Air cooled chiller portfolio
Transkript
Aplikované systémy Ceník 2014 → Table of contents Type Refrigerant Compressor Capacity Page Air cooled chiller Inverter R-410A Swing EWAQ-A Material 5-13 kW 3 Air cooled heat pump Inverter R-410A Swing EWYQ-A 5-13 kW 4 Air cooled chiller Inverter R-410A Scroll EWAQ-BAW 17-75 kW 5 Air cooled heat pump Inverter R-410A Scroll EWYQ-BAW 17-75 kW 5 Air cooled chiller R-407C Scroll EUWA-KBZW 11-55 kW 6 Air cooled heat pump R-407C Scroll EUWY-KBZW 12-54 kW 7 Air cooled chiller R-410A Scroll EWAQ-DAYN 80-252 kW 8 Air cooled heat pump R-410A Scroll EWYQ-DAYN 88-283 kW 9 Water cooled chiller R-407C Scroll EWWP-KBW1N 13-65 kW 10 Water cooled chiller R-407C Scroll EWWP-KAW1M 86-194 kW 11 Condenserless chiller R-407C Scroll EWLP-KBW1N 12-62 kW 12 Condensing unit heat pump Inverter R-410A Scroll ERQ 11-28 kW Hydronic Kit EKBT / EHMC 13 14 Rooftop heat pump R-410A Scroll UATYQ-CY1 27-73 kW 14 Rooftop heat pump R-407C Scroll UATYP-AY1 79-110 kW 14 FWE-C 2,1 - 10 kW 15 Fan coil Low ESP duct Medium ESP duct FWB-B 2,6 - 11 kW 16 Medium ESP duct / BLDC FWP-A 2,6 – 6,5 kW 17 High ESP flexi duct FWD-A 3,9 - 18 kW 18 Cassette 600x600 FWF-C 2,5 - 4,5 kW 19 Cassette 600x600 FWF-B 1,7 - 4 kW 19 Cassette 900x900 FWC-B 5 - 7,2 kW 19 Wall mounted FWT-C 2,3 - 5,3 kW 20 Floor standing FWV-D 1,5 - 8 kW 22 Flexi type FWL-D 1,5 - 8 kW 23 Flexi concealed FWM-D 1,5 - 8 kW 24 Floor standing / BLDC FWZ-A 2,6 - 10 kW 26 Flexi type / BLDC FWR-A 2,6 - 10 kW 27 Flexi concealed / BLDC FWS-A 2,6 - 10 kW 28 Overview: Air cooled chiller portfolio 30 Overview: Portfolio Water cooled and Condenserless units 32 Large Chillers options and accessories summary 32 Air Cooler 34 Air Handling Unit 34 Dry Cooler & Condenser 34 Cooling Tower 34 Compressor Service Screw/Recip 34 Measuring conditions 34 Commercial terms and conditions 35 ▪ NOTES The pricelist is valid from 1. April 2014. All prior pricelists are not valid anymore. All prices are list prices in Euro and excl. VAT. The Daikin Commercial Terms and Conditions apply (see last page or http://www.daikin-ce.com). We reserve the right for printing errors and model changes. 2 → EWAQ-A ▪ EWAQ-A AIR COOLED CHILLER INVERTER High ESEER thanks to inverter technology, integrated hydronics. Unit size (1 phase) Price Cooling capacity EER ESEER Sound power level EWAQ005ADVP EWAQ006ADVP EWAQ007ADVP dB(A) 77.996,– 5,2 2,75 3,75 62 85.392,– 6 2,55 3,83 62 94.734,– 7,1 2,41 3,87 63 CZK 11.660,– 11.660,– 11.660,– EWAQ009ACV3P EWAQ010ACV3P EWAQ011ACV3P dB(A) 108.087,– 8,6 3,05 4,31 64 114.438,– 9,6 2,93 4,3 64 122.907,– 11,1 2,85 4,33 64 CZK CZK CZK 12.904,– on request 3.588,– 12.904,– on request 3.588,– 12.904,– on request 3.588,– EWAQ009ACW1P EWAQ011ACW1P EWAQ013ACW1P dB(A) 112.745,– 9,1 2,99 4,43 64 123.979,– 11,1 2,85 4,44 64 131.405,– 13,3 2,57 4,36 66 CZK CZK CZK 12.904,– on request 3.588,– 12.904,– on request 3.588,– 12.904,– on request 3.588,– CZK kW Options OP10 evaporator heater tape Unit size (1 phase) Price Cooling capacity EER ESEER Sound power level CZK kW Options OP10 SOPHP EKRP1HBA evaporator heater tape high ESP pump (up to 90 kPa) digital I/0 PCB Unit size (3 phase) Price Cooling capacity EER ESEER Sound power level CZK kW Options OP10 SOPHP EKRP1HBA evaporator heater tape high ESP pump (up to 90 kPa) digital I/0 PCB 3 → EWYQ-A ▪ EWYQ-A AIR COOLED HEAT PUMP INVERTER Wide operation range - ambient temperature in heating down to -15°C. Unit size (1 phase) Price Cooling capacity EER Heating capacity COP Sound power level EWYQ005ADVP EWYQ006ADVP EWYQ007ADVP dB(A) 90.077,– 5,2 2,75 5,65 2,87 62 97.275,– 6 2,55 6,35 2,83 62 103.910,– 7,1 2,41 7,75 2,74 63 CZK 11.660,– 11.660,– 11.660,– EWYQ009ACV3P EWYQ010ACV3P EWYQ011ACV3P dB(A) 124.403,– 8,6 3,05 4,31 9,9 3,3 64 130.953,– 9,6 2,93 4,3 11,4 3,29 64 138.801,– 11,1 2,85 4,33 12,9 3,27 64 CZK CZK CZK 12.904,– on request 3.588,– 12.904,– on request 3.588,– 12.904,– on request 3.588,– EWYQ009ACW1P EWYQ011ACW1P EWYQ013ACW1P dB(A) 129.258,– 9,1 2,99 4,43 10,9 3,28 64 140.296,– 11,1 2,85 4,44 12,4 3,27 64 148.342,– 13,3 2,57 4,36 13,9 3,25 66 CZK CZK CZK 12.904,– on request 3.588,– 12.904,– on request 3.588,– 12.904,– on request 3.588,– CZK kW kW Options OP10 evaporator heater tape Unit size (1 phase) Price Cooling capacity EER ESEER Heating capacity COP Sound power level CZK kW kW Options OP10 SOPHP EKRP1HBA evaporator heater tape high ESP pump (up to 90 kPa) digital I/0 PCB Unit size (3 phase) Price Cooling capacity EER ESEER Heating capacity COP Sound power level CZK kW kW Options OP10 SOPHP EKRP1HBA evaporator heater tape high ESP pump (up to 90 kPa) digital I/0 PCB 4 → EWAQ-BAW, EWYQ-BAW ▪ EWAQ-BAW AIR COOLED CHILLER INVERTER High efficiency with leader-of-class ESEER. No buffer tank required for standard applications. Unit size EWAQ016BAW EWAQ021BAW EWAQ025BAW EWAQ032BAW EWAQ040BAW EWAQ050BAW EWAQ064BAW Price Cooling capacity (nominal) EWAQ - BAWN / BAWP ESEER EWAQ - BAWN / BAWP Sound power level CZK kW dB(A) 187.494,– 17,4 / 16,6 4,33 / 4,21 78 220.797,– 21,7 / 20,7 4,08 / 4,18 78 249.008,– 25,8 / 24,7 3,85 / 4,04 78 287.287,– 32,3 / 30,9 3,39 / 3,62 80 380.080,– 43,4 / 41,5 4,19 / 4,24 81 423.394,– 51,8 / 49,7 3,96 / 4,12 81 488.902,– 64,5 / 62,3 3,64 / 3,78 83 CZK CZK CZK CZK 15.133,– 16.810,– 24.653,– 11.198,– 15.133,– 16.810,– 24.653,– 11.198,– 15.133,– 16.810,– 24.653,– 11.198,– 15.133,– 20.500,– 24.653,– 11.198,– 17.716,– 20.500,– 30.064,– 13.656,– 17.716,– 20.500,– 30.064,– 13.656,– 17.716,– 20.500,– 30.064,– 13.656,– Options OP10 OPSP OPHP OPZL Evaporator electric heater One centrifugal pump (low lift) One centrifugal pump (high lift) Low leaving water operation down to -10 °C Kit Demand PCB Remote: On/Off, Cool/heat, thermo On/Off EKRUAHT Additional remote user interface BHGP26A1 Digital pressure gauges External adaptor for: DTA104A62 Demand and Low noise control RTD-W Modbus interface EKRP1AHT CZK 3.993,– 3.993,– 3.993,– 3.993,– 7.986,– 7.986,– 7.986,– CZK CZK 5.932,– 14.583,– 5.932,– 14.583,– 5.932,– 14.583,– 5.932,– 14.583,– 5.932,– 29.166,– 5.932,– 29.166,– 5.932,– 29.166,– CZK 12.210,– 12.210,– 12.210,– 12.210,– 24.420,– 24.420,– 24.420,– CZK 10.272,– 10.272,– 10.272,– 10.272,– 10.272,– 10.272,– 10.272,– ▪ EWYQ-BAW AIR COOLED HEAT PUMP INVERTER Wide operation range - ambient temperature in heating down to -15°C. Unit size EWYQ016BAW EWYQ021BAW EWYQ025BAW EWYQ032BAW EWYQ040BAW EWYQ050BAW EWYQ064BAW Price Cooling capacity (nominal) EWYQ - BAWN / BAWP ESEER EWYQ - BAWN / BAWP Heating capacity (nominal) EWYQ - BAWN / BAWP COP EWYQ - BAWN / BAWP Sound power level CZK kW dB(A) 215.618,– 17,4 / 16,6 4,33 / 4,21 16,2 / 17,0 2,93 / 2,97 78 253.955,– 21,7 / 20,7 4,08 / 4,18 20,3 / 21,3 2,86 / 2,86 78 286.391,– 25,8 / 24,7 3,85 / 4,04 24,6 / 25,7 2,76 / 2,75 80 330.429,– 32,3 / 30,9 3,39 / 3,62 30,7 / 32,1 2,90 / 2,89 80 437.051,– 43,4 / 41,5 4,19 / 4,24 41,6 / 42,5 2,90 / 2,89 81 486.905,– 51,8 / 49,7 3,96 / 4,12 49,0 / 51,1 2,78 / 2,76 83 562.279,– 64,5 / 62,3 3,64 / 3,78 61,5 / 63,7 2,97 / 2,94 83 CZK CZK CZK CZK 15.133,– 16.810,– 24.653,– 11.198,– 15.133,– 16.810,– 24.653,– 11.198,– 15.133,– 16.810,– 24.653,– 11.198,– 15.133,– 20.500,– 24.653,– 11.198,– 17.716,– 20.500,– 30.064,– 13.656,– 17.716,– 20.500,– 30.064,– 13.656,– 17.716,– 20.500,– 30.064,– 13.656,– CZK 3.993,– 3.993,– 3.993,– 3.993,– 7.986,– 7.986,– 7.986,– CZK CZK 5.932,– 14.583,– 5.932,– 14.583,– 5.932,– 14.583,– 5.932,– 14.583,– 5.932,– 29.166,– 5.932,– 29.166,– 5.932,– 29.166,– CZK 12.210,– 12.210,– 12.210,– 12.210,– 24.420,– 24.420,– 24.420,– CZK 10.272,– 10.272,– 10.272,– 10.272,– 10.272,– 10.272,– 10.272,– kW Options OP10 OPSP OPHP OPZL Evaporator electric heater One centrifugal pump (low lift) One centrifugal pump (high lift) Low leaving water operation down to -10 °C Kit Demand PCB Remote: On/Off, Cool/heat, thermo On/Off EKRUAHT Additional remote user interface BHGP26A1 Digital pressure gauges External adaptor for: DTA104A62 Demand and Low noise control Modbus interface RTD-W EKRP1AHT 5 → EUWA-KBZW ▪ EUWA-KBZW AIR COOLED CHILLER Unit size Price version N * Price version P * Price version B * Cooling capacity version N / P / B EER version N / P / B Sound power level EUWA*5KBZW EUWA*8KBZW EUWA*10KBZW EUWA*12KBZW dB(A) 94.355,– 120.626,– 146.956,– 11,2 / 11,7 / 11,7 2,46 / 2,55 / 2,55 67 135.442,– 161.685,– 187.985,– 17,7 / 18,2 / 18,2 2,38 / 2,46 / 2,46 76 155.434,– 181.678,– 208.009,– 22,3 / 22,9 / 22,9 2,51 / 2,58 / 2,58 78 187.437,– 213.708,– 240.009,– 26,6 / 26,8 / 26,8 2,24 / 2,29 / 2,29 78 7.059,– 7.059,– 695,– 7.059,– 7.059,– 1.649,– 7.059,– 7.059,– 1.649,– 7.059,– 7.059,– 1.649,– CZK CZK CZK kW Options OPZH OPZL OPHF glycol application to -5°C LWE glycol application to -10°C LWE fan motor size up (50 Pa ESP) CZK CZK CZK Version * OP10 OPHP evaporator heater tape pump size up CZK CZK soft starter kit gauges kit 5/8Hp units gauges kit 10/12Hp units BMS address card remote user interface remote buffertank (200 l) CZK CZK CZK CZK CZK CZK N P B N P B N P B N P B 4.716,– 9.491,– 11.660,– 4.716,– 9.491,– 11.660,– 4.716,– 9.491,– 11.660,– 4.716,– 9.491,– 11.660,– – 2.893,– 2.893,– – 2.893,– 2.893,– – 2.893,– 2.893,– – 2.893,– 2.893,– Kit EKSS EKGAU5/8KA EKGAU10/12KA EKAC10C EKRUMCA EKBT 12.239,– 6.598,– – 4.290,– 6.286,– 42.881,– Unit size Price version N * Price version P * Price version B * Cooling capacity version N / P / B EER version N / P / B Sound power level CZK CZK CZK kW dB(A) 12.239,– 6.598,– – 4.290,– 6.286,– 42.881,– 12.239,– – 6.598,– 4.290,– 6.286,– 42.881,– 12.239,– – 6.598,– 4.290,– 6.286,– 42.881,– EUWA*16KBZW EUWA*20KBZW EUWA*24KBZW 231.849,– 266.889,– 293.161,– 34,4 / 35,4 / 35,4 2,31 / 2,34 / 2,34 79 292.901,– 327.940,– 354.213,– 46,4 / 47,5 / 47,5 2,56 / 2,61 / 2,61 81 332.021,– 367.031,– 393.331,– 55,0 / 56,1 / 56,1 2,28 / 2,32 / 2,32 81 7.059,– 7.059,– 3.211,– P 9.491,– 11.025,– 7.059,– 7.059,– 3.211,– P 9.491,– 11.025,– 7.059,– 7.059,– 3.211,– P 9.491,– 11.025,– Options OPZH OPZL OPHF Version * OP10 OPHP glycol application to -5°C LWE glycol application to -10°C LWE fan motor size up (50 Pa ESP) CZK CZK CZK evaporator heater tape pump size up CZK CZK gauges kit 16Hp units gauges kit 20/24Hp units BMS address card remote user interface remote buffertank (200 l) CZK CZK CZK CZK CZK N 4.716,– – B 11.660,– 11.025,– N 4.716,– – B 11.660,– 11.025,– N 4.716,– – Kit EKGAU16KA EKGAU20/24KA EKAC10C EKRUMCA EKBT 10.735,– – 4.290,– 6.286,– 42.881,– – 10.735,– 4.290,– 6.286,– 42.881,– Note: EKAC10C is needed for direct BMS connection via Modbus EKAC10C is needed to install EKRUMCA Remarks * N = Normal unit with mainswitch, flowswitch, without hydraulic module. P = N-version with hydraulic module with pump & expansion vessel. B = N-version with hydraulic module with buffertank, pump & expansion vessel. 