therm duo 50, 50 t
Transkript
1iYRGNREVOX]HD~GUåE NRWO$ THERMONA spol. s r.o. Stará osada 258, 664 84 Zastávka Obsah: 1. 3RXåLWt 2. Všeobecný popis 3. Technické údaje 4. Výrobní kontrola 5. =iNODGQtSRN\Q\SURPRQWiå • 8PtVWQtD ]DYãHQtNRWOH • 3LSRMHQtNRWOHQDWHSORYRGQtV\VWpP • 3LSRMHQtNRWOHQDSO\QD HOVt" • Odtah spalin • 3OQQtRWRSQpKRV\VWpPX • 9ROEDUHJXODþQtFKD RYOiGDFtFKSUYN$ • Uvedení kotle do provozu a odstavení 6. 3HGSLV\SURREVOXKXD ~GUåEX • Obsluha a ~GUåED kotle 7. Plynová armatura 8. =DYãHQtNRWOH 9. *UDI\SLSRMRYDFtKRSHWODNXDQDVWYêNRQX 10. Sestava kotle 11. El. schéma zapojení 12.0RGXODþQtHOHNWURQLND0/& 13.=iUXNDDRGSRYGQRVW]DYDG\ 14.2VYGþHQt 2 328ä,7Ë =iYVQiMHGQRWND7+(50'82MHPRGHUQt]GUoj tepelné energie pro objekty s tepelnou ztrátou do 45 kW v VDPRVWDWQpPSRXåLWtD v NDVNiGRYpP]DSRMHQtSURYHONpREMHNW\3RWHEQêYêNRQNRWHOQ\MHPRåQR ]tVNDWMHMLFKVNOiGiQtPGRNDVNiG\NWHUiMHt]HQDNDVNiGRYêPDGLþHPNRWO$YþHWQHNYLWHUPQtUHJXOace. -HPRåQpWDNWR]tVNDWMHGQRGXFKRXPRQWiåt]GURMWHSODV Y\VRNRX~þLQQRVWt.RQVWUXNFHNRWO$V D]HQtP GRNDVNiG]DMLã"XMHVQLåRYiQtSURYR]QtFKQiNODG$D ]WUiWRSURWLNRQYHQþQtPNRWHOQiP-VRX NRQVWUXRYiQ\MDNRVSRWHELþHV PD[LPiOQt~þLQQRVWtV G$UD]em na minimální emise do ovzduší , to ]QDPHQiåHMHMLFKSURYR]MHKRVSRGiUQêDQH]DWåXMHåLYRWQtSURVWHGt9êNRQNRWOHMHSO\QXOH regulovaný v rozsahu 40 –DSL]S$VREXMHVHGOHSRWHEREMHNWXY závislosti na tepelných ztrátách. Vysoký technickêVWDQGDUW]DMLã"XMtSRXåLWpãSLþNRYpNRPSRQHQW\RGSHGQtFKVYWRYêFKYêUREF$ 8SR]RUQQt.RWHOMHXUþHQN SLSRMRYiQtN RWRSQpVRXVWDY~VWHGQtKRY\WiSQtY\EDYHQp H[SDQ]RPDWHPQHERRWHYHQRXH[SDQ]QtQiGRERXRPLQYêãFHPQDGNRWOHP Jednotlivá pURYHGHQtNRWO$7+(50'82MVRXNRQVWUXNþQHãHQ\QiVOHGRYQ DUO 50 – stardartní s plynulou automatickou regulací s odtahem spalin do komína DUO 50 T – stardartní s plynulou automatickou regulací s nuceným odtahem spalin 2. VŠEOBECNÝ POPIS K27/#$'<THERM DUO 50 Plynový kotel THERM DUO je sestaven z QRVQpKRUiPXQDQPåMVRXSLSHYQQ\YãHFKQ\SUYN\ kotle. V KRUQtþiVWLMVRX]DEXGRYiQ\GYDPGQpYêPQtN\SRYUFKRYFKUiQQpVPVtKOLQtNXVH VLOLNRQHP8YQLWWUXENRYQLFYêPQtNXMVRX]DEXGRYiQ\WXUEXOiWRU\NWHUpMHQXWQRFKUiQLWSHG ]DQHVHQtPQHþLVWRWDPL] otopného systému. Z WRKRWRG$YRGXMHQXWQpRVDGLWRWRSQêV\VWpPILOWUHPQD YVWXSXYUDWQpYRG\GRNRWOH3URXGUåHQtPLQLPiOQtFK]WUiWSHQRVXWHSODMHWHEDXGUåRYDWSRYUFKODPHO YêPQtNXY þLVWRW.H ]QHþLVWQtYêPQtNXGRFKi]tQHMþDVWMLVSiOHQtPSUDFKRYêFKþiVWLFSL provozování kotle v SUDãQpPSURVWHGt6SDOLQRYpYêPQtN\MVRXRVD]HQ\QDYVWXSXDXWRPDWLFNêPL RGY]GXãRYDFtPLYHQWLO\QDYêVWXSXKDYDULMQtPLNRQWDNWQtPLWHUPRVWDW\ Spalovací komora je vyrobena z SRKOLQtNRYDQpKRSOHFKXDY\ORåHQDWHSHOQRXL]RODFt3HGQtþHOQtVWQD MHRGQtPDWHOQi1DGVSDOLQRYêPLYêPQtN\MHXPtVWQXVPURYDþWDKXVSDOLQQDNWHUpPMHLQVWDORYiQD WHUPRHOHNWULFNiSRMLVWNDKOtGiQt]SWQpKRWRNXVSDOLQ8NRWO$DG\Ä7³MHQDXVPURYDþLXPtVWQ spalinový ventilátor a jeho správnou funkci kontroluje manostat vzduchu. 9HVSRGQtþiVWLVSDORYDFtNRPRU\MHXPtVWQRVPQiFWLUDPHQQêYRGRXFKOD]HQêQt]NRQR[RYêKRiN moderní stavebnicové konstrukce firmy Polidoro.-HRVD]HQGYPLHOHNWURGDPL]DSDORYDFtPLDMHGQRX LRQL]DþQtSURNRQWUROXKRHQt 1DKRiNMHSLSRMHQDSHVãURXEHQtSO\QRYiDUPDWXUD:KLWH5RGJHUVNWHUiY VRE]DKUQXMHUHJXOiWRU tlaku plynu a dva solenoidové ventily ovládané automatikou. Na plyQRYpDUPDWXHMHXPtVWQPRGXODþQtHOHNWURPDJQHW0DJQHWLFNpMiGURFtYN\PRGXOiWRUXPi QDVWDYLWHOQê]GYLKDWtPXPRåXMHUHJXODFLWODNXSO\QXGRKRiNXY nastaveném rozsahu. 