner for cooling and dehumidification (DRY) mode System with two independent refrigerant circuits, of which one is splitted on two indoor units Maximum cooling capacity 9,8 kW divided into:- 4,3 kW on the first circuit- 2,75 kW on the second circuit- 2,75 kW on the third circuit It can become a Four-split system by the kit DKR8585C Fully mixed matching possibilità With a proper connection of the cassette or ducted indoor units it is possible to manage up to two groups of four rooms each or one single room with eight air sendout points. Each Indoor unit is managed by its own remote control In case more indoor units are installed in the same room, it is possible to address every remote control to its own indoor unit only, so that to avoid any interference Single-phase power supply Auto restart after a power supply black out REMOTE CONTROL Over-pressure electronic protection of the compressor Double rotary compressor PRODUCT NAME Outdoor unit Features Connectable indoor units Max. capacity of connected/operating indoor units Cooling/Heating capacity Energy label class E.E.R. / C.O.P. Air flowrate Outdoor (h.) Fan speeds Outdoor Sound pressure Outdoor (h.) Power supply Running consumption Annual energy cons.- cooling mode (500h) - Directive 2002/31/CE Compressor type Refrigerant type Liquid pipe diameter Gas pipe diameter Max. pipe lenght (per indoor unit) Max. pipe lenght with gas additional charge Gas additional charge Max. height between units (Outdoor on top) Max. height between units (Indoor on top) Net weight Outdoor Net dimension Outdoor (H./W./D.) AER534QC Units n° kW kW BTU/h kcal/h ABCDEFG (kW/kW) m³/h n° dB(A) V/Ph/Hz kW kWh mm(inch") mm(inch") m m gr/m m m Kg mm Cooling Heating 3 (4 with additional kit) 9,80 9,80 33.500 8.430 E 2,42 1.700 2 (Auto) 47 230/1/50 4,05 2.025 Rotary R407C 6,35(1/4") x 3 9,52(3/8") x 2 + 12,7(1/2") 7,5 20 su A+B e 15 su C 15 7 7 108 1.235x940x340 The technical data here indicated are in compliance with the European standard EN14511 - Directive 2002/31/EC w w w. a r g o c l i m a . c o m Indoor units are the same used for single-split systems 133 w w w. a r g o c l i m a . c o m PA C K A G E / M U LT I PA C K A G E R 4 0 7 C improve your life PACKAGE CASSETTE - ON/OFF R407C improve your life ASR 425 HG Cassette straight cooling and heat pump air conditioner Automatic change-over between cooling and heating mode Special function during heat pump start-up and defrosting cycle toavoid cool air in environment Infrared remote control with 24h digital timer and full features control Wireless control Temperature sensor inside the remote control “Auto I Feel” feature, give you the best comfort conditions Night set back capability This air conditioner may be controlled by remote wired controller with configuration, diagnostic and weekly timer capabilities Dry function Tree speeds centrifugal fan by remote control Wired control Special system to avoid condensate dripping from air outlet ribs Four horizontal flap swinging or to be set on a fixed position by remote control Anti-mould and anti-bacteria washable filters Integrated pump for condensate discharge Possibility to have a connection for fresh air intake Double ways of air ducts in adjacent rooms through pre-drilled holes Weekly Timer Dinamic refrigerant control by microprocessor, electronic valve and fuzzy logic Auto restart after a power supply black out Over-pressure electronic protection of the compressor Wide range of operations:- cooling from -5°C to +45°C- heating from -15°C to +21°C PRODUCT NAME Indoor unit Outdoor unit Features Cooling/Heating capacity Energy label class E.E.R. / C.O.P. Air flowrate Indoor (h.m.l.) Dehumidification Fan speeds (Indoor / Outdoor) Sound pressure Indoor (h.m.l.) Sound pressure Outdoor (h.) Power supply Running consumption Annual energy cons.- cooling mode (500h) - Directive 2002/31/CE Compressor type Refrigerant type Liquid pipe diameter Gas pipe diameter Max. pipe lenght with gas standard charge Max. pipe lenght with gas additional charge Gas additional charge Max. height between units (Outdoor on top) Max. height between units (Indoor on top) Net weight Indoor (with grille) / Outdoor Net dimension Indoor (with grille) (H./W./D.) Net dimension Outdoor (H./W./D.) Units kW BTU/h kcal/h ABCDEFG (kW/kW) m3/h l/h n° dB(A) dB(A) V/Ph/Hz kW kWh mm(inch") mm(inch") m m gr/m m m Kg mm mm ASR425HG AER425SHLE Cooling Heating 7,30 8,00 25.000 27.000 6.280 6.880 E F 2,46 2,52 1.140-1.020-840 3,6 3 + Auto / 3 (Auto) 47-45-41 48 230/1/50 2,97 3,17 1.485 Rotary R407C 6,35(1/4") 15,88(5/8") 30 50 45 50 30 27/71 338x860x860 735x940x340 The technical data here indicated are in compliance with the European standard EN14511 - Directive 2002/31/EC w w w. a r g o c l i m a . c o m High efficiency rotary compressor 135 PACKAGE CASSETTE - ON/OFF R407C improve your life ASR 425 HG3 Cassette straight cooling and heat pump air conditioner Automatic change-over between cooling and heating mode Special function during heat pump start-up and defrosting cycle toavoid cool air in environment Infrared remote control with 24h digital timer and full features control Temperature sensor inside the remote control Wireless control “Auto I Feel” feature, give you the best comfort conditions Night set back capability This air conditioner may be controlled by remote wired controller with configuration, diagnostic and weekly timer capabilities Dry function Tree speeds centrifugal fan by remote control Special system to avoid condensate dripping from air outlet ribs Wired control Four horizontal flap swinging or to be set on a fixed position by remote control Anti-mould and anti-bacteria washable filters Integrated pump for condensate discharge Possibility to have a connection for fresh air intake Double ways of air ducts in adjacent rooms through pre-drilled holes Dinamic refrigerant control by microprocessor, electronic valve and fuzzy logic Weekly Timer Auto restart after a power supply black out Over-pressure electronic protection of the compressor Wide range of operations:- cooling from -5°C to +45°C- heating from -15°C to +21°C Three phase power supply 400/3N/50 w w w. a r g o c l i m a . c o m High efficiency rotary compressor 136 PRODUCT NAME Indoor unit Outdoor unit Features Cooling/Heating capacity Energy label class E.E.R. / C.O.P. Air flowrate Indoor (h.m.l.) Dehumidification Fan speeds (Indoor / Outdoor) Sound pressure Indoor (h.m.l.) Sound pressure Outdoor (h.) Power supply Running consumption Annual energy cons.