6 – 10.735,– 4.290,– 6.286,– 42.881,– B 11.660,– 11.025,– → EUWY-KBZW ▪ EUWY-KBZW AIR COOLED HEAT PUMP Unit size Price version N * Price version P * Price version B * Cooling capacity version N / P / B EER version N / P / B Heating capacity version N / P / B COP version N / P / B Sound power level CZK CZK CZK kW kW dB(A) EUWY*5KBZW EUWY*8KBZW EUWY*10KBZW EUWY*12KBZW 108.532,– 134.804,– 161.077,– 9,05 / 9,42 / 9,42 2,37 / 2,41 / 2,41 12,0 / 11,4 / 11,4 2,60 / 2,52 / 2,52 67 155.724,– 181.996,– 208.326,– 17,0 / 17,5 / 17,5 2,26 / 2,34 / 2,34 18,6 / 17,9 / 17,9 2,61 / 2,60 / 2,60 76 178.727,– 205.028,– 231.328,– 20,8 / 21,5 / 21,5 2,4 / 2,47 / 2,47 24,2 / 23,3 / 23,3 2,65 / 2,59 / 2,59 78 215.589,– 241.860,– 268.163,– 24,8 / 25,4 / 25,4 2,16 / 2,21 / 2,21 27,2 / 26,0 / 26,0 2,50 / 2,50 / 2,50 78 Options OPZH OPZL OPHF Version * OP10 OPHP glycol application to -5°C LWE glycol application to -10°C LWE fan motor size up (50 Pa ESP) CZK CZK CZK evaporator heater tape pump size up CZK CZK soft starter kit gauges kit 5/8Hp units gauges kit 10/12Hp units BMS address card remote user interface remote buffertank (200 l) CZK CZK CZK CZK CZK CZK 7.059,– 7.059,– 7.059,– 7.059,– 7.059,– 7.059,– 7.059,– 7.059,– 695,– 1.649,– 1.649,– 1.649,– N P B N P B N P B N P B 4.716,– 9.491,– 11.660,– 4.716,– 9.491,– 11.660,– 4.716,– 9.491,– 11.660,– 4.716,– 9.491,– 11.660,– – 2.893,– 2.893,– – 2.893,– 2.893,– – 2.893,– 2.893,– – 2.893,– 2.893,– Kit EKSS EKGAU5/8KA EKGAU10/12KA EKAC10C EKRUMCA EKBT 12.239,– 6.598,– – 4.290,– 6.286,– 42.881,– Unit size Price version N * Price version P * Price version B * Cooling capacity version N / P / B EER version N / P / B Heating capacity version N / P / B COP version N / P / B Sound power level CZK CZK CZK kW kW dB(A) 12.239,– 6.598,– – 4.290,– 6.286,– 42.881,– 12.239,– – 6.598,– 4.290,– 6.286,– 42.881,– 12.239,– – 6.598,– 4.290,– 6.286,– 42.881,– EUWY*16KBZW EUWY*20KBZW EUWY*24KBZW 266.600,– 301.639,– 327.940,– 34,1 / 35,0 / 35,0 2,29 / 2,3 / 2,3 37,1 / 35,7 / 35,7 2,61 / 2,55 / 2,55 79 336.824,– 371.863,– 398.164,– 39,8 / 40,9 / 40,9 2,43 / 2,46 / 2,46 46,2 / 44,5 / 44,5 2,64 / 2,6 / 2,6 81 381.845,– 416.885,– 443.127,– 49,8 / 50,9 / 50,9 2,18 / 2,22 / 2,22 54,2 / 52,5 / 52,5 2,51 / 2,49 / 2,49 81 7.059,– 7.059,– 3.211,– P 9.491,– 11.025,– 7.059,– 7.059,– 3.211,– P 9.491,– 11.025,– 7.059,– 7.059,– 3.211,– P 9.491,– 11.025,– Options OPZH OPZL OPHF Version * OP10 OPHP glycol application to -5°C LWE glycol application to -10°C LWE fan motor size up (50 Pa ESP) CZK CZK CZK evaporator heater tape pump size up CZK CZK gauges kit 16Hp units gauges kit 20/24Hp units BMS address card remote user interface remote buffertank (200 l) CZK CZK CZK CZK CZK N 4.716,– – B 11.660,– 11.025,– N 4.716,– – B 11.660,– 11.025,– N 4.716,– – Kit EKGAU16KA EKGAU20/24KA EKAC10C EKRUMCA EKBT 10.735,– – 4.290,– 6.286,– 42.881,– – 10.735,– 4.290,– 6.286,– 42.881,– Note: EKAC10C is needed for direct BMS connection via Modbus EKAC10C is needed to install EKRUMCA Remarks * N = Normal unit with mainswitch, flowswitch, without hydraulic module. P = N-version with hydraulic module with pump & expansion vessel. B = N-version with hydraulic module with buffertank, pump & expansion vessel. 7 – 10.735,– 4.290,– 6.286,– 42.881,– B 11.660,– 11.025,– → EWAQ-DAYN ▪ EWAQ-DAYN AIR COOLED CHILLER Unit size EWAQ080DAYN EWAQ100DAYN EWAQ130DAYN EWAQ150DAYN dB(A) 490.889,– 79,4 / 81,0 2,94 / 2,93 3,88 / 3,82 86 611.578,– 104 / 106 2,82 / 2,85 3,79 / 3,83 86 763.768,– 130 / 133 2,74 / 2,77 4,03 / 3,97 88 824.274,– 151 / 154 2,64 / 2,66 3,95 / 3,96 89 single pump contactor twin pump contactor single pump twin pump high ESP - single pump buffer tank inverter fans (for low ambient -15°C) glycol 0°C / -10°C dual pressure relief valve evaporator heater tape service valves A-meter / V-meter low noise (=OPIF + compressor housing) condenser protection grills CZK CZK CZK CZK CZK CZK CZK CZK CZK CZK CZK CZK CZK CZK 8.190,– 17.909,– 66.701,– 100.051,– 100.051,– 48.558,– 33.967,– 6.987,– 23.457,– 11.538,– 23.574,– 16.411,– 50.935,– 6.370,– 8.190,– 17.909,– 66.701,– 100.051,– 100.051,– 48.558,– 33.967,– 6.987,– 23.457,– 11.538,– 23.574,– 16.411,– 50.935,– 6.370,– 8.190,– 17.909,– 66.701,– 100.051,– 100.051,– 48.558,– 33.967,– 6.987,– 33.321,– 11.538,– 23.574,– 16.411,– 50.935,– 10.010,– 8.190,– 17.909,– 66.701,– 100.051,– 100.051,– 48.558,– 33.967,– 6.987,– 33.321,– 11.538,– 23.574,– 16.411,– 50.935,– 10.010,– adress card remote user interface counter pipes CZK CZK CZK 8.734,– 12.738,– 1.822,– 8.734,– 12.738,– 1.822,– 8.734,– 12.738,– 1.822,– 8.734,– 12.738,– 1.822,– EWAQ180DAYN EWAQ210DAYN EWAQ240DAYN EWAQ260DAYN dB(A) 974.557,– 181 / 184 2,76 / 2,77 4,04 / 4,02 90 1.046.394,– 208 / 211 2,74 / 2,75 4,00 / 4,02 90 1.181.264,– 234 / 238 2,77 / 2,82 3,89 / 4,00 91 1.296.581,– 252 / 256 2,63 / 2,67 3,73 / 3,84 91 single pump contactor twin pump contactor single pump twin pump high ESP - single pump buffer tank inverter fans (for low ambient -15°C) glycol 0°C / -10°C dual pressure relief valve evaporator heater tape service valves A-meter / V-meter low noise (=OPIF + compressor housing) condenser protection grills CZK CZK CZK CZK CZK CZK CZK CZK CZK CZK CZK CZK CZK CZK 8.190,– 17.909,– 90.951,– 136.454,– 136.454,– 48.558,– 50.935,– 6.987,– 33.321,– 11.538,– 23.574,– 16.411,– 76.447,– 10.010,– 8.190,– 17.909,– 90.951,– 136.454,– 136.454,– 48.558,– 50.935,– 6.987,– 33.321,– 11.538,– 23.574,– 16.411,– 76.447,– 10.010,– 8.190,– 17.909,– 97.027,– 145.555,– 145.555,– 48.558,– 82.495,– 6.987,– 33.321,– 11.538,– 23.574,– 16.411,– 123.742,– 12.419,– 8.190,– 17.909,– 97.027,– 145.555,– 145.555,– 48.558,– 82.495,– 6.987,– 33.321,– 11.538,– 23.574,– 16.411,– 123.742,– 12.419,– adress card remote user interface counter pipes counter pipes CZK CZK CZK CZK 8.734,– 12.738,– 1.822,– – 8.734,– 12.738,– 1.822,– – 8.734,– 12.738,– – 2.257,– 8.734,– 12.738,– – 2.257,– Price Cooling capacity version N / P or B EER version N / P or B ESEER version N / P or B Sound power level CZK kW Options OPSC OPTC OPSP OPTP OPHP OPBT OPIF OPZL OP03 OP10 OP12 OP57 OPLN OPCG Kit EKACPG EKRUPG EKGN 210 Unit size Price Cooling capacity version N / P or B EER version N / P or B ESEER version N / P or B Sound power level CZK kW Options OPSC OPTC OPSP OPTP OPHP OPBT OPIF OPZL OP03 OP10 OP12 OP57 OPLN OPCG Kit EKACPG EKRUPG EKGN 210 EKGN 260 Note: EKACPG needs to be installed together with EKLONPG and EKBNPG 8 → EWYQ-DAYN ▪ EWYQ-DAYN AIR COOLED HEAT PUMP Unit size EWYQ080DAYN EWYQ100DAYN EWYQ130DAYN EWYQ150DAYN dB(A) 575.645,– 76,6 / 78,1 2,86 / 2,84 3,84 / 3,76 88,2 / 86,5 2,89 / 2,79 86 684.973,– 100 / 101 2,72 / 2,72 3,68 / 3,68 115 / 113 2,97 / 2,89 86 922.887,– 135 / 138 2,79 / 2,82 4,03 / 3,99 150 / 148 2,97 / 2,90 88 975.496,– 144 / 147 2,55 / 2,57 3,84 / 3,84 166 / 163 2,79 / 2,71 89 single pump contactor twin pump contactor single pump twin pump high ESP - single pump buffer tank inverter fans (for low ambient -15°C) glycol 0°C / -10°C dual pressure relief valve evaporator heater tape service valves A-meter / V-meter low noise (=OPIF + compressor housing) condenser protection grills CZK CZK CZK CZK CZK CZK CZK CZK CZK CZK CZK CZK CZK CZK 8.190,– 17.909,– 66.701,– 100.051,– 100.051,– 48.558,– 33.967,– 6.987,– 23.457,– 11.538,– 23.574,– 16.411,– 50.935,– 6.370,– 8.190,– 17.909,– 66.701,– 100.051,– 100.051,– 48.558,– 33.967,– 6.987,– 23.457,– 11.538,– 23.574,– 16.411,– 50.935,– 6.370,– 8.190,– 17.909,– 66.701,– 100.051,– 100.051,– 48.558,– 33.967,– 6.987,– 33.321,– 11.538,– 23.574,– 16.411,– 50.935,– 10.010,– 8.190,– 17.909,– 66.701,– 100.051,– 100.051,– 48.558,– 33.967,– 6.987,– 33.321,– 11.538,– 23.574,– 16.411,– 50.935,– 10.010,– adress card remote user interface counter pipes CZK CZK CZK 8.734,– 12.738,– 1.822,– 8.734,– 12.738,– 1.822,– 8.734,– 12.738,– 1.822,– 8.734,– 12.738,– 1.822,– EWYQ180DAYN EWYQ210DAYN EWYQ230DAYN EWYQ250DAYN dB(A) 1.108.133,– 182 / 185 2,81 / 2,82 4,06 / 4,02 200 / 197 2,89 / 2,82 90 1.239.860,– 210 / 213 2,75 / 2,76 3,94 / 3,96 227 / 223 2,89 / 2,82 90 1.314.510,– 229 / 233 2,74 / 2,78 3,93 / 4,04 260 / 256 3,03 / 2,98 91 1.430.362,– 251 / 254 2,64 / 2,67 3,76 / 3,87 283 / 279 2,87 / 2,83 91 single pump contactor twin pump contactor single pump twin pump high ESP - single pump buffer tank inverter fans (for low ambient -15°C) glycol 0°C / -10°C dual pressure relief valve evaporator heater tape service valves A-meter / V-meter low noise (=OPIF + compressor housing) condenser protection grills CZK CZK CZK CZK CZK CZK CZK CZK CZK CZK CZK CZK CZK CZK 8.190,– 17.909,– 90.951,– 136.454,– 136.454,– 48.558,– 50.935,– 6.987,– 33.321,– 11.538,– 23.574,– 16.411,– 76.447,– 10.010,– 8.190,– 17.909,– 90.951,– 136.454,– 136.454,– 48.558,– 50.935,– 6.987,– 33.321,– 11.538,– 23.574,– 16.411,– 76.447,– 10.010,– 8.190,– 17.909,– 97.027,– 145.555,– 145.555,– 48.558,– 82.495,– 6.987,– 33.321,– 11.538,– 23.574,– 16.411,– 123.742,– 12.419,– 8.190,– 17.909,– 97.027,– 145.555,– 145.555,– 48.558,– 82.495,– 6.987,– 33.321,– 11.538,– 23.574,– 16.411,– 123.742,– 12.419,– adress card remote user interface counter pipes counter pipes CZK CZK CZK CZK 8.734,– 12.738,– 1.822,– – 8.734,– 12.738,– 1.822,– – 8.734,– 12.738,– – 2.257,– 8.734,– 12.738,– – 2.257,– Price Cooling capacity version N / P or B EER version N / P or B ESEER version N / P or B Heating capacity version N / P or B COP version N / P or B Sound power level CZK kW kW Options OPSC OPTC OPSP OPTP OPHP OPBT OPIF OPZL OP03 OP10 OP12 OP57 OPLN OPCG Kit EKACPG EKRUPG EKGN 210 Unit size Price Cooling capacity version N / P or B EER version N / P or B ESEER version N / P or B Heating capacity version N / P or B COP version N / P or B Sound power level CZK kW kW Options OPSC OPTC OPSP OPTP OPHP OPBT OPIF OPZL OP03 OP10 OP12 OP57 OPLN OPCG Kit EKACPG EKRUPG EKGN 210 EKGN 260 Note: EKACPG needs to be installed together with EKLONPG and EKBNPG OPIF needs for heating down to -15°C ambient temperature, without OPIF down to -10°C ambient temperature. 9 → EWWP-KBW1N ▪ EWWP-KBW1N WATER COOLED CHILLER Unit size EWWP014KBW1N EWWP022KBW1N EWWP028KBW1N EWWP035KBW1N 135.817,– 21,4 3,49 27,5 64 155.869,– 27,8 3,54 35,6 64 188.014,– kW dB(A) 94.673,– 12,9 3,44 16,7 64 glycol application to -5 °C LWE glycol application to -10 °C LWE CZK CZK 7.059,– 7.059,– 7.059,– 7.059,– 7.059,– 7.059,– 7.059,– 7.059,– low noise kit 5 HP low noise kit 8/10/12 HP BMS address card remote user interface hydraulic module hydraulic module – pump size up hydraulic module hydraulic module – pump size up CZK CZK CZK CZK CZK CZK CZK CZK 6.134,– – 4.290,– 6.286,– 67.099,– 68.921,– – – – 6.134,– 4.290,– 6.286,– 67.099,– 68.921,– – – – 6.134,– 4.290,– 6.286,– 67.099,– 68.921,– 71.351,– 73.233,– – 6.134,– 4.290,– 6.286,– – – 71.351,– 73.233,– Price Cooling capacity EER Heat rejection capacity Sound power level CZK kW 32,3 3,54 41,5 71 Options OPZH OPZL Kit EKLS1 EKLS2 EKAC10C EKRUMCA EHMC10A10 EHMC10A80 EHMC15A10 EHMC15A80 Unit size Price Cooling capacity EER Heat rejection capacity Sound power level EWWP045KBW1N EWWP055KBW1N EWWP065KBW1N kW dB(A) 232.486,– 42,8 3,51 55,0 67 293.711,– 55,7 3,48 71,7 67 332.976,– 64,7 3,55 83 74 CZK kW Options OPZH OPZL glycol application to -5 °C LWE glycol application to -10 °C LWE CZK CZK 7.059,– 7.059,– 7.059,– 7.059,– 7.059,– 7.059,– Kit EKLS2 EKAC10C EKRUMCA EHMC15A10 EHMC15A80 EHMC30A10 EHMC30A80 low noise kit 8/10/12 HP (2 pcs.) BMS address card remote user interface hydraulic module hydraulic module – pump size up hydraulic module hydraulic module – pump size up CZK CZK CZK CZK CZK CZK CZK 12.268,– 4.290,– 6.286,– 71.351,– 73.233,– 75.980,– 78.412,– 12.268,– 4.290,– 6.286,– – – 75.980,– 78.412,– 12.268,– 4.290,– 6.286,– – – 75.980,– 78.412,– Note: EKAC10C is needed for direct BMS connection via Modbus EKAC10C is needed to install EKRUMCA 10 → EWWP-KAW1M ▪ EWWP-KAW1M WATER COOLED CHILLER Capacity index 090 100 110 120 CZK kW dB(A) EWWP045KAW1M EWWP045KAW1M ECB2MUW 420.508,– 85,7 71 EWWP045KAW1M EWWP055KAW1M ECB2MUW 472.614,– 98,6 71 EWWP055KAW1M EWWP055KAW1M ECB2MUW 524.720,– 112 71 EWWP055KAW1M EWWP065KAW1M ECB2MUW 583.435,– 121 75 CZK CZK 14.118,– 14.118,– 14.118,– 14.118,– 14.118,– 14.118,– 14.118,– 14.118,– Basic model Control box Price Cooling capacity Sound power level Options OPZH OPZL glycol application to -5°C LWE glycol application to -10°C LWE Capacity index Basic model Control box Price Cooling capacity Sound power level 130 145 155 165 EWWP065KAW1M EWWP065KAW1M EWWP045KAW1M EWWP055KAW1M EWWP055KAW1M ECB3MUW 696.541,– 154 73 EWWP055KAW1M EWWP055KAW1M EWWP055KAW1M ECB3MUW 748.647,– 167 73 21.177,– 21.177,– 21.177,– 21.177,– CZK kW dB(A) ECB2MUW 642.123,– 130 77 EWWP045KAW1M EWWP045KAW1M EWWP055KAW1M ECB3MUW 644.408,– 141 73 CZK CZK 14.118,– 14.118,– 21.177,– 21.177,– 175 185 195 CZK kW dB(A) EWWP055KAW1M EWWP055KAW1M EWWP065KAW1M ECB3MUW 807.335,– 176 76 EWWP055KAW1M EWWP065KAW1M EWWP065KAW1M ECB3MUW 866.050,– 185 78 EWWP065KAW1M EWWP065KAW1M EWWP065KAW1M ECB3MUW 924.738,– 194 79 CZK CZK 21.177,– 