1DYVWXSXYUDWQpYRG\MH]DEXGRYiQRGRSUDYQtþHUSDGOR*UXQGIRVSRS:LOR]DEH]SHþXMtFtSU$WRNYRG\ NRWOHP'RVWDWHþQêSU$WRNWRSQpYRG\NRWOHPMHKOtGiQSU$WRNRYêPVStQDþHP3HGþHUSDGORMHXPtVWQ SRMLVWQêSHWODNRYêYHQWLOSURRFKUDQXNRWOH 2YOiGDFtSDQHOMHFHORSODVWRYê1DSHGQtVWUDQMVRXUR]PtVWQ\RYOiGDFtSUYN\YL]SHGpis pro REVOXKX8YQLWMH]DEXGRYiQD]DSDORYDFtDXWRPDWLND%HUWHOOL)7DSURt]HQtþLQQRVWLNRWOH mikroprocesorová automatika MLC 04.51. 3O\QRYpNRWOH7+(50'82SUDFXMtEH]]DSDORYDFtKRKRiþNXW]QYþQpKRSODPtQNXDMVRX zapalovány elektrickou jLVNURX7tPMHGRVDåHQR~VSRU\SO\QX '$OHåLWpXSR]RUQQt =S$VRERGEUXLRQL]DþQtKRSURXGXMHY]WDåHQN QXORYpPXYRGLþL1HVPtEêWSURWR]DPQQQXORYê YRGLþV fázovým v ]iVXYFHSURSLSRMHQtNRWOH=DSRMHQt]iVXYN\PXVtRGSRYtGDWý61. Pokud tatR]iVDGDQHEXGHGRGUåHQDEXGHNRWHOQHIXQNþQt Kotel v provedení 50 T je konstruován jako otopná jednotka o výkonu 45 kW s nuceným odtahem spalin. 3URWLEåQpPXSURYHGHQtNRWOH'82MHQDYtFRVD]HQVSDOLQRYêPYHQWLOiWRUHPW\SX(6-98 GR s SU$PUHPYêVWXSQtKRKUGODPP7HQWRYHQWLOiWRUMHXPtVWQQDXSUDYHQpPSHUXãRYDþLWDKX s YêYRGHPGR]DGXNH]GLQDNWHUpMHNRWHO]DYãHQ1DYêYRGYHQWLOiWRUXVHSRPRQWiåLNRWOHQDVRXYi SHFKRGNDPPD WtPMHXPRåQQRSRNUDþRYDWRGWDKHPVSDOLQR SU$PUXPPDåSRYêGXFKSHV venkovní zdivo. 3 ýLQQRVWYHQWLOiWRUXtGtDXWRPDWLND%HUWHOOL)7V NRQWURORXVSUiYQpþLQQRVWLSRPRFtPDQRVWDWX vzduchu. Po sepnutí el. kontaktu manostatu se spustí vlastní zapalovací cyklus s následným zapálením SLYHGHQpKRSO\QXQDKRiNX6SDORYDFtSURFHVMHXGUåRYiQY þLQQRVWLLRQL]DþQtVRQGRXXPtVWQRX v SODPHQLQDKRiNX2EKRYpþHUSDGORMHX WFKWRNRWO$*581')26SRS:,/2 Z NLYN\SRXåLWHOQêFKSLSRMRYDFtFKSHWODN$Y\FKi]tSLPD[YêNRQXNRWOHD teplotním spádu do 20 oC SRPUQQt]NêSHWODNSURRWRSQêV\VWpP-HWHEDSRþtWDWV StGDYQêPV\VWpPRYêPþHUSDGOHP]YOiãW v StSDGHFKLQVWDODFHVDPRVWDWQpKRNRWOHGRWRSQpKRV\VWpPX]HMPpQDV horizontálními rozvody). 3URXPtVWQtRGWDKXVSDOLQSODWtVWHMQiNULWpULDMDNRSURY\~VWQtNODVLFNêFKNRWO$785%2YL]7HFKQLFNi pravidla G 800 01. 3. TECHNICKÉ ÚDAJE PU jednotka Palivo DUO 50 DUO 50T zemní plyn propan zemní plyn propan 0D[LPiOQtWHSHOQêStNRQ kW 49 46,7 49 46,7 0LQLPiOQtWHSHOQêStNRQ kW 19,6 19,6 19,6 19,6 0D[LPiOQtWHSHOQêYêNRQQDY\WiSQt kW 45 43 45 43 0LQLPiOQtWHSHOQêYêNRQQDY\WiSQt kW 18 18 18 18 3RþHWWU\VHNKRiNX ks 36 36 Vrtání trysek : mm 1 0,6 1 0,6 3HWODNSO\QXQDYVWXSXVSRWHELþH mbar 18 37 18 37 Tlak plynu na tr\VNiFKKRiNX mbar 1,9 – 12 6 – 31 1,9 – 12 6 – 31 3 2,1 – 5,2 0,75 – 1,8 2,1 – 5,2 0,75 – 1,8 6SRWHEDSO\QX m /h 0D[SHWODNWRSV\VWpPX bar 3 3 0LQSHWODNWRSV\VWpPX bar 0,7 0,7 Max. výstupní teplota topné vody o C 80 80 3U$PUQiWHSORWDVSDOLn o C 100 100 32,3 – 44,7 32,3 – 44,7 52 53 92 92 +PRWQRVWQtSU$WRNVSDOLQ g.s -1 0D[KOXþQRVWGOHý61 dB ÒþLQQRVWNRWOH % Hodnoty spalování: CO NOx -1 32 – 60 17 – 40 32 – 60 17 – 40 -1 20 – 49 14 – 20 20 – 49 14 – 20 mg.kWh mg.kWh 7tGD12xNRWOHGOHý61(1$ 5 5 V / Hz 230 /50 230 / 50 -PHQRYLWêHOStNRQ W 120 150 -PHQRYLWêSURXGSRMLVWN\VSRWHELþH A 1,6 1,6 IP 41 IP 41 Prostory normální AA5/AB5 Prostory normální AA5/AB5 -PHQRYLWpQDSiMHFtQDSWtIUHNYHQFH 6WXSHNU\WtHOþiVWt ProstHGtGOHý61– 3 3U$PUNRXRYRGXRGWDKX mm 160 / 80 5R]PU\YêãNDãtNDKORXEND mm 900/560/430 900/560/430 kg 57 58 Hmotnost kotle 4. Výrobní kontrola 4 9ãHFKQ\VRXþiVWLNRWOHMVRXSHG]NRPSOHWRYiQtPYêUREFHPSHNRQWURORYiQ\DQDVWDYHQ\.DåGêNRWHO MHSH]NRXãHQQDWVQRVWYRGQtKRRNUXKXWVQRVWSO\QRYpKRRNUXKXDMHQDVWDYHQDDSH]NRXãHQDþLQQRVW UHJXODþQtFKDSRMLVWQêFKSUYN$ =iNODGQtSRN\Q\SURPRQWiåNRWOH 0RQWiåNRWO$VPtSURYiGWNYDOLILNRYDQiRGERUQiILUPDSLþHPåMHQXWQpGEiWQDYãHFKQ\UDG\D XSR]RUQQtY WpWRStUXþFH0RQWiåPXVtEêWSURYHGHQDY souladu s SODWQêPLQRUPDPLDSHGSLV\– viz ý61ý61– 7 –ý61Dý61. 