yokogawa - MARING, spol s ro
Transkript
General Specifications Model RAKD Small Metal Rotameter® A float is guided concentrically in a special shaped conic metal tube. The position of this float is magnetically transmitted to the indicator. The short-tube Rotameter is used for measurement of low flow rates of liquids and gases. Its special application is in troubled, opaque or aggressive mediums and under high pressure. The instrument is mounted in a vertical pipeline with flow direction upwards. FEATURES Different process connections like internal threads and flanges ● With valves (horizontal connection) and without valve (vertical connection) ● Version with controller (only in combination with valve) ● All wetted parts of stainless steel (1.4571) ● Accuracy class 4 (according VDI/VDE 3513) ● Round industrial standardized stainless steel housing of protection IP 65 (on request IP67) ● Light, guided floats resulting in low pressure loss and stable float movement ● Maximum flow range 1-250l/h water resp. 45-8000l/h air, portioned in 13 flow ranges with a relation of 1:10 ● Graduation of maximum flow ranges by factor 1,6 realised with 4 floats and 13 cone sizes ● Fine controll valve with PTFE-gasket ● Electric µP-controlled transmitter with linearized output also in Ex-version (in preparation) ● Electrical connection by fast connection technique (Quickon) ● Inductive sensors as limit switches also in Fail-Safe-version can be fit ● Pressure controller (normal up to 25 bar at 20°C) for a maximum flow of 100l/h water resp. 3.250l/h air ● Connection of common transformer isolated barriers and transmitter power supplies possible ● Alignment possibility of the electric transmitters with additional tuner ● Fig 1.a Indicator RAKD Fig 1.b Tube RAKD YOKOGAWA GS 1R1B30-E-H 1st. edition 2 STANDARD SPECIFICATION The responsiblity with respect to the suitability and according application of our flowmeter is only situated by the customer. Fluid to be measured Measurable flow rates Measuring range Accuracy Indicator scale Process temperature - of local indicator - without valve - with valve - with limit switches – for electronic transmitter Process connection - Internal thread - Cutting ring - Nozzle - Flanges Material Housing - Material - Installation position - Flowdirection - Installation length - Protection Weight : : : : Type : intrinsically safe power supply unit with galvanic isolation of in- and output (SINEAX B811) 24V to 60V AC/DC or 85V to 230V AC : 750 W : 0/4 - 20mA : intrinsically safe [EEx ia] IIC Liquid or gas Refer to “Flow table” 10:1 Class 4 acc. to VDI/VDE 3513; for smallest range (cone 31 + 32), 5% of endscal value : Flow units or percent Power supply : -80 °C to +200 °C (60 °C TU) standard (higher temperature on demand) : -80 °C to +150 °C (60 °C TU) TECHNICAL SPECIFICATION OF THE OPTIONS : - 40 °C to +150 °C : - 40 °C bis +150 °C Ambient temperature Nominal voltage Output signal : G 1/4; NPT 1/4; G 3/8; NPT 3/8 : 6 mm; 8 mm; 10 mm; 12 mm : 6 mm; 8 mm : DN15 PN40;DN25 PN40; ANSI 1/2 150lbs, 300lbs ANSI 1 150lbs, 300lbs : Wetted parts of 1.4571 Other materials on request : : : : : : CrNi-Steel (1.4301) Vertical Upwards 125 mm (250 mm with flanges) IP 