21.177,– 21.177,– 21.177,– 21.177,– 21.177,– Options OPZH OPZL glycol application to -5°C LWE glycol application to -10°C LWE Capacity index Basic model Control box Price Cooling capacity Sound power level Options OPZH OPZL glycol application to -5°C LWE glycol application to -10°C LWE 11 → EWLP-KBW1N ▪ EWLP-KBW1N CONDENSERLESS CHILLER Unit size EWLP012KBW1N EWLP020KBW1N EWLP026KBW1N EWLP030KBW1N dB(A) 85.210,– 12,1 2,88 64 122.246,– 20 3,03 64 140.272,– 26,8 3,15 64 169.207,– 31,2 3,09 71 glycol application to -5°C LWE glycol application to -10°C LWE CZK CZK 7.059,– 7.059,– 7.059,– 7.059,– 7.059,– 7.059,– 7.059,– 7.059,– low noise kit 5 HP low noise kit 8/10/12 HP BMS address card remote user interface hydraulic module hydraulic module – pump size up hydraulic module hydraulic module – pump size up CZK CZK CZK CZK CZK CZK CZK CZK 6.134,– – 4.290,– 6.286,– 67.099,– 68.921,– – – – 6.134,– 4.290,– 6.286,– 67.099,– 68.921,– – – – 6.134,– 4.290,– 6.286,– 67.099,– 68.921,– 71.351,– 73.233,– – 6.134,– 4.290,– 6.286,– – – 71.351,– 73.233,– Price Cooling capacity EER Sound power level CZK kW Options OPZH OPZL Kit EKLS1 EKLS2 EKAC10C EKRUMCA EHMC10A10 EHMC10A80 EHMC15A10 EHMC15A80 Unit size EWLP040KBW1N EWLP055KBW1N EWLP065KBW1N dB(A) 209.222,– 40 2,99 67 264.343,– 53,7 3,02 67 299.672,– 62,4 3,07 74 glycol application to -5°C LWE glycol application to -10°C LWE CZK CZK 7.059,– 7.059,– 7.059,– 7.059,– 7.059,– 7.059,– low noise kit 8/10/12 HP (2 pcs.) BMS address card remote user interface hydraulic module hydraulic module – pump size up hydraulic module hydraulic module – pump size up CZK CZK CZK CZK CZK CZK CZK 12.268,– 4.290,– 6.286,– 71.351,– 73.233,– 75.980,– 78.412,– 12.268,– 4.290,– 6.286,– – – 75.980,– 78.412,– 12.268,– 4.290,– 6.286,– – – 75.980,– 78.412,– Price Cooling capacity EER Sound power level CZK kW Options OPZH OPZL Kit EKLS2 EKAC10C EKRUMCA EHMC15A10 EHMC15A80 EHMC30A10 EHMC30A80 Note: EKAC10C is needed for direct BMS connection via Modbus EKAC10C is needed to install EKRUMCA 12 → ERQ ▪ ERQ Inverter heat pump condensing units ERQ-A High efficiency inverter heat pump outdoor units for connection to DX heat exchangers in Air Handling Units (AHU) or to CYQ Air Curtains Type for 1~ 230V power supply Capacity index Nominal cooling capacity Nominal heating capacity Price ERQ100AV1 ERQ125AV1 ERQ140AV1 100 11,2 12,5 95.665,– 125 14,0 16,0 119.544,– 140 15,5 18,0 133.924,– ERQ125AW1 ERQ200AW1 ERQ250AW1 125 14,0 16,0 104.167,– 200 22,4 25,0 166.124,– 250 28,0 31,5 193.711,– kW kW CZK Type for 3N~ 400V power supply Capacity index Nominal cooling capacity Nominal heating capacity Price kW kW CZK Notes: - When using for connection to CYQ Air Curtains, select an ERQ outdoor unit with an equal or higher capacity index than the capacity index of the Air Curtain - Specified capacity values are for evaporation temperature = 6 °C (cooling) / condensing temperature = 46 °C (heating), evaporator superheat = 5K,condenser sub-cool = 3K, on-coil temperature = 27 °CDB / 19 °CWB (cooling) / = 20 °CDB (heating) Control box Control type Control options Price CZK EKEQDCB EKEQFCB Daikin control • Room temperature control [via Remote Controller (accessory) or via External room temperature sensor (accessory)] • Return air temperature control (via a supplied thermistor) 19.588,– Free (External) control • 0~10V direct capacity control (5V = maintain capacity, >5V colder air wanted, <5V warmer air wanted) • Fixed evaporation / condensation temperature control 19.838,– Notes: - A control box is a necessary component of the system for AHU applications; it is not necessary for connection to CYQ Air Curtains - A wired remote controller (Standard or Basic) is required for the EKEQDCB control box; for the EKEQFCB box, it is optional (required for commissioning and servicing only) - Switching between cooling/heating operation with the EKEQFCB box must be done from the external control system, or via the optional KRC19-26 Cool/Heat selector Allowed heat exchanger capacity [kW] Expansion valve kit Minimum 6,3 7,9 10,0 12,4 15,5 17,7 24,7 EKEXV63 EKEXV80 EKEXV100 EKEXV125 EKEXV140 EKEXV200 EKEXV250 Maximum 7,8 9,9 12,3 15,4 17,6 24,6 30,8 Combinable units ERQ100y y y y ERQ125y y y y y ERQ140y y y y ERQ200- ERQ250- y y y y y y y y y Price CZK 4.601,– 4.889,– 5.064,– 5.353,– 5.526,– 6.018,– 6.394,– Notes: - An expansion valve kit is a necessary component of the system for AHU applications; it is not necessary for connection to CYQ Air Curtains, - The expansion valve kit needs to be selected based on the nominal design of the AHU heat exchanger, - The AHU heat exchanger needs to be designed for 40bar pressures, with an internal (refrigerant) volume between 0,3 and 8,3 l (not counting headers and distributors) - Specified capacity values are for evaporation temperature = 6 °C (cooling) / condensing temperature = 46 °C (heating), evaporator superheat = 5K,condenser sub-cool = 3K, on-coil temperature = 27 °CDB / 19 °CWB (cooling) / = 20 °CDB (heating) Unit-specific Accessories BRC1D52 BRC1E52B KRP4A51 RTD-20 KRCS01-1 KRC19-26 KJB111A Basic wired remote controller with weekly timer Standard wired remote controller with full-text interface and back-light Adaptor for external monitoring/control Adaptor for external monitoring/control with 0-10VDC linear capacity control External room temperature sensor Mechanical cool/heat selector Fixing box for cool/heat selector EKEQDCB EKEQFCB Price CZK y y y y y y y y y 3.096,– 4.071,– 4.977,– 11.758,– 2.371,– 1.620,– 752,– y y Notes: - A wired remote controller (Standard or Basic) is required for the EKEQDCB control box; for the EKEQFCB box, it is optional (required for commissioning and servicing only) - Switching between cooling/heating operation with the EKEQFCB box must be done from the external control system, or via the optional KRC19-26 Cool/Heat selector 13 → HYDRONIC KIT, ROOFTOP ▪ HYDRONIC KIT Buffer tanks EKBT EKBT500N EKBTC10N EKBT500C EKBTC10C 200 l buffer tank with casing 500 l buffer tank 1000 l buffer tank 500 l buffer tank with casing 1000 l buffer tank with casing CZK CZK CZK CZK CZK 42.881,– 53.905,– 74.738,– 117.126,– 156.158,– CZK CZK CZK CZK CZK CZK 67.099,– 68.921,– 71.351,– 73.233,– 75.980,– 78.412,– Hydraulic modules EHMC10A10 EHMC10A80 EHMC15A10 EHMC15A80 EHMC30A10 EHMC30A80 hydraulic module hydraulic module – high ESP hydraulic module hydraulic module – high ESP hydraulic module hydraulic module – high ESP ▪ UATYQ-CY1 ROOFTOP HEAT PUMP Convertible return and supply air: fan can be mounted in two directions Unit size Price Cooling capacity EER Heating capacity COP Sound power level UATYQ250CY1 UATYQ350CY1 UATYQ450CY1 UATYQ550CY1 UATYQ600CY1 UATYQ700CY1 dB(A) 175.852,– 27,34 3,36 24,91 3,40 82 255.232,– 35,58 3,30 34,79 3,21 83 330.031,– 44,72 3,43 41,79 3,25 83 392.687,– 55,69 3,33 53,93 3,47 87 407.246,– 66,82 3,4 61,69 3,32 90 408.731,– 72,6 3,36 69,61 3,25 90 CZK CZK CZK CZK CZK CZK CZK CZK CZK 26.881,– 29.657,– 16.926,– 41.285,– – – – – – 26.881,– 29.657,– 16.926,– – 43.381,– – – – – 26.881,– 29.657,– 16.926,– – – 45.551,– – – – 26.881,– 29.657,– 16.926,– – – – 47.793,– – – 26.881,– 29.657,– 16.926,– – – – – 50.178,– – 26.881,– 29.657,– 16.926,– – – – – – 52.709,– CZK kW kW Options DEC101A51 DEC102A51 DTA103A51 ECONO250AY1 ECONO350AY1 ECONO450AY1 ECONO550AY1 ECONO600AY1 ECONO700AY1 ▪ UATYP-AY1 ROOFTOP HEAT PUMP Belt driven fan enables air volume and static pressure to be adjusted as required. Unit size Price Cooling capacity EER Heating capacity COP Sound pressure level at 1m CZK kW kW dB(A) UATYP850AY1B UATYPC10AY1 UATYPC12AY1 482.354,– 78,60 2,18 87,80 2,73 74 599.135,– 101,10 2,34 102,30 2,45 80 686.874,– 109,60 2,27 126,30 2,7 80 14 → FWE-C, Low ESP duct fan coil ▪ FWE-C FAN COIL, ACCESSORIES 4-speed fan motor, available static pressure up to 50Pa Low ESP duct unit FWE-C FWE**CT-, 2 pipe unit, standard, without valves "FWE**CTV, 2 pipe unit, with 3-ways 230V on/off valve, factory mounted FWE**CTT, 2 pipe unit, with 2-ways 230V on/off valve, factory mounted Cooling capacity (Total at Super High Speed) Heating capacity (2-pipe at Super High Speed) FWE**CF-, 4 pipe unit, standard, without valves FWE**CFV, 4 pipe unit, with 3-ways 230V on/off valves, factory mounted FWE**CFT, 4 pipe unit, with 2-ways 230V on/off valves, factory mounted Cooling capacity (Total at Super High Speed) Heating capacity (4-pipe at Super High Speed) (1) 02 03 04 06 07 08 10 CZK 6.245,– 7.081,– 7.661,– 9.979,– 10.750,– 12.618,– 15.192,– CZK 10.698,– 11.530,– 12.170,– 14.477,– 15.245,– 17.038,– 19.601,– CZK 8.775,– 9.608,– 10.184,– 12.554,– 13.259,– 15.117,– 17.679,– kW kW 2,17 2,79 3,22 4,28 4,34 5,61 6,06 7,66 6,83 9,26 7,84 10,50 9,96 13,00 CZK 7.274,– 8.240,– 8.948,– 11.523,– 12.296,– 14.421,– 16.995,– CZK 15.181,– 16.142,– 16.847,– 19.409,– 20.177,– 22.291,– 24.854,– CZK 12.298,– 13.259,– 13.964,– 16.526,– 17.295,– 19.409,– 21.971,– kW kW 2,10 2,30 3,16 3,53 3,98 4,56 6,05 6,17 6,76 7,60 7,79 8,52 9,91 10,40 02 03 04 06 07 08 10 07 08 10 Accessories for FWE-C 2 pipes 3-ways on/off 230V valve kit EK2MV3B10C5 2.539,– EK2MV2B10C5 2.132,– EK4MV3B10C5 4.816,– EK4MV2B10C5 4.179,– CZK 2 pipes 2-ways on/off 230V valve kit CZK 4 pipes 3-ways on/off 230V valve kit CZK 4 pipes 2-ways on/off 230V valve kit CZK Controller for FWE-C 02 Controller electronic Standard version, (see note 2) CZK Controller electronic Advanced version CZK Controller electronic Advanced Plus version CZK Wall mounting kit (spacing collar) for FWEC*A CZK Temperature sensor kit for FWEC*A CZK Relative humidity sensor kit for FWEC2A and FWEC3A CZK 03 04 06 FWEC1A 2.546,– FWEC2A 3.993,– FWEC3A 5.439,– FWFCKA 435,– FWTSKA 231,– FWHSKA 607,– EPIMSB6 3.473,– Master / Slave interface CZK Notes: (1) Rating conditions: air 20°C DB, entering water 50°C, leaving water 40°C (2) FWEC1A can operate with 3 speeds of fan only, if it also manages 2 valves on 4-pipes unit 15 → FWB-B, Medium ESP duct fan coil ▪ FWB-B FAN COIL, ACCESSORIES Low sound power levels and electrical absorption thanks to plastic impeller and improved electric motor. Medium ESP duct unit FWB-B FWB**BTN, 2 pipe unit, standard, without valves FWB**BTV, 2 pipe unit, with 3-ways 230V on/off valve, factory mounted FWB**BTNE, 2 pipe unit, without valves and electric heater, factory mounted FWB**BTVE, 2 pipe unit, with 3-ways 230V on/off valve and electric heater, factory mounted Cooling capacity (Total at High Speed) Heating capacity (2-pipe at High Speed) Heating capacity (4-pipe at High Speed) 02 03 04 05 06 07 08 09 10 CZK 12.280,– 13.127,– 13.917,– 16.796,– 17.389,– 19.055,– 22.978,– 24.305,– 25.857,– CZK 16.288,– 17.079,– 17.869,– 20.749,– 21.340,– 22.978,– 27.185,– 28.426,– 30.064,– CZK 19.816,– 20.692,– 21.482,– 25.209,– 25.800,– 27.382,– 31.898,– 33.226,– 34.806,– CZK 23.768,– 24.615,– 25.406,– 29.160,– 29.753,– 31.306,– 36.104,– 37.347,– 39.012,– kW kW kW 2,61 5,47 3,14 3,14 6,01 3,14 3,49 6,47 3,14 5,08 10,31 5,99 5,45 11,39 5,99 6,47 12,28 5,99 7,57 15,05 12,80 8,67 16,85 12,80 10,34 18,78 12,80 03 04 05 06 07 08 09 10 Accessories for FWB-B Additional single row heat exchanger 02 EAH04A6 4.774,– CZK EAH07A6 5.353,– 3-way valve add. h/e E2MV307A6 5.093,– E2MV207A6 2.632,– CZK 2-way valve add. h/e CZK Fan stop thermostat YFSTA6 492,– CZK Controller for FWB-B 02 Controller electronic Standard version CZK Controller electronic Advanced version CZK Controller electronic Advanced Plus version CZK Wall mounting kit (spacing collar) for FWEC*A CZK Temperature sensor kit for FWEC*A CZK Relative humidity sensor kit for FWEC2A and FWEC3A CZK EAH10A6 7.059,– E2MV310A6 5.093,– E2MV210A6 2.778,– 03 04 05 06 FWEC1A 2.546,– FWEC2A 3.993,– FWEC3A 5.439,– FWFCKA 435,– FWTSKA 231,– FWHSKA 607,– EPIMSB6 3.473,– Master / Slave interface CZK 16 07 08 09 10 → FWP - A, Medium ESP duct fan coil with DC fan motor ▪ FWP-A FAN COIL, ACCESSORIES Low sound level and up to 