3RYLQQRVWtPRQWiåQtILUP\MHSURYpVWSHGLQVWDODFtNRQWUROXVSUiYQpYROE\W\SXNRWOHY]KOHGHPN IXQNþQtPYODVWQRVWHPDSRåDGRYDQêPSDUDPHWU$PYþHWQGUXKXSDOLYDDNRQWUROXR]QDþHQtQDREDOX zda odpovídá objednanému typu kotle. Po rozbalení je nutné provést kontrolu správnosti a úplnosti dodávky. V StSDGSRFK\EQRVWtLQIRUPXMWHSHGPRQWiåtNRWOHYêUREFHQHERGRGDYDWHOH ♦ 8PtVWQtNRWOH .RWOHDG\THERM DUOO]HXPtV"RYDWGRE\WRYêFKLQHE\WRYêFKSURVWRUNRWHOHQ Kotle mají krytí elektrickýcKþiVWtIP 41NWHUpVSOXMHSRGPtQN\RGROQRVWLSURWLVYLVOHNDSDMtFtYRG Místnost, v QtåMHNRWHOXPtVWQPXVtEêWGOHý61– 3 SURVWHGtRE\þHMQp]iNODGQtFKUiQQp SHGPUD]HPV okolní teplotou vzduchu v rozsahu +5 do +35 oC s relativní vlhkostí do 80%. Spalovací vzduch nesmí obsahovat halogenouhlovodíky a páry agresívních látek, nesmí mít vysokou vlhkost a prašnost. Dále musí dle ý61VSORYDWQiVOHGXMtFtSRåDGDYN\ QDN:LQVWDORYDQpKRYêNRQXPXVtSLSDGDWP3 prostoru. 2XSRGODK\PXVtEêW]t]HQêQHX]DYtUDWHOQêRWYRURWYRU\RFHONRYpYHOLNRVWLQHMPpQP2 YROQpKRSU$H]XQDN:YêNRQXLQVWDORYDQêFKNRWO$QHMPpQYãDNP2. YHYWUDQêFKSURVWRUiFKNGHSLSDGDMtQHMPpQP3 na 1 kW výkonu instalovanýchNRWO$VHQHPXVt QHX]DYtUDWHOQêRWYRU]L]RYDW K REU\VXNRWOHVHQHVPtSLEOLåRYDWSHGPW\YHVP\VOXý61 (klasifikované dle ý61 ) na menší vzdálenost jak: 100 mm z PDWHULiO$QHVQDGQRKRODYêFKWåFHKRODYêFKQHERVWHGQKRODYêch 200 mm z OHKFHKRODYêFKKPRWQDSGHYRYOiNQLWpGHVN\FHOXOy]RYpKPRW\ polyuretan, polystyrén, polyetylén, PVC apod.) 8SR]RUQQt 3HG]DSRþHWtPSUDFtNWHUpPRKRXPtW]DQiVOHGHN]PQXSURVWHGtY prostoru instalovaného kotle QDSSUiFHV QiWURYêPLKPRWDPLOHSLGO\DWGMHQXWQpY\SQRXWNRWHOVt"RYêPY\StQDþHP ♦ =DYãHQtNRWOH 3HGLQVWDODFtNRWOHMHQXWQpVHSHVYGþLWåH]YROHQpPtVWRRGSRYtGiSRåDGDYN$PQDXPtVWQtRGYRGX VSDOLQDåHMVRXVSOQQpPLnimální vzdálenosti uvedené v SHGFKi]HMtFtFKNDSLWROiFK3LPRQWiåLNRWO$ v NDVNiGGRSRUXþXMHPHMHMLFKXSHYQQtQDVSROHþQRXQRVQRXNRQVWUXNFL ♦ 3LSRMHQtNRWOHQDWHSORYRGQtV\VWpP Kotelny s NDVNiGRXNRWO$7+(50'82MHQXWQRHãLWSURMHNWHPV vazbouQDYêSRþW\K\GUDXOLFNêFK SRPU$RWRSQpVRXVWDY\Y]KOHGHPN FHONRYêPSHGiYDQêPYêNRQ$P 9ODVWQtSLSRMHQtNRWO$N RWRSQêPUR]YRG$PDUR]YRGXSO\QXPXVtEêWSURYHGHQRWDNRYêP]S$VREHP DE\QHE\O\VLORYQDPiKiQ\SLSRMRYDFtYêYRG\NRWOH 3HGSLSRMHQtPNRWOHQDRWRSQêV\VWpPGRSRUXþXMHPHWHQWRG$NODGQSURSOiFKQRXWDE\VHRGVWUDQLO\ StSDGQpGUREQpQHþLVWRW\9VWXSYUDWQpYRG\GRNRWOHPXVtEêWRVD]HQYKRGQêPILOWUHP Otopná soustava musí být provedena v souladu s: ý61 – Projektování a PRQWiå~VWHGQtKRY\WiSQt ý61 –=DEH]SHþRYDFt]Dt]HQtSUR~VWHGQtY\WiSQtD RKtYiQtXåLWNRYpYRG\ 3URVSUiYQRXþLQQRVWNRWOHMHWHEDGRGUåHWPLQLPiOQtSHWODNNRWORYpKRRNUXKXEDUX ♦ 3LSRMHQtNRWOHQDSO\Q 5 3LSRMHQtNRWOHQDSO\QPXVtEêWSURYHGHQRYåG\RSUiYQQRXILUPRXSRGOHY\KOiãN\ý8%3Dý%8 VEYH]QQtY\KOiãN\VEDWRV pracovníky s kvalifikací podle vyhlášky FMPE VEYH]QQtY\KOiãN\)03(VEDSRGOHVFKYiOHQpGRNXPHQWace pro plynoinstalaci. 3HGNRWHOVHQHXPtV"XMHMLåUHJXOiWRUSO\QX7HQWRMHREVDåHQYHVGUXåHQpSO\QRYpDUPDWXHNWHUiMH VRXþiVWtNRWOH3HGNRWHOPXVtEêWRVD]HQSO\QRYêNRKRXW.V NOtþHPQDRYOiGiQtQHERNXORYê ventil s atestem pro plyn. UzávUSO\QXPXVtEêWYROQStVWXSQê .RWHOMHXUþHQN provozu na zemní plynRYêKHYQRVWLRGGRN:KP3 a jmenovitém tlaku v rozvodné síti 18 mbar a propan o jmenovitém tlaku v rozvodné síti 37 mbar. 8SR]RUQQt 3LSHVWDYENRWOH] hlediskD]PQ\SO\QXMHQXWQRSURYpVWGHPRQWiåUDPS\KRiNXSURYpVW]iPQX trysek a ]PQLWQDVWDYHQtWODNRYpKRUR]PH]tQDSO\QRYpDUPDWXH'iOHMHWHEDSURYpVW]PQXQDVWDYHQt StVOXãQêFKSDUDPHWU$QDPRGXODþQtHOHNWURQLFH7\WRþLQQRVWLP$åHSURYpVWSRX]HVHUvisní pracovník. ♦ 