65 (IP67 on request) refer to ‘table weight’ page 11 ELECTRIC TRANSMITTER Power supply : 13,5-30 V DC - Load resistance : (U-13,5V) /20mA Output signal : 4-20 mA Ambient temperarature : -25 °C to + 70 °C Storage temperature : -40 °C to +70 °C Linerarity : ≤ ± 0,2% full scale Hysteresis : ≤ ± 0.1% full scale Repeatability : ≤ ± 0,1 % full scale Influence of power supply : ≤ ± 0,1 % full scale Temperature coefficient of output signal : ≤ ± 0,5% /10 K full scale AC portion of output signal : ≤ ± 0,15% full scale Long-time stability : ≤ ± 0,2 % / year Max. output signal : 21,5 mA Output signal in failure : ≤ 3,6mA (NAMUR NE 43) Response time (99%) : ca. 1,5 s Explosion proof : EEx ia IIC (in preparation) Electrical connection : QUICKON - Cable diameter : 4-6 mm - Max. conductor : 0,34 ÷ 0,75 mm2 GS 1R1B30-E-H POWER SUPPLY FOR ELECTRIC TRANSMITTER Max. load resistance Output signal Control circuit Entity parameters : acc. certificate of conformity PTB Nr. Ex-96.D.2043 Type : Inductive switch SC2-NO acc. EN 50227 (NAMUR) : -25°C to +70° C : 8 V DC : ≤ 1 mA = operated; ∆ 3 mA = not operated : EEx ia IIC T1 - T6 Explosion proof Entity parameters : acc. certificate of conformity PTB-Nr. Ex-95.D.2195x LIMIT SWITCH IN FAIL SAFE VERSION Type Ambient temperature Nominal voltage Output signal : Inductive switch SJ 2 -S1N acc. EN 50227 (NAMUR) in : -25°C to +100° C : 8 V DC : ≤ 1 mA not operated : ≤ 1 mA safety state : ≤ 3 mA operated; Other specifications : Technical data on request 3 Control characteristics POWER SUPPLY FOR LIMIT SWITCHES Type : Transformer isolated barrier acc. EN 50227 (NAMUR) : 230 V AC + 10%/-15%, 50/60 Hz or 24 V DC ± 20% : 1 potential-free changeover : 2 potential-free changeover : Max. 250 V AC; max. 2A : Intrinsically safe [EEx ia] IIC Power supply Relay output : See diagram The curves V1 to V6 indicate how the flow depends on the inlet pressure for different valve settings. The back pressure at the outlet (ambient pressure) is 1 bar. l/h air at 20°C; 1.013 bar abs. Switching capacity Control circuit Entity parameters : acc. certificate of conformity PTB Nr.Ex-94.C2086 CONTROLLER Differential pressure controller for a constant flow at fluctuations of the process pressure. These are no valves to reduce the pressure. -Controller /R1 and /R2 for liquids with variable inlet or outlet pressure and for gases with variable inlet pressure and constant back pressure. - Controller /R3 and /R4 for gases with fluctuations of the back pressure. Max. liquid flow : 100 l/h Max. gas flow : 3250 l/h Max. pressure : 25 bar Recommended differential pressure : > 400 mbar Materials Housing Diaphragm Springs R1/R3 CrNi-steel PTFE CrNi-steel R2/R4 Brass Buna CrNi-steel Inlet pressure Fig 2. Diagram control characteristics RAKD-E80 Power supply U= 13.5V - 30V + Output - 4-20 mA - RL < U - 13.5 V 20 mA T=Connector QUICKON Fig 3. RAKD with electric transmitter GS 1R1B30-E-H 4 RAKD - E80 Power supply U= 13.5V - 30V DC + + Output - 4-20 mA - RL < Limit switch EN 50227 (Namur) U - 13.5 V 20 mA Supply 230 V AC Limit T, S =Connector QUICKON Transmitter relay KF A6-SR2-Ex2W Fig 4. RAKD with electric transmitter and one limit switch with transformer isolated barrier