50% energy saving thanks to the BLDC motor technology Medium ESP duct unit with DC fan motor FWP-A FWP**ATN, 2 pipe unit, standard, without valves FWP**ATV, 2 pipe unit, with 3-ways 230V on/off valve, factory mounted FWP**ATNE, 2 pipe unit, without valves and electric heater, factory mounted FWP**ATVE, 2 pipe unit, with 3-ways 230V on/off valve and electric heater, factory mounted Cooling capacity (Total at High Speed) Heating capacity (2-pipe at High Speed) Heating capacity (4-pipe at High Speed) 02 03 04 05 06 07 CZK 17.103,– 17.807,– 18.512,– 21.715,– 21.971,– 23.444,– CZK 20.882,– 21.651,– 22.355,– 25.558,– 25.814,– 27.288,– CZK 24.405,– 25.174,– 25.878,– 29.850,– 30.106,– 31.579,– CZK 28.248,– 29.017,– 29.658,– 33.693,– 33.949,– 35.423,– kW kW kW 2,61 5,47 3,14 3,14 6,01 3,14 3,49 6,47 3,14 5,08 10,31 5,99 5,45 11,39 5,99 6,47 12,28 5,99 03 04 05 06 07 Accessories for FWP-A Additional single row heat exchanger 02 EAH04A6 4.774,– CZK EAH07A6 5.353,– 3-way valve add. h/e E2MV307A6 5.093,– E2MV207A6 2.632,– CZK 2-way valve add. h/e CZK Controller for FWP-A 02 Controller electronic Advanced Plus version CZK Wall mounting kit (spacing collar) for FWEC*A CZK Temperature sensor kit for FWEC*A CZK Relative humidity sensor kit for FWEC2A and FWEC3A CZK 03 04 05 FWEC3A 5.439,– FWFCKA 435,– FWTSKA 231,– FWHSKA 607,– 17 06 07 → FWD - A, High ESP flexi type fan coil ▪ FWD - A FAN COIL, ACCESSORIES Straight duct connector is mounted to discharge side 2-pipe unit FWD**AT Price Cooling capacity (Total at High Speed) Heating capacity (2-pipe at High Speed) 04 06 08 10 12 16 18 CZK kW kW 14.764,– 3,90 4,05 19.506,– 6,20 7,71 22.781,– 7,80 9,43 25.350,– 8,82 10,79 31.503,– 11,90 14,45 40.452,– 16,40 19,81 44.461,– 18,30 21,92 04 06 08 10 12 16 18 CZK kW kW 17.332,– 3,90 4,49 22.639,– 6,20 6,62 26.450,– 7,80 9,21 29.358,– 8,82 9,21 36.952,– 11,90 15,86 46.803,– 16,40 21,15 51.348,– 18,30 21,15 04 06 08 10 12 16 18 EDEH04A6 7.565,– EDEH04A6 7.565,– ED2MV04A6 5.364,– ED4MV04A6 10.275,– EDEHS06A6 14.227,– EDEHB06A6 14.227,– 4-pipe unit FWD**AF Price Cooling capacity (Total at High Speed) Heating capacity (4-pipe at High Speed) Accessories for FWD Electric heater low capacity CZK Electric heater high capacity CZK 2-pipe 3-way valve CZK 4-pipe 3-way valve CZK Vertical drainpan CZK Horizontal drainpan CZK Fan stop thermostat CZK Fresh air intake CZK Controller for FWD EDMFA04A6 25.774,– 04 EDEHS10A6 14.227,– EDEHB10A6 14.227,– ED2MV10A6 5.646,– ED4MV10A6 10.925,– EDDPV10A6 311,– EDDPH10A6 452,– YFSTA6 492,– EDMFA06A6 EDMFA10A6 26.337,– 26.846,– 06 Controller electronic Standard version 08 10 EDEHS12A6 14.538,– EDEHB12A6 14.538,– ED2MV12A6 5.138,– 2 x ED2MV12A6 11.697,– EDMFA12A6 28.454,– 12 FWEC1A CZK 2.546,– FWEC2A CZK 3.993,– FWEC3A CZK 5.439,– Controller electronic Advanced version Controller electronic Advanced Plus version Wall mounting kit (spacing collar) for FWEC*A CZK Temperature sensor kit for FWEC*A CZK Relative humidity sensor kit for FWEC2A and FWEC3A CZK EDEHS18A6 16.344,– EDEHB18A6 16.344,– ED2MV18A6 5.928,– 2 x ED2MV18A6 12.228,– EDDPV18A6 481,– EDDPH18A6 621,– EDMFA18A6 28.849,– 16 FWEC1A EPIB6 requested 2.546,– FWEC2A EPIB6 requested 3.993,– FWEC3A EPIB6 requested 5.439,– FWFCKA 435,– FWTSKA 231,– FWHSKA 607,– EPIMSB6 3.473,– Master / Slave interface CZK Power interface – – CZK Note: For FWD size 12, 16 or 18 EPIB6 needs to be used for each FWD unit to connect to FWEC*A controllers. If FWD size 12, 16 or 18 are used in Master/Slave application by using EPIMSB6 still EPIB6 needs to be used for each FWD to connect to EPIMSB6. 18 EPIB6 4.137,– 18 → FWF-C, FWF-B, FWC-B, Cassette fan coils ▪ FWF-C FAN COIL Infrared remote control as standard with decoration panel kit. FWF-C cassette unit FWF**CT, 2 pipe unit, incl. condensate pump, without valves Cooling capacity (Total at High Speed) Heating capacity (2-pipe at High Speed) 02 03 04 CZK 13.466,– 15.159,– 15.357,– kW kW 2,49 3,52 4,10 4,69 4,54 5,28 Note: Decoration panel is mandatory, it is included with other accessories in table on page 20. ▪ FWF-B FAN COIL Possibility to shut 1 or 2 flaps for easy installations in corners. FWF-B cassette unit FWF**BT, 2 pipe unit, incl. condensate pump, without valves Cooling capacity (Total at Super High Speed) Heating capacity (2-pipe at Super High Speed) FWF**BF, 4 pipe unit, incl. condensate pump, without valves Cooling capacity (Total at Super High Speed) Heating capacity (4-pipe at Super High Speed) 02 03 04 05 CZK 18.663,– 20.427,– 21.961,– 23.148,– kW kW 2,00 2,90 3,20 4,00 4,20 5,40 5,20 6,70 CZK 20.775,– 22.569,– 23.697,– 24.884,– kW kW 2,00 3,80 2,70 3,80 3,50 4,90 4,50 6,10 06 07 08 09 CZK 26.986,– 27.806,– 29.132,– 30.205,– kW kW 5,80 8,00 6,80 8,90 7,70 10,60 8,70 12,10 CZK 28.878,– 29.782,– 30.685,– 31.729,– kW kW 5,80 7,50 6,60 8,40 7,60 9,70 8,70 11,00 Note: Decoration panel is mandatory, it is included with other accessories in table on page 21. ▪ FWC-B FAN COIL 360° air discharge ensures uniform air flow and temperature distribution. FWC-B cassette unit FWC**BT, 2 pipe unit, incl. condensate pump, without valves Cooling capacity (Total at High Speed) Heating capacity (2-pipe at High Speed) FWC**BF, 4 pipe unit, incl. condensate pump, without valves Cooling capacity (Total at High Speed) Heating capacity (4-pipe at High Speed) Note: Decoration panel is mandatory, it is included with other accessories in table on page 21. 19 → FWT-C, Wall mounted fan coil → Accessories for FWT-C, FWF-C ▪ FWT-C FAN COIL Flexibility via interchangeable water connection side. FWT-C wall mounted unit FWT**CT, 2 pipe unit, without valves Cooling capacity (Total at High Speed) Heating capacity (2-pipe at High Speed) 02 03 04 05 06 CZK 8.469,– 9.457,– 9.598,– 13.071,– 13.324,– kW kW 2,34 3,02 2,78 3,75 3,22 4,10 4,54 6,01 5,28 6,74 ▪ FWT-C + FWF-C ACCESSORIES Type Decoration panel 2-pipe Incl. wireless controller CZK FWF-CT FWT-CT DCP600TC 4.654,– – Standard wired remote control MERCA 3.669,– SRC-COA 1.863,– SRC-HPA 1.863,– WRC-HPC 734,– CZK Simplified wired remote control CZK Simplified wired remote control CZK Wireless control CZK 2-pipe 3-way valve CZK MCKCW2T3VN 3.388,– 20 – → Accessories for FWC-B, FWF-B ▪ FWC-B, FWF-B ACCESSORIES Options Decoration Panel Round Flow Standard CZK Decoration Panel 4-way blow CZK Sealing member of air discharge outlet CZK Long-life filter CZK Panel spacer CZK Fresh air intake kit CZK FWC-B FWF-B BYCQ140C 7.350,– - CE.KDDQ55C140 15.335,– BYFQ60B 4.832,– KDBH44BA60 3.963,– KAFQ441BA60 on request KDBQ44B60 13.542,– KDDQ44XA60 4.543,– BRC7F532F (11) 4.948,– BRC7F533F (11) 3.502,– BRC7E530 (11) 4.971,– BRC7E531 (11) 8.189,– KDBHQ55C140 3.010,– KAFP551K160 2.865,– - Control Systems Remote control Infrared H/P CZK Remote control Infrared C/O CZK Remote Control Wired BRC315D (1) 3.153,– DCS302C51 (2) 48.176,– KJB311A 2.228,– DCS301B51 (5) 20.283,– KJB212A 2.141,– DST301B51 (5)(8) 25.346,– KRP2A52 (4)(8) 9.837,– KRP4A53 (4)(8) 4.977,– CZK Central remote control CZK Electrical box with earth terminal (3 blocks) CZK Unified on/off control CZK Electrical box with earth terminal (2 blocks) CZK Shedule timer CZK Wiring adapter for electrical appendices 1 CZK Wiring adapter for electrical appendices 2 CZK Installation box for adapter PCB CZK Remote Sensor CZK KRP1H98 (9) 1.447,– KRCS01-4 2.372,– Intelligent touch controller DCS601C51 (3)(7) 53.495,– KJB411A 3.848,– EKFCMBCB (4)(8) 2.893,– EKMV2C09B (4)(6)(10) 2.401,– EKMV3C09B (4)(6)(10) 2.721,– EKRP1C11 2.230,– CZK Electrical installation box CZK Optional PCB for MOD-bus connection CZK 2-way valve - On/Off CZK 3-way valve - On/Off CZK Valve control PCB CZK Remote “On/Off ” and “forced off ” kit CZK KRP1BA101 (9) 1.919,– KRCS01-1 2.371,– EKRORO (12) 724,– - Notes: 1. Optional, electrical installation box with earth terminal KJB212A is required, if controller wires need to be installed in the wall. 2. Requires electrical installation box with earth terminal KJB311A. 3. Requires electrical installation box KJB411A. 4. Requires installation box KRP1H98 for FWC-B and KRP1BA101 for FWF-B. 5. Requires electrical installation box with earth terminal KJB212A, if built in the wall. 6. Requires valve control PCB EKRP1C11. 7. I-touch: • Not allowed to use the i-touch for an installation with both fan coils and VRV units. • Can not be used in combination with fan coil units, that use MOD bus communication. • No Airnet or telephone connection possible. 8. Only 1 of these 4 options can be installed on 1 indoor unit. 9. FWC -B: Max. 1 KRP1H98 box can be mounted on the unit. Max. 2 PCB’s can be mounted in 1 KRP1H98 box. FWF-B: Max. 2 KRP1BA101 boxes can be mounted on the unit. Max. 1 PCB can be mounted in 1 KRP1BA101 box. 10. FWC-B - 2-pipe unit: 1 x valve kit + 1 x installation box for PCB KRP1H98 + 1 x valve control PCB EKRP1C11 FWC-B - 4-pipe unit: 2 x valve kit + 1 x installation box for PCB KRP1H98 + 1 x valve control PCB EKRP1C11 FWF-B - 2-pipe unit: 1 x valve kit + 1 x installation box for PCB KRP1BA101 + 1 x valve control PCB EKRP1C11. FWF-B - 4-pipe unit: 2 x valve kit + 1 x installation box for PCB KRP1BA101 + 1 x valve control PCB EKRP1C11. 11. It is possible to change the operation mode, but this will not have an impact on the water temperature. (No feed back to water source) It is not possible to select the “auto air flow” setting. Dry operation can be selected with this remote control, but this function is not available on the FWC-B / FWF-B model. 12. This option is needed to create T1 T2 wire. All options are supplied as kit. 21 → FWV - D, Floor standing fan coil ▪ FWV - D FAN COIL Low Wall unit FWV FWV**DTN, 2 pipe unit, standard, without valve FWV**DTV, 2 pipe unit, with 3-way on/off 230V valve, factory mounted FWV**DTD, 2 pipe unit, with simplified 3-way on/off 230V valve, factory mounted Cooling capacity (Total) Heating capacity (2-pipe at High Speed) FWV**DFN, 4 pipe unit, standard, without valves FWV**DFV, 4 pipe unit, with 3-way on/off 230V valves, factory mounted FWV**DFD, 4 pipe unit, with simplified 3-way on/off 230V valves, factory mounted Cooling capacity (Total) Heating capacity (4-pipe at High Speed) CZK CZK CZK kW kW CZK CZK CZK kW kW Factory mounted options 3-way on/off 24V valve 3-way proportional on/off valves 2-way on/off 230V valve 2-way on/off 24V valves 2-way proportional on/off valve 4-rows coil (for 2 pipe unit only) 6-speeds fan motor Electric heater (for 2 pipe unit only) CZK CZK CZK CZK CZK CZK CZK CZK Factory mounted options FWEC1A FWEC2A FWEC3A Standard version Advanced version Advanced Plus version 01 15 02 25 03 35 04 06 08 10 8.215,– 8.328,– 9.062,– 9.416,– 9.993,– 10.633,– 11.489,– 12.421,– 16.485,– 18.716,– 13.973,– 13.964,– 14.848,– 14.989,– 15.752,– 16.270,– 17.389,– 18.321,– 22.838,– 25.067,– 10.889,– 11.210,– 11.658,– 12.298,– 12.554,– 13.452,– 14.221,– 15.117,– 19.152,– 21.266,– 1,54 2,14 1,74 2,20 1,96 2,57 2,42 3,20 2,93 3,81 3,51 4,78 4,33 5,10 4,77 5,95 6,71 7,83 8,02 10,03 9.513,– 9.737,– 10.445,– 10.889,– 11.546,– 12.107,– 13.381,– 14.453,– 18.913,– 21.087,– 19.902,– 19.793,– 20.805,– 20.947,– 21.934,– 22.227,– 23.768,– 24.813,– 29.809,– 32.040,– 14.989,– 15.437,– 15.886,– 16.591,– 16.975,– 17.872,– 19.024,– 20.049,– 24.598,– 26.775,– 1,46 1,90 1,69 2,02 1,79 2,01 2,38 2,92 2,87 3,08 3,46 4,80 4,26 5,05 4,67 5,30 6,64 7,91 7,88 8,35 01 15 02 25 03 35 04 06 08 10 - on r. 08 10 on request on request on request on request on request on request on request on request - 01 15 02 CZK CZK CZK 25 03 35 on request on request on request Notes: Accessories as kits are included on page 25. Additional single row h/e (4-row coil) can not be used in combination with electric heater. Independent power supply is necessary for 24 V valve. FWEC1/2/3A are not suitable to control 24 V valve. Controller FWEC3A is necessary for proportional valve. Cooling capacity is related to High Speed, standard unit. 22 