- cooling mode (500h) - Directive 2002/31/CE Compressor type Refrigerant type Liquid pipe diameter Gas pipe diameter Max. pipe lenght with gas standard charge Max. pipe lenght with gas additional charge Gas additional charge Max. height between units (Outdoor on top) Max. height between units (Indoor on top) Net weight Indoor (with grille) / Outdoor Net dimension Indoor (with grille) (H./W./D.) Net dimension Outdoor (H./W./D.) Units kW BTU/h kcal/h ABCDEFG (kW/kW) m3/h l/h n° dB(A) dB(A) V/Ph/Hz kW kWh mm(inch") mm(inch") m m gr/m m m Kg mm mm ASR425HG AER425SHL3E Cooling Heating 7,30 8,00 25.000 27.000 6.280 6.880 E E 2,58 2,61 1.140-1.020-840 3,6 3 + Auto / 3 (Auto) 47-45-41 48 400/3/50 2,83 3,06 1.415 Rotary R407C 6,35(1/4") 15,88(5/8") 30 50 45 50 30 27/71 338x860x860 735x940x340 The technical data here indicated are in compliance with the European standard EN14511 - Directive 2002/31/EC PACKAGE CASSETTE - ON/OFF R407C improve your life ASR 436 HG3 Cassette straight cooling and heat pump air conditioner Automatic change-over between cooling and heating mode Special function during heat pump start-up and defrosting cycle toavoid cool air in environment Infrared remote control with 24h digital timer and full features control Temperature sensor inside the remote control Wireless control “Auto I Feel” feature, give you the best comfort conditions Night set back capability This air conditioner may be controlled by remote wired controller with configuration, diagnostic and weekly timer capabilities Dry function Tree speeds centrifugal fan by remote control Special system to avoid condensate dripping from air outlet ribs Wired control Four horizontal flap swinging or to be set on a fixed position by remote control Anti-mould and anti-bacteria washable filters Integrated pump for condensate discharge Possibility to have a connection for fresh air intake Double ways of air ducts in adjacent rooms through pre-drilled holes Dinamic refrigerant control by microprocessor, electronic valve and fuzzy logic Weekly Timer Auto restart after a power supply black out Over-pressure electronic protection of the compressor Wide range of operations:- cooling from -5°C to +45°C- heating from -15°C to +21°C Three phase power supply 400/3N/50 PRODUCT NAME Indoor unit Outdoor unit Features Cooling/Heating capacity Energy label class E.E.R. / C.O.P. Air flowrate Indoor (h.m.l.) Dehumidification Fan speeds (Indoor / Outdoor) Sound pressure Indoor (h.m.l.) Sound pressure Outdoor (h.) Power supply Running consumption Annual energy cons.- cooling mode (500h) - Directive 2002/31/CE Compressor type Refrigerant type Liquid pipe diameter Gas pipe diameter Max. pipe lenght with gas standard charge Max. pipe lenght with gas additional charge Gas additional charge Max. height between units (Outdoor on top) Max. height between units (Indoor on top) Net weight Indoor (with grille) / Outdoor Net dimension Indoor (with grille) (H./W./D.) Net dimension Outdoor (H./W./D.) Units kW BTU/h kcal/h ABCDEFG (kW/kW) m3/h l/h n° dB(A) dB(A) V/Ph/Hz kW kWh mm(inch") mm(inch") m m gr/m m m Kg mm mm ASR436HG AER436SHL3E Cooling Heating 10,60 11,40 36.000 39.000 9.120 9.800 D E 2,67 2,65 1.920-1.680-1.320 3,6 3 + Auto / 3 (Auto) 53-50-46 49 400/3/50 3,97 4,30 1.985 Scroll R407C 9,52(3/8") 19,05(3/4") 30 50 50 50 30 34/106 368x1.150x860 1.235x940x340 The technical data here indicated are in compliance with the European standard EN14511 - Directive 2002/31/EC w w w. a r g o c l i m a . c o m High efficiency rotary compressor 137 PACKAGE CASSETTE - ON/OFF R407C improve your life ASR 448 HG3 Cassette straight cooling and heat pump air conditioner Automatic change-over between cooling and heating mode Special function during heat pump start-up and defrosting cycle toavoid cool air in environment Infrared remote control with 24h digital timer and full features control Wireless control Temperature sensor inside the remote control “Auto I Feel” feature, give you the best comfort conditions Night set back capability This air conditioner may be controlled by remote wired controller with configuration, diagnostic and weekly timer capabilities Dry function Tree speeds centrifugal fan by remote control Wired control Special system to avoid condensate dripping from air outlet ribs Four horizontal flap swinging or to be set on a fixed position by remote control Anti-mould and anti-bacteria washable filters Integrated pump for condensate discharge Possibility to have a connection for fresh air intake Double ways of air ducts in adjacent rooms through pre-drilled holes Weekly Timer Dinamic refrigerant control by microprocessor, electronic valve and fuzzy logic Auto restart after a power supply black out Over-pressure electronic protection of the compressor Wide range of operations:- cooling from -5°C to +45°C- heating from -15°C to +21°C Three phase power supply 400/3N/50 w w w. a r g o c l i m a . c o m High efficiency rotary compressor 138 PRODUCT NAME Indoor unit Outdoor unit Features Cooling/Heating capacity Energy label class E.E.R. / C.O.P. Air flowrate Indoor (h.m.l.) Dehumidification Fan speeds (Indoor / Outdoor) Sound pressure Indoor (h.m.l.) Sound pressure Outdoor (h.) Power supply Running consumption Annual energy cons.