3LSRMHQtNRWOHQDHOVt" .RWOHMVRXY\EDYHQ\WtåLORYêPSRK\EOLYêPStYRGHPV YLGOLFt3LSRMXMtVHGRVt"RYp]iVXYN\ LQVWDORYDQpSREOtåNRWOHWDNDE\Vt"RYiYLGOLFHE\ODStVWXSQiSRLQVWDODFLNRWOHYHVP\VOXSRåDGDYNX ý61(1335-1=iVXYNDPXVtY\KRYRYDWRFKUDQQXORYiQtPQHER]HPQQtPDMHMtSLSRMHQtPXVt být dle ý61WDNDE\RFKUDQQêNROtNE\OQDKRHDVWHGQtQHERQXORYDFtYRGLþE\OSLSRMHQQD SUDYRXGXWLQNXSLSRKOHGX]SHGX6t"RYpQDSWtPXVtEêW9±10%.,QVWDODFL]iVXYN\SLSRMHQt SURVWRURYpKRWHUPRVWDWXDVHUYLVHOHNWULFNpþiVWLNRWOHP$åHSURYiGWRVREDV odbornou elektrotechnickou NYDOLILNDFtGOHY\KOiãN\þ ♦ 3LSRMHQtNRWOHQDNRPtQ .RWHOVHSLSRMXMHQD]YOiãWQtNRPtQRYêSU$GXFKNWHUêPXVtPtWSU$PURGSRYtGDMtFtYêNRQXNRWOHD PXVtEêWY\YORåNRYiQY QiYD]QRVWLQDý613HGSLSRMHQtPNRWOHGRSRUXþXMHPHNRQ]XOWDFLV místním NRPLQtNHPSRS]DMLãWQtSHGEåQpUHYL]H.RWHOMHY\EDYHQYHVWDYQêPSHUXãRYDþHPWDKX 'RSRUXþHQêNRPtQRYêWDKQDGSHUXãRYDþHPMHY rozmezí 3 –3DýiVWNRXRYRGXQDGSHUXãRYDþHP PXVtEêWVYLVOiGRY]GiOHQRVWLPP'RSRUXþXMHPHYROLWGDOãtVSDOLQRYRXFHVWXFRQHMNUDWãt Komín musí být proveden v souladu s ý61Dý61DVSORYDWQiVOHGXMtFtSRåDGDYN\ .RPtQRYiYORåNDPXVtEêW] QHSURSXVWQpKRPDWHULiOXDRGROQiY$þLVSDOLQiPDNRQGHQ]iWX .RPtQPXVtY\ND]RYDWGRVWDWHþQRXSHYQRVWDPDOêSURVWXSWHSOD0XVtEêWGRVWDWHþQWVQêDE\VH zabránilo ochlazování. 3/ Aby vítr nemohl kolem kRPtQXWYRLWWODNRYp]yQ\NWHUpMVRXVLOQMãtQHåWDKVSDOLQPXVtPtWNRPtQ ~VWtQDGãLNPRXVWHFKRXPLQPQDGKHEHQHPQDGSORFKRXVWHFKRXPLQPQDG~URYQtVWHFK\ SRSSU$EåQpDWLN\GOHý61 odst. 84 – 86. ♦ 3OQQtRWRSQpKRV\VWpPX 3RGREXSOQQtRWRSQpKRV\VWpPXPXVtEêWNRWHORGSRMHQRGHOVtWY\WDåHQtPVt"RYpYLGOLFH]H ]iVXYN\3OQtFtWODNPXVtEêWSLVWXGHQpPV\VWpPXDåEDUX3OQQtPXVtSUREtKDWSRPDOXDE\ PRKO\XQLNDWY]GXFKRYpEXEOLQ\StVOXãQêPLRGY]GXãRYDFtPLYHQWLO\9RGDSURSUYQtQDSOQQtL pro GRSRXãWQtPXVtEêWGOHý61þLUiEH]EDUYiEH]VXVSHQGRYDQêFKOiWHNROHMHD chemicky DJUHVtYQtFKStPVtQHVPtEêWN\VHOiS+QLåãtQHåV PLQLPiOQtXKOLþLWDQRYRXWYUGRVWtPD[ mval/l). V StSDG~SUDY\WYUGRVWLMHQXWQpSRXåtWGRSRUXþHQpStSUDYN\ 3LQHGRGUåHQtYêãHXYHGHQêFKSRåDGDYN$VHQHY]WDKXMH]iUXNDQDSRãNR]HQpNRPSRQHQW\ ♦ 9ROEDUHJXODþQtFKDRYOiGDFtFKSUYN$ .RWHOMHY\EDYHQ]iNODGQtPLUHJXODþQtPLD]DEH]SHþRYDFtPLSUYN\MDNMH]HMmé z následujících HOHNWURVFKHPDW-DNRGDOãtUR]ãtHQtPRåQRVWLUHJXODFHMHPRåQRSRXåtWUHJXODFLSRGOHSURVWRURYpWHSORW\ YH]YROHQpUHIHUHQþQtPtVWQRVWLQHERHNYLWHUPQtUHJXODFLY\WiSFtYRG\SRSNRPELQRYDQRXUHJXODFL Kotelny s NDVNiGRXWFKWRNRWO$O]HYêKRGQUHJXORYDWDGLþHPNRWO$+RQH\ZHOO$4 -HWRPLNURSURFHVRURYêHNYLWHUPQtUHJXOiWRUVHþW\VWXSRYêPDGLþHPNRWORYêFKVHVWDY 6 S SRPRFtPRWRULFNpKRWURMFHVWQpKRYHQWLOXMHPRåQptGLWRKHY]iVREQtNXWHSOpXåLWNRYpYRG\0H]L nesporné výhody DGLþH$4SDWtPQRKRLQWHOLJHQWQtFKIXQNFtQDSSURVWtGiQtYHGRXFtKRNRWOH UHJXODFHPNNpKRVWDUWXUHJXODFH]YêãHQpKRRKHYXt]HQtSUDFRYQtFKF\NO$NRWO$DWG 3LREMHGQiYFHNRWO$7KHUP'82GRGiYiPHLW\WRUHJXOiWRU\]D]YêKRGQQpFHQ\ 'RSRUXþHQt3URYR]VDPRVWDWQpKRNRWOHEH]YROE\HNYLWHUPQtUHJXODFHGRSRUXþXMHPHtGLWDOHVSR MHGQRGXFKêPSURVWRURYêPWHUPRVWDWHP3URVWRURYiWHSORWDMHþDVRYVWiOiDXGUåXMHNRWHOY delších SURYR]QtFKUHåLPHFK1DVWDYHQtNRWORYpKRWHUPRVWDWXGRSRUXþujeme v SHFKRGQpPREGREtSRG]LPMDUR na 60 °C, v ]LPQtPREGREtGR&-HYKRGQpY\XåtW]DEXGRYDQpPRåQRVWLHNYLWHUPQtUHJXODFHEX VDPRVWDWQpQHERGRSOQQRXSURVWRURYêPWHUPRVWDWHPMDNMHXYHGHQRQtåH 7\WRQiVWDYERYpUHJXODFHQHMVRXSHGPWHPGodávky kotle. ♦ Uvedení do provozu 3HGSUYQtP]DSiOHQtPNRWOHMHQXWQRSURYpVWQiVOHGXMtFtRSDWHQt ♦ ]NRQWURORYDW]GDMHRWRSQêV\VWpPQDSOQQYRGRXDNRWHOVSUiYQRGY]GXãQQ ♦ SHVYGþLWVH]GDMVRXYãHFKQ\YHQWLO\RWHYHQ\ ♦ RWHYtWSO\QRYêNRKRXWDSH]NRXãHWWVQRVWSO\QRYpKRUR]YRGXY kotli. 