04 06 → FWL - D, Flexi type fan coil ▪ FWL - D FAN COIL Flexible unit FWL FWL**DTN, 2 pipe unit, standard, without valve FWL**DTV, 2 pipe unit, with 3-way on/off 230V valve, factory mounted FWL**DTD, 2 pipe unit, with simplified 3-way on/off 230V valve, factory mounted Cooling capacity (Total) Heating capacity (2-pipe at High Speed) FWL**DFN, 4 pipe unit, standard, without valves FWL**DFV, 4 pipe unit, with 3-way on/off 230V valves, factory mounted FWL**DFD, 4 pipe unit, with simplified 3-way on/off 230V valves, factory mounted Cooling capacity (Total) Heating (4-pipe at High Speed) 01 15 02 25 03 35 04 06 08 10 CZK 8.611,– 8.840,– 9.654,– 9.800,– 10.699,– 11.210,– 12.138,– 13.071,– 17.587,– 19.902,– CZK 14.256,– 14.284,– 15.244,– 15.245,– 16.344,– 16.782,– 17.982,– 18.913,– 23.910,– 26.196,– CZK 11.210,– 11.658,– 12.170,– 12.619,– 13.259,– 14.028,– 14.796,– 15.693,– 20.177,– 22.419,– kW kW 1,54 2,14 1,74 2,20 1,96 2,57 2,42 3,20 2,93 3,81 3,51 4,78 4,33 5,10 4,77 5,95 6,71 7,83 8,02 10,03 CZK 10.106,– 10.249,– 10.897,– 11.402,– 12.138,– 13.068,– 14.170,– 15.103,– 20.099,– 22.244,– CZK 20.297,– 20.114,– 21.087,– 21.266,– 22.329,– 22.931,– 24.362,– 25.265,– 30.797,– 32.971,– CZK 15.437,– 15.886,– 16.206,– 17.038,– 17.487,– 18.705,– 19.665,– 20.561,– 25.686,– 27.800,– kW kW 1,46 1,90 1,69 2,02 1,79 2,01 2,38 2,92 2,87 3,08 3,46 4,80 4,26 5,05 4,67 5,30 6,64 7,91 7,88 8,35 01 15 02 25 03 35 04 06 08 10 - on r. 08 10 Factory mounted options 3-way on/off 24V valve 3-way proportional on/off valves 2-way on/off 230V valve 2-way on/off 24V valves 2-way proportional on/off valve 4-rows coil (for 2 pipe unit only) 6-speeds fan motor Electric heater (for 2 pipe unit only) CZK CZK CZK CZK CZK CZK CZK CZK Factory mounted options FWEC1A FWEC2A FWEC3A Standard version Advanced version Advanced Plus version on request on request on request on request on request on request on request on request - 01 15 02 CZK CZK CZK 25 03 35 on request on request on request Notes: Accessories as kits are included on page 25. Additional single row h/e (4-row coil) can not be used in combination with electric heater. Independent power supply is necessary for 24 V valve. FWEC1/2/3A are not suitable to control 24 V valve. Controller FWEC3A is necessary for proportional valve. Cooling capacity is related to High Speed, standard unit. 23 04 06 → FWM - D, Flexi concealed fan coil ▪ FWM - D FAN COIL Flexible concealed unit FWM FWM**DTN, 2 pipe unit, standard, without valve FWM**DTV, 2 pipe unit, with 3-way on/off 230V valve, factory mounted FWM**DTD, 2 pipe unit, with simplified 3-way on/off 230V valve, factory mounted Cooling capacity (Total) Heating capacity (2-pipe at High Speed) "FWM**DFN, 4 pipe unit, standard, without valves FWM**DFV, 4 pipe unit, with 3-way on/off 230V valves, factory mounted FWM**DFD, 4 pipe unit, with simplified 3-way on/off 230V valves, factory mounted Cooling capacity (Total) Heating capacity (4-pipe at High Speed) CZK CZK CZK kW kW CZK CZK CZK kW kW Factory mounted options 3-way on/off 24V valve 3-way proportional on/off valves 2-way on/off 230V valve 2-way on/off 24V valves 2-way proportional on/off valve 4-rows coil (for 2 pipe unit only) 6-speeds fan motor Electric heater (for 2 pipe unit only) CZK CZK CZK CZK CZK CZK CZK CZK 01 15 02 25 03 35 04 06 08 10 6.965,– 7.511,– 7.684,– 8.346,– 8.490,– 9.210,– 9.584,– 10.448,– 13.786,– 15.656,– 12.720,– 13.239,– 13.469,– 14.101,– 14.247,– 15.109,– 15.455,– 16.405,– 20.203,– 22.017,– 10.178,– 10.724,– 10.898,– 11.559,– 11.703,– 12.422,– 13.065,– 13.928,– 17.401,– 19.337,– 1,54 2,14 1,74 2,20 1,96 2,57 2,42 3,20 2,93 3,81 3,51 4,78 4,33 5,10 4,77 5,95 6,71 7,83 8,02 10,03 8.375,– 8.777,– 8.980,– 9.497,– 10.102,– 11.022,– 11.569,– 12.375,– 16.203,– 18.131,– 18.736,– 18.994,– 19.339,– 20.002,– 20.490,– 21.153,– 21.959,– 22.765,– 27.110,– 29.039,– 14.667,– 15.070,– 15.272,– 15.789,– 16.394,– 17.315,– 18.264,– 19.002,– 23.165,– 25.159,– 1,46 1,90 1,69 2,02 1,79 2,01 2,38 2,92 2,87 3,08 3,46 4,80 4,26 5,05 4,67 5,30 6,64 7,91 7,88 8,35 01 15 02 25 03 35 04 06 08 10 - on r. on request on request on request on request on request on request on request on request - Notes: Accessories as kits are included on page 25. Additional single row h/e (4-row coil) can not be used in combination with electric heater. Independent power supply is necessary for 24 V valve. FWEC1/2/3A are not suitable to control 24 V valve. Controller FWEC3A is necessary for proportional valve. Cooling capacity is related to High Speed, standard unit. 24 → Accessories for FWV - FWL - FWM ▪ FWV – FWL – FWM ACCESSORIES Accessories as a kit for FWV/FWL/FWM 1 Additional heat exchanger CZK Electric heater CZK 15 2-pipe 3-ways 230V on/off valve kit CZK 4-pipe 3-ways 230V on/off valve kit CZK 2-ways 230V on/off valve kit cooling h/e CZK 2-ways 230V on/off valve kit additional h/e CZK 2-pipe simplified 3-ways 230V on/off valve kit CZK 4-pipe simplified 3-ways 230V on/off valve kit CZK 2-pipe 3-ways 24V on/off valve kit CZK 4-pipe 3-ways 24V on/off valve kit CZK 2-pipe 3-ways proportional valve kit CZK 4-pipe 3-ways proportional valve kit CZK 2-ways 24V on/off valve kit cooling h/e CZK 2-ways 24V on/off valve kit additional h/e CZK 2-ways proportional valve kit cooling h/e CZK 2-ways proportional valve kit additional h/e CZK Fan stop thermostat CZK Air intake & discharge grille CZK EAIDF02A6 4.629,– Supporting feet CZK Supporting feet & grille CZK Fresh air intake CZK Rear panel CZK Plenum box with circular connections (only for FWM-D) CZK Vertical auxiliary drainpan CZK Horizontal auxiliary drainpan CZK 2 ESRH02A6 1.591,– EEH01A6 EEH02A6 7.175,– 7.175,– ESFVG02A6 810,– EFA02A6 2.026,– ERPV02A6 867,– EPCC02A6 2.521,– 3 35 ESRH03A6 1.910,– EEH03A6 7.696,– E2MV03A6 5.006,– E4MV03A6 9.372,– E2MV2B07A6 2.632,– E2MV2B07A6 2.632,– E2MVD03A6 3.338,– E4MVD03A6 6.131,– E2M2V03A6 5.722,– E4M2V03A6 10.218,– E2MPV03A6 8.991,– E4MPV03A6 16.553,– E2M2V207A6 2.453,– E2M2V207A6 2.453,– E2MPV207A6 6.266,– E2MPV207A6 6.266,– YFSTA6 492,– EAIDF03A6 5.699,– ESFV06A6 492,– ESFVG03A6 984,– EFA03A6 2.055,– ERPV03A6 1.187,– EPCC03A6 2.793,– EDPVB6 138,– EDPHB6 138,– Controller as a kit for FWV/FWL/FWM ECFWMB6 Controller electromechanical, Built in FWEC1A Wired remote controller, Standard version FWEC2A Wired remote controller, Advanced version FWEC3A Wired remote controller, Advanced Plus version FWECKA On board mounting kit, for FWEC*A, remote airprobe incl. FWFCKA Wall mounting kit (spacing collar), for FWEC*A FWTSKA Temperature sensor kit , for FWEC*A FWHSKA Relative humidity sensor kit , for FWEC2A and FWEC3A EPIMSB6 Master / Slave interface 25 all sizes CZK CZK CZK 1.012,– 2.546,– 3.993,– CZK 5.439,– CZK 435,– CZK CZK CZK 435,– 231,– 607,– CZK 3.473,– 25 4 6 ESRH06A6 2.112,– EEH06A6 8.015,– E2MV06A6 5.353,– E4MV06A6 9.767,– E2MVD06A6 3.406,– E4MVD06A6 6.266,– E2M2V06A6 5.722,– E4M2V06A6 10.218,– E2MPV06A6 8.856,– E4MPV06A6 16.621,– 8 10 ESRH10A6 2.807,– EEH10A6 8.333,– E2MV10A6 5.788,– E4MV10A6 10.219,– E2MV2B10A6 2.778,– E2MVD10A6 3.406,– E4MVD10A6 6.335,– E2M2V10A6 6.063,– E4M2V10A6 10.763,– E2MPV10A6 9.128,– E4MPV10A6 16.825,– E2M2V210A6 2.453,– E2MPV210A6 6.266,– EAIDF06A6 7.118,– ESFVG06A6 1.128,– EFA06A6 2.286,– ERPV06A6 1.331,– EPCC06A6 3.474,– EAIDF10A6 8.420,– ESFV10A6 607,– ESFVG10A6 1.562,– EFA10A6 2.604,– ERPV10A6 1.707,– EPCC10A6 4.837,– → FWZ - A, Floor standing fan coil with DC fan motor ▪ FWZ - A FAN COIL Low sound level and up to 70% energy saving thanks to the BLDC motor technology Low Wall unit with DC fan motor FWZ FWZ**ATN, 2 pipe unit, standard, without valve FWZ**ATV, 2 pipe unit, with 3-way on/off 230V valve, factory mounted FWZ**ATD, 2 pipe unit, with simplified 3-way on/off 230V valve, factory mounted Cooling capacity (Total) Heating capacity (2-pipe at High Speed) FWZ**AFN, 4 pipe unit, standard, without valves FWZ**AFV, 4 pipe unit, with 3-way on/off 230V valves, factory mounted FWZ**AFD, 4 pipe unit, with simplified 3-way on/off 230V valves, factory mounted Cooling capacity (Total) Heating capacity (4-pipe at High Speed) CZK CZK CZK kW kW CZK CZK CZK kW kW Factory mounted options 3-way on/off 24V valve 2-way on/off 230V valve 2-way on/off 24V valves 4-rows coil (for 2 pipe unit only) Electric heater (for 2 pipe unit only) Advanced Plus version 03 06 08 13.259,– 14.028,– 16.206,– 20.242,– 18.704,– 19.473,– 21.843,– 26.327,– 16.078,– 16.847,– 19.153,– 23.380,– 2,64 3,47 4,96 6,40 6,32 7,51 10,08 11,18 14.412,– 15.309,– 18.192,– 22.291,– 24.277,– 25.174,– 28.056,– 32.732,– 20.049,– 20.946,– 24.085,– 28.505,– 2,43 2,46 4,96 4,19 6,32 6,45 10,08 10,06 02 03 06 08 06 08 CZK CZK CZK CZK CZK Factory mounted options FWEC3A 02 on request on request on request on request on request 02 03 CZK on request Notes: Accessories as kits are included on page 29. Additional single row h/e (4-row coil) can not be used in combination with electric heater. Independent power supply is necessary for 24 V valve. FWEC3A are not suitable to control 24 V valve. Controller FWEC3A is necessary to control DC fan motor. Cooling capacity is related to High Speed, standard unit. 26 → FWR - A, Flexi type fan coil with DC fan motor ▪ FWR - A FAN COIL Low sound level and up to 70% energy saving thanks to the BLDC motor technology FLEXI type unit with DC fan motor FWR FWR**ATN, 2 pipe unit, standard, without valve FWR**ATV, 2 pipe unit, with 3-way on/off 230V valve, factory mounted FWR**ATD, 2 pipe unit, with simplified 3-way on/off 230V valve, factory mounted Cooling capacity (Total) Heating capacity (2-pipe at High Speed) FWR**AFN, 4 pipe unit, standard, without valves FWR**AFV, 4 pipe unit, with 3-way on/off 230V valves, factory mounted FWR**AFD, 4 pipe unit, with simplified 3-way on/off 230V valves, factory mounted Cooling capacity (Total) Heating capacity (4-pipe at High Speed) 02 03 06 08 CZK 13.836,– 14.989,– 17.295,– 22.099,– CZK 19.281,– 20.434,– 22.932,– 28.184,– CZK 16.654,– 17.807,– 20.242,– 25.174,– kW kW 2,64 3,47 4,96 6,40 6,32 7,51 10,08 11,18 CZK 15.117,– 16.334,– 19.153,– 24.341,– CZK 24.982,– 26.199,– 29.081,– 34.782,– CZK 20.754,– 21.971,– 25.110,– 30.554,– kW kW 2,43 2,46 4,96 4,19 6,32 6,45 10,08 10,06 02 03 06 08 06 08 Factory mounted options 3-way on/off 24V valve 2-way on/off 230V valve 2-way on/off 24V valves 4-rows coil (for 2 pipe unit only) Electric heater (for 2 pipe unit only) CZK CZK CZK CZK CZK Factory mounted options FWEC3A Advanced Plus version on request on request on request on request on request 02 03 CZK on request Notes: Accessories as kits are included on page 29. Additional single row h/e (4-row coil) can not be used in combination with electric heater. Independent power supply is necessary for 24 V valve. FWEC1/2/3A are not suitable to control 24 V valve. Controller FWEC3A is necessary to control DC fan motor. Cooling capacity is related to High Speed, standard unit. 27 → FWS - A, Flexi type fan coil with DC fan motor ▪ FWS - A FAN COIL Low sound level and up to 70% energy saving thanks to the BLDC motor technology FLEXI type unit with DC fan motor FWS FWS**ATN 2 pipe unit, standard, without valve FWS**ATV, 2 pipe unit, with 3-way on/off 230V valve, factory mounted FWS**ATD, 2 pipe unit, with simplified 3-way on/off 230V valve, factory mounted Cooling capacity (Total) Heating capacity (2-pipe at High Speed) FWS**AFN 4 pipe unit, standard, without valves FWS**AFV 4 pipe unit, with 3-way on/off 230V valves, factory mounted FWS**AFD, 4 pipe unit, with simplified 3-way on/off 230V valves, factory mounted Cooling capacity (Total) Heating capacity (4-pipe at High Speed) CZK CZK CZK kW kW CZK CZK CZK kW kW Factory mounted options 3-way on/off 24V valve 2-way on/off 230V valve 2-way on/off 24V valves 4-rows coil (for 2 pipe unit only) Electric heater (for 2 pipe unit only) Advanced Plus version 03 06 08 11.850,– 12.683,– 14.541,– 18.128,– 17.359,– 18.128,– 20.177,– 24.213,– 14.669,– 