- cooling mode (500h) - Directive 2002/31/CE Compressor type Refrigerant type Liquid pipe diameter Gas pipe diameter Max. pipe lenght with gas standard charge Max. pipe lenght with gas additional charge Gas additional charge Max. height between units (Outdoor on top) Max. height between units (Indoor on top) Net weight Indoor (with grille) / Outdoor Net dimension Indoor (with grille) (H./W./D.) Net dimension Outdoor (H./W./D.) Units kW BTU/h kcal/h ABCDEFG (kW/kW) m3/h l/h n° dB(A) dB(A) V/Ph/Hz kW kWh mm(inch") mm(inch") m m gr/m m m Kg mm mm ASR448HG AER448SHL3E Cooling Heating 12,60 15,30 43.000 52.200 10.840 13.160 2,87 2,90 1.920-1.680-1.320 6,3 3 + Auto / 3 (Auto) 53-50-46 50 400/3/50 4,39 5,27 Scroll R407C 9,52(3/8") 19,05(3/4") 30 50 50 50 30 34/106 368x1.150x860 1.235x940x340 The technical data here indicated are in compliance with the European standard EN14511 - Directive 2002/31/EC PACKAGE DUCTED - ON/OFF R407C improve your life ADR 425 HL Ducted straight cooling and heat pump air conditioner Three-way duct connection Automatic change-over between cooling and heating mode Special function during heat pump start-up and defrosting cycle toavoid cool air in environment This air conditioner may be controlled by remote wired controller with configuration, diagnostic and weekly timer capabilities Temperature sensor inside the remote control “Auto I Feel” feature, give you the best comfort conditions Night set back capability Dry function Wired control Tree speeds centrifugal fan by remote control and feature to increase speed/pressure (from 5 to 10 mm c.a.) Integrated pump for condensate discharge Connection for fresh air intake by optional kit with anti-mould / anti-bacteria filter and the facility to access directly to the internal components for maintenance activities Dinamic refrigerant control by microprocessor, electronic valve and fuzzy logic Weekly Timer Auto restart after a power supply black out Over-pressure electronic protection of the compressor Wide range of operations:- cooling from -5°C to +45°C- heating from -15°C to +21°C PRODUCT NAME Indoor unit Outdoor unit Features Cooling/Heating capacity Energy label class E.E.R. / C.O.P. Air flowrate (h.m.l.) Dehumidification External static pressure (min-max) Fan speeds (Indoor / Outdoor) Sound power Indoor (h.m.l.) Sound pressure Indoor (h.m.l.) at discharge plenum connection Sound pressure Indoor at ducts exit Sound pressure Outdoor (h.) Power supply Running consumption Annual energy cons.- cooling mode (500h) - Directive 2002/31/CE Compressor type Refrigerant type Liquid pipe diameter Gas pipe diameter Max. pipe lenght with gas standard charge Max. pipe lenght with gas additional charge Gas additional charge Max. height between units (Outdoor on top) Max. height between units (Indoor on top) Ducts diameter Net weight Indoor / Outdoor Net dimension Indoor (H./W./D.) Net dimension Outdoor (H./W./D.) Units kW BTU/h kcal/h ABCDEFG (kW/kW) m3/h l/h mm W.G. n° dB(A) dB(A) dB(A) dB(A) V/Ph/Hz kW kWh mm(inch") mm(inch") m m gr/m m m mm Kg mm mm ADR425H AER425SHLE Cooling Heating 7,30 8,60 25.000 29.300 6.280 7.410 E E 2,48 2,70 1.080-900-780 3,5 5,1-9,4 3 + Auto / 3 (Auto) 56-52-49 47-43-40 < 20 48 230/1/50 2,940 3,190 1.470 Rotary R407C 6,35(1/4") 15,88(5/8") 30 50 45 50 30 200 32/71 310x1.000x630 735x940x340 The technical data here indicated are in compliance with the European standard EN14511 - Directive 2002/31/EC w w w. a r g o c l i m a . c o m High efficiency rotary compressor 139 PACKAGE DUCTED - ON/OFF R407C improve your life ADR 425/436/448 HL3 Ducted straight cooling and heat pump air conditioner Three/four-way duct connection Automatic change-over between cooling and heating mode Special function during heat pump start-up and defrosting cycle toavoid cool air in environment This air conditioner may be controlled by remote wired controller with configuration, diagnostic and weekly timer capabilities Temperature sensor inside the remote control “Auto I Feel” feature, give you the best comfort conditions Night set back capability Wired control Dry function Tree speeds centrifugal fan by remote control and feature to increase speed/pressure (from 5 to 10 mm c.a.) Integrated pump for condensate discharge Connection for fresh air intake by optional kit with anti-mould / anti-bacteria filter and the facility to access directly to the internal components for maintenance activities Weekly Timer Dinamic refrigerant control by microprocessor, electronic valve and fuzzy logic Auto restart after a power supply black out Over-pressure electronic protection of the compressor Wide range of operations:- cooling from -5°C to +45°C- heating from -15°C to +21°C Three phase power supply 400/3N/50 w w w. a r g o c l i m a . c o m High efficiency rotary compressor 140 PRODUCT NAME Indoor unit Outdoor unit Features Cooling/Heating capacity Units kW BTU/h kcal/h ABCDEFG (kW/kW) m3/h l/h mm W.G. n° dB(A) dB(A) dB(A) dB(A) V/Ph/Hz kW Energy label class E.E.R. / C.O.P. Air flowrate (h.m.l.) Dehumidification External static pressure (min-max) Fan speeds (Indoor / Outdoor) Sound power Indoor (h.m.l.) Sound pressure Indoor (h.m.l.) at plenum connectio Sound pressure Indoor at ducts exit Sound pressure Outdoor (h.) Power supply Running consumption Annual energy cons.- cooling mode (500h) kWh Directive 2002/31/CE Compressor type Refrigerant type Liquid pipe diameter mm(inch") Gas pipe diameter mm(inch") Max. pipe lenght with gas standard charge m Max. pipe lenght with gas additional charge m Gas additional charge gr/m Max. height between units (Outdoor on top) m Max. height between units (Indoor on top) m Ducts diameter mm Net weight Indoor / Outdoor Kg Net dimension Indoor (H./W./D.) mm Net dimension Outdoor (H./W./D.) mm ADR425H AER425SHL3E Cooling Heating 7,30 8,60 25.000 29.300 6.280 7.410 D E 2,61 2,76 1.080-900-780 3,5 5,1-9,4 3 + Auto / 3 (Auto) 56-52-49 47-43-40 < 20 48 400/3/50 2,800 3,120 1.400 - Rotary R407C 6,35(1/4") 15,88(5/8") 30 50 45 50 30 200 32/71 310x1.000x630 735x940x340 ADR436H AER436SHL3E Cooling Heating 10,60 12,50 36.000 42.700 9.120 10.750 E E 2,59 2,80 1.800-1.560-1.260 4,2 8,1-12,4 3 + Auto / 3 (Auto) 60-55-53 51-46-44 < 20 49 400/3/50 4,090 4,470 2.045 - Scroll R407C 9,52(3/8") 19,05(3/4") 30 50 50 50 30 200 47/106 310x1.480x630 1.235x940x340 ADR448H AER448SHL3E Cooling Heating 12,60 15,30 43.000 52.200 10.840 13.160 2,65 2,75 1.980-1.800-1.500 5,4 8-11,5 3 + Auto / 3 (Auto) 62-59-55 53-50-46 < 20 50 400/3/50 4,760 5,570 - - Scroll R407C 9,52(3/8") 19,05(3/4") 30 50 50 50 30 200 47/108 310x1.480x630 1.235x940x340 The technical data here indicated are in compliance with the European standard EN14511 - Directive 2002/31/EC PACKAGE CEILING - ON/OFF R407C improve your life ACR 425 HL Ceiling straight cooling and heat pump air conditioner Wireless control Automatic change-over between cooling and heating mode Special function during heat pump start-up and defrosting cycle toavoid cool air in environment Infrared remote control with 24h digital timer and full features control Temperature sensor inside the remote control “Auto I Feel” feature, give you the