3RVWXSSLSUYQtP]DSiOHQtNRWOHMHQiVOHGXMtFt ♦ WRþtWNRYêVWXSQtWHSORW\NRWOHQDVWDYLWQDPD[LPXP ♦ Vt"RYêStYRG]DVWUþLWGR]iVXYN\D]DSQRXWNRWHOSHStQDþHPSURYR]QtFKUHåLP$ ♦ NUiWNRGREêPRWRþHQtPSHStQDþHSURYR]QtFKUHåLP$GRSUDYpNUDMQtSRORK\VHNRWHODXWRPDWLFN\ ]DSiOtSLRGY]GXãQQpPSO\QRYpPStYRGX ♦ SURYpVWNRQWUROXVSUiYQpþLQQRVWLYãHFKWHUPRVWDW$DRYOiGDFtFKSUYN$ ♦ SURYpVWNRQWUROXQDVWDYHQtYêNRQRYpKRUR]VDKXNRWOHSRSXSUDYLWQDVWDYHQtGOHSRWHEY\WiSQpKR objektu 8SR]RUQQt1DVWDYHQtYêNRQRYpKRUR]VDKXNRWOHDRVWDWQtFKSDUDPHWU$PXVtEêWY souladu s WHFKQLFNêPL~GDML-DNpNROLSHWåRYiQtDQHVSUiYQpXåtYiQtNRWOHP$åH]S$VRELW]QHKRGQRFHQtMHKR NRPSRQHQW$1DWDNWRSRãNR]HQpNRPSRQHQW\QHO]HXSODWRYDW]iUXNX ♦ Odstavení kotle .RWHOO]HY\SQRXQDNUDWãtGREXSHStQDþHPSURYR]QtFKUHåLP$SRStSDGY\StQDþHPQDSURVWRURYpP termostatu. 3URGORXKRGREpRGVWDYHQtNRWOHPLPRWRSQRXVH]yQXQDSY SU$EKXOHWQtGRYROHQpMHYKRGQpX]DYtt plynový kohout. 3HSLV\SURREVOXKXD~GUåEX ♦ Obsluha kotle 2EVOXKRYDWNRWHOVPtSRX]HRVREDVWDUãtURN$ SIGNÁLKA PORUCHA 7(3/205 SIGNÁLKA ZAPNUTO 7/$.205 SIGNÁLKA PROVOZ 3(3Ë1$ý PROVOZNÍCH 5(ä,0# NASTAVENÍ TEPLOTY TOPENÍ 7HSORPUMHPtFtStVWURMSURPHQtYêVWXSQtWHSORW\YRG\7ODNRPUPtWODNYRG\Y topném systému. 7 7RþtWNHPVLXåLYDWHOQDVWDYXMHWHSORWXYRG\Y otopném systému v rozsahu 35 – 80o&'RSRUXþHQê rozsah je 55 – 80o C, v StSDG]YROHQpHNYLWHUPQtUHJXODFHVNORQWRSQpNLYN\ 6LJQiONDÄ3258&+$³VLJQDOL]XMHVWDYNG\VHHOHNWURQLFHQHSRGDLORNRWHO]DSiOLW QDS]G$YRGXSHUXãHQpGRGiYN\SO\QX1iYUDWGRSURYR]QtKRVWDYXVHXVNXWHþQtNUiWNRGREêP RWRþHQtPSHStQDþHSURYR]QtFKUHåLP$GRSUDYpNUDMQtSRORK\SLNRQWUROHþLQQRVWLNRWOH 6LJQiONDÄ35292=³VLJQDOL]XMHKRHQtNRWOH 6LJQiONDÄ=$31872³VORXåtN VLJQDOL]DFL]DSQXWtUHåLPXNRWOH 3HStQDþSURYR]QtFKUHåLP$NRWOHPiQiVOHGXMtFtSRORK\ 1. 9\SQXWtNRWOHUHåLP$-SUREKþHUSDGODSRKRG]$VWiYiYþLQQRVWL 2. /HWQtSURYR]]DSQXWDStSUDYD789WRSHQtY\SQXWRY\XåLWRXNRWO$7+(50'82V SLSRMHQêP zásobníkem TUV 3. =LPQtSURYR]]DSQXWRWRSHQtLStSRKHY]iVREQtNX789 4. Odblokování poruchového stavu kotle 8SR]RUQQt.RWOH7KHUPMVRXY\EDYHQ\SRMLVWNRX]SWQpKRWRNXVSDOLQNWHUiSLSRUXãHY\YROi X]DYHQtStYRGXSDOLYDV následnou signalizací poruchy kotle. Znovuuvedení do provozu se provede Y\SQXWtPNRWOHSHStQDþHPUHåLP$DMHKRRSWQêP]DSQXWtP3LRSDNRYDQpPSHUXãHQtSURYR]XMHQXWQR YRODWVHUYLVQtKRWHFKQLNDSURNRQWUROXSU$FKRGQRVWLFHVW\RGYRGXVSDOLQ-DNêNROLQHRGERUQê]iVDKGR pojistk\]SWQpKRWRNXVSDOLQDMHMtFKREYRG$MH]DNi]iQ 3LSLEOtåHQtVHQHERSLGRW\NXNRQWUROQtKRSU$]RUXKUR]tQHEH]SHþtSRSiOHQt 3UDFRYQtNPRQWiåQ–VHUYLVQtRUJDQL]DFHMHSRYLQHQSLVSXãWQtSURYpVWVH]QiPHQtXåLYDWHOH s kotlem, jeho jednotliYêPLþiVWPLD]S$VREHPRYOiGiQt 8åLYDWHOMHSRYLQHQGEiWQDVSUiYQpSRXåtYiQtNRWOHY souladu s WtPWRQiYRGHPFRåMHSRGPtQNDSUR SL]QiQt]iUXN\ ♦ ÒGUåED 3UDYLGHOQi~GUåEDMHYHOPLG$OHåLWiSURVSROHKOLYêFKRGNRWOHDGRVDåHQtY\VRNpåLYRWQRVWLkotle a ~þLQQRVWLVSDORYiQt'RSRUXþXMHPHXåLYDWHOLDE\VHVSRMLOVHVHUYLVQtRUJDQL]DFtY PtVWE\GOLãWD]DMLVWLO VLSUDYLGHOQpSURKOtGN\NRWOHSRURFHþLQQRVWLYL]3RGPtQN\SURXSODWQQt]iUXN\6HUYLVQtWHFKQLN provede kontrolu ovládacích a zabezSHþRYDFtFKSUYN$NRWOHNRQWUROXWVQRVWLSO\QRYpKRDYRGQtKR UR]YRGXSRSY\þLVWQtKRiNXDYêPQtNXRGVSiOHQêFKSUDFKRYêFKþiVWLF 9QMãtSOiã"P$åHXåLYDWHOþLVWLWKDGUHPQDPRþHQêPY PêGORYpYRGDSRWRPRVXãLWVXFKêPKDGUHP 7. Plynová armatura WHITE – RODGES 9100 =DYãHQtNRWOH 8 MontáåQtOLãWDSUR]DYãHQtNRWOH 560 430 *UDISRXåLWHOQêFKSLSRMRYDFtFKSHWODN$WRSQpYRG\ 3LSRMRYDFtSHWODN7KHUP'82 9êVWXSQtSHWODNPEDU :LOR *UXQIRV 3U$WRNYRG\P K 8SR]RUQQt.LYN\SRXåLWHOQêFKSLSRMRYDFtFKSHWODN$WRSQpYRG\MVRX]SUDFRYiQ\QDþHUSDGOD:LOR 25/70 a Grundfos 15/60 