15.501,– 17.551,– 21.266,– 2,64 3,47 4,96 6,40 6,32 7,51 10,08 11,18 13.067,– 14.220,– 16.334,– 20.370,– 22.996,– 24.085,– 26.199,– 30.811,– 18.704,– 19.857,– 22.227,– 26.519,– 2,43 2,46 4,96 4,19 6,32 6,45 10,08 10,06 02 03 06 08 06 08 CZK CZK CZK CZK CZK Factory mounted options FWEC3A 02 on request on request on request on request on request 02 03 CZK on request Notes: Accessories as kits are included on page 29. Additional single row h/e (4-row coil) can not be used in combination with electric heater. Independent power supply is necessary for 24 V valve. FWEC3A are not suitable to control 24 V valve. Controller FWEC3A is necessary to control DC fan motor. Cooling capacity is related to High Speed, standard unit. 28 → Accessories for FWZ - FWR - FWS ▪ FWZ - FWR - FWS ACCESSORIES Accessories as a kit for FWZ/FWR/FWS Additional heat exchanger CZK Electric heater CZK 02 03 06 08 ESRH02A6 1.591,– EEH02A6 7.175,– ESRH03A6 1.910,– EEH03A6 7.696,– ESRH06A6 2.112,– EEH06A6 8.015,– E2MV06A6 5.353,– E4MV06A6 9.767,– ESRH10A6 2.807,– EEH10A6 8.333,– E2MV10A6 5.788,– E4MV10A6 10.219,– E2MV2B10A6 2.778,– E2MVD06A6 3.406,– E4MVD06A6 6.266,– E2M2V06A6 5.722,– E4M2V06A6 10.218,– E2MVD10A6 3.406,– E4MVD10A6 6.335,– E2M2V10A6 6.063,– E4M2V10A6 10.763,– E2M2V210A6 2.453,– EAIDF06A6 7.118,– EAIDF10A6 8.420,– ESFV10A6 607,– ESFVG10A6 1.562,– EFA10A6 2.604,– ERPV10A6 1.707,– EPCC10A6 4.837,– 2-pipe 3-ways 230V on/off valve kit E2MV03A6 5.006,– E4MV03A6 9.372,– CZK 4-pipe 3-ways 230V on/off valve kit CZK 2-ways 230V on/off valve kit cooling h/e E2MV2B07A6 2.632,– CZK 2-ways 230V on/off valve kit additional h/e E2MV2B07A6 2.632,– CZK 2-pipe simplified 3-ways 230V on/off valve kit E2MVD03A6 3.338,– E4MVD03A6 6.131,– E2M2V03A6 5.722,– E4M2V03A6 10.218,– CZK 4-pipe simplified 3-ways 230V on/off valve kit CZK 2-pipe 3-ways 24V on/off valve kit CZK 4-pipe 3-ways 24V on/off valve kit CZK 2-ways 24V on/off valve kit cooling h/e E2M2V207A6 2.453,– CZK 2-ways 24V on/off valve kit additional h/e E2M2V207A6 2.453,– CZK Air intake & discharge grille CZK EAIDF02A6 4.629,– EAIDF03A6 5.699,– ESFV06A6 492,– ESFVG03A6 984,– EFA03A6 2.055,– ERPV03A6 1.187,– EPCC03A6 2.793,– Supporting feet CZK Supporting feet & grille CZK Fresh air intake CZK Rear panel CZK Plenum box with circular connections (only for FWS-A) CZK ESFVG02A6 810,– EFA02A6 2.026,– ERPV02A6 867,– EPCC02A6 2.521,– Vertical auxiliary drainpan EDPVB6 138,– EDPHB6 138,– CZK Horizontal auxiliary drainpan CZK Controller as a kit for FWZ / FWR / FWS FWEC3A FWECKA FW FCKA FWTSKA FWHSKA Wired remote controller, Advanced Plus version On board mounting kit, for FWEC*A, remote airprobe incl. Wall mounting kit (spacing collar), for FWEC*A Temperature sensor kit, for FWEC*A Relative humidity sensor kit , for FWEC2A and FWEC3A ESFVG06A6 1.128,– EFA06A6 2.286,– ERPV06A6 1.331,– EPCC06A6 3.474,– all sizes CZK 5.439,– CZK 435,– CZK 435,– CZK 231,– CZK 607,– 29 → Overview: Air cooled chiller portfolio Extra low Reduced Low Standard Sound version High ambient Premium High Standard Efficiency version Screw Scroll Swing Free cooling Inverter Refrigerant Compressor INVERTER Cooling only 0 EWAQ~ADVP R-410A 3 EWAQ~ACV3/ACW1 R-410A 3 EUWA*~KBZW1 R-407C EWAQ~BA* R-410A EWAQ~DAYN 3 3 3 3 3 3 3 3 3 3 3 R-410A 3 3 3 EWAQ~E- R-410A 3 EWAQ~F- R-410A 3 EWAQ~GZ NEW R-410A EWAD~E- R-134a 3 3 EWAD~D- R-134a 3 3 3 EWAD~BZ R-134a 3 3 3 R-134a 3 3 3 EWAD~TZ NEW * 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 R-134a 3 3 3 3 Heat pump 0 EWYQ~ADVP R-410A 3 3 3 EWYQ~ACV3/ACW1 R-410A 3 3 3 3 EUWY*~KBZW1 R-407C 3 3 3 EWYQ~BA* R-410A 3 3 3 EWYQ~DAYN R-410A 3 3 3 EWYQ~F NEW R-410A 3 3 3 EWYQ~GZ NEW R-410A 3 3 3 3 EWYD~BZ R-134a 3 3 3 3 3 3 3 3 3 3 3 3 3 3 Condensing unit ERAD~E- 3 3 3 3 3 3 3 R-134a R-134a 3 3 EWAD~CZ EWAD~CF 3 3 R-134a * 3 3 EWAD~C- EWAD~DZ COMING SOON 3 0 R-134a * : preliminary 30 Capacity classes (kW) 17,5 200 500 1.000 2.000 5,2~ 7,1 8,6~17,0 11,2~56,1 16,6~64,5 79,4~256 172~334 165~672 80~350 98~411 177~620 328~513 200~700 617~2.008 631~1.795 540~1.785 602~1.555 17,5 200 500 1.000 2.000 500 1.000 2.000 5,2~7,1 5,65~7,75 8,5~17,0 9,9~14,8 9,05~50,9 11,4~54,2 16,6~64,5 16,2~63,7 76,6~254 86,5~283 158~624 173~674 80~350 80~350 247~580 271~618 17.5 200 116~488 31 → Overview: Portfolio Water cooled and Condenserless units Sound version Standard High Standard Efficiency version Centrifugal Screw Scroll Inverter Refrigerant Compressor INVERTER Water cooled chillers (Cooling only & Heating only) 3 3 3 3 3 R-134a 3 3 3 3 EWWD~I- R-134a 3 3 3 3 EWWD~H- R-134a 3 3 3 R-410A 3 3 3 EWWP~KBW1N R-407C EWWD~J- R-134a EWWD~G- 3 Water cooled chillers (Cooling only) EWWQ~B- 3 Condenserless chillers 3 3 3 3 3 R-134a 3 3 3 R-134a 3 3 3 EWLP~KBW1N R-407C EWLD~J- R-134a EWLD~GEWLD~I- 3 Water cooled centrifugal chillers EWWD~FZ R-134a 3 3 3 3 DWME R-134a 3 3 3 3 DWSC DWDC R-134a optional 3 3 3 6.000 RT NEW CENTRIFUGAL R-134a 3 3 3 ▪ Large Chillers options and accessories summary Depending on the type and size of chiller a wide range of options and accessories is available. E.g. Brine (glycol) application Flow switch for evaporator Dual set point possibility Star delta compressor starter (kit for field installation) Set point reset and demand limit possibility Thermal relays for compressors Victaulic connections General fault contact Thermal relays for fans Rubber type ant vibration mounts Single pump Under/over voltage controller Evaporator heater Twin pump Phase monitor device Main switch Total heat recovery Condenser coils with special Suction and discharge stop valves Partial heat recovery anti corrosion treatment on compressors Low ambient application 32 Capacity classes (kW) 0 17,5 200 500 1.000 2.000 21.800 1.000 2.000 21.800 1.000 2.000 21.800 1.000 2.000 21.800 12,9~194 16,7~249 120~568 142~681 165~602 221~785 332~1.503 424~1.951 368~1.212 454~1.488 0 17,5 200 500 379~2.156 0 17,5 200 500 12,1~62,4 109~528 160~524 315~1.433 0 17,5 200 500 316~1.054 1.400~ 1.900 300~4.500 600~9.000 [ 2 x 10.900 ] 21.800 Daikin Europe N.V. participates in the Eurovent Certification programme for Air conditioners (AC), Liquid Chilling Packages (LCP), Air handling units (AHU) and Fan coil units (FCU), Check ongoing validity of certificate online: www.eurovent-certification.com or using: www.certiflash.com Air cooled: Eurovent certified up to 600kW Water cooled: Eurovent certified up to 1500kW Nominal cooling capacities are based on Eurovent conditions: Evaporator: 12°C/7°C — Ambient: 35°C Nominal heating capacities are based on Eurovent conditions: Ambient: 7°CDB/6°CWB — Condenser: 40°C/45°C Power factor 0.9 correction device High ESP fans Plant Watch PRO monitoring system A/V meter Cu/Ni heat exchanger Remote user interface Coil guards Dual pressure relieves safety valves Soft starter Different address card Low noise version Different bus communication gateways (LonTalk, Refrigerant Gauges Bacnet, Modbus,…) For the exact availability of the chiller which fits best Coil guards Chiller Sequencing Panel your application please get in contact with your Cu/Cu condenser coils Different Modems (fixed and GSM) Daikin sales responsible. 33 → Total solution products ▪ AIR COOLER ▪ COOLING TOWER On request we can offer you the most suitable air cooler for your application based on a brine/water solution. On request we can offer you the most suitable cooling tower for your application. For correct selection we need following info: 1-162 KW ▪ 70-9.200 KW • Heat rejection capacity (kW) or chiller type and working conditions • Liquid inlet and outlet temperature • Liquid type • Maximum/Minimum ambient temperature • Maximum sound level • Space restrictions AIR HANDLING UNIT 3 500-140.000 M /H On request we can offer you the most suitable air handling unit for your application. • Air handling units for filtering, heating, cooling, humidifying, and air drying • Air handling units with heat recovery • Air handling units for outdoor installation • Air handling units in hygienic execution for hospital and clean room • Air handling units with indirect gas fired heating • Air handling units for swimming pool applications • Air handling units with higher air volumes manufactured on request • Air handling units with thermal uncoupled frame ▪ COMPRESSOR INSPECTION/REPAIR/OVERHAUL To extend the lifetime of your compressor, Daikin offers a compressor overhaul service as preventive maintenance. In case of broken compressor, Daikin can offer an inspection to determine whether the compressor is repairable or not. Based on the findings the broken parts will be replaced and the compressor will be restored into operational condition. ▪ DRY COOLER & CONDENSER 3-2.400 KW On request we can offer you the most suitable dry cooler and condenser for your application. For correct selection we need following info: Inspection Inspection fee/compressor* on request • Heat rejection capacity (kW) or chiller type and working conditions • Liquid inlet and outlet temperature (dry cooler) • Liquid type (dry cooler) • Condensing temperature (condenser) • Refrigerant type and number of circuits (condenser) • Maximum/Minimum ambient temperature • Maximum sound level • Space restrictions Repair Repair cost/compressor* After inspection, on quotation base Overhaul Overhaul cost/compressor* on request Remarks The above is only valid for DAIKIN semi-hermetic compressors * Excluding transport cost and other site related costs → Measuring conditions Mentioned Capacities, Efficiency Ratios, Sound power levels, Dimensions, Weights are indicative and valid under the following conditions: Chillers Air cooled units Condenserless units Water cooled units Cooling Heating Heat recovery Cooling Cooling Heating 7 °C / 12 °C water 40 °C / 45 °C water 7 °C / 12 °C water 7 °C / 12 °C water 7 °C / 12 °C evaporator water 7 °C / 12 °C evaporator water 35 °C ambient temp 7 °C ambient temp 35 °C ambient temp 40°C / 45°C heat recovery 45 °C condensing temp / 5 K subcooling 30 °C / 35 °C condenser water 40 °C / 45 °C condenser water Cooling: Heating: indoor temperature: 27 °C db / 19 °C wb indoor temperature: 20 °C db outdoor temperature: 35 °C outdoor temperature: 7 °C db / 6 °C wb Cooling: Heating: General: evaporation temperature: 6 °C condensing temperature: 46 °C evaporator superheat: 5K condenser sub-cool: 3K 7,5 m equivalent refrigerant piping 0 m level difference outdoor temperature: 35 °C outdoor temperature: 7 °C Cooling: Room temperature DB/WB: 27 °C/19 °C Entering/Leaving water temperature: 7 °C/12 °C Room temperature: 20 °C Entering water temperature: 50 °C (2-pipe,water flow rate same as for the cooling) / 70 °C (4-pipe, water temperature leaving 60°C) Rooftops Condensing units on-coil temperature: 27 °CDB / 19 °CWB on-coil temperature: 20 °CDB Fan coil units Heating: 34 → Všeobecné obchodní podmínky I. OBECNÁ USTANOVENÍ 1. Všechna práva a povinnosti ze smluv, v nichž má společnost DAIKIN AIRCONDITIONING CENTRAL EUROPE – CZECH REPUBLIC spol. s r.o., se sídlem Praha 8, Pobřežní 3, PSČ 186 00, IČ: 480 39 497, zapsaná v obchodním rejstříku vedeném Městským soudem v Praze, oddílu C, vložce 15503 (dále jen „DAIKIN“) postavení prodávajícího (dodavatele), a druhá smluvní strana postavení kupujícího (objednatele) (dále jen „zákazník“), jejichž předmětem je prodej (dodání) jakéhokoliv zboží (dále souhrnně jen „zboží“) DAIKINem zákazníkovi, které nejsou odchylně upraveny příslušnou smlouvou, se řídí těmito všeobecnými obchodními podmínkami. 2. Pro dodávky a plnění DAIKIN jsou rozhodující výhradně níže uvedené všeobecné obchodní podmínky DAIKIN. Potvrzení zákazníka s odkazem na jeho obchodní nebo nákupní podmínky jsou aplikovatelné pouze v rozsahu, v jakém jsou shodné s těmito všeobecnými obchodními podmínkami. Odchylné doplňky a změny vyžadují ke své právní účinnosti výslovný souhlas DAIKIN a písemnou formu. 