best comfort conditions Wired control Night set back capability This air conditioner may be controlled by remote wired controller with configuration, diagnostic and weekly timer capabilities Dry function Tree speeds centrifugal fan by remote control Horizontal flap swinging or to be set on a fixed position by remote control Anti-mould and anti-bacteria washable filters Weekly Timer Possibility to have a connection for fresh air intake Dinamic refrigerant control by microprocessor, electronic valve and fuzzy logic Auto restart after a power supply black out Over-pressure electronic protection of the compressor Wide range of operations:- cooling from -5°C to +45°C- heating from -15°C to +21°C PRODUCT NAME Indoor unit Outdoor unit Features Cooling/Heating capacity Energy label class E.E.R. / C.O.P. Air flowrate Indoor (h.m.l.) Dehumidification Fan speeds (Indoor / Outdoor) Sound pressure Indoor (h.m.l.) Sound pressure Outdoor (h.) Power supply Running consumption Annual energy cons.- cooling mode (500h) - Directive 2002/31/CE Compressor type Refrigerant type Liquid pipe diameter Gas pipe diameter Max. pipe lenght with gas standard charge Max. pipe lenght with gas additional charge Gas additional charge Max. height between units (Outdoor on top) Max. height between units (Indoor on top) Net weight Indoor / Outdoor Net dimension Indoor (H./W./D.) Net dimension Outdoor (H./W./D.) Units kW BTU/h kcal/h ABCDEFG (kW/kW) m3/h l/h n° dB(A) dB(A) V/Ph/Hz kW kWh mm(inch") mm(inch") m m gr/m m m Kg mm mm ACR425H AER425SHLE Cooling Heating 7,30 8,60 25.000 29.300 6.280 7.410 E E 2,57 2,78 1.080-960-840 3,5 3 + Auto / 3 (Auto) 48-46-43 48 230/1/50 2,840 3,090 1.420 Rotary R407C 6,35(1/4") 15,88(5/8") 30 50 45 50 30 26/71 190x1.300x670 735x940x340 The technical data here indicated are in compliance with the European standard EN14511 - Directive 2002/31/EC w w w. a r g o c l i m a . c o m High efficiency scroll compressor 141 PACKAGE CEILING - ON/OFF R407C improve your life ACR 425/436/448 HL3 Ceiling straight cooling and heat pump air conditioner Automatic change-over between cooling and heating mode Wireless control Special function during heat pump start-up and defrosting cycle toavoid cool air in environment Infrared remote control with 24h digital timer and full features control Temperature sensor inside the remote control “Auto I Feel” feature, give you the best comfort conditions Night set back capability Wired control This air conditioner may be controlled by remote wired controller with configuration, diagnostic and weekly timer capabilities Dry function Tree speeds centrifugal fan by remote control Horizontal flap swinging or to be set on a fixed position by remote control Anti-mould and anti-bacteria washable filters Possibility to have a connection for fresh air intake Weekly Timer Dinamic refrigerant control by microprocessor, electronic valve and fuzzy logic Auto restart after a power supply black out Over-pressure electronic protection of the compressor Wide range of operations:- cooling from -5°C to +45°C- heating from -15°C to +21°C Three phase power supply 400/3N/50 w w w. a r g o c l i m a . c o m High efficiency scroll compressor 142 PRODUCT NAME Indoor unit Outdoor unit Features Cooling/Heating capacity Energy label class E.E.R. / C.O.P. Air flowrate Indoor (h.m.l.) Dehumidification Fan speeds (Indoor / Outdoor) Sound pressure Indoor (h.m.l.) Sound pressure Outdoor (h.) Power supply Running consumption Annual energy cons.- cooling mode (500h) Directive 2002/31/CE Compressor type Refrigerant type Liquid pipe diameter Gas pipe diameter Max. pipe lenght with gas standard charge Max. pipe lenght with gas additional charge Gas additional charge Max. height between units (Outdoor on top) Max. height between units (Indoor on top) Net weight Indoor / Outdoor Net dimension Indoor (H./W./D.) Net dimension Outdoor (H./W./D.) Units kW BTU/h kcal/h ABCDEFG (kW/kW) m3/h l/h n° dB(A) dB(A) V/Ph/Hz kW kWh mm(inch") mm(inch") m m gr/m m m Kg mm mm ACR425H AER425SHL3E Cooling Heating 7,30 8,60 25.000 29.300 6.280 7.410 D D 2,70 2,85 1.080-960-840 3,5 3 + Auto / 3 (Auto) 48-46-43 48 400/3/50 2,700 3,020 1.350 - Rotary R407C 6,35(1/4") 15,88(5/8") 30 50 45 50 30 26/71 190x1.300x670 735x940x340 ACR436H AER436SHL3E Cooling Heating 10,60 12,50 36.000 42.700 9.120 10.750 D D 2,67 2,88 1.800-1.560-1.200 4,7 3 + Auto / 3 (Auto) 52-50-45 49 400/3/50 3,970 4,340 1.985 - Scroll R407C 9,52(3/8") 19,05(3/4") 30 50 50 50 30 38/106 240x1.575x670 1.235x940x340 ACR448H AER448SHL3E Cooling Heating 12,60 15,30 43.000 52.200 10.840 13.160 2,72 2,81 1.920-1.680-1.320 5,9 3 + Auto / 3 (Auto) 53-50-46 50 400/3/50 4,640 5,450 - - Scroll R407C 9,52(3/8") 19,05(3/4") 30 50 50 50 30 38/108 240x1.575x670 1.235x940x340 The technical data here indicated are in compliance with the European standard EN14511 - Directive 2002/31/EC MULTIPACKAGE - ON/OFF R407C improve your life MULTIPACKAGE E.R.F. Cooling and heat pump air conditioners with dehumidification mode available (DRY function), for open space solutions (AW serie) Size: from 7 to 14 kW Outdoor unit able to be matched with two, three and four indoor units Operated by wired remote controls which can be matched with weekly timer control and sytem control (SYS), or with infrared remote controls (AS/AC/FC) (AS serie) Possibility to connect the wired remote control with one single master control E.R.F (Electronic Refrigerant Flow) control for a continuous regulation of the refrigerant flowrate to the indoor units. It is based on an electronc valve and fuzzy logic microprocessor in any single indoor unit Indoor units type:- Underceiling (AC)- Floor/Ceiling (FC)- Cassette (AS)- Two, three and four ducts ducted type (AD)- Wall (AW) Automatic cooling/heating changeover. (AD serie) Single-phase (7kW size) or three-phase (all sizes) power supply. Compressor protection against overpressure and automatic restart after power supply interruption Great maximum distances and height differences between outdoor and indoor units for easy installation. Scroll and rotary compressors (FC serie ) Wireless control (AC serie) Wired control Weekly Timer w w w. a r g o c l i m a . c o m Wide range of outdoor air temperature (from -15°C to +43°C) Cluster controller 143 MULTIPACKAGE - ON/OFF R407C improve your