naQHMY\ããtUHJXODþQtVWXSH9]KOHGHPN YêNRQXNRWOHQHGRSRUXþXMHPHYêNRQ þHUSDGODVQLåRYDW 9 9.2 Grafy nastavení výkonu kotle *UDIQDVWDYHQtYêNRQX7+(50'82]HPQtSO\QWU\VN\PP 7ODNSO\QXPEDU 9êNRQNRWOHN: *UDIQDVWDYHQtYêNRQX7+(50'82SURSDQWU\VN\PP 7ODNSO\QXPEDU 9êNRQNRWOHN: 10 10.1 Sestava kotle –þHOQtSRKOHG7+(50'82 11 10.2 Sestava kotle –þHOQtSRKOHG7+(50'827 12 10.3 Sestava kotle –ERþQtSRKOHG 13 11.1 El. schéma zapojení THERM DUO 50 14 11.2 El. schéma zapojení THERM DUO 50 T 15 0RGXODþQtHOHNWURQLND0/& 3RSLVQDVWDYRYDFtFKDLQGLNDþQtFKSUYN$ Trimry 6HUYLVQtVStQDþH P1 -QDVWDYHQtGREKXþHUSDGOD JP1 - nastavení start.výkonu (spojením zapnuto) P2 -QDVWDYHQtDQWLF\NODþQtKRþDVX JP2 - nastavení ekvitermní regulace topení (spojením zapnuto) P6 - nastavení max. výkonu topení JP3 -QDVWDYHQtRKHYX]iVREQtNX789VSRMHQtP]DSQXWR P7 - nastavení start. výkonu JP5 - nastavení volby plynu zemní / propan (spojením propan) Kontrolní LED LD4 -HOHNWURQLNDSRGQDSWtP LD6 - sepnutí relé 3-cestného ventilu LD5 - sepnutí relé zapalovací automatiky LD7 -VHSQXWtUHOpþHUSDGOD Nastavení výrobcem: JP1-3-3UR]SRMHQ\UHåLPGREKþHUSDGOD3 PLQXWDQWLF\NODþQt þDV3 PLQXWYROEDSO\QX-3GOHREMHGQiYN\ 3RSLVþLQQRVWL 1.1 5HåLPRKHYXWRSQpKRV\VWpPXEH]HNYLWHUPQtUHJXODFH 1DVWDYHQtýLGORYHQNRYQtWHSORW\QHQtSLSRMHQRVHUYLVQtVStQDþH-3-3-3UR]SRMHQ\ 3UDFRYQtIi]HNRWOH]DþtQiVHSQXWtPSURVWRURYpKRWHUPRVWDWXSHStQDþUHåLP$YSROR]H]LPQtSURYR] $NWLYXMHVHFKRGREKRYpKRþHUSDGODD zapalovací automatika. Zapálení kotle probíhá na nastavený startovací výkRQ7HQMHXGUåRYiQSRGREXVHNXQGSR]DSiOHQtNRWOH]SWQiYD]ED]H]DSDORYDFt DXWRPDWLN\3RWpMHYêNRQVQtåHQQDPLQLPXPV SRPDOêPOLQHiUQtPQiEKHPFFDPLQN bodu modulace, daným nastavením max. výkonu topení (trimrem P6). Regulace výkonu kotle v této fázi je W\SX3,'SURSRUFLRQiOQLQWHJUDþQGHULYDþQtV XGUåRYiQtPWHSORW\QDVWDYHQpWRþtWNHPQDRYOiGDFtP panelu (v rozsahu 35 – 80 o&3LRKHYXWRSQpKRV\VWpPXV QLåãtPStNRQHPQHåMHPLQLPiOQtYêNRQ kotle, dojde ke zvýšení výstupní teploty topné vody o 5o C nad nastavenou hodnotu. V této fázi kotel SHUXãtKRHQtSL]DFKRYiQtFKRGXREKRYpþHUSDGODD VSXVWtþDVRYpRPH]HQtRSWQpKR]DSiOHQtWULPUHP P2 – rozsah nastavení 0 – 10 minut). Tím se kotel stává vysoce adaptabilním zdrojem tepla vzhledem k YHONpPXPQRåVWYtQiVOHGQUHJXORYDQêFKRWRSQêFKVRXVWDYQDS]yQRYpUHJXODFHWHUPRVWDWLFNp ventily atd.). 3LUR]HSQXWtSURVWRURYpKRWHUPRVWDWXMHVSXãWQDIXQNFHQDVWDYLWHOQpKRþDVRYRPH]HQpKRGREKX þHUSDGODWULPUHP3– rozsah nastavení 0 –PLQXW7pWRIXQNFHVHY\XåtYiSURGRFKOD]HQtYêPQtNX DRGþHUSiQtWHSOD]HVSDORYDFtNRPRU\DNH]OHSãHQtUR]ORåHQtWHSORWRWRSQêFKWOHV]YOiãWX KRUL]RQWiOQtFKUR]YRG$SLSRXåLWtSURVWRURYêFKUHJXOiWRU$V PI vazbou s krátkými pracovními cykly QDS+RQH\ZHOO&0 1.2 5HåLPRKHYXRWRSQpKRV\VWpPXV ekvitermní regulací 1DVWDYHQtýLGORYHQNRYQtWHSORW\SLSRMHQRVHUYLVQtVStQDþ-3VSRMHQ-3-3UR]SRMHQ\ Pracovní fáze kotle jsou shodné s YêãHXYHGHQêPUHåLPHPRGVWV tím rozdílem,åHWHSORWDRWRSQp VRXVWDY\MHQDVWDYHQDDXWRPDWLFN\GOHYHQNRYQtWHSORW\]MLãWQpþLGOHP9êSRþHWSRåDGRYDQpWHSORW\ otopné soustavy je funkce venkovní teploty a funkce faktoru „K“NWHUêVHQDVWDYXMHWRþtWNHPWHSORW\ topné vody na ovládacím panelu, dle následujícího vzorce: Ttop = (20 – Text) * K + 20 oC Ttop = teplota topné vody Text = venkovní teplota 16 Ttop (oC) Text (oC) Z YêãHXYHGHQpKRY\SOêYiåHWRþtWNHPSURQDVWDYHQtWHSORW\WRSHQtQDRYOiGDFtPSDQHOXVHY tomto UHåLPXNRWOHQDVWDYXMHSRåDGRYDQiWHSORWDY\WiSFtKRSURVWRUX3RþiWHþQtQDVWDYHQtMH„K“ = 1,8 FRåMH