3. Tyto Všeobecné obchodní podmínky je možné si stáhnout na domovské stránce www.daikin.cz, jmenovitě na odkazu (Všeobecné obchodní podmínky) „VOP“. 4. K iniciování procesu uzavření smlouvy na dodávku zboží mezi DAIKINem a zákazníkem může dojít jedním z následujících způsobů: i. písemnou (dopisem, faxem nebo e-mailem) nabídkou DAIKINu na dodání zboží doručenou zákazníkovi; a/nebo ii. písemnou (dopisem, faxem nebo e-mailem) objednávkou zboží zákazníka doručenou DAIKINu. 5. Zákazník uzavřením smlouvy s DAIKINem výslovně přijímá veškerá ustanovení těchto všeobecných obchodních podmínek. Pro vyloučení pochybností se vylučuje uplatnění ustanovení § 1799 a 1800 zákona č. 89/2012 Sb., občanského zákoníku, ve znění pozdějších předpisů (dále jen „občanský zákoník“). Veškerá ujednání v rámci konkrétní smlouvy odpovídají obchodním zvyklostem a zásadě poctivého obchodního styku. 7. DAIKIN je oprávněn účtovat zákazníkovi náklady vzniklé prodlením s převzetím zboží, zejména, ale nikoliv pouze, náklady na skladování (skladné 250,-Kč / 1 paleta zboží/1 týden), marné jízdy a dopravné dle tarifů k přepravě zboží použitého přepravce. VIII. VÝHRADA VLASTNICTVÍ 1. Dodané zboží zůstává vlastnictvím DAIKINu až do úplného zaplacení ceny zboží zákazníkem. 2. Zákazník je povinen písemně upozornit každou třetí osobu, která by chtěla nakládat a/nebo nakládá se zbožím (a to jak v právním, tak i faktickém smyslu), k němuž má DAIKIN výhradu vlastnictví, že toto zboží je ve vlastnictví DAIKINu a zabránit třetí osobě v nakládání s takovým zbožím. 3. Zákazník není rovněž oprávněn se zbožím s výhradou vlastnictví DAIKIN nakládat jiným způsobem neslučitelným s výhradou vlastnictví DAIKIN (např.: zajišťovací převod vlastnického práva, zastavení zboží). 4. O zabavení nebo jiných omezeních zboží s výhradou vlastnictví DAIKINu je zákazník povinen DAIKIN bez zytečného odkladu, nejpozději však do následujícího pracovního dne, písemně vyrozumět. Jakékoliv související náklady hradí zákazník. 5. Uplatnění § 2133 občanského zákoníku se vylučuje. IX. ZÁRUKA A ODPOVĚDNOST A. Za vady příp. absenci garantovaných vlastností odpovídá DAIKIN s vyloučením dalších nároků, není-li v konkrétním případě se zákazníkem písemně dohodnuto jinak, takto: 1. Záruční doba činí – není-li dále uvedeno jinak - 36 měsíců ode dne dodání zboží. 2. Záruka je poskytována a zákazník má nárok na záruční plnění pouze za předpokladu, že zboží dodané DAIKINem zákazníkovi je instalováno a zároveň uvedeno do provozu přímo společností DAIKIN či osobou vyškolenou a písemně pověřenou k provádění těchto činností společností DAIKIN, a to v souladu s návodem DAIKIN, a zároveň je bez výjimky dodržován pravidelný servis a údržba zboží v souladu se servisními pokyny společnosti DAIKIN. U chladicích jednotek se spirálovými kompresory typu EWAQ-E/EWAQ-F a se šroubovými kompresory je, není-li dohodnuto jinak, zákazníkovi poskytována záruka v délce 12 měsíců, a to pouze v případě, když uvedení do provozu provádí společnost DAIKIN sama – v opačném případě není poskytována zákazníkovi žádná záruka. U produktů označených „J&E Hall International for Daikin“ je zákazníkovi poskytována záruka v délce 18 měsíců. U produktů označených „Rotex“ činí zákazníkovi poskytovaná záruka obecně 24 měsíců, avšak s následující výjimkami: na produkty Rotex HPSU je zákazníkovi poskytnuta materiálová záruka 24 měsíců od data uvedení do provozu, maximálně však 27 měsíců od data fakturace s tím, že v případě pravidelné údržby a servisu dle pokynů DAIKINu dostupných na domovské internetové stránce www.daikin.cz se poskytuje zákazníkovi prodloužená záruka 60 měsíců od uvedení do provozu, maximálně však 63 měsíců od data fakturace. Pravidla záruky uvedená v předchozí větě za dvojtečkou se aplikují rovněž na produkty označené jako Daikin Altherma, avšak u produktů označených jako Daikin Altherma Flex pouze tehdy, pokud toto zařízení uvede do provozu DAIKIN sama. Materiálovou zárukou se pro účely těchto Všeobecných obchodních podmínek rozumí: Dodávka originálních dílů Daikin přesně specifikovaných dle technických parametrů zařízení a spol. DAIKIN odsouhlasených. 3. V případě vad zboží, na něž se vztahuje záruka, se DAIKIN zavazuje, že vadné zboží příp. vadné díly podle volby DAIKIN vymění nebo opraví. Nároky na záruční plnění nad rámec těchto Všeobecných obchodních podmínek nebo jakékoli jiné nároky ze záruky neexistují. Pracovní doba, doba strávená na cestě nebo jiné náklady se nenahrazují. 4. Záruka a/nebo odpovědnost DAIKINu jsou vyloučeny, jestliže zákazník písemně neoznámí zjevné vady zboží do 3 pracovních dnů po dodání zboží, ostatní vady bez zbytečného odkladu po zjištění. 5. Záruka a/nebo odpovědnost DAIKIN je navíc k případům uvedeným v odst. 2. a 4. vyloučena zejména v případě vad zboží, které vznikly nevhodným nebo neodborným užíváním nebo zacházením se zbožím, nedodržováním provozních podmínek nebo servisních směrnic, nadměrným namáháním nebo nevhodnými provozními prostředky nebo nevhodnými výměnnými látkami. 6. K provedení veškerých nutných záručních zásahů musí být DAIKINu ze strany zákazníka poskytnut potřebný čas a součinnost. DAIKIN se zavazuje vyvinout veškeré úsilí, aby započal s odstraňováním vady zboží, za níž odpovídá, v co nejkratším termínu. Při dalším používání vadného zboží se záruka a/nebo odpovědnost DAIKINu vztahuje pouze na původní vadu. Náklady na odstranění vad zboží, provedené bez písemného předchozího souhlasu DAIKIN třetí osobou, se nenahrazují. Odpovědnost za následky takových odstraňování vad je ze strany DAIKINu vyloučena. 7. Záruční doba pro náhradní díly činí 6 měsíců od dodání. 8. Při odstranění vady nezačíná běžet záruční doba pro vyměněné nebo opravené díly znovu. 9. V případě, že je zákazník v prodlení s úhradou ceny zboží, není DAIKIN povinen odstranit zákazníkem uplatněné vady zboží, za něž DAIKIN odpovídá, a to až do okamžiku, dokud zákazník nesplní své platební závazky vůči DAIKINu. Zákazník není oprávněn, ani při oprávněných reklamacích, z tohoto důvodu pozastavit platbu ceny zboží či jiné splatné platby vůči DAIKINu. 10. Při dodání a montáži cizích výrobků se záruka omezuje na postoupení nároků na záruční plnění, které má DAIKIN vůči dodavatelům cizího výrobku. Další nároky zákazníka na záruční plnění, zejména na snížení ceny, jsou vyloučeny. 11. V případě vyřešení uplatněné reklamace (ať již z titulu vad zboží při předání či z titulu vad zboží, za něž DAIKIN odpovídá ze záruky) výměnou zboží či jeho části vyměněné zboží či jeho část přechází do vlastnictví DAIKIN, a to na základě výlučného uvážení a rozhodnutí DAIKINu. 12. Jakékoliv reklamace či nároky z titulu vad krytých zárukou je zákazník povinen uplatnit u DAIKINu písemně. B. Na náhradu újmy se uplatní obecné právní předpisy s tím, že právo zákazníka na náhradu újmy, resp. výše náhrady újmy ze strany DAIKINu se omezuje maximální částkou rovnající se kupní ceně zboží, s jehož dodáním DAIKINem zákazníkovi předmětná újma souvisí (v důsledku jehož dodání DAIKINem zákazníkovi újma vznikla). Omezení uvedené v předchozí větě se nevztahuje na právo zákazníka na náhradu újmy způsobené DAIKINem v případech uvedených v ustanovení § 2898 občanského zákoníku. II. NABÍDKA 1. Není- li v nabídce DAIKIN výslovně uvedeno jinak, nabídky DAIKIN jsou otevřené, orientační a nezávazné. Není-li v nabídce DAIKIN výslovně uvedeno jinak, údaje o mírách, hmotnostech, technických datech, množství a dodacích lhůtách jsou pouze orientační. 2. Ústní a telefonické dohody a ujednání musí být DAIKINem a zákazníkem písemně (dopisem, faxem nebo e-mailem) potvrzeny. III. OBJEDNÁVKY 1. Zákazník je povinen objednávat u DAIKINu zboží písemně (dopisem, faxem nebo e-mailem). 2. Ústní a telefonické dohody a ujednání musí být DAIKINem a zákazníkem písemně (dopisem, faxem nebo e-mailem) potvrzeny. IV. ZMĚNA PŘEDMĚTU PLNĚNÍ 1. Zrušení celé DAIKINem již akceptované objednávky nebo její části zákazníkem, příp. změna DAIKINem již akceptované objednávky zákazníkem jsou přípustné pouze s předchozím písemným souhlasem DAIKINu. V případě zrušení celé DAIKINem již akceptované objednávky nebo její části zákazníkem, příp. při změně DAIKINem již akceptované objednávky zákazníkem je DAIKIN vedle již poskytnutých plnění a vzniklých nákladů oprávněn účtovat zákazníkovi stornopoplatek ve výši 20% sjednané kupní ceny (ceny díla) zakázky včetně DPH, nejméně však 7 000 Kč. Pro specifické produktové skupiny zboží (např. „multiple scroll and screw chiller“) se aplikují zvláštní podmínky na zrušení DAIKINem již akceptované objednávky nebo její části zákazníkem, příp. změnu DAIKINem již akceptované objednávky zákazníkem, které jsou dostupné na www.daikin.cz, (v sekci „VOP“). 2. Pravidla uvedená v čl. IV odst. 1 těchto Všeobecných obchodních podmínek se plně uplatní i na případy, kdy smlouva na dodávku zboží byla mezi DAIKINem a zákazníkem uzavřena na základě nabídky DAIKINu ve smyslu čl. I odst. 4 písm. i a čl. II těchto Všeobecných obchodních podmínek. 3. V případě, že bude proti zákazníkovi zahájeno insolvenční řízení a/nebo zákazník vstoupí do likvidace, je DAIKIN oprávněn od smlouvy odstoupit a/nebo pozastavit plnění veškerých svých závazků ze smlouvy, a to až do doby, než zákazník řádně splní veškeré své povinnosti ze smlouvy pro něj vyplývající, a to aniž by DAIKIN byl povinen nahradit zákazníkovi případně vzniklou újmu. V. CENY A PLATEBNÍ PODMÍNKY 1. Kupní cena zboží (cena díla) (dále jen „cena“) se sjednává ve výši: i. v případě, že je smlouva na dodávku zboží mezi DAIKINem a zákazníkem uzavírána na základě nabídky DAIKINu ve smyslu čl. I odst. 4 písm. i a čl. II těchto Všeobecných obchodních podmínek, ve výši uvedené v takové nabídce DAIKINu; ii. v případě, že je smlouva na dodávku zboží mezi DAIKINem a zákazníkem uzavírána na základě objednávky zákazníka ve smyslu čl. I odst. 4 písm. ii a čl. III těchto Všeobecných obchodních podmínek, dle ceníků a “Dohody o vzájemné spolupráci“ s DAIKINem platných ke dni objednání zboží zákazníkem. Ceníky DAIKIN se zpravidla aktualizují jednou ročně. Změny cen DAIKINem však zůstávají vyhrazeny i v průběhu roku. DAIKIN je tedy oprávněn jednostranně měnit ceníky zboží a zavazuje se seznámit kupujícího s platnými ceníky (dopisem, emailem, faxem či publikací nového ceníku na domovské internetové stránce DAIKINu www.daikin.cz). Zákazník cenu zboží dle nového ceníku akceptuje svou objednávkou učiněnou za platnosti a účinnosti nového ceníku, který byl DAIKINem zákazníkovi oznámen a/nebo zpřístupněn (tj. např. tím, že zákazník objedná u DAIKINu zboží poté, co bude nový platný ceník poslán zákazníkovi anebo publikován na domovské internetové stránce DAIKINu ve smyslu výše uvedeného). 2. Ceny se rozumí netto bez jakýchkoli daní, poplatků nebo odvodů v uvedené měně včetně balného, není-li uvedeno jinak, na předem ve smlouvě dohodnuté místo určení. DAIKIN nepřijímá zpět jakékoliv obaly a balicí materiál. 3. Není- li v konkrétní smlouvě výslovně sjednáno jinak, je zákazník povinen zaplatit DAIKINu cenu zboží na základě DAIKINem vystavené faktury. 4. DAIKIN si vyhrazuje právo na částečná vyúčtování. 5. K reklamacím faktur, doručeným DAIKINu později než 2 týdny po obdržení faktury, se nepřihlíží. Není-li uvedeno v konkrétním případě jinak, činí splatnost faktur 30 dní od data vystavení faktury, přičemž dnem platby je den připsání příslušné fakturované platby beze srážek na účet DAIKINu. V případě prodlení zákazníka s úhradou ceny je zákazník povinen uhradit DAIKINu smluvní pokutu ve výši 0,05% denně z dlužné částky za každý i započatý den prodlení. Tím není dotčeno právo DAIKINu na náhradu škody v plném rozsahu. Dále je DAIKIN v případě prodlení zákazníka oprávněn požadovat po zákazníkovi náhradu veškerých nákladů spojených s vymáháním pohledávky, zejména výlohy na upomínky a inkasní náklady a zákazník je povinen tyto na výzvu DAIKINu nejpozději do pěti (5) dnů v plné výši uhradit. 