life MULTIPACKAGE E.R.F. Indoor units matching according to following rules: 1) Total cooling nominal capacity of the indoor units must be comprehended between 93% and 107% of the outdoor unit capacity 2) When the total nominal capacity of the indoor units exceeds 100% of te outdoor unit capacity, the actual cooling and heating capacity is anyway the one given by the outdoor unit 3) MultiPackage system controls allow the simultaneous operation only. MultiPackage systems are designed for Open Space solutions, i.e. hotel halls, conference rooms, big shops or offices, etc. ) 4) Remote controls can be wired or wireless. Wireless systems allow up to 3 different addresses 5) Refrigerant circuit by dedicated copper distribution joint kits. N.B. Check the accessory list at section multiset VRF R407C Outdoor units w w w. a r g o c l i m a . c o m AER425SHLE AER425SHL3E 144 System com binations Single type Tw in type Single type Tw in type AER436SHL3E Triple type Quartet type Single type Tw in type AER448SHL3E Triple type Quartet type Indoor units ASR425H-ASR425HG/ACR425H/ADR425H ASR412VHG - FCR412VHG - ADR412VHG-AWR412VH ASR436H-ASR436HG/ACR436H/ADR436H ASR418VHG - FCR418VHG - ADR418VHG-AWR418VH ASR412VHG - FCR412VHG - ADR412VHG-AWR412VH (ASR/FCR/ADR418VHG - AWR418VH x 1) + (ASR409VHG - FCR409VHG ADR409VHG-AWR409VH x 2) ASR409VHG - FCR409VHG - ADR409VHG - AWR409VH ASR448H-ASR448HG/ACR448H/ADR448H ASR425H-ASR425HG/ACR425H/ADR425H (ASR436H-ASR436HG/ACR436H/ADR436H x 1)+ASR/FCR/ADR412VHGAWR412VH x 1) (ASR/-FCR/ADR418VHG - AWR418VH x 2) + (ASR409VHG - FCR409VHG ADR409VHG-AWR409VH x 1) (ASR/-FCR/ADR418VHG - AWR418VH x 2) + (ASR412VHG - FCR412VHG ADR412VHG-AWR412VH x 1) ASR425HG-ASR425H/ ACR425H / ADR425H-ADR425HG x 1) + (ASR/ FCR/ADR412VHG - AWR412VH x 2) ASR412VHG - FCR412VHG - ADR412VHG-AWR412VH (ASR/-FCR/ADR418VHG - AWR418VH x 1) + (ASR409VHG - FCR409VHG ADR409VHG-AWR409VH x 3) no. units x1 x2 x1 x2 x3 (1x18+2x9) x4 x1 x 2 (1x36 + 1x12) (2x18+1x9) (2x18+1x12) (1x25+2x12) x4 (1x18+3x9) M U LT I S E T V. R . F. R 4 0 7 C w w w. a r g o c l i m a . c o m improve your life MULTISET V.R.F. - R407C improve your life MULTISET Multiset is a variable refrigerant flow (VRF) which complies with European regulations and uses. The range of condensing units is made by three heat pump models from 14 up to 31,5 kW (5,8 to 10 HP). Multiset controls the flowrate of the refrigerant sent into the circuit by an exclusive compressor control technology which gets same performance and results of inverters' one, but without using inverter systems. The operating range allows application with outdoor temperatures starting from -5°C (cooling mode), and -15°C (heating mode). The indoor units which can be matched (from 6 up to 13 according to the outdoor unit) are able to satisfy all the applications' need. Cassette, ducted, wall and ceiling and ceiling and floorceiling models are available. w w w. a r g o c l i m a . c o m The data network connections between indoor and outdoor 146 units is based on a simple and easy to install "two shielded wiring cable" without polarization. By this local area network the building manager, installer and/or field engineering support, may take from a single access point the control of diagnostics data, select and setting any indoor and outdoor parameter. MULTISET V.R.F. - R407C improve your life MULTISET The control of the performance is ensured by the contemporary action of the Power Controlled Compressor, refrigerant flow electronic valves installed in each indoor unit and external bypass valve. The AER 448 VH model uses one PCC compressor only, while the mdels AER 470 VH and AER 490 The Power Controlled Compressor is made by two cylinders which are connected one to each other by three by-pass, through which the refrigerant flowrate is controlled by three valves. Every single by-pass reduces 25% the maximum capacity when it is open. There are therefore 4 power steps available: 25% - 50% - 75% and 100% (when all the by-pass w w w. a r g o c l i m a . c o m VH use one PCC compressor and one standard compressor. valves are closed). 147 MULTISET V.R.F. - R407C improve your life MULTISET One of the typical features of the Argo VRF system is the maximum length of the piping in the refrigerant circuit and the height difference between outdoor and indoor units. The refrigerant circuits can reach maximum lengths up to 100 linear meters (125 equivalent meters) while the height difference between outdoor and indoor units can arrive up to 50m. w w w. a r g o c l i m a . c o m Max height difference 148 Max distances (m) Outdoor unit on the top Indoor unit on the top between indoor units Max. tubing lenght AER448VH AER470VH AER490VH 40 50 50 30 30 30 15 15 15 70 100 100 MULTISET V.R.F. - R407C improve your life MULTISET VRF Multiset is provided with a powerful design software (on Windows - 32 bit). The CAD module include a full features and characteristics of indoor / outdoor units, local and remote controller, accessories, refrigerant distributors…. The thermal design system is available also on Argo website (www.argoclima.com), both for download to use on a personal computer and for on-line usage. This design system allows a correct and precise evaluation of the thermal load of a room, calculated taking into account all the different parameters. w w w. a r g o c l i m a . c o m Project design in one single operation system is made much easier and can issue a PDF standard document. 