Hazardhous Area Safe Area Supply 230 V AC RAKD - T80 Limit max. Limit min Limit switch EN 50227 (Namur) Transmitter relay KF A6-SR2-Ex2W T, S =Connector QUICKON Fig 5. RAKD only with local indication and two limit switches with transformer isolated barrier GS 1R1B30-E-H 5 MODEL SPECIFICATIONS Fixing model code following possibilities are available: Please make your decision in this order 1. Option / Controller 2. Version with/without valve 3. Flow ranges Cone with controller with valve RAKD01 - 56 without controller without controller with valve without valve 1.0 - 100 l/h water 1.0-250 l/h water 1.0 - 100 l/h water 160-250 l/h water 45 - 3300 3250 l/h air 45 - 3250 3300 l/h air 45-8000 l/h air 31-51 4. Process connection without valve without controller 31-53 31-51 5500-8000 l/h air 5000 52, 53 Intern. Thread Flange Flange Flange Cutting ring Cutting ring Innengewinde Cutting ring Nozzle Nozzle Cutting ring - - page 6 page 7 Nozzle - and specify the model code acccording the pages page 8 page 9 Ordering instructions Standard: a: Model, suffix and option code b: Flow conditions c: Temperature d: Pressure e: Viscosity f: Density For gases: cross reference of the scale Option /B: customer specification notes for dimensioning conversion tofor Please use the sizing program DUREP_V 2.7ab (or higher versions) for other media/process conditions. GS 1R1B30-E-H GS 1R1B30-E-H 53 54 55 56 53 54 Cutting ring: ∅ 6 PN 25 ∅ 8 PN 25 ∅ 10 PN 25 ∅ 12 PN 25 Nozzle: ∅ 6 PN 10 ∅ 8 PN 10 P1 P1 C3 C3 C3 C3 R3 T3 KD SS Cone 31-37 41-43 44-51 Water (l/h) 1 1.6 2.5 4.0 6.0 10 16 25 40 60 100 Max. Flow 31 32 33 34 37 41 42 43 44 47 51 Cone ∆p mbar 6 8 11 Air (l/h) 40 60 100 150 200 325 500 800 1400 2000 3250 SS Valve seat Silver PCTFE Gasket PTFE PTFE Valve seat Silber PCTFE With valve in outlet Gasket PTFE PTFE With valve in inlet Version For calculation to other fluids / process conditions please use our sizing program Durep_V2.7b or a higher edition. 41 41 A Internal thread: Rp 1/4 PN 25 1/4 NPT PN 25 Process connection R Material: 1.4571 VSA VPA VSE VPE 80 RAKD with valve and controller 1.0 – 100 l/h water / 40 – 3250 l/h air: Style: Version Power supply: none, for local indicator „T“ for electric type „E“, 24V DC, 2-wire, 4-20mA Housing type: Stainless steel Type: Local indicator Indicator with electric output Indicator * D D 424 NNN 80 T E / Transmitter power supply, SINAX B811-14, 230V/115V AC with galvanic isolation, output 0/4-20mA for Ex-version Transmitter power supply, SINAX B811-13, 24V AC/DC with galvanic isolation, output 0/4-20mA for Ex-version Transformer isolated barriers KFA6-SR2-Ex1.W/230 V AC; 1-channel, 1 changeover contact Transformer isolated barriers KFA6-SR2-Ex2.W/230 V AC; 2-channels, 2 changeover contact Transformer isolated barriers KFD2-SR2-Ex1.W/24 V DC; 1-channel, 1 changeover contact Transformer isolated barriers KFD2-SR2-Ex2.W/24 V DC; 2-channels, 2 changeover contact Additional instruments Pre pressure controller 1.4571 (only with valve in inlet; for gas with variable pre pressure and liquids with variable pre and back pressure) Pre pressure controller brass (only with valve in inlet; for gas with variable pre pressure and liquids with variable