XSURVWHGQDVWDYRYDFtGUiK\XND]RYDWHOQDKRUXMDNMHQDNUHVOHQRQDREUi]NX3RNRQWUROHWHSORW\ Y\WiSQpKRSURVWRUXFFD]DKRGLQO]HSURYpVWQDVWDYHQtGOHYDãLFKSRåDGDYN$QDWHSHOQRXSRKRGX 7DNWRQDVWDYHQiKODGLQDWHSORW\Y\WiSQpKRSURVWRUXEXGHXGUåRYiQDDXWRPDWLFN\EH]]iYLVORVWLQD ]PQiFKYHQNRYQtWHSORW\ 9\XåLWtPWRKRWRUHåLPXUHJXODFHNRWOHGRFtOtPHGDOãtFKVQtåHQtSURYR]QtFKQiNODG$SL]OHSãHQtWHSHOné SRKRG\NRQWLQXiOQtRKHYRWRSQêFKWOHV9 QHSRVOHGQtDGRFHQtPHWXWRPRåQRVWMDNRSHGUHJXODFL SULPiUQtKRWRSQpKRRNUXKXSLSRXåLWt]yQRYpUHJXODFHVPãRYDFtPLYHQWLO\DWG 6DPR]HMPO]HSURVQtåHQtWHSORW\Y\WiSFtKRSURVWRUXSLSRMLWSURVWRrový termostat. V WRPWRStSDG GRSRUXþXMHPH provedení bez PI regulace (pouze se spínáním dle teplotní diference). Faktor „K“ se nastaví na PtUQ]YêãHQRXKRGQRWXRSURWLSURYR]XEH]SURVWRURYpKRWHUPRVWDWX V StSDGSRUXFK\þLGODYHQNRYQtWHSORW\MHWHQWRVWDYVLJQDOL]RYiQDNRWHOSRNUDþXMHY provozu s teplotou topné soustavy dle nastavení v SHGFKR]tPUHåLPXRGVW 5HåLPRKHYX]iVREQtNX789 1DVWDYHQt6HUYLVQtVStQDþ-3GOHYêãHXYHGHQpKR-3UR]SRMHQ-3VSRMHQ Obvody elektronické rHJXODFHMVRXX]S$VREHQ\SURStSDGQêSRåDGDYHNRKHYX789Y zásobníku. Otopný systém se na výstupu topné vody z kotle osadí trojcestným ventilem s propojením na topnou YORåNX]iVREQtNX9RGLþHRYOiGiQtWURMFHVWQpKRYHQWLOXDWHUPRVWDWX]iVREQtNX789VHSLpojí na StVOXãQpNRQHNWRU\GOHVFKpPDHO]DSRMHQtNRWOH 3UDFRYQtIi]HWRKRWRUHåLPXNRWOH]DþtQiVHSQXWtPWHUPRVWDWX]iVREQtNX$NWLYXMHVHUHOpWURMFHVWQpKR YHQWLOXDYHQWLOMHSHVWDYtGRSRORK\RKHYX]iVREQtNX7893RVHNXQGiFKVHSQHUHOpþHUSadla a ]DSDORYDFtDXWRPDWLN\.RWHO]DSiOtQDVWDUWRYDFtYêNRQVHNXQG\SR]DSiOHQtNRWOHDQiVOHGQ]Yêãt YêNRQNRWOHQDPD[LPXPDE\FRPRåQiQHMGtYH]YêãLOYêVWXSQtWHSORWXQDo&7XWRWHSORWXXGUåXMH UHJXODFtYêNRQXW\SX3,'3LRKiWt]iVREQtNXUR]HSQHWHUPRVWDWNRWHOSHUXãtKRHQt3RVHNXQGiFK VH]DVWDYtþHUSDGORDY\SQHUHOpWURMFHVWQpKRYHQWLOXþtPåVHSHVWDYtGRSRORK\WRSHQt3RGREX SHVWDYHQtYHQWLOXFFDVHNXQGMHEORNRYiQMDNêNROLSRåDGDYHNQD]DSiOHQt1iVOHGQP$åHNRWHO poNUDþRYDWY RKHYXWRSQpKRV\VWpPXGOHSRåDGDYNX 2KHY]iVREQtNX789PiY StSDGVRXEåQêFKSRåDGDYN$SHGQRVWSHGWRSHQtP 17 3tGDYQpIXQNFH ∗ 3UDYLGHOQpVSXãWQtþHUSDGODY GREPLPRSURYR]QDPLQXW\SRKRGLQiFKQHþLQQRVWL ∗ Protizámrazová oFKUDQDVHDNWLYXMHSLSRNOHVXWHSORW\Y kotli pod 8 o&6SXVWtVHþHUSDGORNRWHOVH zapálí a RKtYiWRSQêRNUXKGRo&3LGRVDåHQtWpWRWHSORW\RSWY\SQH ∗ 2SWRYQiNRQWURODSU$WRNRYpKRVStQDþHMHDNWLYRYiQDY StSDGåHGRVHNXQGFKRGXþHUSDGOD QHVHSQHSU$WRNRYêVStQDþýHUSDGORVH]DVWDYtDSRVHNXQGiFKMHSURYHGHQGDOãtSRNXVVSXãWQt NRWOH7HQWRMHYVHRSDNXMH[3RWpVHPXVtNRWHOY\SQRXWD]QRYX]DSQRXWSHStQDþHPUHåLP$ 3RNXGGREDQHþLQQRVWLþHUSDGODSHGRSWQêPVSXãWQtNRWOHSHVihla 30 minut, je první interval FKRGXþHUSDGODSURGORXåHQQDVHNXQG,QWHUYDO\PH]LSRNXVQêPLF\NO\MVRXLQGLNRYiQ\GOH následující tabulky indikace poruch. ,QGLNDFHSRUXFKSRSSHNURþHQtSURYR]QtFKKRGQRW ,QGLNDFHMHSURYHGHQDSHUXãRYDQêPVYLWHPStVOXãQpGLRG\YHGYRXLQWHUYDOHFK Pomalý interval rychlý interval LD - „Porucha“ Qt]NêSU$WRNNRWORYpYRG\ Qt]NêSU$WRNLSRVWDUWSRNXVHFK LD – „Provoz“ SHKiWtNRWOHQDGoC SRãNR]HQtQNWHUpWHSORWQtVRQG\ 2EVRXþDVQ reakce havarijního, nebo spalinového termostatu 13. Záruka a RGSRYGQRVW]DYDG\ 9êUREFHQHUXþt]DPHFKDQLFNpSRãNR]HQtMHGQRWOLYêFKNRPSRQHQW$QHãHWUQêP]DFKi]HQtP]DãNRG\ ]S$VREHQpQHRGERUQêP]iVDKHPGRHOHNWURQLN\SLVHL]RYiQtDSLSRMRYiQtQDGVWDYERYêFh regulací, za ãNRG\]S$VREHQpSRXåLWtPMLQêFKVRXþiVWtDNRPSRQHQW$QiKUDGRX]DRULJLQiOQtSRXåtYDQpYêUREFHP 8SODWQQtSUiYD] RGSRYGQRVWL]DYDG\VHtGtGOH2EFKRGQtKR]iNRQtNXXVWDQRYHQtP- 441 a pro náhradu škody ustanovením § 373 - 386 THERMONA spol. s r. RSRVN\WXMH]iUXNXSRGREXPVtF$RGGDWDXYHGHQtGRSURYR]XQHMGpOHYãDN PVtF$RGGDWDH[SHGLFH] výroby. 