149 MULTISET V.R.F. - R407C improve your life AER 448 VH PRODUCT NAME Features Cooling/Heating capacity w w w. a r g o c l i m a . c o m E.E.R. / C.O.P. Air flowrate (h.) Sound pressure (h.) Power supply Running consumption Compressor type Refrigerant type Liquid pipe diameter Gas pipe diameter Max. pipe lenght with gas standard charge Gas standard charge Gas additional charge Max. height between units (Outdoor on top) Max. height between units (Indoor on top) Net weight Net dimension (H./W./D.) 150 AER448VH Units kW BTU/h kcal/h (kW/kW) m³/h dB(A) V/Ph/Hz kW mm(inch") mm(inch") m Kg gr/m m m Kg mm Cooling 14,00 47.800 12.040 2,50 5.040 49 400/3N/50 Heating 16,00 54.500 13.760 3,04 5,61 5,27 Rotary (hermetic)-Power Control R407C 9,52(3/8") 19,05(3,4") 70 3,6 75 40 30 120 1.235x940x340 MULTISET V.R.F. - R407C improve your life AER 470 VH Cooling/Heating capacity E.E.R. / C.O.P. Air flowrate (h.) Sound pressure (h.) Power supply Running consumption Compressor type Refrigerant type Liquid pipe diameter Gas pipe diameter Max. pipe lenght with gas standard charge Gas standard charge Gas additional charge Max. height between units (Outdoor on top) Max. height between units (Indoor on top) Net weight Net dimension (H./W./D.) AER470VH Units kW BTU/h kcal/h (kW/kW) m³/h dB(A) V/Ph/Hz kW mm(inch") mm(inch") m Kg gr/m m m Kg mm Cooling 22,40 76.400 19.270 2,36 9.300 52 400/3N/50 Heating 25,00 85.300 21.500 2,92 9,50 8,57 Double rotary (hermetic) - Super Power Control R407C 12,7(1/2") 25,4(1") 100 9,5 125 50 30 231 1.218x883x883 w w w. a r g o c l i m a . c o m PRODUCT NAME Features 151 MULTISET V.R.F. - R407C improve your life AER 490 VH PRODUCT NAME Features Cooling/Heating capacity w w w. a r g o c l i m a . c o m E.E.R. / C.O.P. Air flowrate (h.) Sound pressure (h.) Power supply Running consumption Compressor type Refrigerant type Liquid pipe diameter Gas pipe diameter Max. pipe lenght with gas standard charge Gas standard charge Gas additional charge Max. height between units (Outdoor on top) Max. height between units (Indoor on top) Net weight Net dimension (H./W./D.) 152 AER490VH Units kW BTU/h kcal/h (kW/kW) m³/h dB(A) V/Ph/Hz kW mm(inch") mm(inch") m Kg gr/m m m Kg mm Cooling 28,00 95.500 24.080 2,46 9.000 52 400/3N/50 Heating 31,50 107.500 27.090 2,97 11,40 10,60 Double rotary (hermetic) - Super Power Control R407C 12,7(1/2") 28,58(1-1/8") 100 11 125 50 30 243 1.218x883x883 MULTISET V.R.F. - R407C improve your life ASR 409-412-418 VHG Cassette straight cooling and heat pump air conditioner Automatic change-over between cooling and heating mode Special function during heat pump start-up and defrosting cycle toavoid cool air in environment Infrared remote control with 24h digital timer and full features control Temperature sensor inside the remote control “Auto I Feel” feature, give you the best comfort conditions Night set back capability This air conditioner may be controlled by remote wired controller with configuration, diagnostic and weekly timer capabilities Dry function Tree speeds centrifugal fan by remote control Four horizontal flap swinging or to be set on a fixed position by remote control Anti-mould and anti-bacteria washable filters Integrated pump for condensate discharge Possibility to have a connection for fresh air intake Double ways of air ducts in adjacent rooms through pre-drilled holes PRODUCT NAME Features Cooling/Heating capacity Air flowrate Indoor (h.m.l.) Dehumidification Sound pressure Indoor (h.m.l.) Power supply Running consumption Refrigerant type Liquid pipe diameter Gas pipe diameter Net weight Indoor / grille Net dimension Indoor (H./W./D.) Net dimension grille (H./W./D.) Units kW BTU/h kcal/h m3/h l/h dB(A) V/Ph/Hz kW mm(inch") mm(inch") Kg mm mm ASR409VHG Cooling Heating 2,80 3,20 9.600 11.000 2.410 2.760 700-600-500 0,5 43-39-36 230/1/50 0,087 R407C 9,52(3/8") 12,7(1/2") 16,5/2,5 273x575x575 64x730x730 ASR412VHG Cooling Heating 3,60 4,20 12.300 14.300 3.100 3.610 700-600-500 1 43-39-36 230/1/50 0,087 R407C 9,52(3/8") 12,7(1/2") 16,5/2,5 273x575x575 64x730x730 ASR418VHG Cooling Heating 5,60 6,30 19.100 21.500 4.820 5.420 750-630-530 2,3 44-39-36 230/1/50 0,087 R407C 9,52(3/8") 15,88(5/8") 18/2,5 273x575x575 64x730x730 w w w. a r g o c l i m a . c o m Dinamic refrigerant control by microprocessor, electronic valve and fuzzy logic 153 MULTISET V.R.F. - R407C improve your life ASR 425-436-448 HG Cassette straight cooling and heat pump air conditioner Automatic change-over between cooling and heating mode Special function during heat pump start-up and defrosting cycle toavoid cool air in environment Infrared remote control with 24h digital timer and full features control Temperature sensor inside the remote control “Auto I Feel” feature, give you the best comfort conditions Night set back capability This air conditioner may be controlled by remote wired controller with configuration, diagnostic and weekly timer capabilities Dry function Tree speeds centrifugal fan by remote control Special system to avoid condensate dripping from air outlet ribs Four horizontal flap swinging or to be set on a fixed position by remote control Anti-mould and anti-bacteria washable filters Integrated pump for condensate discharge Possibility to have a connection for fresh air intake Double ways of air ducts in adjacent rooms through pre-drilled holes w w w. a r g o c l i m a . c o m Dinamic refrigerant control by microprocessor, electronic valve and fuzzy logic 154 PRODUCT NAME Features Cooling/Heating capacity Air flowrate Indoor (h.m.l.) Dehumidification Sound pressure Indoor (h.m.l.) Power supply Running consumption Refrigerant type Liquid pipe diameter Gas pipe diameter Net weight Indoor with grille Net dimension Indoor (with grille) (H./W./D.) Net dimension grille (H./W./D.) Units kW BTU/h kcal/h m3/h l/h dB(A) V/Ph/Hz kW mm(inch") mm(inch") Kg mm mm ASR425HG Cooling Heating 7,30 8,00 25.000 27.000 6.280 6.880 1.140-1.020-840 3,6 47-45-41 230/1/50 0,14 0,09 R407C 6,35(1/4") 15,88(5/8") 27 338x860x860 30x860x860 ASR436HG Cooling Heating 10,60 11,40 36.000 39.000 9.120 9.800 1.920-1.680-1.320 4,6 53-50-46 230/1/50 0,21 0,15 R407C 9,52(3/8") 19,05(3/4") 34 368x1.150x860 30x1.150x860 ASR448HG Cooling Heating 14,00 16,00 47.800 54.600 9.120 9.800 1.920-1.680-1.320 6,3 53-50-46 230/1/50 0,21 0,15 R407C 9,52(3/8") 19,05(3/4") 34 368x1.150x860 30x1.150x860 MULTISET V.R.F. - R407C improve your life ACR 425-436-448 H Ceiling straight cooling and heat pump air conditioner Automatic change-over between cooling and heating mode Special function during heat pump start-up and defrosting cycle toavoid cool air in environment Infrared remote control with 24h digital timer and full features control Temperature sensor inside the remote control “Auto I Feel” feature, give you the best comfort conditions Night set back capability This air conditioner may be controlled by remote wired controller with configuration, diagnostic and weekly timer capabilities Dry function Tree speeds centrifugal fan by remote control Horizontal flap swinging or to be set on a fixed position by remote control Anti-mould and anti-bacteria washable