pre and back pressure) Back pressure controller 1.4571 (only with valve in outlet; for gas with variable back pressure) Back pressure controller brass (only with valve in outlet; for gas with variable back pressure) Regler: Certificates Pressure test with certificate Certificate of compliance 2.1 acc. EN 10204 Test report 2.2 acc. EN 10204 3.1B Certificate acc. EN 10204 only for tube, connection heads, screw sealing plug Intrinsically safe: CENELEC ATEX (only for electricl output and contact) (only local indicator type: T) Fail-Safe version Fail-Safe version Fail-Safe version (only local indicator type: T) /H1 Limit switches: Min - Contact Max - Contact Min - Max - Contact Min - Contact Max – Contact Min - Max – Contact /W4B /W4A /W2B /W2A /U3F /U2F /R4 /R3 /R2 /R1 /PP /P2 /P3 /P6 /XE /K1 /K2 /K3 /K6 /K7 /K8 /BG /BD /B1 Test: Certificate oil and grease free for oxygene use Options Mark: V4A-stainless steel plate (description according customer demand) Tag – No. on scale, or other Rotameter – Specification (max. 2x40 signs) Double scale 6 MODEL SPECIFICATIONS 53 53 54 54 55 55 56 56 53 54 Cutting ring: ∅ 6 PN 40 ∅ 6 PN 100 ∅ 8 PN 40 ∅ 8 PN 100 ∅ 10 PN 40 ∅ 10 PN 100 ∅ 12 PN 40 ∅ 12 PN 100 Nozzle: ∅ 6 PN 10 ∅ 8 PN 10 P1 P1 C4 C6 C4 C6 C4 C6 C4 C6 G4 G6 T4 T6 KD SS Konus 31-37 41-43 44-51 52-53 Water (l/h) 1 1.6 2.5 4.0 6.0 10 16 25 40 60 100 160 250 Max. Flow 31 32 33 34 37 41 42 43 44 47 51 52 53 Cone ∆p mbar 6 8 11 13 Air (l/h) 40 60 100 150 200 325 500 800 1400 2000 3250 5000 8000 SS Silver PCTFE Valve seat Gasket PTFE PTFE Valve seat Silver PCTFE With valve in output Gasket PTFE PTFE With valve in input Version For calculation to other fluids / process conditions please use our sizing program Durep_V2.7b or a higher edition. 41 41 41 41 A Internal thread: G 1/4 PN 40 G 1/4 PN 100 1/4 NPT PN 40 1/4 NPT PN 100 Process connection R Materila: 1.4571 RAKD with valve 1.0 – 250 l/h water / 40 – 8000 l/h air: VSA VPA VSE VPE 80 Style: Version Power supply: none, for local indicator „T“ for electric type „E“, 24V DC, 2-wire, 4-20mA Housing type: Stainless steel Type: Local indicator Indicator with electric output Indicator * 80 T E D 424 NNN D / (only local indicator type: T) Fail-Safe version Fail-Safe version Fail-Safe version (only local indicator type: T) Transmitter power supply, SINAX B811-14, 230V/115V AC with galvanic isolation, output 0/4-20mA for Ex-version Transmitter power supply, SINAX B811-13, 24V AC/DC with galvanic isolation, output 0/4-20mA for Ex-version Transformer isolated barriers KFA6-SR2-Ex1.W/230 V AC; 1-channel, 1 changeover contact Transformer isolated barriers KFA6-SR2-Ex2.W/230 V AC; 2-channels, 2 changeover contact Transformer isolated barriers KFD2-SR2-Ex1.W/24 V DC; 1-channel, 1 changeover contact Transformer isolated barriers KFD2-SR2-Ex2.W/24 V DC; 2-channels, 2 changeover contact Additional instruments Certificates Pressure test with certificate Certificate of compliance with 2.1acc. EN 10204 Test report 2.2 acc. EN 10204 Inspection certificate 3.1B acc. EN 10204 only for tube, connection heads, screw sealing plug Intrinsically safe: CENELEC ATEX (only for electric output and contact) Limit switches: Min - Contact Max - Contact Min - Max - Contact Min - Contact Max - Contact Min - Max - Contact Test: Certificate oil and grease free for oxygene use Mark: V4A-stainless steel plate (description according customer demand) Tag – No. on scale, or other Rotameter – Specification (max. 2x40 signs) Double scale Options /W4B /W4A /W2B /W2A /U3F /U2F /PP /P2 /P3 /P6 /XE /K1 /K2 /K3 /K6 /K7 /K8 /H1 /BD /BG /B1 7 MODEL SPECIFICATIONS GS 1R1B30-E-H GS 1R1B30-E-H 41 41 41 41 53 53 54 54 55 55 56 56 53 54 Internal thread: G 1/4 PN 100 G 1/4 PN 160 1/4 NPT PN 100 1/4 NPT PN 160 Cutting ring: ∅ 6 PN 100 ∅ 6 PN 160 ∅ 8 PN 100 ∅ 8 PN 160 ∅ 10 PN 100 ∅ 10 PN 160 ∅ 12 PN 100 ∅ 12 PN 160 Nozzle: ∅ 6 PN 10 ∅ 8 PN 10 P1 P1 C6 C7 C6 C7 C6 C7 C6 C7 G6 G7 T6 T7 D4 D4 A1 A1 A2 A2 KD SS Cone 31-37 41-43 44-51 Water (l/h) 1 1.6 2.5 4.0 6.0 10 16 25 40 60 100 Max. Flow 31 32 33 34 37 41 42 43 44 47 51 Cone ∆p mbar 6 8 11 Air (l/h) 40 60 100 150 200 325 500 800 1400 2000 3250 SS NNN Without valve Version For calculation to other fluids / process conditions please use our sizing program Durep_V2.7b or a higher edition. 01 02 01 02 01 02 A Flange: DN 15 PN 40 DN 25 PN 40 ANSI 1/2 150 lbs ANSI 1 150 lbs ANSI 1/2 300 lbs ANSI 1 300 lbs Process connection R Material: 1.4571 RAKD without valve 1.0 – 100 l/h water / 40 – 3250 l/h air: NNN 80 Style: Version Power supply: none, for local indicator „T“ for electric type „E“, 24V DC, 2-wire, 4-20mA Housing type: Stainless steel Type: Local indicator Indicator with electric output Indicator * 80 T E D 424 NNN D / /H1 /K1 /K2 /K3 /K6 /K7 /K8 Limit switches: Min - Contact Max - Contact Min - Max - Contact Min - Contact Max - Contact Min - Max - Contact Transmitter power supply, SINAX B811-14, 230V/115V AC with galvanic isolation, output 0/4-20mA for Ex-version Transmitter power supply, SINAX B811-13, 24V AC/DC with galvanic isolation, output 0/4-20mA for Ex-version Transformer isolated barriers KFA6-SR2-Ex1.W/230 V AC; 1-channel, 1 changeover contact Transformer isolated barriers KFA6-SR2-Ex2.W/230 V AC; 2-channels, 2 changeover contact Transformer isolated barriers KFD2-SR2-Ex1.W/24 V DC; 1-channel, 1 changeover contact Transformer isolated barriers KFD2-SR2-Ex2.W/24 V DC; 2-channels, 2 changeover contact /W4B /W4A /W2B /W2A /U3F /U2F /PP /P2 /P3 /P6 Certificates Pressure test with certificate Certificate of compliance with 2.1acc. EN 10204 Test report 2.2 acc. EN 10204 Inspection certificate 3.1B acc. EN 10204 only for tube, connection heads, screw sealing plug Additional instruments /XE Intrinsically safe: CENELEC ATEX (only for electric output and contact) (only local indicator type: T) Fail-Safe version Fail-Safe version Fail-Safe version (only local indicator type: T) /BD Test: Certificate oil and grease free for oxygene use /B1 /BG Mark: V4A-stainless steel plate (description according customer demand) Tag – No. on scale, or other Rotameter – Specification (max. 2x40 signs) Double scale Options 8 MODEL SPECIFICATIONS 42 42 42 42 53 53 54 54 55 55 56 56 Internal thread: G 3/8 PN 100 G 3/8 PN 160 3/8 NPT PN 100 3/8 NPT PN 160 Cutting ring: ∅ 6 PN 100 ∅ 6 PN 160 ∅ 8 PN 100 ∅ 8 PN 160 ∅ 10 PN 100 ∅ 10 PN 160 ∅ 12 PN 100 ∅ 12 PN 160 C6 C7 C6 C7 C6 C7 C6 C7 G6 G7 T6 T7 D4 D4 A1 A1 A2 A2 KD SS Cone 52-53 Water (l/h) 160 250 Max. Flow 52 53 Cone ∆p mbar 13 Air (l/h) 5000 8000 SS NNN Without valve Version For calculation to other fluids / process conditions please use our sizing program Durep_V2.7b or a higher edition. 