6. V případě sjednání splátek na úhradu ceny se DAIKIN a zákazník ve smyslu § 1931 občanského zákoníku dohodli, že nesplní-li zákazník některou splátku, má DAIKIN právo na vyrovnání celé pohledávky. Toto právo může DAIKIN uplatnit nejpozději do splatnosti nejblíže příští splátky. 7. DAIKIN je oprávněn podmínit expedici zboží platbou předem, a to v jakékoliv výši až do 100% ceny. 8. Zákazník není oprávněn bez předchozího písemného souhlasu DAIKIN zadržovat platby a/nebo jednostranně započítat jakékoliv své pohledávky za DAIKINem na cenu zboží či jakoukoliv jinou pohledávku DAIKINu za zákazníkem. X. VRÁCENÍ ZBOŽÍ 1. Zákazník je oprávněn zboží vrátit a/nebo vyměnit pouze na základě předchozího písemného souhlasu DAIKINu, přičemž i v případě, že se DAIKIN dle svého výlučného uvážení rozhodne vratku zboží akceptovat, akceptuje vrácení zboží pouze v min. hodnotě 2 500 Kč bez DPH a max. hodnotě 1 250 000 Kč bez DPH za předpokladu, že toto zboží není poškozeno, nebylo použito, je zabaleno v originálních obalech a je v takových podmínkách umožňujících jeho další prodej. Zejména vrácení již nainstalovaného zboží (včetně chillerů) a speciálně vyrobených produktů (zboží) včetně náhradních dílů nebude v žádném případě ze strany ze strany DAIKINu akceptováno. 2. V případě, že si zákazník přeje vznést návrh na vrácení a/nebo výměnu zboží ve smyslu čl. X odst. 1 těchto Všeobecných obchodních podmínek, je povinen vyplnit formulář „Požadavek na vrácení zboží“, dostupný na www.daikin.cz a doručit jej (faxem nebo mailem) do DAIKINu na jím určenou adresu nejpozději do 10 dnů od dodání zboží. 3. Zákazník je v případě, že DAIKIN souhlasil s vrácením a/nebo výměnou zboží ve smyslu čl. X odst. 1 těchto Všeobecných obchodních podmínek, povinen doručit zboží na své nebezpečí a náklady do místa určeného DAIKINem. 4. V každém případě vrácení a/nebo výměny zboží bude zákazníkovi dobropisováno maximálně 80% ceny bez DPH, za níž DAIKIN toto zboží prodal zákazníkovi. Všechny standardní vratky budou předmětem poplatků za přeskladnění / administrativních poplatků ve výši 20% z ceny dotčeného zboží bez DPH. 5. Všechny vratky zboží DAIKIN prověří. Jestliže zboží není vráceno v souladu s těmito Všeobecnými obchodními podmínkami (viz. čl. X odst. 1 - 4 těchto Všeobecných obchodních podmínek), je DAIKIN oprávněn bez dalšího odmítnout vratku zboží a vrátit zboží zpět zákazníkovi na náklady a nebezpečí zákazníka. Alternativně k uvedenému v předchozí větě je DAIKIN oprávněn účtovat zákazníkovi vyšší náklady na přeskladnění zboží / admininstrativní poplatky než je 20% z ceny dotčeného zboží bez DPH uvedených v čl. X odst. 4 těchto Všeobecných obchodních podmínek. 6. Jakýkoliv DAIKINem vystavený dobropis, resp. pohledávka zákazníka za DAIKINem z takto vystaveného dobropisu, bude vždy započtena oproti pohledávkám DAIKINu za zákazníkem, které vzniknou z budoucích dodávek zboží DAIKINem zákazníkovi, a tedy žádná jiná forma úhrady pohledávky zákazníka za DAIKINem z vystaveného dobropisu není přípustná, nestanoví-li DAIKIN v konkrétním případě jinak. VI. DODACÍ LHŮTA 1. Není-li výslovně uvedeno jinak, dodací lhůty uvedené v nabídce jsou pouze orientační a nezávazné, DAIKIN však usiluje o dodržení uvedených lhůt. Prodlení s dodáním zboží oproti nabídce proto nemají za následek např. nároky na náhradu škody, resp. újmy, ani neopravňují k odstoupení smlouvy. Totéž platí, jestliže dodací lhůty nebyly dodrženy v důsledku vyšší moci, stávky nebo jiných událostí, které DAIKIN nemůže ovlivnit. 2. Požadavky zákazníka na smluvní pokuty či jiné penále jsou vyloučeny. 3. Dílčí dodávky DAIKINem zákazníkovi jsou přípustné. Při dílčí (částečné) dodávce nenáleží zákazníkovi náhrada nákladů částečnou dodávkou způsobených. 4. Je-li zákazník v prodlení s jakoukoliv splatnou platbou vůči DAIKINu, je DAIKIN oprávněn zadržet a pozastavit dodávky zboží zákazníkovi až do okamžiku úhrady všech splatných závazků zákazníka vůči DAIKINu, aniž by byl povinen nahradit zákazníkovi případně vzniklou újmu. V takovém případě není DAIKIN v prodlení s plněním svého závazku k dodání zboží. XI. SOUDNÍ PŘÍSLUŠNOST, ROZHODNÉ PRÁVO 1. Veškeré spory, které vzniknou mezi DAIKINem a zákazníkem budou řešeny obecným soudem s místní příslušností dle sídla DAIKIN. 2. Veškeré smluvní vztahy jakož i veškeré spory vzniklé v souvislosti s těmito smluvními vztahy se řídí českým právem s vyloučením jeho kolizních norem. Úmluva OSN o smlouvách o mezinárodní koupi zboží se nepoužije. 3. Práva a povinnosti DAIKINu a zákazníka, která nejsou výslovně upraveny příslušnou smlouvou či těmito Všeobecnými obchodními podmínkami, se řídí občanským zákoníkem a ostatními právními předpisy v mezích jejich působnosti. VII. PŘEVZETÍ DODÁVKY, PŘECHOD NEBEZPEČÍ ŠKODY NA ZBOŽÍ, PRODLENÍ S PŘEVZETÍM 1. Dodávky zboží se provádějí, není-li sjednáno něco jiného, podle dodací doložky CIP dle Incoterms 2010 na předem dohodnuté místo určení. 2. Dodávky zboží podle dodací doložky CIP dle čl. VII odst. 1 těchto Všeobecných obchodních podmínek pokrývají pouze minimální přepravní náklady. Zvláštní pojištění pro přepravu zboží se uzavírá pouze po zvláštní písemné dohodě a na náklady zákazníka. 3. Zákazník je povinen zkontrolovat bez zbytečného odkladu zboží, zda nedošlo ke škodám při přepravě a zapsat případná poškození obalu nebo zboží přímo do přepravního listu a DAIKINu tyto bez zbytečného odkladu, nejpozději však do následujícího pracovního dne, písemně oznámit. Případné škody vzniklé při přepravě, které nebyly zjevné při předání zboží, je zákazník povinen reklamovat u DAIKIN okamžitě, nejpozději však do 3 dnů po předání zboží zákazníkovi, v opačném případě nemá zákazník nárok na jakékoliv plnění ze strany DAIKIN. Není- li v konkrétním případě sjednáno DAIKINem se zákazníkem písemně jinak, pak v případě, že bude doprava (přeprava) zboží realizována na žádost zákazníka prostřednictvím dopravce zjednaného zákazníkem, podpis dodacího listu zboží přepravcem se pro účely převzetí zboží a splnění smlouvy ze strany DAIKIN považuje za podpis zákazníka. 4. Zákazník souhlasí, že v případě, že bude zboží DAIKINem přepravováno k zákazníkovi externím přepravcem zjednaným DAIKINem (zejména, ale nikoliv pouze, GEBRÜDER WEISS spol. s r.o.), bude se potvrzení přepravního listu tohoto přepravce ze strany zákazníka považovat za potvrzení převzetí zboží uvedeného na dodacím listu DAIKINu, na nějž přepravní list přepravce odkazuje, ze strany zákazníka, když tento dodací list DAIKINu doručí DAIKIN zákazníkovi vždy před dodáním zboží písemně a/nebo faxem a/nebo emailem. Číslo dodacího listu DAIKINu je uvedeno na přepravních listech přepravce GEBRÜDER WEISS spol. s r.o. 5. Dostane-li se zákazník do prodlení s převzetím zboží, je DAIKIN s výhradou ostatních práv oprávněn se zákazníkem objednaným zbožím nakládat dle vlastního uvážení (tj. např. prodat jej třetí osobě). V takovém případě počíná doručením písemného požadavku zákazníka na dodávku původně zákazníkem objednaného zboží běžet nová dodací lhůta v délce sjednané v původní smlouvě. 6. DAIKIN je v případě prodlení zákazníka s převzetím zboží rovněž oprávněn bez dalšího upozornění uskladnit zákazníkem objednané zboží ve svém skladu či na jiném místě na náklady zákazníka. XII. SALVÁTORSKÁ KLAUZULE 1. V případě neplatnosti nebo neúčinnosti jednotlivých ustanovení těchto Všeobecných obchodních podmínek nebo smlouvy, uzavřené mezi DAIKINem a zákazníkem, zůstává platnost a účinnost zbývajících ustanovení nedotčena. Neplatná či neúčinná ustanovení budou nahrazena takovými přípustnými ustanoveními, která jsou sjednané vůli stran nejblíže. XIII. OSTATNÍ 1. Zákazník je oprávněn postoupit jakékoliv pohledávky za DAIKINem na třetí osobu pouze s předchozím písemným souhlasem DAIKINu. 2. DAIKIN je oprávněn kdykoliv postoupit smlouvu na dodávku zboží se zákazníkem nebo všechna či pouze některá svá práva a povinnosti z této smlouvy na jiný subjekt, s čímž zákazník uzavřením předmětné smlouvy s DAIKINem souhlasí. 3. Informace poskytnuté DAIKINem zákazníkovi v souvislosti se smlouvou a objednávkami se považují za důvěrné. 4. Zákazník se zavazuje, že neporuší obchodní tajemství DAIKINu, o kterém se dozví v souvislosti s obchodním vztahem. Zároveň se zavazuje, že zajistí dodržování obchodního tajemství DAIKINu i obchodními partnery zákazníka. 5. Veškerá práva DAIKINu plynoucí z uzavřených smluv se promlčují v promlčecí lhůtě v trvání 10 let ode dne, kdy právo mohlo být uplatněno poprvé. 6. Zákazník na sebe ve smyslu ustanovení § 1765 odst. 2 občanského zákoníku přebírá nebezpečí změny okolností. 7. Tyto Všeobecné obchodní podmínky nabývají platnosti a účinnosti dnem 1. ledna 2014, ruší bez dalšího Všeobecné obchodní podmínky DAIKIN ze dne 1. 4. 2013, a jejich platnost a účinnost není časově omezená. DAIKIN AIRCONDITIONING CENTRAL EUROPE – CZECH REPUBLIC spol. s r.o. Obchodní podmínky společnosti Daikin jsou k dispozici také na internetu na webových stránkách www.daikin.cz. DAIKIN AIRCONDITIONING CENTRAL EUROPE - CZECH REPUBLIC SPOL. S R. O. Pobřežní 3, 186 00 Praha 8, Česká republika Tel.: +420 221 715 700, Fax: +420 221 715 701, Email: [email protected], Web: www.daikin.cz 35 EWAD-TZ New inverter and compressor technology The new inverter chiller features a screw compressor with in-built inverter and variable volume ratio. These new technologies result in a high seasonal efficiency and a rapid payback combined with an extensive option list and a compact design. Daikin Europe N.V. participates in the Eurovent Certification programme for Air conditioners (AC), Liquid Chilling Packages (LCP), Air handling units (AHU) and Fan coil units (FCU), Check ongoing validity of certificate online: www.eurovent-certification.com or using: www.certiflash.com Daikin Products are distributed by: DAIKIN AIRCONDITIONING CENTRAL EUROPE – CZECH REPUBLIC spol. s r.o. budova IBC – Pobřežní 3, CZ – 186 00 Praha 8 Tel.: +420 221 715 700, Fax: +420 221 715 701 e-mail: [email protected], www.daikin.cz DACE Applied Systems Pricelist 2014 • Copyright Daikin We reserve the right for printing errors and model changes. The present publication is drawn up by way of information only and does not constitute an offer binding upon Daikin Europe N.V./Daikin Central Europe HandelsGmbH. Daikin Europe N.V./Daikin Central Europe HandelsGmbH has compiled the content of this leaflet to the best of its knowledge. No express or implied warranty is given for the completeness, accuracy, reliability or fitness for particular purpose of its content and the products and services presented therein. Specifications are subject to change without prior notice. Daikin Europe N.V./Daikin Central Europe HandelsGmbH explicitly rejects any liability for any direct or indirect damage, in the broadest sense, arising from or related to the use and/or interpretation of this leaflet. All content is copyrighted by Daikin Europe N.V.
Podobné dokumenty
Aplikované systémy - Klimatizace Daikin
interiérových podlah, nízkoemisní tmely a místní nákup materiálů.
Katalog + ceník Aplikované systémy 2016
a užívat si trvale udržitelný úspěch spolu s pokračujícím růstem.
Stavové rovnice v teorii regulace
popsán stacionárními operátory. Jinými slovy, systém popsaný diferenciálními
rovnicemi s konstantními koeficienty je stacionární a podobně systém vyjádřený
rovnicemi (2.19) a (2.20) je stacionární,...
Split/Sky Air - Klima Chlazení
Multi-Split aplikace - komfort pro celý dům z jedné venkovní jednotky
Tato jednota může být připojena k multi-splitové venkovní jednotce. Multi-splitové aplikace umožňují chladit několik
místností ...
Aplikované systémy - Klimatizace Daikin
Parapetní / BLDC
FWZ-A
2,6 - 10 kW
Flexibilní / BLDC
FWR-A
2,6 - 10 kW
Flexibilní zabudovaná / BLDC
FWS-A
2,6 - 10 kW
Vzduchotechnické jednotky – AHU
D-AHU Modular
1200-15000 m3...
Ceník - Klimatizace Daikin
YCQ140DGF obsahuje jemý filtr pro použítí v prostředích s jemným prachem jako například obchody s oblečením. Není vhodný
pro prostory s vysokou vlhkostí nebo mastnotou.
Bílý (RAL9010) dekorační p...