filters Possibility to have a connection for fresh air intake PRODUCT NAME Features Cooling/Heating capacity Air flowrate Indoor (h.m.l.) Dehumidification Sound pressure Indoor (h.m.l.) Power supply Running consumption Refrigerant type Liquid pipe diameter Gas pipe diameter Net weight Indoor Net dimension Indoor (H./W./D.) Units kW BTU/h kcal/h m3/h l/h dB(A) V/Ph/Hz kW mm(inch") mm(inch") Kg mm ACR425H Cooling Heating 7,30 8,00 25.000 27.000 6.280 6.880 1.080-960-840 3,5 48-46-43 230/1/50 0,095 0,075 R407C 6,35(1/4") 15,88(5/8") 26 190x1.300x670 ACR436H Cooling Heating 10,60 11,40 36.000 39.000 9.120 9.800 1.800-1.560-1.200 4,7 52-50-45 230/1/50 0,210 0,190 R407C 9,52(3/8") 19,05(3/4") 38 240x1.575x670 ACR448H Cooling Heating 14,00 16,00 47.800 54.600 12.040 13.760 1.920-1.680-1.320 7 53-50-46 230/1/50 0,210 0,190 R407C 9,52(3/8") 19,05(3/4") 38 240x1.575x670 w w w. a r g o c l i m a . c o m Dinamic refrigerant control by microprocessor, electronic valve and fuzzy logic 155 MULTISET V.R.F. - R407C improve your life ADR 409-412-418 VHG Ducted straight cooling and heat pump air conditioner with optional two ways air channel Automatic change-over between cooling and heating mode Special function during heat pump start-up and defrosting cycle to avoid cool air in environment This air conditioner may be controlled by remote wired controller with configuration, diagnostic and weekly timer capabilities Temperature sensor inside the remote control “Auto I Feel” feature, give you the best comfort conditions Night set back capability Dry function Tree speeds centrifugal fan by remote control and feature to increasespeed/pressure (from 5 to 7 mm c.a.) Anti-mould and anti-bacteria washable filters Integrated pump for condensate discharge w w w. a r g o c l i m a . c o m Dinamic refrigerant control by microprocessor, electronic valve and fuzzy logic 156 PRODUCT NAME Features Cooling/Heating capacity Air flowrate (h.m.l.) Dehumidification External static pressure (min-max) Fan speeds Sound power Indoor (h.m.l.) Sound pressure Indoor (h.m.l.) at discharge plenum connection Sound pressure Indoor at ducts exit Power supply Running consumption Refrigerant type Liquid pipe diameter Gas pipe diameter Duct diameter of the 2-way discharge plenum (optional) Net weight Indoor / Indoor with plenum Net dimension Indoor (H./W./D.) Net dimension Indoor with plenum (H./W./D.) Units kW BTU/h kcal/h m3/h l/h mm W.G. n° dB(A) ADR409VHG Cooling Heating 2,80 3,20 9.600 11.000 2.410 2.760 600-510-440 1 5-7 3 + Auto 54-52-49 ADR412VHG Cooling Heating 3,60 4,20 12.300 14.400 3.100 3.610 600-510-440 1,8 5-7 3 + Auto 54-52-49 ADR418VHG Cooling Heating 5,60 6,30 19.100 21.500 4.820 5.420 875-600-400 2,3 5-7 3 + Auto 54-47-42 dB(A) 45-43-40 45-43-40 45-38-33 dB(A) V/Ph/Hz kW < 20 230/1/50 < 20 230/1/50 < 20 230/1/50 mm(inch") mm(inch") 0,125 0,109 R407C 9,52(3/8") 12,7(1/2") 0,125 0,109 R407C 9,52(3/8") 12,7(1/2") 0,138 0,138 R407C 9,52(3/8") 15,88(5/8") mm 200 200 200 Kg mm mm 30/36 266x926x571 266x926x771 30/36 266x926x571 266x926x771 35/42,5 266x1.132x571 266x1.132x871 MULTISET V.R.F. - R407C improve your life ADR 425-436-448 H Ducted straight cooling and heat pump air conditioner Four-way duct connection Automatic change-over between cooling and heating mode Special function during heat pump start-up and defrosting cycle toavoid cool air in environment This air conditioner may be controlled by remote wired controller with configuration, diagnostic and weekly timer capabilities Temperature sensor inside the remote control “Auto I Feel” feature, give you the best comfort conditions Night set back capability Dry function Tree speeds centrifugal fan by remote control and feature to increase speed/pressure (from 5 to 10 mm c.a.) Integrated pump for condensate discharge Connection for fresh air intake by optional kit with anti-mould / anti-bacteria filter and the facility to access directly to the internal components for maintenance activities PRODUCT NAME Features Cooling/Heating capacity Air flowrate (h.m.l.) Dehumidification External static pressure (min-max) Fan speeds Sound power Indoor (h.m.l.) Sound pressure Indoor (h.m.l.) at discharge plenum connection Sound pressure Indoor at ducts exit Power supply Running consumption Refrigerant type Liquid pipe diameter Gas pipe diameter Ducts diameter Net weight Indoor Net dimension Indoor (H./W./D.) Units kW BTU/h kcal/h m3/h l/h mm W.G. n° dB(A) ADR425H Cooling Heating 7,30 8,00 25.000 27.000 6.280 6.880 1.080-900-780 3,5 5-10 3 + Auto 56-52-49 ADR436H Cooling Heating 10,60 11,40 36.000 39.000 9.120 9.800 1.800-1.560-1.260 4,2 7-12 3 + Auto 60-55-53 ADR448H Cooling Heating 14,00 16,00 47.800 54.600 12.040 13.760 1.980-1.800-1.500 6,6 7-12 3 + Auto 62-59-55 dB(A) 47-43-40 51-46-44 53-50-46 dB(A) V/Ph/Hz kW < 20 230/1/50 < 20 230/1/50 < 20 230/1/50 mm(inch") mm(inch") mm Kg mm 0,195 0,183 R407C 6,35(1/4") 15,88(5/8") 200 32 310x1.000x630 0,327 0,315 R407C 9,52(3/8") 19,05(3/4") 200 47 310x1.480x630 0,325 0,313 R407C 9,52(3/8") 19,05(3/4") 200 47 310x1.480x630 w w w. a r g o c l i m a . c o m Dinamic refrigerant control by microprocessor, electronic valve and fuzzy logic 157 MULTISET V.R.F. - R407C improve your life FCR 409-412-418 VHG Floor/Ceiling straight cooling and heat pump air conditioner Automatic change-over between cooling and heating mode Special function during heat pump start-up and defrosting cycle toavoid cool air in environment Infrared remote control with 24h digital timer and full features control Temperature sensor inside the remote control “Auto I Feel” feature, give you the best comfort conditions This air conditioner may be controlled by remote wired controller with configuration, diagnostic and weekly timer capabilities Dry function Tree speeds centrifugal fan by remote control Horizontal flap swinging or to be set on a fixed position by remote control Night set back capability Anti-mould and anti-bacteria washable filters w w w. a r g o c l i m a . c o m Dinamic refrigerant control by microprocessor, electronic valve and fuzzy logic 158 PRODUCT NAME Features Cooling/Heating capacity Air flowrate Indoor (h.m.l.) Dehumidification Sound pressure Indoor (h.m.l.) Power supply Running consumption Refrigerant type Liquid pipe diameter Gas pipe diameter Net weight Indoor