01 02 01 02 01 02 A Flange: DN 15 PN 40 DN 25 PN 40 ANSI 1/2 150 lbs ANSI 1 150 lbs ANSI 1/2 300 lbs ANSI 1 300 lbs Process connection R Material: 1.4571 RAKD without valve 160 – 250 l/h water / 5000 – 8000 l/h air: NNN 80 Style: Version Power supply: none, for local indicator „T“ for electric type „E“, 24V DC, 2-wire, 4-20mA Housing type: Stainless steel Type: Local indicator Indicator with electric output Indicator * 80 T E / D 424 NNN D Options /K1 /K2 /K3 /K6 /K7 /K8 Transmitter power supply, SINAX B811-14, 230V/115V AC with galvanic isolation, output 0/4-20mA for Ex-version Transmitter power supply, SINAX B811-13, 24V AC/DC with galvanic isolation, output 0/4-20mA for Ex-version Transformer isolated barriers KFA6-SR2-Ex1.W/230 V AC; 1-channel, 1 changeover contact Transformer isolated barriers KFA6-SR2-Ex2.W/230 V AC; 2-channels, 2 changeover contact Transformer isolated barriers KFD2-SR2-Ex1.W/24 V DC; 1-channel, 1 changeover contact Transformer isolated barriers KFD2-SR2-Ex2.W/24 V DC; 2-channels, 2 changeover contact /W4B /W4A /W2B /W2A /U3F /U2F /PP /P2 /P3 /P6 Certificates Pressure test with certificate Certificate of compliance with 2.1acc. EN 10204 Test report 2.2 acc. EN 10204 Inspection certificate 3.1B acc. EN 10204 only for tube, connection heads, screw sealing plug Additional instruments /XE Intrinsically safe: CENELEC ATEX (only for electric output and contact) (only local indicator type: T) Fail-Safe version Fail-Safe version Fail-Safe version (only local indicator type: T) /H1 Limit switches: Min - Contact Max - Contact Min - Max - Contact Min - Contact Max - Contact Min - Max - Contact /BD /BG /B1 Test: Certificate oil and grease free for oxygene use Mark: V4A-stainless steel plate (description according customer demand) Tag – No. on scale, or other Rotameter – Specification (max. 2x40 signs) Double scale 9 MODEL SPECIFICATIONS GS 1R1B30-E-H 10 DIMENSIONS ø 101 Flange DN15 PN40 Flange DN25 PN40 Flange ANSI 1/2” 150 lbs Flange ANSI 1” 150 lbs Flange ANSI 1/2” 300 lbs Flange ANSI 1” 300 lbs ca 250 125 Ca 185 ø 101 Cutting ring Fig 7. Version with flange Fig 6. Version (without valve) 28 50 125 155,5 ø 101 Cutting ring ca 62 Fig 8. Version with inlet valve GS 1R1B30-E-H 60 11 163 125 DIMENSIONS AND WEIGHT Cutting ring Rp Screwing ca 113 60 NPT Screwing ca 136 Ca 142 Fig 9. Version with inlet valve and inlet controller Ca 142 NPT Screwing ca 136 60 125 163 Rp Screwing ca 113 Cutting ring Fig 10. Version with outlet valve and back pressure controller Dimensions and weight Weight Flowrange Dimension “a” Dimension “b” Dimension “c” without valve with valve with controller to 100 l/h water 160 + 250 l/h water G1/4 or 1/4 NPT G3/8 or 3/8 NPT G1/4 or 1/4 NPT Rp1/4 or 1/4 NPT ca. 600 g ca.1000 g --- ca. 1800 g --- GS 1R1B30-D-H 28 125 155,5 a ø 101 60 Cutting ring 50 Ca 62 Fig 11. Version with outlet valve 50 10 30 62 125 ø 101 Additional bore for fixing. For the bore please use no