3RGPtQN\SURXSODWQQt]iUXN\ 1. V souladu se zákonem „O podmínkách podnikání a výkonu státní správy v certifikovaných odvWYtFK a o 6WiWQtHQHUJHWLFNpLQVSHNFLþ6ED ý61ý61³SURYiGW SUDYLGHOQ[URþQNRQWUROXSO\QRYpKRNRWOH.RQWURO\VPtSURYiGWRSUiYQQiRUJDQL]DFHWM smluvní servis. 2. Dokladovat veškeré záznamy o provedených ziUXþQtFKRSUDYiFKD SURYHGHQêFKURþQtFKNRQWURONRWO$ QDStOR]HWRKRWRQiYRGX 18 Záznam o SURYHGHQt]iUXþQtFKL SR]iUXþQtFKRSUDYiFKD URþQtFKNRQWURO Podpis zákazníka Datum záznamu Provedený úkon Smluvní organizace 8SR]RUQQtQDOLNYLGDFLREDOXDYêURENXSRVNRQþHQtMHKRåLYRWQRVWL 9HãNHUpSRXåLWpPDWHULiO\SOQKDUPRQL]XMtV SRåDGDYN\VWDQRYHQêPLYD]iNRQDþ6E DXVWDQRYHQtPDY\KOiãN\þ6E ObDOYêURENXVHEåQRGHY]GiYiGRVEUQ\SDStURYpKRRGSDGX ýiVWLNRWOH] RFHOLPGLDVOLWLQPGLVHRGHY]GiYDMtGRWtGQpKRNRYRYpKRRGSDGX 7HSHOQiL]RODFHVSDORYDFtNRPRU\MH]GUDYRWQQH]iYDGQiDOLNYLGXMHVHGREåQpKRGRPRYQtKRRGSDGX 19 THERMONA spol. s r. o. Stará osada 258 664 84 Zastávka u Brna 269'ý(1Ë2 JAKOSTI A KOMPLETNOSTI VÝROBKU Plynové kotle THERM: 7\SRYpR]QDþHQt 9êUREQtþtVOR Výrobek dodaný s WtPWRRVYGþHQtPRGSRYtGiSODWQêPWHFKQLFNêPQRUPiPD technickým podmínkám. Výrobek byl zhotoven dle své výkresové dokumentace v SRåDGRYDQpNYDOLWD je schválen Strojírenským zkušebním ústavem s.p. autorizovaná osoba 202 &HUWLILNiWW\SXþ Technická kontrola datum: ..................................................................................... razítko a podpis: ....................................................................... 20
Podobné dokumenty
therm 20, 28 tlx(z)
Montáž kotlů smí provádět kvalifikovaná odborná firma, přičemž je nutné dbát na všechny rady a
upozornění v této příručce. Montáž musí být provedena v souladu s platnými normami a předpisy - viz
ČS...
Therm 28 KD
s QiWURYêPLKPRWDPLOHSLGO\DWGMHQXWQpY\SQRXWNRWHOSHStQDþHPUHåLP$SRORKDXND]DWHOHPQDKRUX
♦ =$9â(1Ë.27/(
3HGLQVWDODFtNRWOHMHQXWQpVHSHVYGþLWåH]YROHQpPtVWRRGSRYtGiS...
therm 9, 18, 25, 35, 45 e/b
provedena v souladu s:
ý61 - Projektování a PRQWiå~VWHGQtKRY\WiSní
ý61 - =DEH]SHþRYDFt ]Dt]HQt SUR ~VWHGQt Y\WiSQt D RKtYiQt
XåLWNRYpYRG\
Konference Geotechnika 2008
Geologie oblasti se skládá z jemnozrnných sedimentů při povrchu a 90m mocné vrstvy
pískovců, ve které bude probíhat ražba tunelu. V jižní části se vyskytují v prostoru tunelu
středně ulehlé prachov...
MS 24 FF MS 24 MI - MS 24
7HQWR NRWHO VORXåt N RKĜHYX YRG\ QD WHSORWX QLåãt QHå MH WHSORWD YDUX YRG\ SĜL DWPRVIHULFNpP WODNX9 ]iYLVORVWL QD
SURYHGHQtDYêNRQXPXVtEêWNRWHOSĜLSRMHQQDV\VWpPY\WiSČQtD...
Osobní pocítace
SUR GRVDåHQt SOQpKR YêNRQX MH WHED DE\ %,26
SRGSRURYDO PyG\ 3,2 QHER '0$ 0XOWLZRUG
FRå QRYp SRþtWDþH YWãLQRX VSOXMt
X VWDUãtFK YHU]tFK %,26X O]H GLVN\ )DVW $7$ V
NDSDFLWRX QDG 0% Y\XåtW S...
KN 25C, 28B - návod k instalaci, obsluze a údržbě
x 'RGUåXMWHSRN\Q\NHVNODGRYiQtDS HSUDY YêURENXXYHGHQpQDREDOX
x 3RUR]EDOHQtNRWOH]NRQWUROXMWH~SOQRVWDNRPSOHWQRVWGRGiYN\
x =NRQWUROXMWH]GDW\SNRWOHDS HGHSVDQêSO\QRGSRYtGi...
dakon fb kompletní rozměry a návod
SURYR]XYêUREFHQHRGSRYtGi]DW\WRYDG\DQHY]WDKXMHVHQDQ ]iUXND
.RWHOVHQHVPtWHSHOQ S HW åRYDW
2WRSQiVRXVWDYDPXVtREVDKRYDWQDQHMY\ããtPPtVW DXWRPDWLFNêRGY]GXã RYDFtYHQWLO
3RN...
KN 30B - návod k instalaci
' NODGQêP SURVWXGRYiQtP QiYRGX NREVOX]H ]tVNiWH LQIRUPDFH R NRQVWUXNFL REVOX]H D
EH]SHþQpPSURYR]XNRWOH
3RUR]EDOHQtNRWOH]NRQWUROXMWH~SOQRVWDNRPSOHWQRVWGRGiYN\
=NRQWUROXMWH...