Net dimension Indoor (H./W./D.) Units kW BTU/h kcal/h m3/h l/h dB(A) V/Ph/Hz kW mm(inch") mm(inch") Kg mm FCR409VHG Cooling Heating 2,80 3,20 9.600 11.000 2.410 2.760 630-540-450 1 47-43-38 230/1/50 0,06 R407C 9,52(3/8") 12,7(1/2") 23,5 680x900x190 FCR412VHG Cooling Heating 3,60 4,20 12.300 14.400 3.100 3.610 630-540-450 1,5 47-43-38 230/1/50 0,06 R407C 9,52(3/8") 12,7(1/2") 23,5 680x900x190 FCR418VHG Cooling Heating 5,60 6,30 19.100 21.500 4.820 5.420 720-650-580 2,3 51-47-43 230/1/50 0,07 R407C 9,52(3/8") 15,88(5/8") 23,5 680x900x190 MULTISET V.R.F. - R407C improve your life AWR 409-412-418 VH High wall straight cooling and heat pump air conditioner Automatic change-over between cooling and heating mode Special function during heat pump start-up and defrosting cycle toavoid cool air in environment Temperature sensor inside the remote control “Auto I Feel” feature, give you the best comfort conditions This air conditioner may be controlled by remote wired controller with configuration, diagnostic and weekly timer capabilities Dry function Tangential fan by automatic control Horizontal flap swinging or to be set on a fixed position by remote control Night set back capability Anti-mould and anti-bacteria washable filters PRODUCT NAME Features Cooling/Heating capacity Air flowrate Indoor (h.m.l.) Dehumidification Sound pressure Indoor (h.m.l.) Power supply Running consumption Refrigerant type Liquid pipe diameter Gas pipe diameter Net weight Indoor Net dimension Indoor (H./W./D.) Units kW BTU/h kcal/h m3/h l/h dB(A) V/Ph/Hz kW mm(inch") mm(inch") Kg mm AWR409VH Cooling Heating 2,80 3,20 9.600 11.000 2.410 2.760 450-390-340 1,3 40-36-33 230/1/50 0,05 R407C 9,52(3/8") 12,7(1/2") 15 360x1.000x205 AWR412VH Cooling Heating 3,60 4,20 12.300 14.400 3.100 3.610 630-490-430 1,6 42-39-36 230/1/50 0,054 R407C 9,52(3/8") 12,7(1/2") 15 360x1.000x205 AWR418VH Cooling Heating 5,00 6,00 17.000 20.000 4.300 5.160 800-660-520 2,5 49-45-40 230/1/50 0,08 R407C 9,52(3/8") 15,88(5/8") 15 360x1.000x205 w w w. a r g o c l i m a . c o m Dinamic refrigerant control by microprocessor, electronic valve and fuzzy logic 159 MULTISET V.R.F. - R407C improve your life CONTROLS REM-H HLA Infrared remote control for cassette, floor/ceiling and ceiling indoor units REM-H HWS Simplified wired remote control which to be used with the full range of indoor units w w w. a r g o c l i m a . c o m REM-H HWA Full features wired remote control to be used with the full range of indoor units 160 REM-SSYS-H HW System controller WEEKLY TIMER Digital timer to setup days and week cycles; to be connected with wired remote control MULTISET V.R.F. - R407C improve your life ACCESSORIES Distribution kit two/more ways Air intake kit & filter for ducted series ADR425, ADR436, ADR448 Air distributor three ways for ducted series ADRxx18,ADRxx22 Refrigerant electronic valve for installation outside of the indoor unit w w w. a r g o c l i m a . c o m Air distributor two ways for ducted series ADRxx9, ADRxx12 161 improve your life RULES FOR THE APPLICATION OF THE ENERGY LABEL Our air conditioners are fully compliant to the most recent European regulations concerning the reduction of the energy consumption and the lessening of the atmosphere pollution. The energy labels, indicating the energy efficiency class, have been introduced by the European Directive 2002/31/EC, which makes reference to the standard EN14511 for the determination of the energy class. The energy labels must be applied on products (air-conditioners air-to-air up to 12 kW of cooling capacity) in exposition on the points of sale, with the objective of giving information on the energy efficiency of the air-conditioners to the final user. The energy label is divided in two parts: one is coloured and generic, the other, adhesive and black and white, contains the technical and efficiency data of each product or combination of indoor/outdoor units and must be sticked on the one, in the empty space. Our company supplies both parts of the energy label: the one, coloured, is delivered directly to the points of sale (responsible for the application of the energy label on the products in exposition), the other (black and white) with technical and efficiency data is put directly inside the product carton box at the end of the production process (to make easier for the seller the application of the right label). If the black & white part of the energy label is lost, each point of sale can immediately download it from the dedicated section in our Web Site, or ask for it to our Marketing Department. Example of Energy label: 1) generic part - coloured The energy label shows the belonging class: “A” class is the best one and it is assigned on the basis of specific tables that put in relation the thermal capacity and the energy consumption for each product. The ratios used to assign the energy class w w w. a r g o c l i m a . c o m are the following: 162 E.E.R. = Energy Efficiency Ratio, is the relation between the cooling capacity (kW) and the power consumption in cooling mode (kW) C.O.P. = Coefficient Of Performance, is the relation between the heating capacity (kW) and the power consumption in heating mode (kW) 2) specific part - black & white 702006016-02/06 www.argoclima.com www.argoclima.com improve your life argo clima S.p.A. headquarters Via Varese, 90 21013 Gallarate (VA) ITALY Tel: +39 0331 755111 Fax:+39 0331 776240 www.argoclima.com N.B. The manufacturing company does not assume any responsibility for errors or omissiones contained in this catalogue and reserves the right to make, at any time without previous warning, any change considered necessary, for either technical or commercial purposes, to its products. argo clima S.p.A is a company of Aer.Fi. group, an European leader in air conditioner, heating and air treatment markets
Podobné dokumenty
Rychlá montáž – zvýšený výkon
** Hrubé hodnoty, nejsou v souladu s normou EN14511-3:2013. Tyto hodnoty neberou v úvahu opravu o poměrný topný výkon a vstupní výkon vytvářený vodním čerpadlem pro překonání vnitřního poklesu
tlak...
Katalog výrobků Sanit.cz
Element INEO - Urinal pro Infra nebo tlakový splachovač podomítkový
Samonosná rámová konstrukce s výškově nastavitelnými opěrnými nohami, stavební rozměry. výška – 1120 mm, šířka – 525 mm,
hloubka ...