ferritic (magnetic) materials! Fig 12. Version back front with fixing YOKOGAWA EUROPEAN HEADQUARTERS Yokogawa Europe B.V. Vanadiumweg 11, 3812 PX AMERSFOORT The Netherlands Tel. +31-33-4641 611 Fax +31-33-4641 610 E-mail: [email protected] www.yokogawa-europe.com THE NETHERLANDS Yokogawa Nederland B.V. Hoofdveste 11 3992 DH HOUTEN Tel. +31-30-635 77 77 Fax +31-30-635 77 70 AUSTRIA Yokogawa Austria Ges.m.b.H. Franzensbrückenstrasse 26 A-1021 WIEN Tel. +43-1-2165 043 0 Fax +43-1-2165 043 33 GS 1R1B30-E-H BELGIUM Yokogawa Belgium N.V./S.A. Minervastraat 16 1930 ZAVENTEM Tel. +32-2-719 55 11 Fax +32-2-725 34 99 FRANCE Yokogawa Contrôle Bailey S.A. Vélizy Valley 18-20 Rue Grange Dame Rose 78140 VELIZY VILLACOUBLAY Tel. +33-1-39 26 10 00 Fax +33-1-39 26 10 30 GERMANY Yokogawa Deutschland GmbH Berliner Strasse 101-103 D-40880 RATINGEN Tel. +49-2102-4983 0 Fax +49-2102-4983 22 Suject to change without notice Copyright© HUNGARY Yokogawa Hungaria Ltd. Alkotas Center 39 C 1123BP BUDAPEST Tel. +36-1-355 39 38 Fax +36-1-355 38 97 ITALY Yokogawa Italia S.r.l. Vicolo D. Pantaleoni, 4 20161 MILANO Tel. +39-02-66 24 11 Fax +39-02-645 57 02 SPAIN Yokogawa España S.A. C/Francisco Remiro, N°2, Edif. H 28028 MADRID Tel. +34-91-724 20 80 Fax +34-91-355 31 40 UNITED KINGDOM Yokogawa United Kingdom Ltd. Stuart Road, Manor Park, RUNCORN Cheshire WA7 1TR Tel. +44-1-928 597100 Fax +44-1-928 597101 AUSTRALIA Yokogawa Australia Pty Ltd. Private mail bag 24 Centre Court D3 25-27 Paul Street North NORTH RYDE, N.S.W. 2113 Tel. +61-2-805 0699 Fax +61-2-888 1844 SINGAPORE 5 Bedok South Road SINGAPORE 469270 Tel. +65-241 99 33 Fax +65-444 62 52 Manufactured by: GERMANY Rota Yokogawa GmbH & Co. KG Rheinstrasse 8 D-79664 WEHR Tel. +49-7761-567 0 Fax +49-7761-567 126 SOUTH AFRICA Yokogawa South Africa (Pty) ltd. 67 Port Road, Robertsham Southdale 2135, JOHANNESBURG Tel. +27-11-680-5420 Fax +27-11-680-2922 UNITED STATES OF AMERICA Yokogawa Corporation of America 2 Dart Road NEWNAN, GA 30265-1040 Tel. +1-770-253 70 00 Fax +1-770-251 20 88 ISO 9001 CERTIFICATED FIRM CENTRAL/EAST REGION Via Yokogawa Austria: Czechia, Slovakia, Poland, Croatia, Slovenia, Jugoslavia, Bulgaria, Romania, Macedonia, Bosnia & Herzegovina Distributors in: Denmark, Finland, Greece, Norway, Portugal, Sweden, Switzerland and Turkey. Block 03, 07-99 Printed in the Netherlands, 01-004 (A) Q
Podobné dokumenty
SC42 a FF40/FS40/FD40
uživateli nejlepší řešení pro jakýkoli proces
s ohledem na chemickou odolnost, tlakové a
teplotní specifikace.
VLASTNOSTI
Obsah 2 - Trival
ROZMĚRY ZÁVITŮ – MODEL I1 – DVOJPŘÍRUBA ISO 5752 SÉRIE 13 DN 80/3” – DN 1000/40” ANSI 150/300/600 lbs
THREAD DIMENSIONS – MODEL I1 – DOUBLE FLANGE ISO 5752 SERIES 13 DN 80/3” – DN 1000/40” ANSI 150...
Řídící jednotka GECO ke Kompaktu 300 - ECOSOL
- S1-S2 – NC (normálně sevřen),
- S2-S3 – NO (normálně rozevřen).
CZ 300-76 Knoflíková mozaika HU 300-76 Gomb
Válassz ki egy tetszőleges ábrát vagy találj ki egyet, majd rakd ki a táblára a minta alapján!
A játék fejleszti a megfigyelőképességet, a színek felismerését, a kreatív gondolkodást és a finommoto...
Aerosolový slovník
Actinomycetes / Aktinomycety - Skupina bakterií s morfologií podobající se plísním (houbám).